Make sure that you know how to disconnect power input to the dispenser and pump, in case of an
emergency. Have all leaks and faults repaired immediately.
Contact Yenen
Any problem relevant to the installation and operation of the Dispenser should be notified to an
authorized Yenen Service Partner or Yenen Technical Support Department. (+90 216 487 5924).
Explanation of Symbols
Warning: Indicates a hazard, which may cause serious personal injury damage to
property if not observed cautiously.
This handbook provides instructions and rules. Remarks and warnings inform the operator about the
dangers relevant to the installation and operation of LPG Dispensers. Reading these instructions and thus
preventing possible dangerous events is absolutely in the operator’s power. Any omission of this
responsibility is beyond Yenen’s control.
No part of Yenen handbooks may be reproduced, issued, copied and changed in any way and form without Yenen’s prior
written consent.
Yenen reserves the right to change the specifications of the products mentioned in this handbook at any time and without
prior notice.
Yenen may not be held liable for any damage arising from the use of this product.
Although every effort to make sure that the information in this handbook has been made, Yenen may not be held
responsible for any error in the content or incidental and consequential damages resulting from the use of this handbook
Yenen Engineering logo(s) are property of Yenen Engineering..
Yenen Engineering is ISO9001:2008 certified. If you request a copy of Yenen Quality Policy and/or Yenen HSE Policy,
please, visit www.yenen.com or send an e-mail to info@yenen.com or fax your request to +90 (216) 487 5986.
Page 3 of 45 19.10.2018 DIS-14-te Rev Nr:4
Table of Contents
Page
For any questions relevant to the installation and operation of the dispenser that are not covered in
this handbook, please contact Yenen through info@yenen.com or call +90 216 487 5924.
Page 5 of 45 19.10.2018 DIS-14-te Rev Nr:4
Yenen dispenser is a component of autogas filling system. All parts such as tanks, pumps, pipes and
fittings, anti-corrosion devices, cables (electrical and electronic), control system, etc. should be
furnished in compliance with the instructions of manufacturers and international and regional
standards. Yenen has no obligation to follow above-mentioned standards and codes or modify
products pursuant to the amendments made to those codes.
Yenen autogas dispensers may be used with Liquid Petroleum Gas (LPG) that is compliant with
TS11939, EN 14678-1 and EN 589.
ALWAYS disconnect the power supply before commencing maintenance. There may
more than one latch to disconnect. Use a multimeter to make sure that all circuits in
the dispenser are closed. Failure to take this precaution may cause personal injury.
Ensure that all valves are closed. It may be required to close more than one valve to
lock the system. To make sure that ALL valves are closed, review the station piping
diagram. Failure to take this precaution may cause personal injury.
Keep all vehicle and unauthorized staff at least 6 meters away from the dispenser.
Make sure that all required safety precautions have been taken. Make sure that all required
ventilation, fire protection, evacuation and fire procedures are provided.
Make sure that all fire extinguishing tools are easy to reach. Obtain comprehensive knowledge
about all safety regulations.
Read this handbook and all available literature and drawings.
Yenen recommends you to employ a qualified mechanical and electrical technician. As an
explosive liquid is being handled, it is compulsory to make sure that all safety precautions are
completely taken at any time.
Read DOs and DON’T’s in the appendix.
Page 6 of 45 19.10.2018 DIS-14-te Rev Nr:4
2.0 Installation
Examine the dispenser immediately upon delivery to make certain that no damage has been occurred.
Damaged or lost equipment should be informed to the carrier. Any damage or loss, which may occur
during shipping, is not covered under warranty.
Make sure that all components like switches and any optional equipment are present. Check invoice,
bill of lading and any similar document relevant to the purchase order and save a copy of them.
Take necessary safety actions at the work site. Consider the safety precautions
stated in the article 1.3 and DOs and DON’Ts in Appendix C.
Do not pour concrete around the liquid inlet and steam return lines or electrical conduits.
Instead, it is recommended to use sand or sandbags to prevent steam build-up under the
dispenser.
Unlatch and remove cap locks to reach the bottom section of the dispenser. Place the caps in a
place where they would not be damaged.
There are bolt holes on the bottom of the dispenser from anchoring it to the chassis. Tightly mount
the dispenser to the island.
.
Remove the plastic caps located on the liquid inlet and steam return line. There may be some test
liquid left in the dispenser and may pour out from one of the pipes.
Connect the liquid and steam return lines. Use flexible pipes in the connection of dispenser and
underground pipe tips in order to allow ground movement. Underground piping (steam return and
liquid lines) should be at least 1”.
Make sure that all connections are leak-proof when making pipe connections.
Use a liquid sealant compound, such as Loxeal 58.11 or other similar liquid compounds
(liquid sealant) that is used for LPG applications on male threads only. Be careful not to
let compound to leak into the fittings.
.
Page 10 of 45 19.10.2018 DIS-14-te Rev Nr:4
Make sure that all connections are tight and leak-proof when making pipe connections.
Use a liquid sealant compound, such as Loxeal 58.11 or other similar liquid compounds
(liquid sealant) that is used for LPG applications on male threads only. Be careful not to
let compound to leak into the fittings.
Connect hose assembly to the dispenser outlet and hose hooks to the side doors. If the dispenser
has a pipe retraction system, refer to the instructions for the connection as
well.
Connect the steel rope of the safety cable of the break-away coupling to
the dispenser frame. It is designed so that LPG is present on both sides of
the point, where break-away is located and it should be connected to each
hose. Only a couple cubic centimeters of LPG escape during removal.
Figure 2.2
Page 11 of 45 19.10.2018 DIS-14-te Rev Nr:4
ALWAYS make sure that the power supply is disconnected and locked before
commencing maintenance of the dispenser. There may be more than one button to
disconnect the power supply. Use a multimeter to make sure that ALL circuits of the
dispenser are closed. Failure to take these precautions may cause personal injury.
Electrical specifications:
A stable power supply is required for the operation of the electrical components within the
dispenser. Precautions should be taken thereof, where a stable and constant power
supply is not available.
For full service and stand-alone operation, make electrical installation in accordance with the
electrical connection scheme in the Appendix A.
A display lighting circuit that is connected to the power control circuit at the terminal adjustment
strip in the dispenser junction box is delivered along with the dispenser. The display lighting may
be connected to a separate circuit breaker or switch via those terminals. Jumping these terminals
shall keep display light activated permanently – see. Appendix A.
In addition to the connections required for stand-alone operation, the dispenser may be connected
to a remote host or POS system.
If optional data cables are required for future use, those should not be connected to the data
terminals in the junction box. Instead, separate glands should be used for each of them.
Do not connect the connections of the equipment irrelevant to the dispenser to the dispenser
wiring circuit. Those cables should be connected to another circuit.
Before applying power to the dispenser, double-check the connections to make sure that
the wires are connected and polarized correctly. See Section 3.
Before dispensing any product, make sure that above-ground pumps are commissioned.
– Refer to the manufacturer’s handbook thereof.
Turn on the dispenser power control circuit breaker, lighting circuit breaker, if connected, and
pump engine circuit breaker. Make sure that the dispenser is started-up. Dispenser displays shall
show a couple test messages and usually the last sale in the factory tests.
If the dispenser has not been powered or used for a while, an error message like “no electricity”
shall be shown due to discharged condensers. Wait for a while until the condensers are charged.
2.6.1 Preset
3.0 Operation
For accurate measurements, it important to set ATC in accordance with the LPG
compound.
Neglect this responsibility may result in inaccurate readings and it is beyond Yenen’s
control.
Dispenser should not be removed from its packing during transportation and storage
packaging.
Dispenser must be transported by paying attention to the directional arrows on the meter box
during the transportation.
Dispenser should be moved slowly and carefully. Otherwise CPU and displays may be
damaged.
Page 15 of 45 19.10.2018 DIS-14-te Rev Nr:4
Consider the safety precautions specified in the Section 1.3 when conducting any maintenance on the
dispenser. As long as the maintenance of a correctly installed dispenser is done appropriately and
regularly, it rarely needs an emergency service.
If you detect damage on the hose assembly, immediately cease to use the dispenser.
Continuing to operate it may result in personal injury and property loss. Close all valves
and fix hose assembly.
Check for sharp edges that may cause slashes on the casing.
Check hydraulics for leakage.
If you detect damage on the hose assembly, immediately cease to use the dispenser.
Continuing to operate it may result in personal injury and property loss. Close all valves
and fix the leakage. (See Section 2.4)
As the LPG taken from the refinery may contain water, dirt and aggressive hydrocarbons, check
the tank regularly. Contaminated LPG may cause serious damage in the dispenser. (See Section
1.1)
Use only genuine spare parts provided by Yenen on the dispenser. Using spare parts other than
genuine Yenen spare parts may impose safety risks and therefore shall violate all obtained
permissions and warranty.
5.3 Filter
Generally speaking, a clogged filter shall slow down the flow rate. For new installations, it may be
necessary to replace filter several times within the first week of operation, as there may be some
debris and pipe insulation parts left from the installation.
Depending on the quality of gas, the filter should be replaced for every 1 million liters, 6 months or
if flow rate slows down.
A 2 bar or more difference at the pump outlet and dispenser liquid line during the operation of the
dispenser and pump indicates that the filter is clogged.
Read Yenen’s filter replacement instructions. ITL-SRV-7.5.1-008
Page 16 of 45 19.10.2018 DIS-14-te Rev Nr:4
Some precise measurement parts are sealed in order to restrict their repair and
modification. Only authorized and certified persons may break and reseal those.
For the adjustment of the dispenser, follow the procedures that are defined by local authorities and
read Yenen LPG flow meter and operation handbook. LFM-02.
Sales
Priority Description İnformation Screen Result of Error Occurence Action Required
Screen
45 ATC Unmatched E-45 ATC Unmatched Filling not possible Anytime Service required
46 No Limit Select E-46 No Limit Select Filling not possible Anytime Select Limit
47 Tube Not Ready E-47 Tube Not Ready Filling not possible Anytime Put on Tube
48 Tube over Limit E-48 Tube over Limit Filling not possible Anytime Change Tube
Page 33 of 45 01.01.2014 DIS-14-te Rev Nr:3
1 NOZZLE DISPENSER
Page 34 of 45 01.01.2014 DIS-14-te Rev Nr:3
2 NOZZLE DISPENSER
Page 35 of 45 01.01.2014 DIS-14-te Rev Nr:3
0.5 Ampers
GROUNDING
1 Amper
9 8 7 6 5 4
220 V
Relay
5. Emergency Stop Neutral
9 8 7 6 5 4 2
6. Emergency Stop Parallel 21 20 3 1
7. Emergency
8. Grounding 24 23 22
9. Solenoid Neutral
BROWN FAST SLOW
BROWN
Motor-C1
Motor-C2
Common
Common
Common
Common
P1-Motor
P2-Motor
P3-Motor
P4-Motor
P1-Valve
P2-Valve
P3-Valve
P4-Valve
Neutral
Phase
SD Card
Earth
Socket
1 2 3 4
220 VAC
Pump 1 - 4 Motor & Valve
DISPLAY (A) ATC
12C Bus- 1
TOTALIZER
ATC1
BOARD
S4S
12C Bus- 2
Status
RXD
TXD
ATC1
COMPUTER
MKS DISPLAY
12C Bus- 3
ATC2
PULSER-1 PULSER-2 PULSER-3 PULSER-4 NOZZLE 1 - 4 RS485 / CL
12C Bus- 4
ATC2
RS485-A
RS485-B
P1-PWR
P2-PWR
P3-PWR
P4-PWR
P1-GND
P2-GND
P3-GND
P4-GND
P1-CHA
P1-CHB
P2-CHA
P2-CHB
P3-CHA
P3-CHB
P4-CHA
P4-CHB
P1- SW
P2- SW
P3- SW
P4- SW
C
GND
GND
CL +
CL - 1 2 3 4
BROWN
GREEN
5 6 7 8
WHITE Grnd.
YELLOW Grnd.
Prest 4
9 0
Prest 3
Prest 2 PRESET PRESET
(+) (-)
Prest 1
10 10
PULSER (A)
B A
PRESET BUTTON
Page 36 of 45 01.01.2014 DIS-14-te Rev Nr:3
TERMINALS BLUE
BLUE
BLUE
1. Phase 220V BLUE
2. Neutral 17 16
3. Motor Signal 220V
19 18
4. Emergency Stop Phase 220V
0.5 Ampers
GROUNDING
1 Amper
9 8 7 6 5 4
220 V
Relay
5. Emergency Stop Neutral
9 8 7 6 5 4 2
6. Emergency Stop Parallel 21 20 3 1
7. Emergency
8. Grounding 24 23 22
Motor-C1
Motor-C2
Common
Common
Common
Common
P1-Motor
P2-Motor
P3-Motor
P4-Motor
P1-Valve
P2-Valve
P3-Valve
P4-Valve
Neutral
Phase
SD Card
Earth
Socket
1 2 3 4
220 VAC
Pump 1 - 4 Motor & Valve
DISPLAY (A) ATC
12C Bus- 1
TOTALIZER
ATC1
BOARD
S4S
12C Bus- 2
Status
RXD
TXD
ATC1
COMPUTER
MKS DISPLAY
12C Bus- 3
ON
ATC2
1 2 3 4 PULSER-1 PULSER-2 PULSER-3 PULSER-4 NOZZLE 1 - 4 RS485 / CL
12C Bus- 4
ATC2
RS485-A
RS485-B
P1-PWR
P2-PWR
P3-PWR
P4-PWR
P1-GND
P2-GND
P3-GND
P4-GND
P1-CHA
P1-CHB
P2-CHA
P2-CHB
P3-CHA
P3-CHB
P4-CHA
P4-CHB
P1- SW
P2- SW
P3- SW
P4- SW
DISPLAY (B) C
GND
GND
CL +
CL -
1 2 3 4
BROWN 5 6 7 8
YELLOW
BROWN
GREEN
WHITE
GREEN
WHITE Grnd.
YELLOW Grnd.
Prest 4
9 0
Prest 3
Prest 2 PRESET PRESET
(+) (-)
Prest 1
10 10
PULSER (A) PULSER (B)
B A
PRESET BUTTON
Page 37 of 45 01.01.2014 DIS-14-te Rev Nr:3
TROUBLESHOOTING
HOW TO FIX THE PROBLEM IF
PROBLEM POSSIBLE CAUSES? WHAT TO CHECK?
DETERMINED?
a) Fuse in the CPU is blown. a) Check the fuse in the CPU. a) Replace the fuse.
b) Power section of CPU card that
b) Check the CPU card. b) Replace the CPU card.
powers solenoids may be broken.
c) Solenoid coil may be burnt. c) Check if solenoid inducts or not. c) Solenoid should be replaced if broken.
d) Open valves if closed, replace nitrogen
Dispenser is not activated d) Pneumatic valves may be closed. d) Check if the valves are open.
tube if necessary.
even though it is switched
e) Engine should be replaced if not
“on”. e) Engine may not generate pressure. e) Check the engine.
generating pressure.
f) Check if a signal is received from the f) Make sure that signal is received from
f) No signal from the relay.
relay. relay.
g) On-off switch is broken. g) Check the button. g) Replace the button if broken.
h) Thermic on the table may be
h) Check the thermic. h) Thermic should be corrected if blown.
blown.
a) Pulser may be broken. a) Check the pulser. a) Pulser should be replaced.
TROUBLESHOOTING
HOW TO FIX THE PROBLEM IF
PROBLEM POSSIBLE CAUSES? WHAT TO CHECK?
DETERMINED?
a) Distribution valve, Charcoal, Felt may be a) Check distribution valve, charcoal
a) Replace broken part.
damaged. and felt.
b) Adjustment roller may need readjustment. b) Check the adjustment roller. b) Readjust the adjustment roller.
Dispenser delivers too much or too c) Pulser may be broken. c) Check the pulser. c) Replace the pulser.
little d) Pulser shaft may have torsion.. d) Check the pulser shaft. d) Fix the torsion.
e) Piston arms may be twisted. e) Check the piston arms. e) Replace the piston arms.
f) Piston cups may be torn or worn
f) Check the piston cups. f) Replace the piston cups.
.
a) Filter may be clogged. a) Check the filter. a) Change the filter.
b) Solenoids may be clogged or solenoid core b) Clean solenoid, replace the core,
b) Check the solenoids.
may leak. and replace solenoid if necessary.
c) Diver may not generate sufficient pressure. c) Check the manometer on the diver. c) Replace the diver pump.
Dispenser flow rate is less than d) Change the position of two phase
d) Check the diver pump revolution
expected. d) Direction of the diver pump may be wrong. cables of the diver pump on the
direction.
control panel.
e) Differential rubbers may be torn. e) Check the differential valve. e) Replace the differential rubbers.
f) Break-away coupling may be clogged, f) Clean the break-away coupling,
f) Check the break-away coupling.
broken or misplaced. replace it if broken.
g) Nozzle may be damaged. g) Check the nozzle. g) Replace the nozzle.
h) Vehicle tank may be full. h) Check the lever on the tank. h) Stop filling the vehicle with full tank.
I) Loosen and tighten adjustment
I) Pulser shaft may be jammed. I) Check the pulser shaft.
bolts.
Page 39 of 45 01.01.2014 DIS-14-te Rev Nr:3
TROUBLESHOOTING
HOW TO FIX THE PROBLEM IF
PROBLEM POSSIBLE CAUSES? WHAT TO CHECK?
DETERMINED?
a) Preset or its connections may be short a) Correct the connections and
Price counter does not stop. a) Check the connections.
circuited. change preset if situation persists.
a) Pr-In keys on the CPU may be jammed. a) Check the keys on the CPU. a) Fix the problem by pressing keys.
Unit price window blinks.
b) CPU cap may be broken. b) Check the CPU cap. b) Replace the CPU cap.
a) Parameters are entered incorrectly into a) Check the parameters entered into
a) Re-enter parameters accurately.
Display shows incorrect price. CPU card. CPU card.
b) Solenoids may leak. b) Check the solenoids. b) Replace solenonids.
a) Display temperature may be more than 40o. a) Problem shall be fixed when
a) Check the display temperature.
(display is erased in this case) display temperature is normal.
Nothing on display. b) Display card may be broken. b) Check the display card. b) Replace the display card..
c) There may be problem on display
c) Check the display connections. c) Connect cables correctly.
connections.
a) Break-away coupling on the hose may be a) Check if break-away coupling is a) Firmly place or replace break-away
closed. placed correctly. coupling.
Nozzle does not deliver gas even b) Solenoid valves may not open. b) Check if solenoid valves are opening. b) Replace solenoid valves.
though it is switched “on” and
diver is activated. c) Pneumatic valves may be closed. c) Check if nitrogen tube is full or not. c) Replace nitrogen tube.
d) Replace in-nozzle check valve if
d) Check valve in the nozzle may be broken. d) Check the in-nozzle check valve.
broken.
Page 40 of 45 01.01.2014 DIS-14-te Rev Nr:3
TROUBLESHOOTING
HOW TO FIX THE PROBLEM IF
PROBLEM POSSIBLE CAUSES? WHAT TO CHECK?
DETERMINED?
a) Break-away coupling may have a) Check the break-away coupling on a) Place the break-away coupling into
come away. the hose. position.
b) Nitrogen tube may be empty. b) Check the nitrogen tube. b) Replace the nitrogen tube.
Dispenser does not deliver gas.
c) CPU fuse may be blown. c) Check the fuse. c) Replace the CPU fuse.
d) Nozzle may be broken. d) Check the nozzle. d) Replace the nozzle.
e) Solenoids may be broken. e) Check the solenoids. e) Replace the solenoids.
a) PR button on the CPU card may be
Display flashes at any parameter. a) Observe dispenser display. a) Press PR key until EP is displayed.
stuck.
a) Press gas alarm reset key for 3
a) There may be gas leakage. a) Check for leakages on all systems.
Gas alarm sounds. seconds.
b) Gas detector may be broken. b) Check the gas detector. b) Replace the gas detector.
a) Thermic relay may be out of a) Check the current drawn from the
a) Replace the diver pump.
Thermic relay on the panel blows adjustment. network by the pump.
continuously. b) Thermic relay may be out of
b) Check the thermic relay. b) Adjust thermic relay.
adjustment.
a) Remove washer and reverse it.
a) Washer located on the tip of the
a) Check the nozzle washer. Replace the washer if problem
nozzle may be worn.
Nozzle leaks gas. persists.
b) Threads of the nozzle may be
b) Check the nozzle. b) Replace the nozzle.
broken.
a) Totalizer’s coils may be broken. a) Check the totalizers. a) Replace the totalizers.
b) Dispenser control unit may not be
Totalizer does not work. b) Check the CPU card. b) Replace the CPU card.
sending signals to totalizers.
c) Graphics card may be broken. c) Check the graphics card. c) Replace the graphics card.
Page 41 of 45 01.01.2014 DIS-14-te Rev Nr:3
TROUBLESHOOTING
HOW TO FIX THE PROBLEM IF
PROBLEM POSSIBLE CAUSES? WHAT TO CHECK?
DETERMINED?
a) Safety valve may leak. a) Check the safety valve. a) Clean any dirt if exists.
b) Parameter values may be
Display continues to count even b) Check the parameter values. b) Adjust parameter settings.
interfered.
though the nozzle is disconnected.
c) CPU card may be broken. c) Check the CPU card. c) Replace the CPU card.
d) Pulser may be broken. d) Check the pulser. d) Replace the pulser.
a) Pump pressure may be drooped. a) Check the pump pressure. a) Replace the pump if broken.
b) Electrical interruption. b) Check the voltage. b) Restore electrical connection.
c) Pressure sensor may be broken. c) Check the pressure sensor. c) Replace the pressure sensor.
Delivery stops while dispensing gas. d) Analog adjustment may be
d) Check the analog values. d) Adjust the analog values.
incorrect.
e) Gas sensor may be interrupting gas
e) Perform leakage test on al systems. e) Fix found leaks.
flow due to a leakage.
a) Fluorescent may be died out. a) Check the Fluorescent. a) Replace Fluorescent.
Dispenser Fluorescent is off. b) Fluorescent fuse may be blown. b) Replace the fuse.
c) Fluorescent may be loosened. c) Place fluorescent correctly.
Dispenser Manometer is not working. a) Manometer may be broken. a) Check the manometer. a) Replace the manometer.
Page 42 of 45 01.01.2014 DIS-14-te Rev Nr:3
DO FOLLOWING
DO…
Consult with station director or administrator about the project and procedures before servicing a
dispenser.
Review dangerous zones on the work site and determine necessary safety precautions relying on
your safety training and experience.
Locate extinguishers on the work site before commissioning any process involving LPG.
Disconnect and lock power supply before opening the dispenser for maintenance. Make sure that
valves under the dispenser are closed BEFORE commencing maintenance.
Utilize equipments like safety cones, barricades and barrier bands in order to isolate work site and
protect technician.
Get totalizer results and record them in co-ordination with station director or administrator.
Page 43 of 45 01.01.2014 DIS-14-te Rev Nr:3
DO NOT FOLLOWING
DON’T…
Do not allow unauthorized persons to stay close to the dispenser or work site during demounting
or gas discharge of the dispensers.
Do not allow smoking, igniting or fire devices within the perimeter of the work site.
Do not remove safety cones, barrier band or service vehicle until the work is completed.
Do not leave station without having report signed by station director or administrator.
44