S2600WT Config Guide
S2600WT Config Guide
Revision 2.16
April 23, 2019
<Blank Page>
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
ii
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Date Published Revision Revision Change Description
Document changes
Added Intel Storage System R1000WT Family to the document
Added 2u Short Rail Kit option to document
Updated order information for McAfee Antivirus Software
February 2016 2.07
Fixed several section reference links throughout the document
Added references showing support for Intel® Xeon® processor E5-2600 v4 on all server boards and systems
Added Intel TPM AXXTPME6 and AXXTPME7
Added new board SKU S2600WTTS1R
Document changes
March 2016 2.07
Added new Intel® PCI Express 8-Lane, 4-Port Fan-Out Switch “AXX4PX8HDAIC”
Document changes
June 2016 2.08 Added new Intel® Omni-Path Host Fabric Interface Adapter 100 Series 1 “100HFA016LS”
Added new Intel® Integrated RAID Module “RMS3AC160”
Document changes
Removed from document the SKUs R1208WTTA04NVMR and R1208WTTB04NVMR
Added new 1U riser 3 PCIe* retimer “A1U2PXR3HDAIC”
Added the Ethernet modules AXX1P40FRTIOM and AXX2P40FRTIOM.
July 2016 2.09 Added Remote Management Module 4 version 2 (RoHS free) – AXXRMM4LITE2
Removed Intel® Integrated RAID Module “RMS3AC160”
Added Intel® Integrated RAID Module RMS3VC160
Fixed travel length of Rail spares “AXXFULLRAIL” and “AXXSHRTRAIL”
Rewording note in SKUs “R2312WTTYSR” and “R2224WTTYSR”
Document Changes
October 2.10
Removed line in chapter 5.3 of the “Intel® Accessory Kit A2U44X25NVMEDK2”.
Document Changes
November 2.11 Added data of bracket adjustment for RAILs
Document Changes
Processors Family supported
April 2.12 Replaced the FR1304S3HSBP Spare with FR1304S3HSBP2 (RoHs free).
Added Visual Compute Accelerator, VCA1283LVV
Replaced image of spare “A2UL16RISER2” with correct one.
Document Changes
Added air duct “AWTCOPRODUCT” as a required accessory for the visual computing accelerator
July 2.13
Added back Intel® Integrated RAID Module “RMS3AC160” (Issue fixed)
Added RAID Maintenance Free Backup Unit AXXRFMBU6
Document Changes
April 2.14
Added Visual Compute Accelerator, VCA1585LMV
iii
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Date Published Revision Revision Change Description
Document Changes
September 2018 2.15 Replaced spare “FXXFPANEL” with “FXXFPANEL2”
Updated links of “Additional information for Intel RAID products”
Document Changes
April 2019 2.16
Added details of supported lengths in systems 1U when RAID modules are installed
iv
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Disclaimer
Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Learn more
at Intel.com, or from the OEM or retailer.
You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described
herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed
herein.
No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document.
The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications.
Current characterized errata are available on request.
Intel disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose,
and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade.
Intel, the Intel logo, Xeon, and Xeon Phi, McAfee are trademarks of Intel Corporation in the U.S. and/or other countries.
v
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Table of Contents
1 Intel Server Family Overview ............................................................................................................................................................................................................. 1
1.1 Intel® S2600WT Server Chassis and Server System Product Code Naming Convention .................................................................................................................... 3
1.2 Product Family Summary Chart .................................................................................................................................................................................................................................... 6
1.3 Intel® S2600GZ/GL Product Family to Intel® Server S2600WT Product Family Transition Guide ................................................................................................... 1
1.4 Intel® supported Xeon® Processors E5-2600 v3, v4, Family ............................................................................................................................................................................. 2
vi
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.1 1U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit A1U44X25NVMEDK ...................................................................................49
5.1.1 1U 8x2.5” – Intel® Accessory Kit A1U44X25NVMEDK Cable Guide ............................................................................................................................................. 50
5.2 2U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit A2U44X25NVMEDK ....................................................................................52
5.2.1 2U 8x2.5” – Intel® Accessory Kit A2U44X25NVMEDK SAS/SATA Cable Guide ....................................................................................................................... 54
5.2.2 2U 16x2.5” / 24x2.5” –– Intel® Accessory Kit A2U44X25NVMEDK SAS / SATA Cable Guide ............................................................................................ 55
5.3 2U 8x2.5” Combo PCIe x8 SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit A2U44X25NVMEDK2 .............................................................................56
5.3.1 2U Chassis Drive Bay Identification ........................................................................................................................................................................................................... 58
5.4 2U Rear Mount Hot Swap Drive Bay Accessory Kit – iPC A2UREARHSDK ................................................................................................................................................59
iPC - A2UCBLSSD ................................................................................................................................................................................................................................................................. 60
5.5 2U 8x3.5” Front Mount Hot Swap Backplane Assembly - iPC A2U8X35S3HSDK .................................................................................................................................61
iPC – A2U8X35S3HSDK ..................................................................................................................................................................................................................................................... 61
5.6 2U 8x2.5” Drive Bay Module Options ........................................................................................................................................................................................................................62
iPC – A2U8X25S3HSDK .................................................................................................................................................................................................................................................... 63
iPC – A2U8X25S3DPDK ..................................................................................................................................................................................................................................................... 63
iPC – A2UHANDLKIT ............................................................................................................................................................................................................................................................ 64
5.7 Locking Front Bezel Accessory Kits ............................................................................................................................................................................................................................65
5.7.1 2U Front Bezel Accessory Kit – iPC A2UBEZEL ..................................................................................................................................................................................... 65
5.7.2 1U Front Bezel Accessory Kit – iPC A1UBEZEL ..................................................................................................................................................................................... 66
5.8 1U / 2U PCIe* Riser Card Accessory/Spare FRU Options .................................................................................................................................................................................67
5.8.1 1U Riser Card Options ..................................................................................................................................................................................................................................... 67
5.8.2 2U Riser Card Options ..................................................................................................................................................................................................................................... 68
5.9 Intel® I/O Expansion Modules .......................................................................................................................................................................................................................................69
5.10 Intel® SAS RAID Add-in Cards, Modules, and Accessories................................................................................................................................................................................72
5.10.1 Intel® Integrated RAID Module RMS3 Product Family – SAS 3.0 (12 Gb/s) ............................................................................................................................... 73
5.10.2 Intel® RAID Accessory Options .................................................................................................................................................................................................................... 79
5.11 Intel® PCI Express NVMe Add-in Cards .....................................................................................................................................................................................................................81
5.12 Intel Power Supply Modules and Power Cords .....................................................................................................................................................................................................82
5.13 1U / 2U Rack Mount Kits .................................................................................................................................................................................................................................................83
5.13.1 iPC - AXXPRAIL................................................................................................................................................................................................................................................... 83
5.13.2 iPC – AXXELVRAIL ............................................................................................................................................................................................................................................. 83
5.13.3 iPC – AXX1U2UCMA ......................................................................................................................................................................................................................................... 83
iPC - AXX2POSTBRCKT ..................................................................................................................................................................................................................................................... 84
vii
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.13.4 Intel® Xeon Phi™ Coprocessor Card and Non-Intel GPGPU Support............................................................................................................................................ 85
iPC – AWTCOPRODUCT ..................................................................................................................................................................................................................................................... 87
iPC – A2UL16RISER2 ........................................................................................................................................................................................................................................................... 87
5.14 Intel® I/O Expansion Add-in Cards ..............................................................................................................................................................................................................................88
iPC – 100HFA016LS............................................................................................................................................................................................................................................................. 88
viii
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
List of Tables
Table 1. Product Family Reference Collaterals .................................................................................................................................................................................................................... 2
Table 2. Server Board Product Family Summary ................................................................................................................................................................................................................ 6
Table 3. Server Chassis & Server/Storage System Product Family Summary ....................................................................................................................................................... 6
Table 4. 1U / 2U Server System Product Family Generation to Generation Transition Guide ........................................................................................................................ 1
Table 5. 1U / 2U Building Block to Integrated System Recipe Guide ......................................................................................................................................................................... 3
Table 6. 2U 12 x 3.5” – R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander) ............................................................................................................................ 35
Table 7. 2U 8 x 2.5" (Drive Bay #1) - SAS/SATA Data Cable Guid (with no SAS Expander) ............................................................................................................................ 39
Table 8. 2U 8 x 2.5” (Drive Bay #2) – SAS / SATA Data Cable Guide (with no SAS Expander) ...................................................................................................................... 40
Table 9. 2U 8 x 2.5” (Drive Bay #3) – SAS / SATA Data Cable Guide (with no SAS Expander) ...................................................................................................................... 41
Table 10. 2U 2.5” Front Mount Drive Configurations with SAS Expander – SAS Data Cable Guide .......................................................................................................... 43
Table 11. Storage Data Cable Kit Description and Order Information .................................................................................................................................................................... 46
Table 12. 1U 8x2.5" Combo Backplane SAS/SATA Cable Guide ............................................................................................................................................................................... 51
ix
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
The Intel® S2600WT product family is offered as both building block options and integrated systems. The product family consists of the following:
The Intel® Server S2600WT product family supports the following processors and memory:
• Intel® Xeon® processor E5-2600 v3 & v4 product families
1
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel® Server Board S2600WT Product Family Power Budget Tool and Thermal Configuration Guide
For system power budget guidance
https://downloadcenter.intel.com/product/78562/Intel-Server-Board-S2600WT-Family
For system firmware updates, onboard device drivers,
https://downloadcenter.intel.com/product/78562/Intel-Server-Board-S2600WT-Family
and software to manage your Intel® Server System.
For a complete list of supported processors, memory, http://www.intel.com/content/www/us/en/motherboards/server-motherboards/server-board-
add-in cards, and peripherals: s2600wt.html?wapkw=s2600wt+product+family
Product Warranty Information http://www.intel.com/content/www/us/en/support/services/000005886.html
2
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
1.1 Intel® S2600WT Server Chassis and Server System Product Code Naming Convention
Drive Server # of Power Supports for
Chassis Form both Intel® Xeon®
Board Supplies processor E5-
Type Factor Identifier Included 2600 v3 and v4
product families
Intel® Server Chassis
R 2 2 08 WTT Y C 1 R
Intel® Server System
U Height # of Power Special
Drives Supply System SKU
Type
Chassis Type Server Board Identifier
WT = Intel® Server Board S2600WT product family supported
R = RACK MOUNT WT2 = Intel® Server Board S2600WT w/1 GbE LOM – iPC S2600WT2
WTT = Intel® Server Board S2600WT w/10 GbE LOM – iPC S2600WTT
U Height Power Supply Type Included
1 = 1U X = None Included
2 = 2U G = 750W
Y = 1100W
Drive Form Factor # of Power Supplies Included
(Specific to front drive bays) X = None
0 = No drives supported S = 1 (Non-redundant)
2 = 2.5” C = 2 (Redundant)
3 = 3.5”
# of Drives Supported Special System SKU
(Specific to front drive bays) # = a sequential number starting with 1 within the product family, identifying a special
00 12 system SKU that adds a non-standard feature from other offered system SKUs. This
04 16 last digit may or may not be present on all offered system SKUs.
08 24
Note: 00 product codes have no front mount drive bays. Hot swap drive
support can be added with the addition of available drive bay accessory
options.
3
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
4
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
The S2600WTTR SKU offers a LAN on Motherboard (LOM) option supporting dual RJ45 10Gb Base-T LAN ports.
The S2600WT2R SKU offers a LAN on Motherboard (LOM) option supporting dual RJ45 1Gb Base-T LAN ports.
The S2600WTTCR SKU offers a LAN on Motherboard (LOM) option supporting dual RJ45 10Gb Base-T LAN ports and Intel® Platform Firmware
Resilience Technology (PFR) and Asset Protect-In-Transit.
The following tables provides an overview of available Intel product codes for building blocks and systems within the Intel® S2600WT product
family. Each line item identifies key features supported in the shipping Intel SKU. Additional order code information and full product descriptions
for each option are provided in later sections.
Table 2. Server Board Product Family Summary
# of SATA SW
# of CPU # of Riser Onboard RJ45 # of SATA ports Intel® I/O Intel® SAS RAID Module
Intel Product Code DIMM RAID
sockets Slots LAN ports (6 Gb) Module Support support
Slots Support
Server Board only
S2600WT2R 2 24 3 2 (1 Gb) 10 Yes Yes Yes
S2600WTTR 2 24 3 2 (10 Gb) 10 Yes Yes Yes
S2600WTTCR 2 24 3 2 (10 Gb) 10 Yes Yes Yes
Table 3. Server Chassis & Server/Storage System Product Family Summary
Chassis Drive # of # of # of PCIe*
Power Supply SAS SAS PCIe* SFF
Intel Product Code Form Form Drives Drives Add-in Card 3rd Riser Rails
Modules RAID Expander SSD / NVMe
Factor Factor (front) 1 (rear) Slots
Chassis Only (KDK)
R1304WTXXX 1U 3.5” 4 na opt na opt opt opt na na
R1208WTXXX 1U 2.5” 8 na opt na opt opt opt na opt
R2312WTXXX 2U 3.5” 12 opt opt opt opt opt opt opt na
2
R2000WTXXX 2U opt opt opt opt opt opt opt opt opt opt
2x 10G LOM System
(L6 BIK)
R1304WTTGSR 1U 3.5” 4 na 2 na 1x 750W AC opt opt na na
R1208WTTGSR 1U 2.5” 8 na 2 na 1x 750W AC opt opt na opt
R2208WTTYSR 2U 2.5” 8 opt 8 yes 1x 1100W AC opt opt na opt
R2308WTTYSR 2U 3.5” 8 opt 8 yes 1x 1100W AC opt opt na na
R2312WTTYSR 2U 3.5” 12 2 6 opt 1x 1100W AC opt opt opt na
6
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Chassis Drive # of # of # of PCIe*
Power Supply SAS SAS PCIe* SFF
Intel Product Code Form Form Drives Drives Add-in Card 3rd Riser Rails
Modules RAID Expander SSD / NVMe
Factor Factor (front) 1 (rear) Slots
R2224WTTYSR 2U 2.5” 24 2 6 opt 1x 1100W AC opt opt opt opt
3
R2208WTTYC1R 2U 2.5” 8 opt 6 yes 2x 1100W AC opt opt na opt
2x 1G LOM System
(L6 BIK)
R1304WT2GSR 1U 3.5” 4 na 2 na 1x 750W AC opt opt na na
R1208WT2GSR 1U 2.5” 8 na 2 na 1x 750W AC opt opt na opt
R2208WT2YSR 2U 2.5” 8 opt 8 yes 1x 1100W AC opt opt na opt
7
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
1.3 Intel® S2600GZ/GL Product Family to Intel® Server S2600WT Product Family Transition Guide
If transitioning from the previous generation Intel® S2600GZ/GL product family, the following table can be used to identify an equivalent system
within the Intel® S2600WT product family.
Table 4. 1U / 2U Server System Product Family Generation to Generation Transition Guide
New
Prior New Generation
Generation 1G
Generation 10G LOM SKU Required accessories to match configuration Advantages included in current generation
LOM SKU
Product Code Product Code
Product Code
AXXRMM4LITE
R1208GL4DS R1208WT2GSR R1208WTTGSR AXXELVRAIL AXXRMM4LITE2 750 vs460 PSU, 24 vs16DIMM
AXXRMM4LITE
R1208GZ4GC R1208WT2GSR R1208WTTGSR AXXELVRAIL AXXRMM4LITE2 FXX750PCRPS
R1208GZ4GS9 R1208WT2GSR R1208WTTGSR
R1304GL4DS9 R1304WT2GSR R1304WTTGSR 750 vs460 PSU, 24vs16DIMM
AXXRMM4LITE
R1304GZ4GC R1304WT2GSR R1304WTTGSR AXXELVRAIL AXXRMM4LITE2 FXX750PCRPS
R1304GZ4GS9 R1304WT2GSR R1304WTTGSR
Rear drives option, 1100W vs 460W PSU, 3rd riser, 24vs16
R2208GL4DS9 R2208WT2YSR R2208WTTYSR dimms
AXXRMM4LITE Rear drives option, 1100W vs 750W PSU, 3rd riser, 24vs16
R2208GL4GS R2208WT2YSR R2208WTTYSR AXXELVRAIL AXXRMM4LITE2 dimms
AXXRMM4LITE
R2208GZ4GC R2208WT2YSR R2208WTTYSR AXXELVRAIL AXXRMM4LITE2 AXX1100PCRPS Rear drives option, 1100W vs 750W PSU, 3rd riser
R2208GZ4GS9 R2208WT2YSR R2208WTTYSR Rear drives option, 1100W vs 750W PSU, 3rd riser
AXXRMM4LITE
R2224GZ4GC4 R2224WTTYSR AXXELVRAIL AXXRMM4LITE2 Rear drives included, 1100W vs 750W PSU, 3rd riser optional
AXXRMM4LITE Rear drives option, 1100W vs 750W PSU, 3rd riser, 24vs16
R2308GL4GS R2308WTTYSR AXXELVRAIL AXXRMM4LITE2 dimms
AXXRMM4LITE
R2308GZ4GC R2308WTTYSR AXXELVRAIL AXXRMM4LITE2 AXX1100PCRPS Rear drives option, 1100W vs 750W PSU, 3rd riser
R2308GZ4GS9 R2308WTTYSR Rear drives option, 1100W vs 750W PSU, 3rd riser
AXXRMM4LITE Rear drives included, 1100W vs 750W PSU, 3rd riser optional,
R2312GL4GS R2312WTTYSR AXXELVRAIL AXXRMM4LITE2 24vs16 dimms
AXXRMM4LITE
R2312GZ4GC4 R2312WTTYSR AXXELVRAIL AXXRMM4LITE2 AXX1100PCRPS Rear drives included, 1100W vs 750W PSU, 3rd riser optional
R2312GZ4GS9 R2312WTTYSR Rear drives included, 1100W vs 750W PSU, 3rd riser optional
1
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
2
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
3
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
2
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
• Intel® Remote Management Module 4 Lite
The first column in the table identifies the available integrated system SKUs. The columns to the right of a specified system SKU identify the Intel
building block kits required to assemble the equivalent system.
3
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC) Order Information Product Description Product Type
®
Intel Server Board S2600WT2R
• Support for 1 or 2 Intel® Xeon processor E5-2600 v3 or v4 product family
MM# - 943786 • Maximum supported TDP for board 145W (not available in all chassis configurations)
UPC - 00735858308618 • Intel® C612 chipset
EAN - 5032037081375 • 24 DDR4 DIMM Slots
iPC – S2600WT2R MOQ - 1 • 8 AHCI SATA 6Gb ports thru two 4-port SFF-8643 connectors
• AHCI SATA 6Gb ports for ODD, DOM, SSD thru two 7-pin SATA connectors
• 2 Integrated 1Gb ports (Intel® Ethernet Controller I350) Server Board only
4
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC) Order Information Product Description Product Type
®
Intel Server Board S2600WTTR
• Support for 1 or 2 Intel® Xeon processor E5-2600 v3 or v4 product family
• Maximum supported TDP for board 145W (not available in all chassis configurations)
MM# - 943785 • Intel® C612 chipset
UPC - 00735858308601 • 24 DDR4 DIMM Slots
EAN - 5032037081368 • 8 AHCI SATA 6Gb ports thru two 4-port SFF-8643 connectors
iPC – S2600WTTR MOQ - 1 • AHCI SATA 6Gb ports for ODD, DOM, SSD thru two 7-pin SATA connectors
• 2 Integrated 10Gb ports (Intel® Ethernet Controller X-540) Server Board Only
• Integrated Baseboard Management controller with IPMI 2.0 support
• Optional advanced management features activated by AXXRMM4LITE key or • Building block
AXXRMM4LITE2 RoHS free key option
Packaged Gross Weight
• Dedicated 1Gb management port • Spare FRU
3.1 Kgs, 6.8 Lbs
• Support for up to 3 riser cards with multiple Intel riser card options
Un-packaged Net Note: 2 CPUs required for riser #2 and riser #3 support
Weight • Support for Intel® I/O expansion module option
1.7 Kgs, 3.8 Lbs • Support for Intel® SAS module option
5
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC) Order Information Product Description Product Type
®
Intel Server Board S2600WTTS1R
• Support for 1 or 2 Intel® Xeon processor E5-2600 v3 or v4 product family
• Maximum supported TDP for board 145W (not available in all chassis configurations)
MM# - 949339 • Intel® C612 chipset
UPC - 735858315463 • 24 DDR4 DIMM Slots
EAN - 5032037086462 • 8 AHCI SATA 6Gb ports thru two 4-port SFF-8643 connectors
iPC – MOQ - 1 • AHCI SATA 6Gb ports for ODD, DOM, SSD thru two 7-pin SATA connectors
S2600WTTS1R • 2 Integrated 10Gb ports (Intel® Ethernet Controller X-540)
• Integrated Baseboard Management controller with IPMI 2.0 support Server Board Only
6
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
2.3 Intel® Server Chassis R1000WT Product Family SKUs – (1U Rack Mount Chassis)
The product tables found in this section provide order code information and detailed descriptions for each available 1U Intel server chassis building
block option. The lower sections of each table identify:
• The ship along components of the specified chassis product code – (product BOM)
• Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set.
• Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis.
Additional accessories can be found in Chapter 5.
Note:
• Each required item and optional accessory is sold separately from the specified Intel server building block.
• Items identified as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU.
• In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by
description and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or
accessory.
Figure 3. Intel® Server Chassis R1000WT – 1U Chassis only Building Block (KDK)
7
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC): Order Code Information:
Product Type: Chassis Only
MM# - 936121
Chassis Form Factor: 1U rack mount
R1304WTXXX UPC - 00735858287944 Chassis dimensions: L=712mm, W=439mm, H=43.2mm
EAN - 5032037067492 Packaged Gross Weight: 19 Kgs, 41.9 Lbs
MOQ - 1 Un-packaged Net Weight: 10.3 Kgs, 22.7 Lbs
1U – 4 x 3.5” HDD or 4 x 2.5” SSD front mount drives Outer Box Dimensions: L=983mm, W=577mm, H=260mm
8
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC): Order Code Information:
Product Type: Chassis Only
MM# - 936187
Chassis Form Factor: 1U rack mount
R1208WTXXX UPC - 00735858287951 Chassis dimensions: L=712mm, W=439mm, H=43.2mm
EAN - 5032037067508 Packaged Gross Weight: 19 Kgs, 41.9 Lbs
MOQ - 1 Un-packaged Net Weight: 10.3 Kgs, 22.7 Lbs
1U – 8 x 2.5” front mount drives Outer Box Dimensions: L=983mm, W=577mm, H=260mm
9
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
2.4 Intel® Server Chassis R2000WT Product Family SKUs – (2U Rack Mount Chassis)
The product tables found in this section provide order code information and detailed descriptions for each available 2U Intel server chassis building
block option. The lower sections of each table identify:
• The ship along components of the specified chassis product code – (product BOM)
• Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set
• Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis.
Additional accessories can be found in Chapter 5
Notes:
• Each required item and optional accessory is sold separately from the specified Intel server building block
• Items identified as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
• In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by
description and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or
accessory.
Figure 4. Intel® Server Chassis R2000WT – 2U Chassis only Building Block (KDK)
10
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC): Order Code Information:
MM# - 936022 Product Type: Chassis only
2.4.1 R2312WTXXX UPC - 00735858288729 Chassis Form Factor: 2U rack mount
EAN - 5032037068000 Chassis dimensions: L=712mm, W=439mm, H=89mm
MOQ - 1 Packaged Gross Weight: 21.2 Kgs, 46.7 Lbs
Un-packaged Net Weight: 14.4 Kgs, 32.0 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
2U – 12 x 3.5” HDD or 12 x 2.5” SSD front mount drives
11
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
12
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
options
• Intel® SAS RAID Card / Module – See section 5.10 for options
• Intel SAS Expander Options – See sections 4.2.4.2 & 4.2.5.2
• Intel® I/O Module – See chapter 5.9 for options
• iPC A2UBEZEL – Lockable front system bezel
• iPC AXXRMM4LITE – Intel® Remote Management Module Lite
• iPC AXXRMM4LITE2 – Intel® Remote Management Module
Lite, “RoHS free”, key for advanced management features
13
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
14
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
3.1 Intel® Server/Storage System R1000WT Product Family SKUs – (1U Rack Mount System)
The product tables found in this section provide order code information and detailed descriptions for the specified L6 integrated 1U Intel server system.
The lower sections of each table identify:
• The ship along components of the specified system product code – (product BOM)
• Required Items – Hardware required to be installed to the base system to achieve basic functionality using the default system feature set
• Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis. A
full list of accessory options can be found in Chapter 5
Notes:
• Each required item and optional accessory is sold separately from the specified Intel L6 or L8 server system
• Items identified as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU
• In an effort to provide the complete product bill of materials, the ship along components listed in each product table will include items identified by
description and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or
accessory.
15
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code (iPC): Order Code Information:
Product Type: L6 Integrated System
MM# - 943891
R1304WTTGSR Chassis Form Factor: 1U rack mount
UPC – 00735858300865
Chassis dimensions: L=712mm, W=439mm, H=43.2mm
EAN – 5032037075954 Packaged Gross Weight: 21.3 Kgs, 47.0 Lbs
MOQ – 1 Un-packaged Net Weight: 12.3 Kgs, 27.1 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
1U – 4 x 3.5” HDD or 4 x 2.5” SSD SAS/SATA front mount drives
16
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC): Order Code Information:
Product Type: L6 Integrated System
MM# – 943892
R1304WT2GSR Chassis Form Factor: 1U rack mount
UPC – 00735858300872
Chassis dimensions: L=712mm, W=439mm, H=43.2mm
EAN – 5032037075961 Packaged Gross Weight: 21.3 Kgs, 47.0 Lbs
MOQ – 1 Un-packaged Net Weight: 12.3 Kgs, 27.1 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
1U – 4 x 3.5” HDD or 4 x 2.5” SSD SAS/SATA front mount drives
17
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC): Order Code Information:
Product Type: L6 Integrated System
MM# – 943893
R1208WTTGSR Chassis Form Factor: 1U rack mount
UPC – 00735858300889
Chassis dimensions: L=712mm, W=439mm, H=43.2mm
EAN – 5032037075978 Packaged Gross Weight: 21.1 Kgs, 46.5 Lbs
MOQ – 1 Un-packaged Net Weight: 12.9 Kgs, 28.4 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
1U – 8 x 2.5” SAS/SATA front mount drives
(1) – 730mm SAS/SATA Multiport data cable – iPC AXXCBL730HRHD • iPC A1UBEZEL – Lockable front system bezel
(1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL800HRHD • iPC AXXRMM4LITE - Intel® Remote Management
(1) – Backplane power cable – iPN H38458-00x Module Lite key – For advanced management
(1) – 200mm Backplane I2C cable – iPN H23846-00x features
(2) – CPU heatsink – iPC FXXCA84X106HS • iPC AXXRMM4LITE2 - Intel® Remote Management
(8) – DIMM slot blanks – iPN G75158-00x “RoHS free”
(2) – Chassis handle (1 set) installed - iPN H19171-00x
• iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID
Spares for each screw type included
5 support key
• Storage Drives
18
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
(1) – 730mm SAS/SATA Multiport data cable – iPC AXXCBL730HRHD • iPC A1UBEZEL – Lockable front system bezel
(1) – 800mm SAS/SATA Multiport data cable – iPC AXXCBL800HRHD • iPC AXXRMM4LITE - Intel® Remote Management
(1) – Server board to backplane power cable – iPN H38458-00x Module Lite key – For advanced management
(1) – Server board to backplane I2C cable – iPN H39941-00x features
(2) – CPU heatsink – iPC FXXCA84X106HS • iPC AXXRMM4LITE2 - Intel® Remote Management
(8) – DIMM slot blanks – iPN G75158-00x “RoHS free”
(2) – Chassis handle (1 set) installed – iPN H19171-00x
• iPC RKSATA4R5 – Embedded SATA ESRT2 SW RAID
Spares for each screw type included
5 support key
• Storage Drives
19
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
3.2 Intel® Server System R2000WT Product Family SKUs – (2U Rack Mount System)
The product tables found in this section provide order code information and detailed descriptions for the specified L6 integrated 2U Intel server system.
The lower sections of each table identify:
• The ship along components of the specified chassis product code – (product BOM)
• Required Items – The options required to be installed to the base system to achieve basic functionality using the default system feature set
• Optional Accessories – Some of the available accessories which can be installed to enhance the basic feature set of the server board / chassis.
Additional accessories can be found in Chapter 5
Notes:
• Each required item and optional accessory is sold separately from the specified Intel L6 server system.
• Items identified as iPC (Intel Product Code), are an orderable building block option, accessory or spare FRU.
• In an effort to provide the complete product bill of materials, the ship along components list in each product table will include items identified by
description and by iPN (Intel Part Number). The iPN information is provided for reference only. These components are not orderable as a spare or
accessory.
20
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC):
Order Code Information: Product Type: L6 Integrated System
3.2.1 R2208WT2YSR MM# – 943827 Chassis Form Factor: 2U rack mount
UPC – 00735858300919 Chassis dimensions: L=712mm, W=439mm, H=89mm
EAN – 5032037076005 Packaged Gross Weight: 22.9 Kgs, 50.5 Lbs
MOQ – 1
Un-packaged Net Weight: 16.2 Kgs, 35.7 Lbs
Outer Box Dimensions: L=983mm, W=577mm, H=260mm
2U – 8 x 2.5” front mount drives
21
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC):
Order Code Product Type: L6 Integrated System
3.2.2 R2208WTTYSR Information: Chassis Form Factor: 2U rack mount
MM# – 943826 Chassis dimensions: L=712mm, W=439mm, H=89mm
UPC – 00735858300902 Packaged Gross Weight: 22.9 Kgs, 50.5 Lbs
EAN – 5032037075992 Un-packaged Net Weight: 16.2 Kgs, 35.7 Lbs
MOQ – 1 Outer Box Dimensions: L=983mm, W=577mm, H=260mm
2U – 8 x 2.5” front mount drives
22
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
23
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
See Chapter 5 for all available accessory options.
24
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC):
Order Code Product Type: L6 Integrated System
Information:
R2312WTTYSR Chassis Form Factor: 2U rack mount
MM# – 943830 Chassis dimensions: L=712mm, W=439mm, H=89mm
UPC – 00735858300940 Packaged Gross Weight: 24.4 Kgs, 53.8 Lbs
EAN – 5032037076036 Un-packaged Net Weight: 17.0 Kgs, 37.5 Lbs
MOQ – 1 Outer Box Dimensions: L=983mm, W=577mm, H=260mm
2U – 12 x 3.5” HDD or 12 x 2.5” SSD front mount drives
25
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Product Code (iPC):
Order Code Product Type: L6 Integrated System
R2224WTTYSR Information:
Chassis Form Factor: 2U
MM# – 943831 Chassis dimensions: L=712mm, W=439mm, H=89mm
UPC – 00735858300957 Packaged Gross Weight: 25.0 Kgs, 55.1 Lbs
EAN – 5032037076043 Un-packaged Net Weight: 18.3 Kgs, 40.3 Lbs
MOQ – 1 Outer Box Dimensions: L=983mm, W=577mm, H=260mm
2U – 24 x 2.5” front mount drives
26
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Image Description
7-pin Single Port SATA
Support for up to 6 GB/sec SATA devices
Where used:
• On the server board – (2) single port SATA connectors (SATA 4, SATA 5)
• 2U Rear Mount Hot-Swap Backplane (iPC A2UREARHSDK)
• SATA Optical Drive – CD/DVD
• SATA DOM
Image Description
SFF-8643
• Support for up to 12 Gb/Sec SAS and 6 Gb/sec SATA devices
• PCIe* (NVMe) SFF support associated with Intel Accessory Kits A1U44X25NVMEDK
& A2U44X25NVMEDK
Where used:
• On the server board – (2) 4-port SATA connectors (SATA 0-3, sSATA 0-3)
• All 12 Gb/sec SAS capable hot swap backplanes
• All 12 Gb/sec SAS RAID Controllers
• All 12 Gb/sec SAS Expander Cards
27
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Multiport MiniSAS Connector
Image Description
SFF-8087
Support for up to 6 Gb/Sec SAS / SATA devices
Where used:
• All 6 Gb/sec SAS RAID Controllers
• All 6 Gb/sec SAS Expander Cards
When connecting a 6Gb/sec SAS Controller or SAS Expander to a 12 Gb/sec capable hot swap backplane, the data cables used will need a SFF-8643
connector on one end of the cable and a SFF-8087 connector on the other. See Table 11. Storage Data Cable Kit Description and Order Information for
appropriate cable kits.
MS = Straight SFF-8087 Mini SAS Connector (compatible with 6Gb/sec SAS controllers and expanders)
28
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
System illustrations in each of the following sections will denote drive numbering as shown below:
Drive numbering in the system illustrations is for general reference only. Actual drive numbering will be dependent on SAS / SATA controller
configuration and how they are cabled to the backplane. Each installed backplane will include a multi-port data connector for each set of four drives.
Example for an 8 drive configuration (as shown above), the backplane will include 2 four-port data connectors. In the illustration, drives showing a
common color for the Drive ID label will share a common data connector on the backside of the backplane.
Each table in the following sections identify the cable connections and recommended cable lengths for each supported storage controller option in the
specified system. Each “recommended” cable length for a given connector pair provides enough cable to attach the two devices and provides the least
amount of access cable, providing the cleanest cable routing.
In the given server system, no cables should be routed in front of the system fans or in between the processors and memory slots. All cables that require
routing from the front of the system to the back, are routed within the cable channels along the chassis sidewalls.
29
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Cables for On-board Cables for Mezzanine Cables for Mezzanine Cables for 12 Gb SAS Cables for 6 Gb SAS RAID
System
Drive Support Multi-port SATA Ports 12 Gb SAS ROC 6 Gb SAS RAID RAID PCIe* add-in card to PCIe* add-in card to
Configuration
to Backplane Module to Backplane module to Backplane Backplane Backplane
Cable Connections: Cable Connections: Cable Connections: From Riser #1 From Riser #1
SAS Mezz -> BP 0-3 Cable Connections: Cable Connections:
SATA -> BP 0-3 SAS Mezz -> BP 0-3 800 mm HD --- MS SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
800 mm HR --- HD 800 mm HD --- HD 875 or 950 mm HD --- HD 875 or 950 mm HD --- MS
From data above,
From data above, From data above, select appropriate From Riser #2 From Riser #2
select appropriate select appropriate cable kit from list
Cable Connections: Cable Connections:
cable kit from list cable kit from list below:
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
R1304WTxxx 4 x 3.5” below: below:
730 or 875 mm HD --- HD 730 or 875 mm HD --- MS
R1304WTTGSR 12 Gb SAS AXXCBL800HDMS
capable AXXCBL1UHRHD AXXCBL800HDHD
R1304WT2GSR From data above, select From data above, select
appropriate cable kits appropriate cable kits
Cable included with
from list below: from list below:
L6 Integrated systems
See ** note below See ** note below
AXXCBL730HDHD AXXCBL730HDMS
AXXCBL875HDHD AXXCBL875HDMS
AXXCBL950HDHD AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
30
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: For data cable information associated with Intel® Accessory Kit A2U44X25NVMEDK, see section 5.1.1
Cables for
Cables for On-board Cables for Mezzanine Cables for 12 Gb SAS Cables for 6 Gb SAS RAID
System Mezzanine 12 Gb SAS
Drive Support Multi-port SATA Ports 6 Gb SAS RAID RAID PCIe* add-in card to PCIe* add-in card to
Configuration ROC Module to
to Backplane module to Backplane Backplane Backplane
Backplane
Cable Connections: Cable Connections: Cable Connections: From Riser #1 From Riser #1
SATA -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 Cable Connections: Cable Connections:
730 mm HR --- HD 650 mm HD --- HD 650 mm HD --- MS SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
650 mm HD --- HD 650 mm HD --- MS
sSATA -> BP 4-7 SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7 SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
800 mm HR --- HD 800 mm HD --- HD 800 mm HD --- MS 730 or 800 mm HD --- HD 730 or 800 mm HD --- MS
From data above, From data above, From data above, From Riser #2 From Riser #2
select appropriate select appropriate select appropriate
Cable Connections: Cable Connections:
cable kits from list cable kits from list cable kits from list
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
R1208WTxxx 8 x 2.5” below: below: below:
650 or 730mm HD --- HD 650 or 730mm HD --- MS
R1208WTTGSR 12 Gb SAS SAS PCIe – BP 4-7 ** SAS PCIe – BP 4-7 **
capable AXXCBL1UHRHD AXXCBL650HDHD AXXCBL650HDMS
R1208WT2GSR AXXCBL800HDHD AXXCBL800HDMS
800 or 875 mm HD --- HD 800 or 875 mm HD --- MS
1 of each cable
From data above, select From data above, select
included with L6
appropriate cable kits appropriate cable kits
Integrated systems
from list below: from list below:
See ** notes below See ** notes below
AXXCBL650HDHD AXXCBL650HDMS
AXXCBL730HDHD AXXCBL730HDMS
AXXCBL800HDHD AXXCBL800HDMS
AXXCBL875HDHD AXXCBL875HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
31
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Cables for
Cables for On-board Cables for Mezzanine Cables for 12 Gb SAS RAID Cables for 6 Gb SAS RAID
System Mezzanine 12 Gb
Drive Support Multi-port SATA 6 Gb SAS RAID PCIe* add-in card to PCIe* add-in card to
Configuration SAS ROC Module to
Ports to Backplane module to Backplane Backplane Backplane
Backplane
Cable Connections: Cable Connections: Cable Connections: From Riser #1: From Riser #1
SATA -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 Cable Connections: Cable Connections:
800 mm HD --- HD 800 mm HD --- HD 800 mm HD --- MS SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
650 or 730 mm HD --- HD 650 or 730 mm HD --- MS
sSATA -> BP 4-7 SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7 SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
950 mm HD --- HD 950 mm HD --- HD 950 mm HD --- MS 800 or 950 mm HD --- HD 800 or 950 mm HD --- MS
From data above, select From Riser #2: From Riser #2:
From data above, From data above, appropriate cable kits
Cable Connections: Cable Connections:
select appropriate select appropriate from list below:
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
cable kits from list cable kits from list
8 x 3.5” 730 or 800 mm HD --- HD 730 or 800 mm HD --- MS
below: below: AXXCBL800HDMS
R2308WTTYSR 12 Gb SAS AXXCBL950HDMS
SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
730 or 800 mm HD --- HD 730 or 800 mm HD --- MS
Capable AXXCBL800HDHD AXXCBL800HDHD
AXXCBL950HDHD AXXCBL950HDHD
From data above, select From data above, select
appropriate cable kits from list appropriate cable kits from
1 of each cable 1 of each cable
below: list below:
included with L6 included with L6
See ** Notes below See ** Notes below
Integrated systems Integrated systems
AXXCBL650HDHD AXXCBL650HDMS
AXXCBL730HDHD AXXCBL730HDMS
AXXCBL800HDHD AXXCBL800HDMS
(1) 800mm Included in L6 AXXCBL950HDMS
AXXCBL950HDHD
(1) 950mm Included in L6
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
32
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
4.2.4.1 2U 12 x 3.5” - R2312WTxxx SAS / SATA Data Cable Guide (with No SAS Expander)
sSATA Cntrl -> BP 4-7 SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7 From Riser #1 From Riser #1
875 mm HD --- HD 875 mm HD --- HD 875 mm HD --- MS SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
800 or 875 mm HD --- HD 800 or 875 mm HD --- MS
SAS Mezz -> BP 8-11 SAS Mezz -> BP 8-11 SAS PCIe -> BP 8-11 SAS PCIe -> BP 8-11
From data above, select 950 mm HD ---HD 950 mm HD ---MS 875 mm HD ---HD 875 mm HD ---MS
appropriate cable kits
from list below: From data above, select From data above, select From Riser #2 From Riser #2
R2312WTxxx 12 x 3.5” appropriate cable kits appropriate cable kits
SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
R2312WTTYSR 12 Gb SAS AXXCBL800HDHD from list below: from list below:
730 or 875 mm HD --- HD 730 or 875 mm HD --- MS
Capable AXXCBL875HDHD
SAS PCIe -> BP 8-11 ** SAS PCIe -> BP 8-11 **
AXXCBL800HDHD AXXCBL800HDHD
650 or 800 mm HD --- HD 650 or 800 mm HD --- MS
1 of each cable AXXCBL875HDHD (1) 800mm Included in L6
included with L6 AXXCBL950HDHD AXXCBL875HDMS
From data above, select From data above, select
Integrated systems AXXCBL950HDMS
appropriate cable kits: appropriate cable kits from
1 of each cable
See ** Notes below list below:
included with L6
AXXCBL650HDHD See ** Notes below
Integrated systems
AXXCBL730HDHD
AXXCBL800HDHD AXXCBL650HDMS
(1) 800mm Included in L6 AXXCBL730HDMS
AXXCBL875HDHD AXXCBL800HDMS
(1) 875mm Included in L6 AXXCBL875HDMS
AXXCBL950HDHD AXXCBL950HDMS
(1) 950mm included in L6)
33
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
** 1 or 2 cable lengths may be specified for a PCIe* add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
4.2.4.2 2U 12 x 3.5” - R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander)
SAS drive configurations consisting of more than 8 drives may require the addition of a SAS Expander card. In the 2U 12x3.5” system configuration, the
SAS expander must be installed in any available PCIe* add-in slot. Intel provides two SAS expander options to support this drive configuration:
34
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: The onboard SATA ports are not compatible with SAS Expander cards. The onboard SATA ports can only be cabled directly to a specified
backplane.
Table 6. 2U 12 x 3.5” – R2312WTxxx SAS / SATA Data Cable Guide (with SAS Expander)
Mezzanine 12Gb SAS Mezzanine 6 Gb SAS
12Gb SAS RAID PCIe* 6Gb SAS RAID PCIe*
System On-board Multi-port ROC Module + 12 Gb ROC module + 6 Gb
Drive Support add-in card + 12 Gb SAS add-in card + 6 Gb SAS
Configuration SATA Ports SAS Expander to SAS Expander to
Expander to Backplane Expander to Backplane
Backplane Backplane
Onboard SATA With 12 Gb SAS With 6 Gb SAS With 12 Gb PCIe RAID With 6 Gb PCIe RAID
controllers do not Expander RES3FV288 Expander RES2SV240 and 12 Gb SAS Expander and 6 Gb SAS Expander
support SAS installed in Riser #1: installed in Riser #1: RES3FV288 installed in RES2SV240 installed in
expanders. riser #1: riser #1:
- Use cables in - Use cables in
If attaching the Expander Kit to Expander Kit to - Use cables in - Use cables in
onboard SATA attach SAS ROC to attach SAS ROC to Expander Kit to attach Expander Kit to attach
controller to the Expander Card Expander Card PCIe SAS card to PCIe SAS card to
Backplane, then use - Use the - Use the Expander Card Expander Card
R2312WTxxx cables that are included following cables to following cables to - Use the - Use the
12 x 3.5” in the System SKUs. attach Expander to attach Expander to following cables to following cables to
R2312WTTYSR 12 Gb SAS Capable Backplane: Backplane: attach Expander to attach Expander to
For building block Backplane: Backplane:
integration use cable Expander -> BP 0-3 Expander -> BP 0-3
kits: 800 mm HD --– HD 800 mm HD --– MS Expander -> BP 0-3 Expander -> BP 0-3
AXXCBL800HDHD 800 mm HD --– HD 800 mm HD --– MS
AXXCBL875HDHD Expander -> BP 4-7 Expander -> BP 4-7
875 mm HD --- HD 875 mm HD --- MS Expander -> BP 4-7 Expander -> BP 4-7
875 mm HD --- HD 875 mm HD --- MS
Expander -> BP 8-11 Expander -> BP 8-11
950 mm HD ---HD 950 mm HD ---MS Expander -> BP 8-11 Expander -> BP 8-11
950 mm HD ---HD 950 mm HD ---MS
1 of each cable From data above,
35
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
included with L6 select appropriate From data above, select From data above, select
Integrated systems cable kits from list appropriate cable kits appropriate cable kits
below: from list below: from list below:
From data above,
select appropriate AXXCBL800HDMS AXXCBL800HDHD AXXCBL800HDMS
cable kits from list AXXCBL875HDMS AXXCBL875HDHD AXXCBL875HDMS
below: AXXCBL950HDMS AXXCBL950HDHD AXXCBL950HDMS
AXXCBL800HDHD
AXXCBL875HDHD
AXXCBL950HDHD
36
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
37
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel makes available several different 8x2.5” drive bay module options, each supporting a different feature set (see chapter 5). The system tables in this
section define the SAS/SATA data cables required to support the specified drive bay location regardless of the backplane option installed.
Reference each table as appropriate to determine the cable requirements relevant to your specific drive bay configuration.
Note: For data cable information associated with Intel® Accessory Kit A2U44X25NVMEDK, see sections 5.2.1 and 5.2.2
38
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
4.2.5.1 2U 2.5” Front Mount Drive Configurations – SAS Data Cable Guide (with no SAS Expander)
Table 7. 2U 8 x 2.5" (Drive Bay #1) - SAS/SATA Data Cable Guide (with no SAS Expander)
Cables for On-board Cables for Mezzanine 12 Cables for Mezzanine 6 Cables for 12 Gb SAS Cables for 6 Gb SAS
System
Drive Support Multi-port SATA Ports to Gb SAS ROC Module to Gb SAS RAID module to RAID PCIe* add-in card RAID PCIe* add-in card
Configuration
Drive Bay #1 Drive Bay #1 Drive Bay #1 to Drive Bay #1 to Drive Bay #1
Cable Connections: Cable Connections: Cable Connections: From Riser #1: From Riser #1:
SATA Cntlr -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 Cable Connections: Cable Connections:
730mm HD --- HD 730 mm HD --- HD 730 mm HD --- MS
SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
sSATA Cntrl -> BP 4-7 SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7
730 mm HD --- HD 730 mm HD --- MS
730 mm HD --- HD 730 mm HD --- HD 730 mm HD --- MS
SAS PCIe -> BP 4-7 SAS PCIe -> BP 4-7
730 mm HD --- HD 730 mm HD --- MS
From data above, select From data above, select From data above, select
appropriate cable kits appropriate cable kits from appropriate cable kits from
Drive Bay #1 from list below: list below: list below:
From Riser #2 From Riser #2
SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
8 x 2.5” AXXCBL730HDHD AXXCBL730HDHD AXXCBL730HDMS 730 mm HD --- HD 730 mm HD --- MS
R2208… SAS PCIe -> BP 4-7 SAS PCIe -> BP 4-7
R2216… (2) 730mm Cables (2) 730mm Cables 730 mm HD --- HD 730 mm HD --- MS
R2224… included with all 2.5” L6 included with all 2.5” L6
Integrated systems Integrated systems From data above, select From data above, select
appropriate cable kits appropriate cable kits
from list below: from list below:
AXXCBL730HDHD AXXCBL730HDMS
39
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Table 8. 2U 8 x 2.5” (Drive Bay #2) – SAS / SATA Data Cable Guide (with no SAS Expander)
Cables for On-board Cables for Mezzanine 12 Cables for Mezzanine 6 Cables for 12 Gb SAS Cables for 6 Gb SAS
System
Drive Support Multi-port SATA Ports to Gb SAS ROC Module to Gb SAS ROC module to RAID PCIe* add-in card RAID PCIe* add-in card
Configuration
Drive Bay #2 Drive Bay #2 Drive Bay #2 to Drive Bay #2 to Drive Bay #2
Cable Connections: Cable Connections: Cable Connections: From Riser #1: From Riser #1:
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
SATA Cntlr -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 650 or 730mm HD -- HD 650 or 730mm HD -- MS
730mm HD -- HD 730mm HD -- HD 730mm HD -- MS SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
SAS Mezz -> BP 4-7 730 or 800mm HD -- HD 730 or 800mm HD -- MS
sSATA Cntrl -> BP 4-7 SAS Mezz -> BP 4-7 875mm HD -- MS
875mm HD -- HD 875mm HD -- HD From Riser #2: From Riser #2:
From data above, select
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
From data above, select From data above, select appropriate cable kits
Drive Bay 800 or 875mm HD -- HD 800 or 875mm HD -- MS
appropriate cable kits appropriate cable kits from from list below:
#2 SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
from list below: list below:
730 or 875mm HD -- HD 730 or 875mm HD -- MS
(no SAS AXXCBL730HDMS
Expander) 8 x 2.5” AXXCBL730HDHD AXXCBL730HDHD AXXCBL875HDMS
From data above, select From data above, select
(730mm Included in all (730mm Included in all
appropriate cable kits appropriate cable kits
2.5” L6) 2.5” L6)
R2216… from list below: from list below:
AXXCBL875HDHD AXXCBL875HDHD
R2224… (875mm Included in (875mm Included in
AXXCBL650HDHD AXXCBL650HDMS
R2224 L6) R2224 L6)
AXXCBL730HDHD AXXCBL730HDMS
(2) 730mm Included in all AXXCBL800HDMS
2.5” L6 AXXCBL875HDMS
AXXCBL800HDHD
AXXCBL875HDHD
(4) 875mm Included in
R2224 L6)
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
For R2224WTxxx System configurations with no SAS Expander, reference Tables 7, 8, and 9 for cable guidance for all three drive bay modules.
40
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Table 9. 2U 8 x 2.5” (Drive Bay #3) – SAS / SATA Data Cable Guide (with no SAS Expander)
Cables for On-board Cables for Mezzanine 12 Cables for Mezzanine 6 Cables for 12 Gb SAS Cables for 6 Gb SAS
System
Drive Support Multi-port SATA Ports to Gb SAS ROC Module to Gb SAS ROC module to RAID PCIe* add-in card RAID PCIe* add-in card
Configuration
Drive Bay #3 Drive Bay #3 Drive Bay #3 to Drive Bay #3 to Drive Bay #3
Cable Connections: Cable Connections: Cable Connections: From Riser #1: From Riser #1:
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
SATA Cntlr -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 730 or 875mm HD -- HD 730 or 875mm HD -- MS
800mm HD -- HD 730mm HD -- HD 730mm HD -- MS SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
SAS Mezz -> BP 4-7 800 or 950mm HD -- HD 800 or 950mm HD -- MS
sSATA Cntrl -> BP 4-7 SAS Mezz -> BP 4-7 730mm HD -- MS
730mm HD -- HD 730mm HD -- HD From Riser #2: From Riser #2:
From data above, select
SAS PCIe -> BP 0-3 ** SAS PCIe -> BP 0-3 **
From data above, select From data above, select appropriate cable kits
730 or 875mm HD -- HD 800 or 875mm HD -- MS
Drive Bay #3 appropriate cable kits appropriate cable kits from from list below:
SAS PCIe -> BP 4-7 ** SAS PCIe -> BP 4-7 **
from list below: list below:
(no SAS 650 or 800mm HD -- HD 650 or 800mm HD -- MS
AXXCBL730HDMS
Expander) AXXCBL730HDHD AXXCBL730HDHD
8 x 2.5” From data above, select From data above, select
(2) 730mm cables (2) 730mm cables Included
appropriate cable kits appropriate cable kits
R2224… Included in all 2.5” L6) in all 2.5” L6)
from list below: from list below:
AXXCBL800HDHD
AXXCBL650HDHD AXXCBL650HDMS
AXXCBL730HDHD AXXCBL730HDMS
(2) 730mm Included in all AXXCBL800HDMS
2.5” L6 AXXCBL875HDMS
AXXCBL800HDHD AXXCBL950HDMS
AXXCBL875HDHD
(4) 875mm Included in
R2224 L6
AXXCBL950HDHD
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the
card, a shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
41
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
4.2.5.2 2U 2.5” Front Mount Drive Configurations – SAS Data Cable Guide (with SAS Expander)
SAS drive configurations consisting of more than 8 drives may require the addition of a SAS Expander card. In the 2U 16x2.5” or 24x2.5” system
configurations, a SAS expander can be mounted in the area directly behind the drive bays. Intel provides two SAS expander options to support these
drive configurations:
Intel® RAID Expander RES2CV360 Required (sold separately): iPC – AXXCBLEXPHDMS - MS-HD 6Gb
Expander to 12 Gb Backplane Data Cable kit, SAS Data Cables from 6 Gb
SAS RAID PCIe/Mezz Card to expander. See Table 10.
42
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: The onboard SATA ports are not compatible with SAS Expander cards. The onboard SATA ports can only be cabled directly to a specified
backplane.
Table 10. 2U 2.5” Front Mount Drive Configurations with SAS Expander – SAS Data Cable Guide
Mezzanine 12Gb SAS 12Gb SAS RAID PCIe* Mezzanine 6 Gb SAS 6Gb SAS RAID PCIe* Mezzanine 6 Gb SAS 6Gb SAS RAID PCIe* add-
ROC Module to 12 Gb add-in card to 12 Gb SAS ROC Module to 12 Gb add-in card to 12 Gb SAS ROC Module to 6 Gb SAS in card to 6 Gb SAS
SAS Expander Expander SAS Expander Expander Expander Expander
12 Gb SAS Expander 12 Gb SAS Expander 12 Gb SAS Expander 12 Gb SAS Expander 6 Gb SAS Expander 6 Gb SAS Expander
RES3TV360 installed: RES3TV360 installed: RES3TV360 installed: RES3TV360 installed: RES2CV360 installed: RES2CV360 installed:
From Riser #1:
SAS Mezz -> Exp 0-3 (G) SAS PCIe -> Exp 0-3 (G) SAS Mezz -> Exp 0-3 (G) SAS Mezz -> Exp 0-3 (A) From Riser #1:
From Riser #1:
730mm HD -- HD 650mm HD -- HD 730mm HD -- MS 730mm MS -- MS SAS PCIe -> Exp 0-3 (G)
SAS PCIe -> Exp 0-3 (G)
SAS PCIe -> Exp 4-7 (H) 650mm HD --MS 650mm MS --MS
SAS Mezz -> Exp 4-7 (H) 650mm HD -- HD SAS Mezz -> Exp 4-7 (H) SAS Mezz -> Exp 4-7 (B) SAS PCIe -> Exp 4-7 (H)
SAS PCIe -> Exp 4-7 (H)
730mm HD -- HD 730mm HD -- MS 730mm MS -- MS 650mm MS --MS
650mm HD --MS
From Riser #2:
From data above, select From data above, select From data above, select
SAS PCIe -> Exp 0-3 (G) From Riser #2: From Riser #2:
appropriate cable kits appropriate cable kits appropriate cable kits
730mm HD -- HD SAS PCIe -> Exp 0-3 (G) SAS PCIe -> Exp 0-3 (G)
from list below: from list below: from list below:
SAS PCIe -> Exp 4-7 (H) 730mm HD --MS 730mm MS --MS
730mm HD -- HD SAS PCIe -> Exp 4-7 (H) SAS PCIe -> Exp 4-7 (H)
AXXCBL730HDHD AXXCBL730HDMS AXXCBL730MSMS
From data above, select 730mm HD -- MS 730mm MS -- MS
(2) 730mm cables
appropriate cable kits from From data above, select
Included in all 2.5” L6)
list below: appropriate cable kits From data above, select
from list below: appropriate cable kits from
AXXCBL650HDHD list below:
AXXCBL730HDHD AXXCBL650HDMS
(2) 730mm cables Included AXXCBL730HDMS AXXCBL650MSMS
in all 2.5” L6) AXXCBL730MSMS
12 Gb SAS Expander to 12 Gb SAS Expander to 12 Gb SAS Expander to 12 Gb SAS Expander to 6 Gb SAS Expander to 6 Gb SAS Expander to
drive bays drive bays drive bays drive bays drive bays drive bays
Use cables included in Use cables included in SAS Use cables included in Use cables included in Cable Kit Required: Cable Kit Required:
SAS Expander Kit Expander Kit SAS Expander Kit SAS Expander Kit iPC – AXXCBLEXPHDMS iPC – AXXCBLEXPHDMS
43
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Figure 9. – 12Gb Internal 36-Port Intel® RAID Expander Card RES3TV360 - Connector Identification Block Diagram
Figure 10. – 6Gb Internal 36-Port Intel® RAID Expander Card RES2CV360 - Connector Identification Block Diagram
44
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
MS = Straight SFF-8087 Mini SAS Connector (compatible with 6Gb/sec SAS controllers and expanders)
45
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Table 11. Storage Data Cable Kit Description and Order Information
Image Order Information Description
iPC – AXXCBL950HDHD
MM – 936122 950 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
UPC – 00735858286596
EAN – 5032037066495 Used in multiple systems as spare and/or accessory (1304, 2308, 2312)
MOQ – 1
iPC – AXXCBL875HDHD
MM – 936123
875 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
UPC – 00735858284769
Used in multiple systems as spare and/or accessory (1304, 1208 2208, 2312)
EAN – 5032037065054
MOQ – 1
iPC – AXXCBL800HDHD
MM – 937312 800 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
UPC – 00735858286015
EAN – 5032037066006 Used in multiple systems as spare and/or accessory (1203, 1208, 2308, 2312)
MOQ – 1
iPC – AXXCBL730HDHD
MM – 936178
730 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
UPC – 00735858284745
Used in multiple systems as spare and/or accessory (1208, 2208)
EAN – 5032037065030
MOQ – 1
iPC – AXXCBL650HDHD 650 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8643
MM – 937129
UPC – 00735858284752
EAN – 5032037065047 Used as accessory when installing 12G ROC module in 1208 for optimal cabling. (longer
MOQ – 1 cable may be used)
iPC – AXXCBL1UHRHD
Combo cable kit, contains 2 cables. One of each of the following:
MM – 937311
730mm (AXXCBL800HRHD),
UPC – 00735858287401
800mm right angle SFF8643 to straight SFF8643,
EAN – 5032037067140
Spare cables used in 1U WT systems to connect to onboard SATA ports.
MOQ – 1
46
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – AXXCBL950HDMS
950 mm long, cable kit (2 cables included) straight SFF8643to straight SFF8087
MM – 937131
UPC – 00735858286633
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 with
EAN – 5032037066532
HBA, 2308 and 2312 HBA/module)
MOQ – 1
iPC – AXXCBL875HDMS
875 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
MM – 937130
UPC – 00735858286626
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 and
EAN – 5032037066525
1208 with HBA, 2216,2224,2312 with HBA/module)
MOQ – 1
iPC – AXXCBL800HDMS
800 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
MM – 937309
UPC – 00735858286084
Required in WT 2U systems with 6G SAS ROC module or 6G SAS RAID cards. (1304 and
EAN – 5032037066075
1208 with module, 2308 and 2312 HBA/module)
MOQ – 1
iPC – AXXCBL730HDMS
730 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
MM – 927238
UPC – 00735858266970
Required in WT 2U systems with 6G SAS ROC module or 6G SAS HBA cards. (1208 with
EAN – 5032037053648
HBA, 2208 with HBA/module)
MOQ – 5
iPC – AXXCBL650HDMS
650 mm long, cable kit (2 cables included) straight SFF8643 to straight SFF8087
MM – 927237
UPC – 00735858266963
Used as accessory when installing 6Gb ROC module in 1208 for optimal cabling. (longer
EAN – 5032037053631
cable may be used)
MOQ – 5
47
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – AXXCBLEXPHDMS
6 Gb Expander to 12 Gb Backplane cable kit
MM – 937127
6Gb MS – to – 12Gb HD
UPC – 00735858284776
EAN – 5032037065061
(3) 165 mm, (1) 185 mm, (1) 245 mm, (1) 300 mm straight SFF8643 to straight SFF8087
MOQ – 1
iPC – AXXCBL650MSMS
650 mm long, cable kit (2 cables included) straight SFF8087 to straight SFF8087
MM – 918376
UPC – 00735858224444
Required in WT 2U systems with 6Gb SAS ROC module or 6Gb SAS HBA cards. (1208
EAN – 5032037019910
with HBA, 2208 with HBA/module) and 6 Gb Expander card
MOQ – 5
iPC – AXXCBL730MSMS
730 mm long, cable kit (2 cables included) straight SFF8087 to straight SFF8087
MM – 921049
UPC – 00735858245340
Required in WT 2U systems with 6Gb SAS ROC module or 6Gb SAS HBA cards. (1208
EAN – 5032037039864
with HBA, 2208 with HBA/module) and 6 Gb Expander card
MOQ – 1
iPC – AXXCBL880SATA
MM – 922988
Spare SATA ODD Data cable for rack chassis family – 880mm long
UPC – 00735858250290
Included with ODD accessories
EAN – 5032037044806
MOQ – 10
48
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.1 1U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit
A1U44X25NVMEDK
• The 8x2.5” combo backplane kit is capable of supporting a combination of both SAS devices and up to four PCIe* SFF (Small Form Factor) (NVMe)
SSD drives
• All eight drive connectors are capable of supporting a SAS device, but only four include SFF8639 connectors that can support PCIe* SFF (NVMe)
SSDs
• This kit is only supported in dual processor configurations
iPC – A1U44X25NVMEDK
1U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane Kit
Kit IncludesL
(1) Combo Hot Swap Backplane PCBA
MM# – 936251 (4) SAS / SATA Hot Swap Drive Carriers (Green Latch)
UPC – 00735858288873 (4) PCIe* SFF SSD (NVMe) Hot Swap Drive Carriers (Blue Latch)
EAN – 5032037068154 (2) Dual PCIe* Port Cables 1U Accessory Kit
MOQ – 1 (1) PCIe x16 Add-in card
(1) Installation Guide
See the Intel® Server System R1000WT Technical Product Specification for additional information.
49
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
PCIe* PCIe*
Port Port
PCIe* PCIe*
0/1 0/1
Port Port
2/3 2/3
SAS Ports PCIe* PCIe* SFF SAS PCIe* SFF PCIe* SATA PCIe* SFF PCIe* SFF SATA PCIe* SFF PCIe* SFF
0-3 SFF Device 0 Ports 4-7 Device 2 SFF Ports Device 1 Device 0 Ports Device 2 Device 3
Device 1 Device 3 0-3 4-7
50
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Table 12. 1U 8x2.5" Combo Backplane SAS/SATA Cable Guide
Cables for On-board Cables for Mezzanine Cables for Mezzanine Cables for 12 Gb SAS Cables for 6 Gb SAS
System Configuration Drive Support Multi-port SATA 12 Gb SAS ROC 6 Gb SAS RAID RAID PCIe* add-in card RAID PCIe* add-in card
Ports to Backplane Module to Backplane module to Backplane to Backplane to Backplane
730 mm HR --- HD 650 mm HD --- HD 650 mm HD --- MS From Riser #1 From Riser #1
Connect cable to: Connect cable to: Connect cable to:
SATA -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 730 mm HD --- HD 730 mm HD --- MS
A1U44X25NVMEDK Connect cable to: Connect cable to:
Accessory kit and / or and/or and/or SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
Option
800 mm HR --- HD 800 mm HD --- HD 800 mm HD --- MS and/or and/or
8 x 2.5” Combo Connect cable to: Connect cable to: Connect cable to:
R1208WTxxx SAS / SATA + PCIe* sSATA -> BP 4-7 SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7 875 mm HD --- HD 875 mm HD --- MS
R1208WTTGSR SSD SFF (NVMe) Connect cable to: Connect cable to:
12 Gb SAS capable Cables Included with Cable Kits Required: Cable Kits Required: SAS PCIe -> BP 4-7 SAS PCIe -> BP 4-7
R1208WT2GSR
system SKUs. AXXCBL650HDHD AXXCBL650HDMS
and / or and / or Cable Kits Required: Cable Kits Required:
with PCIe* cables Cable kit required for AXXCBL800HDHD AXXCBL800HDMS AXXCBL730HDHD AXXCBL730HDMS
included in building block and / or and / or
A1U44X25NVMEDK accessory kit. For integration: Use PCIe* cables Use PCIe* cables AXXCBL875HDHD AXXCBL875HDMS
SAS/SATA support AXXCBL1UHRHD included with Combo included with Combo
see the following backplane kit for PCIe* backplane kit for PCIe* Use PCIe* cables Use PCIe* cables
options Use PCIe* cables SSD / NVMe drive SSD / NVMe drive included with Combo included with Combo
included with Combo support support backplane kit for PCIe* backplane kit for PCIe*
backplane kit for PCIe* SSD / NVMe drive SSD / NVMe drive
SSD / NVMe drive support support
support
51
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.2 2U 8x2.5” Combo PCIe* SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit
A2U44X25NVMEDK
• The 8x2.5” combo backplane kit is capable of supporting a combination of both SAS devices and up to four PCIe* SFF (Small Form Factor) (NVMe)
SSD drives
• All eight drive connectors are capable of supporting a SAS device, but only four include SFF8639 connectors that can support PCIe* SFF (NVMe)
SSDs
• The PCIe* x16 interface add-in card MUST be installed in a x16 riser card (included), and is only supported in the Riser #2 slot of the server board.
• This kit is only supported in dual processor configurations
• The 2U system is limited to supporting only one combo backplane kit in addition to one or two other backplane options
• The combo backplane module can only be supported in the first (left) drive bay when no other backplane module is installed
• Due to thermal and power limits associated with 16 x 2.5” and 24 x 2.5” front drive configurations, the combo backplane module can only be
supported in the second (middle) drive bay
52
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
See the Intel® Server System R2000WT Technical Product Specification for additional information.
53
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Figure 13. Combo Backplane Module Placement – 8 x 2.5” front drive configurations
Cables for On-board Cables for Mezzanine Cables for Mezzanine Cables for 12 Gb SAS Cables for 6 Gb SAS
System Drive Bay #1
Multi-port SATA Ports 12 Gb SAS ROC 6 Gb SAS RAID RAID PCIe* add-in card RAID PCIe* add-in card
Configuration
to Backplane Module to Backplane module to Backplane to Backplane to Backplane
730 mm HD --- HD 730 mm HD --- HD 730 mm HD --- MS From Riser #1 From Riser #1
Connect cable to: Connect cable to: Connect cable to:
SATA -> BP 0-3 SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 730 mm HD --- HD 730 mm HD --- MS
Included w/system Included w/system Connect cable to: Connect cable to:
SKUs SKUs and/or SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
and / or and/or
8 x 2.5” Combo 730 mm HD --- MS and/or and/or
R2208WT… SAS / SATA + PCIe* 730 mm HD --- HD 730 mm HD --- HD Connect cable to:
SSD SFF (NVMe) Connect cable to: Connect cable to: SAS Mezz -> BP 4-7 730 mm HD --- HD 730 mm HD --- MS
iPC sSATA -> BP 4-7 SAS Mezz -> BP 4-7 Connect cable to: Connect cable to:
A2U44X25NVMEDK Included w/system Included w/system Cable Kits Required: SAS PCIe -> BP 4-7 SAS PCIe -> BP 4-7
SKUs SKUs (1 or 2)
PCIe* cables included AXXCBL730HDMS Cable Kits Required: Cable Kits Required:
in accessory kit. For Cable kit required for Cable kit required for (1 or 2) (1 or 2)
Drive Bay #1 SAS/SATA support building block building block Use PCIe* cables AXXCBL730HDHD AXXCBL730HDMS
populated see the following integration: integration: included with Combo
options (2) AXXCBL730HDHD (2) AXXCBL730HDHD backplane kit for PCIe* Use PCIe* cables included Use PCIe* cables
SSD SFF / NVMe drive with Combo backplane kit included with Combo
Use PCIe* cables Use PCIe* cables support for PCIe* SSD SFF / NVMe backplane kit for PCIe*
included with Combo included with Combo drive support SSD SFF / NVMe drive
backplane kit for PCIe* backplane kit for PCIe* support
SSD SFF / NVMe drive SSD SFF / NVMe drive
support support
54
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.2.2 2U 16x2.5” / 24x2.5” –– Intel® Accessory Kit A2U44X25NVMEDK SAS / SATA Cable Guide
Figure 14. Combo Backplane Module Placement - 16 x 2.5” and 24 x 2.5” front drive configurations
Cables for Mezzanine Cables for Mezzanine 6 Cables for 12 Gb SAS Cables for 6 Gb SAS
System Cables for Drive Drive Bay #2 Backplane
12 Gb SAS ROC Module Gb SAS RAID module to RAID PCIe* add-in card RAID PCIe* add-in card
Configuration Bay #1 Type
to Drive Bay #2 Drive Bay #2 to Drive Bay #2 to Drive Bay #2
730mm HD --- HD 730mm HD --- MS From Riser #1 From Riser #1
See section 5.2.1 Connect cable to: Connect cable to:
SAS Mezz -> BP 0-3 SAS Mezz -> BP 0-3 730 mm HD --- HD 730 mm HD --- MS
Connect cable to: Connect cable to:
and/or and/or SAS PCIe -> BP 0-3 SAS PCIe -> BP 0-3
8 x 2.5” Combo
SAS / SATA + PCIe* SSD 800mm HD --- HD 800mm HD --- MS and/or and/or
SFF (NVMe) Connect cable to: Connect cable to:
iPC SAS Mezz -> BP 4-7 SAS Mezz -> BP 4-7 800 mm HD --- HD 800 mm HD --- MS
R2216WT… A2U44X25NVMEDK Connect cable to: Connect cable to:
One or both cable kits for One or both cable kits SAS PCIe -> BP 4-7 SAS PCIe -> BP 4-7
R2224WT…
PCIe* cables included in building block for building block
accessory kit. integration: integration: One or both cable kits One or both cable kits for
(1) AXXCBL730HDHD (1) AXXCBL730HDMS for building block building block
For SAS/SATA support
(1) AXXCBL800HDHD (1) AXXCBL800HDMS integration: integration:
see the following
(1) AXXCBL730HDHD (1) AXXCBL730HDMS
options
Use PCIe* cables Use PCIe* cables (1) AXXCBL800HDHD (1) AXXCBL800HDMS
included with Combo included with Combo
backplane kit for PCIe* backplane kit for PCIe* Use PCIe* cables Use PCIe* cables
SSD / NVMe drive SSD / NVMe drive included with Combo included with Combo
support support backplane kit for PCIe* backplane kit for PCIe*
SSD SFF / NVMe drive SSD SFF / NVMe drive
support support
55
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.3 2U 8x2.5” Combo PCIe x8 SFF (NVMe) SSD / SAS Backplane – Intel® Accessory Kit
A2U44X25NVMEDK2
• This 8x2.5” combo backplane kit is capable of supporting a combination of both SAS devices and up to four PCIe* SFF (Small Form Factor) (NVMe)
SSD drives and eight PCIe* SFF (Small Form Factor) (NVMe) SSD drives possible with the of A2U44X25NVMEDK2 kits.
• All eight drive connectors are capable of supporting a SAS device, but only four include SFF8639 connectors that can support PCIe* SFF (NVMe)
SSDs
• The Intel® PCI Express 8-Lane add in card included in this kit has 4-Port Fan-Out Switch which is compatible with standard PCIe SIG x8 or x16 PCIe
slots
• The Kit comes with both full height and low profile mounting brackets
• To support 8 NVMe drives there would be 4 NVMe in the first bay and 4 NVMe in the 2nd bay
• This kit is only supported in dual processor configurations
• The combo backplane module can be supported in the first (left) drive bay when no other backplane module is installed
56
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: Cable connections identified in the following cable routing diagrams can be applied to any combo backplane assembly installed. However, cable
routing may differ depending on which riser card the x8 PCIe* Retimer card is installed.
Combo Backplane Cable Routing – PCIe* SFF (NVMe) + SAS Combo Backplane Cable Routing - PCIe* SFF (NVMe) + SATA
57
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
The 2U system is limited to supporting up to two combo backplane assemblies in addition to one or two other backplane options.
• The combo backplane assembly can only be supported in the first (left) drive bay when no other backplane module is installed.
• In 16 drive configurations, the combo backplane assemblies are supported in the first two drive bays of the 2U chassis.
• In a 24 drive configuration, the combo backplane assemblies are only supported in the first two drive bays of the chassis.
58
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
• The front side of the backplane includes eight hot swap drive interface connectors. All eight connectors can support SAS (or SATA) drives, but only
the first four are capable of supporting PCIe* SFF (NVMe) SSDs.
• The x8 PCIe* Switch Add-in Card can be supported in the following PCIe Riser Card locations:
• PCIe Riser Card #1 – Top and Bottom PCIe add-in card slots only
• PCIe Riser Card #2 – Any available PCIe add-in card slot
• PCIe Riser Card #3** (If installed) – Not supported
Note: With the exception of the top PCIe add-in slot on Riser #1, all PCIe add-in card slots identified above require that the system have 2 processors
installed
5.4 2U Rear Mount Hot Swap Drive Bay Accessory Kit – iPC A2UREARHSDK
The 2U product family provides the option to support two 2.5” 6 Gb/sec hot swap SSDs installed to a modular drive bay mounted in the back of the
system.
59
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
60
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.5 2U 8x3.5” Front Mount Hot Swap Backplane Assembly - iPC A2U8X35S3HSDK
8x3.5” SAS/SATA Front Mount Hot-Swap Drive Bay Module option for 2U Building Block Chassis iPC – R2000WTxxx.
See the Intel® Server System R2000WT product family System Integration and Service Guide for complete kit installation instructions.
61
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Figure 15. R2208WT and R2216WT based system with Front I/O Module Bay Assembly
62
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
R2208WT (8x2.5” – 1 drive bay) and R2216WT (16x2.5” – 2 drive bays) system configurations utilize the same front I/O module bay assembly containing
the System Control Panel and Front I/O Panel (as shown in Figure 9). When upgrading a R2208WT based system to an R2216WT based system, all that
is needed is the removal of the Bay #2 face plate to insert the new drive bay, and adding the required data cables. No other chassis changes or additions
are required.
Kit Includes:
MM# – 935066 (1) Drive Bay Assembly Module 2U 2.5” Drive
Upgrade Kit
UPC – 00735858288767 (1) 8x2.5” hot swap backplane
2U Building Block
EAN – 5032037068048 (8) 2.5” drive carriers + drive blanks
Accessory Kit
MOQ – 1 (1) 75mm I2C Backplane-to-Backplane jumper cable
(1 set) mounting hardware
iPC – A2U8X25S3DPDK
Kit Includes:
MM# – 935067 (1) Drive Bay Assembly Module
2U 2.5” Drive
UPC – 00735858288774 (1) 8x2.5” hot swap backplane Upgrade Kit
EAN – 5032037068055 (8) 2.5” drive carriers + drive blanks 2U Building Block
(1) 75mm I2C Backplane-to-Backplane jumper cable Accessory Kit
MOQ – 1
(1 set) mounting hardware
63
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
For a 2U building block configuration consisting of 24x2.5” drives (3 drive bays – See Figure 10) or when upgrading a R2208WT or R2216WT system to
a 24 drive R2224WT system, the 2U storage front panel option of Intel Accessory Kit A2UHANDLKIT must be installed.
iPC – A2UHANDLKIT
1U / 2U Rack Handle Kit
(1) Set of 2U storage rack handles with control panel and USB
MM# – 936038
support 2U – 24 2.5” Drive
UPC – 00735858288866
(R2312WT & R2224WT) Upgrade Kit
EAN – 5032037068147
1U / 2U Spares Kit
MOQ – 1
(1) Set of 2U non –storage rack handles
(R2208WT & R2216WT)
See the Intel Server System R2000WT Product Family System Integration and Service Guide for complete system integration and upgrade instructions.
64
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
The face of the bezel assembly includes snap-in identification badge options and a wave feature option to allow for customization.
65
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
The face of the bezel assembly includes snap-in identification badge options and a wave feature option to allow for customization.
66
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
All PCIe* bus lanes to the riser slots are routed from the processors. Riser slot 1 has a total of 24 PCIe* 3.0 bus lanes routed from both processors; 16
lanes from processor #1 and 8 lanes from processor #2. Riser slot 2 has a total of 24 PCIe* 3.0 bus lanes routed from CPU 2. For riser slot 3, all PCIe*
bus lanes are routed from CPU 2; 8 PCIe* bus lanes are PCIe* 3.0 compatible and 4 PCIe* lanes are PCIe* 2.0 compatible. See the product Technical
Product Specification (TPS) for additional information.
Riser slots 1 and 2 are capable of supporting up to 100W maximum power each. Available power to each add-in card slot on a given riser card is defined
by the PCIe* specification. The server board provides two Auxiliary 12V power connectors that when cabled (iPC AXXGPGPUCABLE), can provide
additional power to high power PCIe* add-in cards.
Each riser card assembly has support for a single full height, ½ length PCIe* add-in card. However, riser card #2 may be limited to ½ length, ½ height
add-in cards if either of the two mini-SAS HD connectors on the server board are used.
Note: Add-in cards that exceed the PCI specification for ½ length PCI add-in cards (167.65mm or 6.6in) may interfere with other installed devices on
the server board.
67
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Each 3-slot riser card assembly has support for up to two full height full length add-in cards (top and middle slots) and one full height ½ length add-in
card (bottom slot).
Each 2-slot riser card assembly has support for one full height full length add-in card (top slot) and one full height ½ length add-in card (bottom slot).
Note: The A2UL16RISER2 accessory kit includes a 12V Auxiliary Power cable which can be used to provide additional 12V power for high power PCIe*
add-in cards that require it.
Note: The x16 2-slot riser card is included in Intel Accessory Kit A2U44X25NVMEDK. Systems configured with the A2U44X25NVMEDK accessory kit
cannot support dual Intel® Xeon Phi™ coprocessor cards or dual non-Intel GPGPU cards.
68
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Slot # Description
MM# – 934883 Slot-1 PCIe* x4 elec, x8 mechanical (PCIe* 2.0 support
• 2U Building Block Accessory Kit
UPC – 00735858283311 (Top) only)
• 2U Spare FRU
EAN – 5032037064378 Slot-2 PCIe* x8 elec, x8 mechanical
(Bottom)
MOQ – 1
Kit includes:
(1) Riser card PCBA
Riser Slot #3 is provided to support up to two additional PCIe* add-in card slots for 2U server configurations. The available riser card option is designed
to support low profile add-in cards only.
69
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code Order Information Product Description Product Type
Intel® I/O Modules AXX1P40FRTIOM & AXX2P40FRTIOM
iPC – AXX1P40FRTIOM Intel® Single and Dual-Port 40G QSFP+ Ethernet I/O Modules based on
XL710-QDA1 and XL710-QDA2 10 Gigabit Ethernet Controllers
MM# – 933742
UPC – 00735858282291 On the dual port module, the 4x10GbE SFP+ break out is supported on
EAN – 5032037063623 Port 0 only
MOQ – 1 Available Optics Accessories:
• Intel® Ethernet QSFP+ SR4 Optics, E40GQSFPSR
• Intel® Ethernet 40G DCO Optics, E40GDCOQSFP
70
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code Order Information Product Description Product Type
71
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code Order Information Product Description Product Type
Additional information for Intel RAID products can be found at the following Intel web sites:
https://www.intel.com/content/www/us/en/products/servers/raid/raid-controllers.html?page=2
https://www.intel.com/content/www/us/en/servers/raid/tri-mode-raid-controller-brief.html
https://www.intel.com/content/dam/www/public/us/en/documents/product-briefs/tri-mode-raid-controller-brief.pdf
72
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
5.10.1 Intel® Integrated RAID Module RMS3 Product Family – SAS 3.0 (12 Gb/s)
Each riser card assembly has support for a single full height, ½ length PCIe* add-in card. However, riser card #2 may be limited to ½ length, ½ height
add-in cards if either of the two mini-SAS HD connectors on the server board are used or if a SATADOM storage device is installed into either of the
single port SATA connectors.
Note: Add-in cards that exceed the PCI specification for ½ length PCI add-in cards (167.65mm or 6.6in) may interfere with other installed devices on
the server board.
73
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
74
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
75
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
76
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – RS3GC008
Intel® RAID Controller RS3GC008
Low Profile, half length, (MD2 Compliant) PCIe* add-in card
MM# – 928220
Entry Level SAS Card
UPC – 00735858267175 8 external SAS / SATA ports • 1U / 2U Accessory Kit
EAN – 5032037053839 LSI* SAS3008 IOC
MOQ – 5 RAID Levels – JBOD (SAS Connectivity)
77
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
MM# – 937318
The AXXRMFBU4 kit is used with the 12 Gb/s Intel® RAID
UPC – 00735858273787 Controller PCIe* Add-in Cards • 1U / 2U Accessory Kit
EAN – 5032037058544
MOQ – 5 Compatible with:
Intel® RAID Controller RS3DC080
Intel® RAID Controller RS3DC040
Intel® RAID Controller RS3SC008
Intel® RAID Controller RS3MC044
78
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – AXXRPFKDE2
MM# – 915317 Intel® RAID Drive Encryption Management
UPC – 00735858221474
• 1U / 2U Accessory Kit
EAN - 5032037051705 Upgrade Key to enable Drive Encryption Management for Intel®’s RAID
MOQ – 5 RS25 and RS3 (based on LSI 3108) families of ROC products.
iPC – AXXRPFKSNSH2
MM# – 915318 Intel® RAID Rapid RecoverySnapshot
UPC – 00735858221481
• 1U / 2U Accessory Kit
EAN - 5032037051712 Upgrade Key to enable Rapid Recovery Snapshot for Intel®’s RAID RS25
MOQ – 5 and RS3 (based on LSI 3108) families of ROC products.
79
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
80
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
MM# – 947923 • Compatible with standard PCIe * SIG x8 or x16 PCIe slots.
UPC – 00735858315548 • Comes with full height and low profile mounting brackets. • 2U Accessory Kit
EAN – 5032037086547 • Mini-SAS HD cables included for cabling to NVMe drives /
MOQ – 1 backplanes
81
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – AXX1100PCRPS
MM# – 936183
UPC – 00735858287920 1100W AC CRPS 80+ Platinum efficiency power supply module • 2U Building Block Option
EAN – 5032037067478 • 2U Accessory Kit
MOQ - 1 Power cord sold separately • 2U Spare FRU
iPC – FXX750PCRPS
MM# – 915604
750W AC CRPS 80+ Platinum efficiency power supply module • 1U / 2U Building Block Option
UPC – 00735858234979
• 1U / 2U Accessory Kit
EAN – 5032037030601
Power cord sold separately • 1U / 2U Spare FRU
MOQ - 1
iPC – AXX750DCCRPS
750W -48v DC (Direct current) CRPS 80+ Gold efficiency power supply
module
MM# – 927253
• 1U / 2U Building Block Option
UPC –00735858260862 Kit Includes:
• 1U / 2U Accessory Kit
EAN –5032037051354 (1) power supply
• 1U / 2U Spare FRU
MOQ - 1 (1) O-ring terminal adapter.
Power cable sold separately
iPC – AXXDCCRPSCBL
MM – 922062
UPC – 00735858247993 4000mm (13ft) DC power cable. Connects directly to power supply • 1U / 2U Accessory Kit
EAN – 5032037042871 instead of O-ring terminals adapter • 1U /2U Spare FRU
MOQ – 1
iPC – FPWRCABLENA
MM# – 879287
UPC – 00735858181129 • 1U / 2U Accessory Kit
1500mm (59in) North American Power Cord
EAN – 5032037015738 • 1U / 2U Spare FRU
MOQ – 1
82
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
83
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code Order Information Product Description Product Type
84
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Intel Product Code Order Information Product Description Product Type
2U+ Premium quality rails with CMA support.
• Travel distance 800mm
MM# –939209 • Bracket adjustment from 594.8mm to 813mm
iPC – AXXFULLRAIL UPC –00735858291989 • Tool-less installation
2U Accessory Kit
EAN –5032037070546 • Supports up to 45Kg
MOQ – 1 • Full extension from rack
• Kit includes: Rails, screws, installation manual
• For Cable Management arm – order iPC AXXCMA2
MM# – 939211 Cable management arm
iPC – AXXCMA2 UPC –00735858292009
Compatible with AXXFULLRAIL only 2U Accessory Kit
EAN –5032037070560
MOQ – 1
5.13.4 Intel® Xeon Phi™ Coprocessor Card and Non-Intel GPGPU Support
Intel® Xeon Phi™ Coprocessor cards and non-Intel GPGPU cards are supported in the following 2U system configurations only: R2208WT, R2308WT,
and R2216WT.
Because of mechanical and thermal limits, the 1U product family and the R2312WT… and R2224WT… system configurations do NOT have support for
Intel® Xeon Phi™ coprocessor cards or non-Intel GPGPU cards.
Figure 18. Intel® Xeon Phi ™ Coprocessor Cards With Active and Passive Cooling
• Supported 2U systems configured with the standard (default) air duct, can only support high power add-in cards (>75W) with active (with fan) heat
sinks.
85
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
• In supported 2U system, high power add-in cards (>75W) with passive (no fan) heat sinks can only be supported in systems configured with a high
air flow air duct available in Intel Accessory Kit – iPC AWTCOPRODUCT.
Note: Intel® Server System R2208WTTYC1R is a special system SKU that includes the necessary components to support passive high power
(>75W) add-in cards like the Intel® Xeon Phi™ coprocessor card, Intel® Visual Compute Accelerator or non-Intel GPGPU cards.
See the Intel® Server System R2000WT product family Technical Product Specification for more information.
86
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: Systems configured with any type of Intel® Xeon Phi™ card and/or non-
Intel GPGPU card must have the shipping bracket installed before the
system is exposed to any level of shock or vibration or is shipped to the end
user location. Failure to install the shipping bracket has the potential to
cause serious damage to various components within the system.
Each Intel® Xeon Phi™ coprocessor card and non-Intel GPGPU card must be installed into the top x16 slot of a 2-Slot PCIe* Riser card. With a 2-slot
riser card installed, the embedded fan speed control will operate system fans at a higher speed. 3-slot riser cards (as shipped in the standard
platform configuration) cannot be used due to air flow and thermal limitations.
iPC – A2UL16RISER2 Required 2U accessory kit when installing an Intel® Xeon Phi™
coprocessor or other Non-Intel GPGPU card
MM# – 934886
Slot # Description • 2U Building Block Accessory
UPC – 00735858288668
Slot-1 (Top) PCIe* x16 elec, x16 mechanical Kit
EAN – 5032037067942
Slot-2 (Bottom) PCIe* x8 elec, x8 mechanical • 2U Spare FRU
MOQ – 1
Kit includes:
(1) Riser card PCBA
(1) 12V-AUX Power Cable
87
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
88
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
This Kit is NOT compatible with R2224 and R2312 based systems.
See the Intel® Local Control Panel Technical Product Specification for
more information
89
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
MM# – 935065
iPC - AXXSSDODDKIT Kit includes:
UPC – 00735858288750
(1) – Metal SSD mounting tray accomodates one 2.5” SATA SSD
EAN – 5032037068031 1U Accessory Kit
(1) – 800mm SATA data cable
MOQ – 1
(1) – SSD peripheral power cable
iPC - AXXRJ45DB93 This kit provides serial port cables for use with systems that include a
back panel cut out to support a DB9 Serial ‘B’ port as routed from the
server board and for systems that include an external RJ45 Serial ‘A’
MM# – 920430 port that need to convert the connector to a DB9 style connector.
UPC – 00735858242820
1U / 2U Accessory Kit
EAN – 5032037037525 Kit includes:
MOQ – 1 (1) - 1040mm Internal Serial ‘B’ port cable – Onboard DH10 header-
to- External Mount DB9 – for 2U systems
(1) - 520mm Internal Serial ‘B’ port cable – Onboard DH10 header-
to- External mount DB9 – for 2U systems
(1) – 100mm DCD RJ45 to DB9 Dongle
(1) – 100mm DSR RJ45 to DB9 Dongle
MM# – 911660 Installation of this activation key on to the server board enables
UPC – 00735858219297 support for the following advanced server management features:
1U / 2U Accessory Kit
EAN – 5032037014946 Integrated KVM
MOQ – 1 Media Redirection
See the Intel Remote Management Module 4 and Integrated Web
Console Users Guide for more information.
90
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC - AXXTPME5
A TPM is a hardware-based security device that addresses the
growing concern on boot process integrity and offers better data
MM# – 919737 protection. TPM protects the system start-up process by ensuring it is
UPC – 00735858240352 tamper-free before releasing system control to the operating system.
1U / 2U Accessory Kit
EAN – 5032037035088 A TPM device provides secured storage to store data, such as security
keys and passwords. In addition, a TPM device has encryption and
MOQ – 1
hash functions.
91
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
92
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
MM# – 937543
iPC – FXXFPANEL2 Front Panel board spare for use on 1U/2U rack systems (R1000,
UPC – 00735858288712 R2000 except R2224 and R2312) Rack chassis and P4000 Pedestal
EAN – 5032037067997 Chassis. Different from FXXFPANEL by 0.6mm offset of reset and 1U / 2U Spare FRU
power buttons.
MOQ – 1
iPC – FXXCA84X106HS
MM# – 918318
UPC – 00735858236676
1U Heat Sink FXXCA84X106HS (Cu/Al 84mmx106mm) 1U / 2U Spare FRU
EAN - 5032037031448
MOQ – 2
iPC - FR1UFAN10PW
MM# – 935064
Three spare fans for 1U R1000WT system. 40x56mm dual rotor with
UPC – 00735858283342
10p connector.
EAN – 5032037064408 1U Spare FRU
MOQ – 1
Includes 3 fans in the bracket, with grommets preinstalled.
iPC - FR2UFAN60HSW
MM# – 934990
Two spare fans for 2U R2000WT system. 60x38mm, with hot swap
UPC – 00735858283359
connector.
EAN – 5032037064415 2U Spare FRU
MOQ – 1
Includes 2 fans with finger guards and housing.
93
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – FR1304S3HSBP2
MM# – 947357
UPC – 00735858309264 Hot swap backplane board spare for 1U 4x3.5” chassis
1U Spare FRU
EAN – 5032037081856 (R1304 family). RoHs compliance.
MOQ – 1
iPC – F1U8X25S3HSBP
MM# – 934888 Hot swap backplane board spare for 1U 8x2.5" chassis (R1208
UPC – 00735858288798 family).
1U Spare FRU
EAN – 5032037068079
MOQ – 1
iPC – FXX8X25S3HSBP
MM# – 934890 Single port hot swap backplane board spare for 2U 8x2.5" cage
UPC – 00735858288804 (R2200 and P4000 families).
2U Spare FRU
EAN – 5032037068086
MOQ – 1 Includes one backplane board.
iPC – F2U8X35S3HSBP
MM# – 934892 Hot swap backplane board spare for 2U 8x3.5" chassis (R2308
UPC – 00735858288811 family).
2U Spare FRU
EAN – 5032037068093
MOQ – 1 Includes one backplane board.
iPC – F2U12X35S3HSBP
MM# – 934893 Hot swap backplane board spare for 2U 12x3.5" chassis (R2312
UPC – 00735858288828 family).
2U Spare FRU
EAN – 5032037068109
MOQ – 1 Includes one backplane board.
94
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
iPC – A2UHANDLKIT
(1) Set of 2U storage rack handles with control panel and USB
MM# – 936038
support 2U – 24 2.5” Drive Upgrade
UPC – 00735858288866
(R2312WT & R2224WT) Kit
EAN – 5032037068147
1U / 2U Spares Kit
MOQ – 1
(1) Set of 2U non –storage rack handles
(R2208WT & R2216WT)
iPC – FXX35HSCAR
MM# – 936192
UPC – 00735858289412 Spare 3.5” hot swap drive carriers.
1U / 2U Spare FRU
EAN – 5032037068390 Includes mounting screws for mounting 2.5” SSDs.
MOQ – 8
95
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Offer fast transcoding for video into multiple formats and bit rates reducing the amount of time needed to process the video inputs
Reduce the amount of storage needed for those multiple formats through higher compression processing
Allow for real time transcoding into multiple formats from the stored format, reducing the need to store all possible media formats
Reduces the amount of network bandwidth needed (lower bit rates) at better video quality by compressing the video prior to transmission
The Intel® Visual Compute Accelerator is uniquely capable of supporting the different media processing solutions as it contains three Intel Xeon
processor E3 v4 with Intel Iris Pro Graphics P6300; placing these three processors on a Gen3 x16 PCIe card provides high throughput and low latency
when moving data to and from the card.
iPC – VCA1283LVV
Full-length, full-height, doble width Gen3 PCIe x16
4 Cores Supported
MM# – 942876 47W TDP
UPC – 00735858309493 Processor Numer E3-1283L v4
2U Accessory Kit
EAN – 5032037081986 Base freq 2.9 GHz, Max Turbo freq 3.8 GHz
MOQ – 1 Max Memory size 96GB (DDR3-1333/1600/1866)
Note: it requieres to purchase reparately the accesory spare
“AWTCOPRODUCT”
96
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
UPC – 00735858334532 Base freq 3.0 GHz, Max Turbo freq 3.7 GHz
Max Memory size 64GB (DDR4 ECC SODIMMs, 2 channels 2U Accessory Kit
EAN – 5032037099127
per CPU)
MOQ – 1
8 MB cache
Note: it requieres to purchase reparately the accesory spare
“AWTCOPRODUCT”
97
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Note: This accessory will only be offered from the Intel site with a qualifying Intel® Server System purchase.
Learn more at:
http://www.intelserveredge/mcafeeaccessory.
98
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
99
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
10 Extended Warranty
iPC – SVCEWDPSY Two year extended warranty for Intel® Server Systems or Intel® Server Knock Down Kits + Intel®
Server Boards that support two processors. Intel® RAID controller extended warranty is purchased
MM# – 911295 separately.
MOQ – 1
iPC - SVCEWDPBD
MM# – 911294 Two year extended warranty for Intel® Server Boards that support two processors.
MOQ – 1
iPC - SVCEWRAID Two year extended warranty for Intel® RAID controllers. Batteries are not included in the Extended
MM# – 911298 Warranty. RAID expanders are included as part of the system SKU
MOQ – 1
100
Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
Glossary of Terms
A list of Acronyms and Terms used throughout this document:
Acronym or Term Definition Acronym or Term Definition
BIK Baseboard In Knock-Down-Kit – Integrated NVMe NVM Express – based on Non-Volatile Memory
System Host Controller Interface Specification
(NVMHCI)
CRPS Common Redundant Power Supply Optional Accessory Hardware that can be added to the system to
enhance the default feature set of the shipping
configuration
EAN International Article Number (Barcode) PCBA Printed Cricuit Board Assembly
EMI Electromagnetic Interference QSFP Quad Small Form factor Pluggable
ESRT2 Intel® Embedded Server RAID Technology 2 RAID Redundant Array of Independent Drives
FDR Infiniband Fourteen Data Rate Infiniband Required Option Hardware that must be added to the shipping
configuration for the system to operate
FRU Field Replaceable Unit RMFBU RAID Maintenance Free Backup Unit
GPGPU General Purpose computing on Graphics RMM4 Lite Intel® Remote Management Module 4 Lite
Processing Unit Activation key
iPC Intel Product Code ROC RAID on Chip
iPN Intel Product Number RSTe Intel® Rapid Stroage Technology
JBOD Just a bunch of drives SAS Serial Attached SCSI
L6 BIK Integrated system with no processors, SATA Serial ATA
memory, or storage devices installed
L8 BIK Integrated system including storage devices, SFF NVMe NVMe SSD in a 2.5” form factor
but no processors or memory
LCP Intel® Local Control Panel SFP Small Form factor Pluggable
KDK Knock-Down-Kit – (Chassis only product) SKU Stock Keeping Unit
KVM Keyboard / Video / Mouse SSD Solid State Drive
MM# Master Material order number UPC Universal Product Code ( Barcode)
MOQ Mimimum Order Quantity
101