THE SITE

Republic of the Philippines


OFFICE OF THE BUILDING OFFICIAL
3m 3
4.1
1

TO

18
=
JAI
L N "E

.6
7
SU
'1

3
AL
I 51

m
INC
M-A ROV N
P
G,
B.C 2 District City/ Municipality

m
17
3.

S
40
m

'2
30 LAND USE & ZONING

2"
8.

18

E=
.8
m NE

18
LI

5
65

16
TECHNICAL DESCRIPTION:

41
2. OF

.0
RO

.0
RO

.1

5
OF

m
9m
TO

m
N

LI
TIE POINT: PBM NO.20, CAD40, BAGO CADASTRE

N
LINE & GRADE

E
40
AB

'2
LINE BEARING DISTANCE
UA

2"
THE
NA

W
TO CORNER 1 S 56° 26' W 1660.49 M PROPOSED

=
N

1- 2 N 40° 22' W 41.98 M BUILDING

6.
41
ARCHITECTURAL

73
2- 3 N 51° 17' E 14.13 M

.9

m
8m
3- 4 S 40° 22' E 41.19 M

1
4- 1 S 48° 05' W 14.13 M

8.
05
4
VICINITY MAP SITE DEVELOPMENT PLAN

m
3m CIVIL/ STRUCTURAL

5.
SCALE: 1:300m
.1

30
14

m
=
" W
5
1 '0
48

5.
D ELECTRICAL

00
S
A

m
O
R
MECHANICAL

SANITARY

PLUMBING

ELECTRONICS

S-E VIEW
GEODETIC ENGINEER
P E R S P E C T I V E
Important: Certified by: Project Title: Approved by: Sheet No.
These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without CIVIL ENGINEER/ ARCHITECT
4-BEDROOM A1
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
3
8.30 m
2.55 m 5.45 m 0.60 m 2.70 m 5.60 m

0.60 m
W3 3.45 m 1.30 m 3.55 m

SLIDING WINDOW @ 3T&Bs 1.65 m 1.05 m W1


0.90 m

0.90 m
W2
1.80 m

W3
Tub

3.20 m

3.20 m
T&B

3.05 m
SLIDING WINDOW @ Kitchen MASTER'S

W1
D5
1.20 m BEDROOM
1.15 m

wc

1.20 m
W1 Sho.

6.80 m
SLIDING WINDOW, 6Sets D2

2.20 m

2.20 m
0.60 m
2.10 m

2.10 m

W1
W4

W1
2.10 m
D5 D3

1.40 m

1.40 m
D5 D3
1.30 m

1.30 m
T&B

W3
W3
PVC DOOR @ 3T&Bs
D5 T&B
1.80 m
D3

2.20 m

2.20 m
16.05 m
2.10 m

2.10 m

W1
2.10 m
D4 BEDROOM 2 D2

18.05 m
SLIDING DOOR @Dining Ref

0.80 m CS CS
KITCHEN

3.45 m
3.30 m

3.80 m
3.70 m

W2

D4
SINK
DINING

2.10 m
D3

BAR

6.60 m
6.50 m
RANGE

7.05 m
FLASH DOOR @ 3Bedrooms
0.80 m

2.35 m
2.00 m

TV
1.35 m
2.10 m
D2 LIVING
D1

0.80 m
5.25 m
5.05 m

PANEL DOOR, 1@MB, 1@Laundry


GARAGE
0.90 m W1

3.25 m
PORCH

0.45 m

2.00 m
2.10 m
D1 LS

0.75 m 2.70 m 0.75 m


4.00 m ENTRANCE PANEL DOOR ENTRANCE 4.20 m
1.74 m
4.40 m 5.25 m 4.50 m 1.75 m 4.70 m
10.95 m
DOORS & WINDOWS
REFLECTED CEILING PLAN SCALE: 1:100 M FLOOR PLAN
SCALE: 1:100 Mts. SCALE: 1:100 M

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without CIVIL ENGINEER/ ARCHITECT
4-BEDROOM A2
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
3
CEILING LINE

CEILING LINE DINING

3.80 m

3.80 m
W2 D2
LIVING KITCHEN
2.70 m

2.70 m
PORCH DINING
D5

MASTERS' BEDROOM
FLOOR LINE

LONGITUDINAL SECTION CROSS SECTION


SCALE: 1:100 M SCALE: 1:100 M

TRB

2ND FLOOR LINE

4.65 m
W3 W1 W3 D2 W2 W1

4.11 m
L D1

3.42 m
L

3.60 m
3.20 m
GE A
RA

2.70 m
2.70 m

3.10 m

2.90 m

2.89 m

2.45 m
G A W
2.10 m

2.10 m

2.10 m
2.10 m

E
1.50 m

1.50 m

1.20 m
0.90 m

I
F
FLOOR LINE FLR. LINE
CARPORT FLOOR LINE

0.45 m
CROWN OF THE ROAD LINE

LEFT SIDE ELEVATION FRONT ELEVATION

0.45 m
SCALE: 1:100 M SCALE: 1:100 M

TOP OF THE ROOF BEAM


4.65 m

4.65 m
W1 W3 W1 W1

4.10 m
D3

3.15 m
3.15 m

3.15 m
2.70 m

2.70 m
2.65 m

2.90 m
2.10 m

2.10 m

2.10 m

2.10 m

0.90 m
0.90 m

0.90 m

FLOOR LINE FLOOR LINE


CARPORT FLOOR LINE

0.90 m
RIGHT SIDE ELEVATION REAR SIDE ELEVATION
SCALE: 1:100 M SCALE: 1:100 M

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without CIVIL ENGINEER/ ARCHITECT
4-BEDROOM A3
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
3
2.65 m 8.30 m 3.17 m
5.05 m 3.25 m 0.15 m 4-12mm DSB REBARS
STIRRUPS: 9mm DSB, 2@0.05m, 3@0.10m,Rest@ 0.15m O.C.

PROPERTY LINE
C3F3 2.70 m C3F3 C3F3

PROPERTY LINE
WF WF

0.35 m
1.95 m
MASTER'S BEDROOM
Elev.= 0.60m

3.20 m
3.20 m

WF

WF
Slab Thickness= 0.10m

WF
Rebars:10mm DSB,
0.50m O.C, Bothways
1.25 m

5.30 m
3.60 m COLUMN COLUMN
C3F3
C3F3 WF REINFORCED CONCRETE ROOF BEAM DETAIL
SCALE: 1:30 M
3.50 m

2.10 m
2.30 m
2.20 m

9.05 m
WF

3.70 m
3.65 m

C3F3 0.10 m 0.10 m

0.20 m

0.20 m
WF
2.05 m 2.45 m
WF

1.50 m
1.45 m

T&B
12.75 m

E=0.40m
C3F3 C3F3 ST=0.07m
LB 4-12mm DSB
LINTEL BEAM VERTICAL BARS

3.75 m
6-12mm DSB 4"CHB Wall
2.40 m WF VERTICAL BARS Reinforced with TIES:9mm DSB, 4-12mm DSB
horizontal

WF
2.10 m

2.25 m

16.05 m
3@0.05m, VERTICAL BARS
WF
TIES:9mm DSB, 10mm DSB @ 5@0.10m,
4-12mm DSB 3@0.05m, every 3 Layers Rest@ 0.15m O.C.
WF

TIES:9mm DSB,
C3F3 VERTICAL BARS 5@0.10m, & 10mm DSB
C2F2 3@0.05m,
WF WF Rest@ 0.15m O.C. Vertical Bars
5@0.10m,
0.70 m

@ 0.60m O.C. 10mm DSB


TIES: 9mm DSB, Rest@ 0.15m O.C.
3@0.05m, CHB REBARS
C3F3 @ 0.60m O.C.
5@0.10m,
Bothways
C2F2 Rest@ 0.15m O.C.
3.80 m

0.60 m
WF
WF
2.80 m

0.47 m 0.20 m
FLOOR SLAB
GROUND LINE GROUND LINE

0.67 m
DINING &
C2iF2

7.00 m
C3F3 LIVING AREA
WF Elev.= 0.60m

0.15 m

1.20 m
Slab Thickness= 0.10m

1.00 m

1.00 m

1.00 m
Rebars: C2F2 WF
C3F3 2.30 m
2.05 m

Use 10mm DSB,


WF
WF

0.50m O.C, Bothways


WF

0.40 m

0.20 m

0.20 m

0.20 m

0.20 m
C3F3 C2F2
FIREWALL

WF
C3F3

WALL FOOTING
CARPORT
5.30 m

1.30 m

Elev.= 0.40m C2iF2 WF 0.75 m 0.65 m 0.65 m 0.65 m


Slab Thickness= 0.10m
Rebars: 0.25 m 0.15 m 0.15 m 0.15 m
3.25 m

WF

Use 10mm DSB,


0.50m O.C, Bothways C2F2 C2F2
PROPERTY LINE

4-12mmDSB 6-12mmDSB 6-12mmDSB


VERTICAL BARS 4-12mmDSB
VERTICAL BARS VERTICAL BARS
0.75 m

0.90 m
0.50 m

0.80 m
0.40 m
0.25 m

VERTICAL BARS

0.70 m
0.30 m
MATBARS: MATBARS: MATBARS:
5- 12mm DSB, MATBARS:
5- 12mm DSB, 5- 12mm DSB,
C1F1 C1F1 C1F1 Bothways 5- 12mm DSB,
PROPERTY LINE

Bothways Bothways
0.70 m 2.60 m 0.80 m Bothways

4.50 m 1.85 m 4.10 m 3.67 m


C1F1 C2F2 C2iF2 C3F3
(3 Sets) (6 Sets) (2 Sets) (14 Sets)

FOUNDATION PLAN COLUMN AND FOOTING DETAILS


SCALE: 1:100 M SCALE: 1:30 M

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without CIVIL ENGINEER
4-BEDROOM S1
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2
10.08 m

0.65 m 7- 10.12m, 2x4" ga.14 C- RAFTERS


@ ROOF #2 ROOF #1

ROOF #3
16-10.05m, 2x3" ga.16 C-PURLINS
@ROOF #2 ROOF #2

#2
10.05 m

10.05 m
ELEVATION

1.45 m
SCALE: 1:100 M

5- 8.32m, 2x4" ga.14 C- RAFTERS


@ ROOF #2
ROOF #2

13-7.90m, 2x3" ga.16 C-PURLINS


@ROOF #2 ROOF #1

ROOF #3

8.32 m

7.90 m
#1
8.95 m

1.45 m

#3
2.35 m

0.70 m #4
8.37 m ROOF #4

4.50 m

ROOF FRAMING PLAN ISOMETRIC VIEW


SCALE: 1:100 M SCALE: 1:100 M

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without CIVIL ENGINEER
4-BEDROOM S2
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2
S JB8
MASTERS'
BEDROOM

11- CONVENIENCE OUTLETS


C5
S JB7

GUEST'S RM. BEDROOM 2

S JB5 S

JB6 S
S JB4 1- WASHING MACHINE OUTLET T&B
C4
S
WM

BEDROOM 1

JB3 1- REFRIGERATOR OUTLET


C3 Ref
S
DINING
KITCHEN KITCHEN
DINING

BAR
S
JB2 Range

1- INDUCTION COOKER/
JB1 C2 RANGE OUTLET
LIVING

LIVING
S

BALCONY

C1 20- LIGHT OUTLETS

ELECTRICAL LIGHT LAYOUT CONVENIENCE OUTLET PLAN


SCALE: 1:100 M SCALE: 1:100 M

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without ELECTRICAL ENGINEER
4-BEDROOM E1
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2
ELECTRICAL SPECIFICATION
1. ALL ELECTRICAL WORKS MUST CONFORM TO THE PROVISIONS OF PEC 2009, THE RULES & REGULATIONS THE SITE
OF ALL LOCAL & NATIONAL AUTHORITIES CONCERNED IN THE PRACTICE OF ELECTRICAL ENGINEERING
AND SHALL BE IN ACCORDANCE WITH THE POLICY OF THE LOCAL UTILITY COMPANY.

2. SERVICE VOLTAGE TO THE BUILDING SHALL BE 22OV, SINGLE PHASE, TO BE SERVE THRU A 2P, _____AF,
_____AT,_____ KAIC ACB WITH 2 NO. ____SQ. MM THW WIRE IN 20 MM DIA. RMC PLUS 1- 5.5 SQ. MM TW, GEC.

TO
L
3. ALL BRANCH CIRCUITS INSTALLATION SHALL BE IN RIGID uPVC SERIES 1000 OR RIGID uPVC JAI

SU
SCHED.40, COMPLETE WITH PROPER FITTINGS. AL
CI
VIN

M-A
O
4. MINIMUN SIZE OF CONDUCTOR SHALL BE 3.5 SQ. MM TYPE THW/THHN COPPER WIRE, WITH INSULATIONS PR

G,
GOOD FOR 600 VOLTS, AND CONDUIT SHALL BE RUN 20MM NOMINAL DIAMETER.

B.C
5. ALL GROUNDING CONDUCTORS SHALL BE PROPERLY IDENTIFIED USING GREEN COLORED INSULATION OF
WIRES, AND IN NO OTHER PURPOSE SHALL GREEN COLORED CONDUCTOR BE USED IN THE ENTIRE INSTALLATION.

6. ALL ELECTRICAL WORKS SHALL BE DONE WORKMANLIKE EMPLOYING ONLY SKILLED & QUALIFIED
ELECTRICIANS UNDER THE SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER OR RME.

7. ALL METAL FRAMES & ENCLOSURES SHALL BE PROPERLY BONDED TO THE BUILDING GROUNDING SYSTEM.

SINGLE LINE DIAGRAM

TO
AB
UA
PB1 (PANEL BOARD NO.1) M

NA
N
90A 2P ACB
GND.
2 # 3.5 Sq. mm THHN Wire 15A 30A 2 # 5.5 Sq. mm THHN Wire
C1 C2

2 # 3.5 Sq. mm THHN Wire 20A 20A 2 # 3.5 Sq. mm THHN Wire
C3 C4
VICINITY MAP
2 # 5.5 Sq. mm THHN Wire 30A 30A 2 # 5.5 Sq. mm THHN Wire
C5 C6

2 # 3.5 Sq. mm THHN Wire 20A 20A 2 # 3.5 Sq. mm THHN Wire
C7 C8

Ground

SCHEDULE OF LOADS
PB1 (PANEL BOARD NO.1)
Circuit No. Qty. Load Description VA Current Volt Phase Protection Conductor

1 20 Light Outlets 1200 5.45 220 1P 15A 2P ACB 2-3.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
2 1 Induction Cooker Outlet 1800 8.18 220 1P 30A 2P ACB 2-5.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
3 1 Refrigerator Outlet 1500 6.82 220 1P 20A 2P ACB 2-3.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
4 1 Washing Machine Outlet 1500 6.82 220 1P 20A 2P ACB 2-3.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
5 11 Convenience Outlets 3300 15.00 220 1P 30A 2P ACB 2-5.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
6 1 SPARE 1800 8.18 220 1P 30A 2P ACB 2-5.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
7 1 SPARE 1500 6.82 220 1P 20A 2P ACB 2-3.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)
8 1 SPARE 1500 6.82 220 1P 20A 2P ACB 2-3.5 Sq. mm THHN Wire + 1-2.0 Sq. mm TW (G)

TOTAL 14100 64.09 220 1P 90A 2P ACB ________________________________________

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without ELECTRICAL ENGINEER
4-BEDROOM E2
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
said documents to duplicate or copy
said instruments.
PRC No.
PTR No.
Place:
Validity:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2
CO Tub
Lav
Tub
FD Lav THE SITE

4" Diameter PVC SANITARY PIPE


MASTERS' T&B
GV
BEDROOM
F
FD FD
WC Sho.
WC

TO
L
JAI

SU
L
CIA
VIN

M-A
O
PR

G,
B.C
GV

WC FD
4" Diameter PVC SANITARY PIPE Lav CO
Lav WC Sho.
SEPTIC VAULT

1 Sho.
VTR

Lav T&B GV
WC F T&B
FD WC

WB
2

TO
AB
KITCHEN GREASE TRAP

UA
0.40x0.60x0.70m

NA
4" Diameter PVC SANITARY OVERFLOW PIPE

N
Sink
GV
Sink
GT

VICINITY MAP

GV

TO P U B L I C D R A I N A G E A R E A

SANITARY LAYOUT FROM WATER SOURCE LINE WATER LAYOUT

PLUMBING PLAN
SCALE: 1:100 m

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without MASTER PLUMBER/ SANITARY ENGINEER
4-BEDROOM P1
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
PRC No. Validity:
said documents to duplicate or copy
said instruments.
PTR No.
Place:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2
3.60 m
0.90 m 0.90 m 1.40 m 12mm DSB Rebars
Spaced 0.15m O.C.
Bothways PLUMBING SPECIFICATION
LEGEND: VS VENT STACK
1. FOR SANITARY & VENT PIPE LINE, USE PVC PIPE AND FITTINGS.
OUTLET C.O. AV AIR VENT SS SOIL STACK 2. FOR WATER SUPPLY LINE, USE UPVC PIPE AND FITTINGS.
C.O.

0.60 m
0.90 m
1.10 m
1.10 m
0.90m

.60x.60m .60x.60m CB CATCH BASIN VTR VENT TRU ROOF


.60x.60m 3. PROVIDE INDIVIDUAL SHUT OFF FOR EACH FIXTURE BRANCH AND MAIN.
MANHOLE MANHOLE
MANHOLE
CO CLEAN-OUT SANITARY LINES 4. ROUGHING IN INSTALLATION FOR EACH TOILET ROOM SHALL GO ALONG WITH
THE CARPENTRY AND MANSORY PROGRESSES.
C.O. INLET DS DOWNSPOUT WATER LINES
5. ALL SURFACED CLEAN-OUT SHALL BE ACCESIBLE AT ALL TIME.
PLAN 4" CHB WALL with 10mm Dia. FD FLOOR DRAIN GV GATE VALVE 6. OTHER ASPECTS NOT FOUND ON THIS PLAN, THE PROVISION AND
DSB Reinforcement Bars in every
3 Layers, and 0.60m O.C. Vertical Bars REQUIREMENT OF NATIONAL PLUMBING CODE OF THE PHILIPPINES,
Lav WASH BASIN F FAUCET R.A. 1378 AND P.D. 1096 SHALL PREVAIL AT ALL TIME.
0.90 m 1.00 m 1.50 m
0.60 m 0.60 m 0.60 m SV SEPTIC VAULT 7. ALL PLUMBING WORKS SHALL BE UNDER THE DIRECT SUPERVISION OF
Sho SHOWER
THE MASTER PLUMBER IN CHARGEE OF INSTALLATION.
MANHOLE MANHOLE MANHOLE WC WATER CLOSET M WATER METER
0.50 m 0.50 m 0.50 m

0.40 m
0.50 m
0.60 m

INLET
AirSpace AirSpace
AirSpace

VTR
WATER LEVEL
OUTLET WATER LEVEL
WATER LEVEL
DIGESTIVE
2.20 m

2.00 m
2.20 m
CHAMBER

VTR
1.70 m
1.60 m
1.50 m

PERCOLATING LEACHING 4" CHB WALL


with 10mmDSB Reinforcement
Sho.
WELL WELL CO Lav
Bars in every 3 Layers, GV Tub
and 0.60m O.C. Vertical Bars
0.40x0.60x0.70m
KITCHEN GREASE TRAP PE
Y PI
TAR FD
ANI
PVCS FD
Sho. eter FD
iam
4" D
GV F
LT WC
0.90 m 0.90 m 1.40 m VAU
ELEVATION TIC
SEP FD WC
3.60 m GV WB Lav

Sink
4" D
SEPTIC VAULT DETAIL GV
iam
ete
r PV
CS Lav Sho.
SCALE: 1:40 Mts. ANI
GT TAR
YP
IPE
E
PIP WC
FLOW
R FD
OVE
ITARY CO
AN
CS
ter PV
me
4" Dia

GV M

FRO
MW TO
ATE PUB
RS LIC
OUR DRA
CE L INA
INE GE
ARE
A

ISOMETRIC VIEW
SCALE: 1:60 Mts.

Important: Certified by: Project Title: Approved by: Sheet No.


These drawings as instruments of service,
are the property of the owner/company.
It shall be unlawful for any person without MASTER PLUMBER/SANITARY ENGINEER
4-BEDROOM P2
the written consent of the authors of
RESIDENTIAL BUILDING MICHAEL L. JAMON JR.
PRC No. Validity:
said documents to duplicate or copy
said instruments.
PTR No.
Place:
Date:
TIN: Location: LOT 981-B-2-G, BRGY. TALOTOG, BAGO CITY Address:
Owner
2

You might also like