LT3054

IC730

TEST DRIVER / KOEAJAJA

UNIT TYPE / KONETYYPPI

UNIT SERIAL NUMBER / KONEEN


SARJANUMERO

PARAMETERS IN THE DISPLAY


UNIT - NORMAL
Language selection X
Date X
Time X
UCD contrast X
Metric/Imperial units Met
Magnetic separator ON/OFF OFF
Hydraulic outlet ON/ON with OFF
process/OFF
Side conveyor ON/OFF OFF
Screen module rotation direction, FRW
forward / Reverse direction (material
flow)
Feeder bottom heater ON/OFF OFF
PARAMETERS IN THE DISPLAY
UNIT - SERVICE
Restore/save factory settings X

GENERAL
GS1 Delay between device start, 5
default 5 sec, range 1-15 sec.
G2 Delay after feeder stopping in process 20
stop sequence, default 20 sec, range
10-45 sec.
GS3 Delay between the device shut down, 10
default 10 sec, range 5 -45 sec.

GS4 Vibration chute not in use “0” in use 0


“1”, in use with electric motor “2” (value
can be changed only when process is
stopped)
GS5 Generator monitoring not in use (0), in 0
use, with digital monitoring(1), in use,
with analog monitoring(2)
G6 Bypass conveyor not in use “0”, in use ---
“1”, in use with electric motor “2”

G8 Dust removal fan time, default 120min, 60


range 1-180min
G9 Dust removal vibrating time, 120
default 10sec, range 5 – 200sec.

N11450562(6.0)
Created 1.9.2004 by PNi 1/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

G10 Return conveyor not in use “0”, in use 0


“1”, in use with electric motor “2” (value
can be changed only when process is
stopped)
GS11 Unit type selection: ---
3 = LT200HP, 4 = LT300HP
(value can be changed
only when engine is
stopped)
GS13 LC-feeder in use (1), not in use (0) ---
GS14 Hydraulic outlet in use (1), not in use ---
(0)
GS15 Scalper not in use "0", in use with 0
vibrating grizzly "1", in use with roller
grizzly "2" (value can be changed only
when process is stopped)
G16 Magnetic separator not in use “0”, in 0
use with hydraulic use “1", in use with
electromagnet "2", with electric use
"3", electric use with electromagnet "4"
(value can be changed only when
process is stopped)(IC700 range 1-2)

G17 Side conveyor not in use “0”, in use 0


G20 Electric outlet 1 in use (1), 0
not in use (0) (value can be changed
only when process is stopped)
G21 Electric outlet 2 in use (1), 0
not in use (0) (value can be changed
only when process is stopped)
GS22 Feeder bottom heater not in use “0”, 0
hydraulic use “1”, electric use “2”
GS27 Main conveyor with hydraulic use (1), 1
with electric use (2) (value can be
changed only when process is
stopped)
GS28 Unit type selection: 12
1 = LT95, 2 = LT96, 3 = LT105, 4 =
LT106, 5 = LT116, 6 = LT110C, 11 =
LT110, 12 = LT3054, 13 = LT125, 14 =
LT140, 21 = LT1110, 22 = LT1213, 23
= LT1213NEW, 31 = LT1315, 32 =
LT1415, 33 = LT1417, 34 = LT1520
(value can be changed
only when engine is
GS29 Hydraulic opening for crusher feed ---
gate in use (1), not in use (0) (value
can be changed only when process is
stopped)
GS30 Automatic belt tensioning system in 1
use (1), not in use (0) (value can be
changed only when engine is stopped)

N11450562(6.0)
Created 1.9.2004 by PNi 2/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

GS31 Generator voltage 4mA measurement 0


value, range 0-1000.
GS32 Generator voltage measurement 0
range, range 0-1000.
GS33 Generator low voltage alarm limit, 0
default 360V, range 0 – 600. If set to
0, not in use.
GS34 Generator low frequency alarm limit, 0
default 45Hz, range, 0 - 65. If set to 0,
not in use.
GS35 Dust removal drive type, not in use (0), 0
in use (1), in use with electric motor (2)

GS36 Crusher dust seal air blower circuit ---


monitoring, not in use (0), feed react
(1), process react (2)
GS37 Control centre air blower circuit ---
G38 Water pump monitoring, not in use (0), ---
in use (1)
GS39 Unit type IC800, ---
1 = LT200GP
2 = LT300GP
GS40 Engine rpm increase ramp fastness, 200
default 100 rpm / sec., range 1 - 1000
rpm / sec.
GS41 Engine rpm decrease ramp fastness, 200
default 100 rpm / sec., range 1 - 1000
rpm / sec.
G42 Conveyors belt roller diameter, default 108
108mm, range 50-200mm.
GS43 Accessory pump(s), not in use (0), in 1
use (1), in use according to unit's load
(2)
GS44 Device work position limit switch, not in ---
use (0), in use (1)

G45 Metal detector, in use 1, not in use 0, ---


default 0
GS46 Upper level communication, enabled = 0
1, disabled = 0, default 0
GS47 Upper level communication baudrate, 250
range according to standard, default
250
GS48 Upper level communication ID, range 15
according to standard, default 1

GS49 Unit type IC400, ---


1 = LT7150
GS50 Vibration & tilt sensor, 0 = not in use, 1 ---
= CAN, 2 = I/O
GS51 Longest allowed process start ---
duration, default 10min, range 0-
120min

N11450562(6.0)
Created 1.9.2004 by PNi 3/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

GS52 Unit type selection: ---


1. LT110E 2. LT3054E
3. LT125E 4. LT140E
5. LT1315E 6. LT1415E
7. LT1418E 8. LT1520E
(value can be changed
only when engine is
stopped)
GS53 Electric motors' feedback delay, ---
default 10 sec., range 0 - 30
GS54 Power source monitoring, (0) none, (1) 1
thermistor, (2) phase sequence,(3)
thermistor and phase sequence

GS55 Adjusting pump, "1" Hydraulic motor, ---


"2" Electric motor,
GS56 Hydraulic outlet, "0" not in use, "1" in ---
use, "2" in use with process, "3" in use
with heating
GS57 Inclination offset longitudinal Y, default ---
0,0°, range -30,0° – +30,0°
GS58 Inclination offset transversal X, default ---
0,0°, range -30,0° – +30,0°
GS59 Inclination Y, longitudinal max level, ---
default 2,0°, range 0,0° – 30,0°
GS60 Inclination X, transversal max level, ---
default 1,0°, range 0,0° – 30,0°
GS61 Tilt sensor mounting, positive tilt ---
values affect, 0 = sensor not in use, 1
= X clockwise - Y clockwise, 2 = X ccw -
Y cw, 3 = X ccw - Y ccw, 4= X cw - Y
ccw, default 0, range 0-4
GS62 Return conveyor sequence start 1
position, “1” after screen, “2” before
screen
FEEDER
F1 Feeder MIN speed, default 63%, range 1
55-70% (IC5xx adjusted by feeder
rpm)
F2 Feeder MAX speed, default 70%, 100
range 60-90%, MAX speed must be
higher than MIN speed (IC5xx
adjusted by feeder rpm)
F6 Level sensor ON(1)/OFF(0) 1

F9 Crusher pressure HIGH limit , default ---


300 bar, range 200-400 bar

FS10 Crusher pressure high limit time delay, ---


default 3 sec, range 1-20 sec
F12 Crusher speed LOW limit, default 275 ---
rpm, range 100-350 rpm

N11450562(6.0)
Created 1.9.2004 by PNi 4/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

F13 Crusher speed low limit time delay, 1


default 1 sec, range 0-10 sec
FS15 Hydraulic oil temperature HIGH limit , 90
default 85 °C, range 70-90 °C
F16 Crusher level high alarm delay , 5
default 5 sec, range 1-20 sec
FS17 Feeder start minimum speed time, 5
default 5 sec, range 1-20 sec (if FS43
= 1, then set to 1 sec.)
FS20 Feeder-hopper analog level detector ---
0% mA- value, default 18mA, range 4 -
19mA
FS21 Feeder-hopper analog level detector ---
F22 Crusher level high delay , default 3 3
sec, range 0-30 sec
F23 Feeder-hopper low cavity level default ---
25%, range 0-100%
F24 Feeder-hopper high cavity level, ---
default 90% , range 0-100%
F25 Lifting conveyor acceleration and ---
deceleration ramp time ( time from min
to max ), default 3sec, range 0 – 30
sec.
F26 Lifting conveyor min speed, default ---
50%, range 0 – 100%
F27 Lifting conveyor max speed, default ---
80%, range 0 – 100%
F28 Feed hopper analog level detector in ---
use, default 0, range 0 – 1
F29 Crusher level OK delay , default 3 sec, 3
range 0-30 sec
F30 Metal detector stop time, default 0
0,5sec, range 0 – 5.0sec. (if set to 0
metal detector not in use)
F31 Lifting conveyor min speed time, ---
default 8sec, range 0 – 15sec.
FS32 Feeder speed sensor, detected pulses 38/47*
per one round, default 38, range 0-
100, if set to zero sensor not in use. (*
With one peace feeder (GS15 = 0))

F33 Hydraulic oil slow down limit, default 85


75deg C, range 60 – 90 deg C,

F35 LC-feeder min speed, default 50%, ---


range 0 – 100%
F36 LC-feeder max speed, default 80%, ---
range 0 – 100%
FS37 Scalper overspeed alarm limit, default 1050
0 rpm, range 0 – 1200 rpm, if set to
zero sensor not in use.

N11450562(6.0)
Created 1.9.2004 by PNi 5/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

FS39 Scalper speed sensor, detected 47


pulses per one round, default 47,
range 1-100
F41 LC-feeder min speed start time, ---
default 3 sec. range 0 –10 sec.
F43 Cavity level sensor type “0” not in use, 2
“1” analog, “2” digital.
Default “1” range 0-2
F44 Cavity level sensor 0% mA-value, 20
default 18mA, range 4 – 20 mA
F45 Cavity level sensor 100% -value, 4
default 5mA, range 4 – 20 mA
FS46 Feeder control Minimum PWM, 95%, ---
range 50 - FS47%
FS47 Feeder control Maximum PWM, ---
55%%, range FS46 - 95%
F48 Crusher power HIGH limit, default ---
150kW, range 100 – 400kW
F49 Power high feed pause delay, default 5 ---
sec, range 1-20 sec
F50 Crusher low speed alarm limit;Target 20
speed - set value = activation value .
F51 Engine power target level exceeded 10
delay, default 10sec, range 1-20 sec.

F53 Engine excessive power delay, default 10


10s, range 1 - 20 s
F54 Adapting calculation, period of time, ‘0’ 5
not in use, default 5min, range 0-
60min
F57 Autom speed, Cavity level alarms 10
counter MAX value, “0” not in use,
default 10, range 0-30 (max needs to
be higher than min value)
F58 Autom speed, Cavity level alarms 5
counter MIN value, default 5, range 0-
30 (min needs to be lower than max
value)
F59 Autom speed, Secondary LT high load 0
alarms counter MAX value, “0” not in
use, default 10, range 0-30 (max
needs to be higher than min value)

F60 Autom speed, Secondary LT high load 5


alarms counter MIN value, default 5,
range 0-30 (min needs to be lower
than max value)
FS65 Feeder control current at 0 rpm, 480
default 400mA, range 0 - 1000mA
(needs to be lower than max speed
value)

N11450562(6.0)
Created 1.9.2004 by PNi 6/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

FS66 Feeder control current at maximum 600


speed, default 530mA, range 0 -
1000mA (needs to be higher than min
speed value)
F67 Delay before feeder can restart after 0
been paused, default 10 sec., range 0 -
30 sec.
F68 Scalper operation when feeder is 0
paused, none "0", pause "1"
F69 Stop delay time, if generator 5
voltage is low, default 5 sec.,
range 0-30sec.
F70 Stop delay time, if generator 5
frequency is low, default 5 sec.,
range 0-30sec.
F71 Cavity target level, default 50%, range 50
0 – F72%.
F72 Cavity level feed stop limit, default 70
70%, range (F71 - 100%)
F73 Stop delay time, secondary unit pause 45
request is active, default 20sec. ,
range 0-60sec.
F74 Hydraulic oil low temperature limit, -10
default 0°C, range -15 – 25°C,
F75 Stop delay time, if device pump 1, 2 or 20
3 pressure is high, default 30 sec,
range 0-90sec.
FS76 Lifting conveyor speed on 100% ---
control, default 2,6m/s, range 0 -
4,0m/s.
F77 Metal detector sensor distance from ---
the service hatch, default 2m, range 0 -
15m.
FS78 Feeder acceleration and deceleration 3
ramp time, default 3sec, range 0 – 30
sec.
FS79 Feed target control, Proportional value, 0,9
default 1, range 0,01 - 1000
FS80 Feed target control, Integral value, 15,0
default 1000sec., range 0,01 - 1000
sec.
FS81 Feed target control, Derivative value, 0,0
default 0,01 sec., 0,01 - 1000 sec.
F82 Feed control % for primary unit pause 1
request, default 30%, range 0 - 100%

F83 Stop delay time, if discharging 10


conveyor speed is low, default 10 sec,
range 0-20sec.
F84 Stop delay time, if lifting conveyor ---
speed is low, default 10 sec, range 0-
30sec.

N11450562(6.0)
Created 1.9.2004 by PNi 7/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

FS85 Ultrasonic level sensors signals low- 0,1


pass cut-off frequency, default 5Hz,
range 0,1 - 25Hz
F86 Lifting conveyor low speed limit, ---
default 1,2m/s, range 0 - 4,0m/s.
F87 Main conveyor low speed limit, default 1,2
1,2m/s, range 0 - 4,0m/s.
F88 Side conveyor low speed limit, default ---
1,2m/s, range 0 - 4,0m/s.
F90 Crusher low speed alarm limit default ---
900rpm, range 0 - 1500rpm
F91 Scalper MIN speed PWM-value, ---
default 55%, range 50-99%
F92 Scalper MAX speed PWM-value, ---
default 90%, range 51-100%
FS93 Lifting conveyor valve max control ---
value, default 80%, range F27 - 100%

FS94 Feeder valve max control value, ---


default 80%, range F36 - 100%
F95 Return conveyor low speed limit, ---
default 1,2m/s, range 0 - 4,0m/s.
F96 Crusher power target level, default ---
200kW, range 0-400kW
FS97 Automatic feed control, by engine load 2
(1), cavity level (2) or Crusher
F98 pressure
Adapting (3)
calculation, feed speed 5
change step. in x 1% or in x 1kW,
default 5, range 1-20
F99 Engine power target level, range ES24- 95
ES25 %
FS100 Feeder proportional valve with current 1
control (1), with voltage control (2)
(value can
FS101 Crusher be changed
excessive only when
low speed alarm 30
limit;Target speed - set value =
activation value
F102 Crusher pressure target level, default
---
180, range 100 - F9bar
FS103 Feed valve current control, coil
resistance, default 17Ohm, range 0-30 ---
Ohm
FS104 Lifting conveyor proportional valve with
current control (1), with voltage control ---
(2)
FS105 Lifting conveyor control current at 0
rpm, default 400mA, range 0 – ---
FS106mA
FS106 Lifting conveyor control current at
maximum speed, default 530mA, ---
range FS105 - 1000mA.
FS107 Lifting control Minimum PWM, default
---
55%, range 50 – FS108%

N11450562(6.0)
Created 1.9.2004 by PNi 8/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

FS108 Lifting control Maximum PWM, default


---
95%, range FS107 - 95%
CRUSHER
CS1 Crusher max current, default 520 mA, ---
range 200 - 800 mA.
CS2 Crusher min current, default 250 mA, ---
range 100 - 400 mA
CS4 Minimum clamping pressure, default 140
135 bar, range 80-300 bar. (xx =
Adjust according to hydraulic diagram,
note ASC limits)
CS5 Maximum clamping pressure, default 155
145 bar, range 100-300 bar. (xx =
Adjust according to hydraulic diagram,
note ASC limits)
CS6 Crusher starting low pressure alarm ---
limit, default 50 bar, range 0-200 bar
CS7 Crusher starting low pressure alarm ---
delay, default 10 s, range 0-60 s
CS8 Crusher starting high pressure alarm ---
limit, default 200 bar, range 100-300
bar
CS9 Crusher starting high pressure alarm ---
delay, default 5 s, range 0-30s
CS10 Low clamping pressure, default 120 120
bar, range 80-180 bar (xx = Adjust
according to hydraulic diagram, note
ASC limits)
CS11 Crusher over pressure alarm delay, ---
default 10s, range 1 - 20 s
CS12 Crusher over pressure alarm limit, ---
default 300 bar, range 100 - 400bar
CS17 Critical overload limit from Crusher ---
setting range, default 5%, range 0 –
20% movement, overload limit,
CS18 Setting ---
default 15mm, range 0 – 50 mm
C19 Crusher speed sensor in use (1), not 1
in use (0)
C20 Crusher drive, idle speed delay, ---
default 15 sec., range 1-90 sec.
C21 Crusher drive, idle speed, default 400 ---
rpm, range 200-2100 rpm
C22 Crusher drive, current for crusher idle ---
speed, default 280mA, range 200-
800mA
C23 Crusher drive, idle pressure, default ---
50, range 0 -400bar
C24 crusher target speed 1, default 500, 260
range 400-1050rpm
C25 crusher target speed 2, default 650, ---
range 400-1050rpm
(LT200HP/300HP range CS63- CS64)

N11450562(6.0)
Created 1.9.2004 by PNi 9/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

C26 crusher target speed 3, default 850, ---


range 400-1050rpm
(LT200HP/300HP range CS63- CS64)

CS27 crusher speed sensor, detected pulses 1


per one round, default 1, range 1-50

CS28 Pump zero speed for crusher target ---


speed1, default 529mA, range 200-
750mA, IC500 range CS2-CS1
CS29 Adjust motor zero speed for crusher ---
target speed1, default 0 mA, range
200-750mA
CS30 Pump zero speed for crusher target ---
speed2, default 600mA, range 200-
750mA
CS31 Adjust motor zero speed for crusher ---
target speed2, default 225 mA, range
200-750mA
CS32 Pump zero speed for crusher target ---
speed3, default 600mA, range 200-
750mA
CS33 Adjust motor zero speed for crusher ---
target speed3, default 225 mA, range
200-750mA
CS34 crusher target speed change ---
hysteresis, default 30rpm, range 5-
CS35 100rpm pump ramp fastness mA/sec,
Crusher ---
default 30, range 1 – 50mA / sec

C36 crusher auto speed. 0=not in use 1=in ---


use

CS40 Clamping fault delay, default 1sec. ---


range 0 – 60sec.

CS41 Release fault delay, default 1sec. ---


range 0 – 60sec.
CS42 Crusher excessive power alarm limit, ---
default 145 kw, range 100 - 400 kW
CS43 Crusher excessive power alarm delay, ---
default 10s, range 1 - 20 s
CS46 HP-setting change per tooth, default ---
0,18mm range 0,10 – 0,39mm
CS50 hydraulic pump size, default 250cm3 , ---
range 50 - 500cm3

N11450562(6.0)
Created 1.9.2004 by PNi 10/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

CS51 Crusher drive type, Distribution 1


gearbox (1), Hydraulic drive with pump
control (2), Hydraulic drive with pump
and motor control (3), Electric drive
(4), Electric drive with direction change
(5)

CS52 Crusher pump control low limit, default ---


600mA, range CS2- CS1

C53 Crusher control percent, default 50%, ---


range 1 - 100%

CS58 Feeder stop time before setting can be 30


changed, default 30sec. range 10-
120sec.
CS59 Setting sensor in use “1”, “0” not in 0
use. Default “0”, Range 0-1
CS60 Crushing hours to notify user about 40
bearings lubrication. Default 40h range
0 – 250h
CS61 Crushing hours to notify user about ---
counter weight liner and arm liners
cleaning. Default 20h range 0 – 250h
CS62 Crusher target speed change 1
allowed ”0” = not allowed,
“1” allowed, "2" speed and control
change allowed
CS63 Crusher target speed range 245
minimum limit. default = 800rpm
range 400- 1300rpm
CS64 Crusher target speed range 270
maximum limit. default = 1000rpm
range 400- 1300rpm
CS65 Slope, defaul DOS, range 1.000 - ---
5.000.
CS66 Cone range, DOS, range 100-300mm ---

CS67 Main saft high position, default DOS, ---


range 3.00 - 20.00mm
CS68 Main shaft low position, default DOS, ---
range 3.00 - 20.00mm
CS69 Crusher minimum setting, with shortest ---
stroke, default 21, range 0.0-50.0mm
CS70 Crusher high adjusting pressure, ---
default DOS, 5.0 - 100 bar
CS71 Crusher high adjusting pressure ---
hysteresis, default 2bar, range 0.1 -
5.0bar
CS72 Crusher Max pressure, default DOS, ---
range 5.0 - 100.0bar

N11450562(6.0)
Created 1.9.2004 by PNi 11/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

CS73 Maximum adjusting pressure ---


hysteresis, default 2 bar, range 1,0 –
5,0 bar
CS74 Crusher Excessive adjusting pressure, ---
default DOS, range 5.0 - 100.0bar

CS75 Crusher high power limit, shortest ---


stroke, default 120, range 0-400kW
CS76 Crusher high power hysteresis, default ---
10kW, 1 - 50kW
CS77 Crusher maximum power limit, ---
shortest stroke, default 135, range 0-
400kW
CS78 ---
Crusher Max power hysteresis,
default 10kW, range 1 - 50kW
CS79 Crusher excessive power limit, ---
shortest stroke, default 150, range 0-
400kW
CS80 Setting sensor signal low-pass cut-off 0,1
frequency, default 1Hz, range 0.1 -
25Hz
CS81 Setting mode, hysteresis, default 0.5, ---
range 0.1 - 5mm
CS82 Setting mode, overload counter in use ---
(1), not in use (0)
CS83 Setting mode, max amount of ---
overloads, default 3, range 1-10
CS84 Setting mode, increase time window ---
for overload counting, default 60sec,
range 10 - 600sec
CS85 Setting mode, decrease time window ---
for overload counting, default 5, 0.5 -
60 min
CS86 Crusher idling pressure limit, default ---
DOS, range 2 - 10bar
CS87 Crusher adjusting pressure signal low- ---
pass cut-off frequency, default 1Hz,
range 0,1 - 25Hz
CS88 Crusher power or drive pressure signal 0,5
CS89 Contact calibration not in use (0), in ---
use (1)
CS90 Contact calibration measurement ---
delay, default 3 sec., range 1 - 10 sec.

CS91 Contact calibration pressure, default 2 ---


bar., range 1 - 10 bar.
CS94 Crusher idling power limit, default ---
DOS, range 5 - 200kW
CS98 Setting sensor, 4mA corresponding ---
main shaft position, default 0, range 0 -
10mm

N11450562(6.0)
Created 1.9.2004 by PNi 12/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

CS99 Setting sensor, 20mA corresponding ---


main shaft position, default 200mm,
range CS66 - 300mm.
CS100 Crusher stroke length, adjustable 0, ---
default 18, step 0.5, range 0.0 – 50.0

CS101 Crusher high power limit, longest ---


stroke, default
CS102 Crusher maximum200,power
range limit,
0-400kW
longest ---
stroke, default 215, range 0-400kW

CS103 Crusher excessive power limit, longest ---


CS104 Crusher stroke measurement ---
signal, 4mA corresponding stroke,
range 10.0-50.0
CS105 Crusher stroke measurement ---
signal, 20mA corresponding stroke,
range 10.0-50.0
CS106 Crusher minimum setting, longest ---
stroke, default 30, range 0.0-50.0mm

CS107 Crusher vibration warning level, default ---


3,0 g, range 1,0-50,0 g

CS108 Crusher average vibration shutdown ---


level, default 3,5 g, range 1,0-50,0 g
CS109 Crusher vibration excessive limit, ---
default 15,0g, range 0-50,0g
CS110 Vibration sensor's signal that ---
corresponds 4mA-value
CS111 Vibration sensor's signal that ---
corresponds 20mA-value
CS112 Vibration sensor g-value for parameter ---
CS110
CS113 Vibration sensor g-value for parameter ---
CS111
CS114 Crusher top bearing warning ---
temperature, default 140°C, range 75-
150°C
CS115 Crusher bottom bearing warning ---
temperature, default 140°C, range 75-
150°C
CS116 Crusher top bearing excessive ---
temperature, default 150°C, range 95-
165°C
CS117 Crusher bottom bearing excessive ---
temperature, default 150°C, range 95-
165°C
CS118 Top bearing temp. sensor 4 mA signal ---
corresponds temperature
CS119 Top bearing temp. sensor 20 mA ---
signal corresponds temperature

N11450562(6.0)
Created 1.9.2004 by PNi 13/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

CS120 Bottom bearing temp. sensor 4 mA ---


signal corresponds temperature
CS121 Bottom bearing temp. sensor 20 mA ---
signal corresponds temperature
CS122 Crusher's safety monitoring in use for ---
vibration (1), for temperatures (2), for
both (3), not in use (0)
CS123 Crusher drive pressure high limit, ---
default 300, range 0 - 400bar
CS124 Crusher drive pressure max limit, ---
default 300, range 0 - 400bar
CS125 Crusher drive pressure excessive limit, ---
default 300, range 0 - 400bar
C126 Crusher drive wake-up pressure ---
C127 Crusher speed value, 0 = rpm, 1 = tip ---
speed
CS128 Crusher power measurement in use ---
(1), not in use (0)
CS129 Power measurement, 4mA ---
corresponding kW-value
CS130 Power measurement, 20mA ---
corresponding kW-value
CS131 Crusher motor’s feedback delay, ---
default 20 sec., range 0 - 90
CS132 Crusher setting devices, none (0), 0
Toggle plate monitoring (1), Hydraulic
setting adjustment (2), Toggle plate
monitoring and Hydraulic setting
adjustment (3), Active seting control
(4)

CS133 Crusher motor max current, default ---


580mA, range CS134-800mA
CS134 Crusher motor min current, default ---
400mA, range 0-CS133
CS135 Crusher motor ramp fastness mA / ---
sec. default 30, range 1-50 mA/sec.
CS136 Crusher motor fine tune ramp fastness ---
mA / sec. default 4, range 1-50
mA/sec.
CS137 Crusher pump fine tune ramp fastness ---
mA / sec. default 4, range 1-50
mA/sec.
CS138 Shortest allowed time between crusher ---
start events, range 0-30min

CS139 Crusher pump swing fastness mA/sec, ---


default 100mA, range. 1-1000mA/sec

CS140 Crusher adjusting pressure maximum ---


force pressure level, default 25 bar,
range 0-100bar

N11450562(6.0)
Created 1.9.2004 by PNi 14/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

CS141 Crusher adjusting pressure release ---


pressure level, default 45 bar, range 0-
100bar
CS142 Crusher peak pressure sample rate, ---
default 200, range 0 -300
CS143 Crusher peak pressure overload level, ---
default 5, range 0 - 100
TRACK DRIVE
T1 Minimum value for right track ---
backward, default 60.0%, range 50.0 -
T2 95.0% value for right track forward,
Minimum ---
default 40.0%, range 5.0 - 50.0%
T3 Minimum value for left track backward, ---
default 60.0%, range 50.0 -95.0%
T4 Minimum value for left track forward, ---
default 40.0%, range 5.0 -50.0%
T5 Fast speed rpm, default 2000, range 2000
1500…2300 (value must be higher
than Normal speed rpm)
T6 Normal speed rpm, default 1500, 1200
range 1000…2000 (value must be
lower than Fast speed rpm AND
higher than Engine MIN speed)
T7 Stop ramp, default 20ms, range 1- 20
200ms
T8 Minimum speed current value for right 32
track backward, default 40.0%, range
0.0 - 100.0%
T9 Minimum speed current value for right 32
track forward, default 40.0%, range 0.0
- 100.0%
T10 Minimum speed current value for left 32
track backward, default 40.0%, range
0.0 - 100.0%
T11 Minimum speed current value for left 32
track forward, default 40.0%, range 0.0
- 100.0%
T12 Tracks acceleration ramp, default 500 200
ms, range 10 - 2000 ms
TS14 Support legs limit switch, “0” = not in 0
use, “1” = in use, default 0, range 0-1

TS15 Proportional valve with current control 1


(1), with PWM control (2), directional
valves (3)
TS16 Main conveyor lifting, not in use '0', in ---
use with lift/drop control '1', in use with
lift/hold control '2'
ENGINE

N11450562(6.0)
Created 1.9.2004 by PNi 15/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

E1 Engine MIN speed, default 850 rpm, 850


range 700 - 1200 rpm (value must be
lower than clutch activation speed - 20
rpm AND lower than T6) (IC7X0 range
800-1200)
ES2 Engine MAX speed, default 2100 rpm, 2100
range 1500 - 2500 rpm (value must be
higher than or equal to parameters
CS52-CS57)
E3 Fuel level alarm limit, default 5 %, 5
range 0 - 20 %
ES4 Fuel level sensor output voltage when 1,25
fuel tank is full, default 1.08 V, range 0 -
5V
ES5 Fuel level sensor output voltage when 0,10
fuel tank is empty, default 0.1 V, range
0-5V
ES8 Cooler temperature control in use. 1
Default 0, range 0”disabled” – 1 “in
use”
ES9 Cooler maximum mA-value (minimum 600
speed), default 600mA, range 400-
750mA
ES10 Cooler minimum mA-value (maximum 30
speed), default 200mA, range 0-
400mA
ES11 Coolant temperature OK limit, default 70
70°C, range 60°C - 85°C
ES12 Coolant temperature HIGH limit, 98
default 98°C, range 86°C - 100°C
ES13 Charge air temp temperature OK limit, 43
default 43°C, range 35°C - 45°C

ES14 Charge air temp temperature HIGH 50


limit, default 50°C, range 46°C - 70°C

ES15 Cooler ramp speed fastness mA / 3,0


sec., default 0,5 range 0.1 – 5.0mA
ES17 Fuel tank capacity, default 520L, ---
range 0 – 1500L
ES18 Engine coolant temperature, feed stop 106
limit, default 106°C, range 0 -130°C, if
set to 0 not in use.
ES19 Engine coolant temperature, process 125
stop limit, default 125°C, range 0 -
ES20 Engine power, default 317kW, range 310
100 - 1000kW.
E21 Engine deration monitoring, 1
in use (1), not in use (0)
ES22 Engine control and monitoring, ---
in use (1), not in use (0)

N11450562(6.0)
Created 1.9.2004 by PNi 16/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

ES23 Engine speed when lubrication oil ---


heating is activated, default 2000 rpm,
range E1-ES2 rpm
ES24 Engine idling power limit, range 0 - 30
ES25%
ES25 Engine excessive power limit, range 100
F99 - 125%
ES26 Engine work revolutions speed limit, 1700
default 1700 rpm, range 1500 – ES2
rpm
E27 Engine process revolutions, default ---
1900 rpm, range 1500 – ES2 rpm
ES28 Diesel particulate filter shoot load 95
percent, feed stop limit, default 95%,
range 50%-ES29
ES29 Diesel particulate filter soot load 98
percent, process stop limit, default
100%, range ES28-150%
ES30 1
Engine type, tier3 ‘1’, tier4 ‘2’, default
1, range 1 - 2

HYDRAULIC SYSTEM

H1 Device pump pressure alarm limit, 200


default 200 bar, range 0-350 bar (if set
to zero, sensor not in use)
HS2 Hydraulic oil temperature sensor ---
gain(mV/100°C), , default 944, range 0-
32767
HS3 Hydraulic oil temperature sensor zero ---
point, (1,50V=150), default 2,11V,
range 0- 32767,
HS4 Hydraulic oil temperature limit for 35
monitoring oil filter, range -50 - +50,
default 20
HS5 Crusher pressure sensor 4 mA value, ---
default 0, range 0- 1000
HS6 Crusher pressure sensor range, ---
default 600, range 0- 1000
HS7 Clamping pressure sensor 4 mA 0
value, default 0, range 0- 1000
HS8 Clamping pressure sensor range, 600
default 600, range 0- 1000
HS9 Device pumps and lifting conveyor 0
pressure sensor 4 mA value, default 0,
range 0- 1000
HS10 Device pumps and lifting conveyor 600
pressure sensor range, default 600,
range 0- 1000
HS11 Toggle pressure sensor 4 mA value, ---
default 0, range 0- 1000

N11450562(6.0)
Created 1.9.2004 by PNi 17/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

HS12 Toggle pressure sensor range, default ---


0, range 0- 1000
H13 Device pump 2 pressure limit, default 260
250bar, range 0 – 350bar (if set to
zero, sensor not in use)
H15 Device pump 3 pressure limit, default 0
0 bar, range 0-350 bar (if set to zero,
sensor not in use)
HS17 Hydraulic oil cooler start temp, default 55
55°C, range 20-80 °C (value must be
higher than cooler stop temp)

HS18 Hydraulic oil cooler stop temp, default 45


45°C, range 30-70 °C (value must be
lower than cooler start temp)
H19 Hydraulic oil cooler automatic cleaning 0
in use (1), not in use (0)
HS20 Hydraulic outlet 2 in use (1), not in use 0
(0)

HS21 Lifting conveyor oil volume flow, ---


default 100, range 0 - 500l/min
HS22 LC-feeder oil volume flow, default 25, ---
range 0 - 500l/min
HS28 Hydraulic pump motor 1 in use (1), not ---
in use (0)
HS29 Hydraulic pump motor 2 in use (1), not ---
in use (0)
HS30 Hydraulic oil cooler fan with hydraulic ---
use (1), with electric use with one fan
(2), with electric use with two fans (3)

HS31 Authorization delay, default 360sek, 30


range 0-1800sek
HS32 Hydraulic oil temperature sensor 0
offset, default 0, range -999 – 999
Ohm (disabled = 999)
LUBRICATION SYSTEM
LS1 Lubrication tank oil temperature ---
sensor 4mA value, default 0°C,
range -30 - 100°C
LS2 Lubrication tank oil temperature ---
sensor range, default 100°C range 0 -
120°C
LS3 Lubrication return oil temperature ---
sensor 4mA value, default 0°C, range -
30 - 100°C
LS4 Lubrication return oil temperature ---
sensor range, default 100°C range 0 -
120°C

N11450562(6.0)
Created 1.9.2004 by PNi 18/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

LS5 Lubrication tank oil heaters, heaters off ---


limit default 30°C range 0 - 100°C

LS6 Lubrication return oil too hot, feed stop ---


limit default 55°C range 0 - 100°C

LS7 Lubrication return oil too hot, crusher ---


alarm limit default 60°C range 0 -
100°C
LS8 Counter shaft pressure alarm delay, ---
default 10-sec, range 1 –10 -sec.

LS9 Lubrication pump low speed limit, ---


default 1400 rpm, range1000 –
1400rpm
LS10 Lubrication oil cooler ON temperature ---
limit. Default 45°C, range 30°C - 60°C

LS11 Lubrication oil cooler OFF temperature ---


limit. Default 35°C, range 20°C - 55°C

LS12 Lubrication pump motor type, “1” ---


=hydraulic motor, “2” =electric motor,
default “0”
LS13 Lubrication tank temp process enabled ---
limit, default 20°C, range 0°C - 30°C

LS14 Lubrication pump running time after ---


crusher has stopped, default 120s,
range 1 –300s
LS15 Lubrication pump speed sensor ---
detected pulses per one round, default
1, range 1-50 default 1, range 1-50

LS16 lubrication oil cooler motor type “1” ---


hydraulic, “2” electric motor, range 1-
2.
LS17 oil heating hydraulic pump ramp time. ---
if set to zero not in use, default 0sec.
range 0, 30 –300sec
LS18 Lubrication pump speed alarm delay, ---
default 10sec. range 0 –30sec

LS19 Temperature sensor signal low-pass ---


cut-off frequency, default 1Hz, range
0.1 - 25Hz
LS20 Return oil temperature, crusher start ---
enable low limit, default 17°C, range
10-30°C
LS21 Return oil temperature, crusher start ---
enable high limit, default 55°C, range
40-65°C

N11450562(6.0)
Created 1.9.2004 by PNi 19/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

LS22 Lubrication oil cooler running time after ---


lubrication pump has stopped, default
20s, range 0 –60s
LS23 Winter mode, pump ON time, default 5 ---
min, range 1 - 15min
LS24 Winter mode, pump OFF time, default ---
10 min, range 1 - 120min
LS25 Winter mode, lubrication return oil ---
excessive low temperature limit,
default 0°C, range -25 - 25°C
LS26 Engine speed when lubrication oil ---
heating is activated, default 850 rpm,
range E1-ES2 rpm
LS27 Lubrication oil heating method, '1' ---
Hydraulic, '2' Electric, '3' Electric with
hydraulic driven generator.
DISTRIBUTION GEARBOX
KS1 Delay before new start attempt is 3
possible, default 3 min, range 0 – 10
min
KS2 Gearbox oil temperature alarm limit, 90
default 90°C, range 80°C – 120°C
K3 Gearbox oil temperature warning limit, 80
default 80°C, range 60°C – 100°C

KS4 Engine rpm at clutch activation, default 900


900, range 900 – 1200 (value must be
higher than Engine MIN speed + 20
rpm)
KS5 Choke time, default 20 sec. range 0 – 30
30 sec. - if set to zero, not in use
KS6 Delay before clutch slip % is checked 1
during crusher start, default 1 sec.,
range 1 – 60 sec.
KS7 Clutch slip % alarm limit, default 5 %, 5
range 1 – 50 %
KS8 Crusher drive axle speed sensor in 1
use (1), not in use (0)
KS9 Clutch low pressure alarm limit, default 13
13 bar, range 0 – 16 bar
KS10 Gearbox oil temperature sensor 4mA -50
value, default -50 °C, range -50 – 20
°C
KS11 Gearbox oil temperature sensor range, 230
default 250 °C, range 0 – 250 °C, - if
set to zero, not in use
KS12 Clutch pressure sensor 4mA value, 0
default 0 bar, range 0 – 50 bar
KS13 Clutch pressure sensor range, default 100
100 bar, range 0 – 600 bar, - if set to
zero, not in use

N11450562(6.0)
Created 1.9.2004 by PNi 20/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

KS14 Crusher drive axle speed sensor 2


detected pulses per one round, default
2, range 1 – 50
KS15 Delay for clutch slip % alarm when 1
gearbox is running, default 1 sec.,
range 0 - 10 sec.
KS16 Gearbox oil low temperature limit, ---
default 0°C, range -50°C – 50°C
KS17 Crusher drive shaft wheel / Crusher 5,62
wheel ratio, default 1.8, range 0.01 - 5.

KS18 Crusher acceleration time, default 155 0


sec, range 0 – 300 sec. if set 0 not in
use
KS19 Drive axel rpm for choke deactivation, 220
default 220, range 0-600 rpm

KS20 Gearbox gear ratio, default 1.271, 1.271


range 0.500-2.000
SCREEN MODULE
S1 Screen speed sensor in use (1), not in 0
use (0), default 0
S2 FREE ---
S3 Screen left side conveyor in use (1), 0
not in use (0), default 0
S4 FREE ---
S5 Screen right side conveyor in use (1), 0
not in use (0), default 0
S6 FREE ---
S7 Screen return conveyor in use (1), not 0
in use (0), default 0
S8 FREE ---
SS9 Default control value for screen under 670
size conveyor, default 670 mA, range
500 - 800 Ma
SS10 Default control value for screen side 720
conveyors, default 720 mA, range 500 -
800 mA
SS11 Screen forward direction control 680
current at minimum speed, default 680
mA, range 500 - 800 mA
SS12 Screen forward direction control 680
current at maximum speed, default
680 mA, range 500 - 800 mA
S13 Screen module conveyors belt roller 108
diameter, default 108mm, range 50-
200mm.
S14 Screen module undersize conveyor 0
low speed limit, default 1,2m/s, range
0 - 4,0m/s.
S15 Screen left side conveyor speed 0
low limit, default 1,2m/s, range 0 -
4,0m/s.

N11450562(6.0)
Created 1.9.2004 by PNi 21/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

S16 Screen right side conveyor speed 0


low limit, default 1,2m/s, range 0 -
SS17 4,0m/s. reverse direction control
Screen 680
current at MIN speed, default 680 mA,
range 500 - 800 mA
SS18 Screen reverse direction control 680
current at MAX speed, default 680 mA,
range 500 - 800 mA
S19 Screen return conveyor speed low 0
limit, default 1,2m/s, range 0 - 4,0m/s.

LINK CONVEYORS
Delay between starting link conveyors, ---
R1 default 5 s, range 0-30s
Delay between stopping/pausing link ---
R2 conveyors, default 5 s, range 0-30s
---
R3 Work lights switch ON time, default 19
Work lights switch OFF time, default ---
R4 08
Link conveyor 1, not in use “0”, ---
conveyor in use “1”, conveyor and
R10 vibrati
Link conveyor start alarm time, default ---
RS11 5sec, range 3-30sec
Link conveyor start alarm wait time, ---
RS12 default 5sec, range 1-60sec.
Link conveyor 1 Field conveyor ---
interlocking connection, not in use “0”,
R13 in
Link conveyor 1 level sensor, not in ---
R14 use “0”, in use “1”
Link conveyor 1 silo reduction level, ---
R15 default 50%, range 0%-R23
Link conveyor 1 silo high level, default ---
R16 75%, range R22%-R24%
Link conveyor 1 silo excessive level, ---
R17 default 100%, range R23-100%
Link conveyor 1 silo material level ---
hysteresis, default 5%, range 1%-
R18 100%
Ultrasonic level sensor 1 signal’s low- ---
R19 pass cut-off frequency, default 0.1
Link conveyor 1 low speed limit, ---
R20 default 1,2m/s, range 0 - 4m/s
---
Stop delay time, if Link conveyor 1
R21 speed is low, default 10 sec., range 0
Link conveyor 1 belt roller diameter, ---
R22 default 108mm, range 50-200mm
Silo 1 level sensor 0% mA-value, ---
R23 default 18mA, range 4 – 20 mA

N11450562(6.0)
Created 1.9.2004 by PNi 22/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

Silo 1 level sensor 100% mA-value, ---


R24 default 4mA, range 4 – 20 mA
Link conveyor 2, not in use “0”, ---
conveyor in use “1”, conveyor and
RS30 vibrati
Link conveyor start alarm time, default ---
RS31 5sec, range 3-30sec
Link conveyor start alarm wait time, ---
RS32 default 5sec, range 1-60sec.
Link conveyor 2 Field conveyor ---
interlocking connection, not in use “0”,
R33 in
Link conveyor 2 level sensor, not in ---
R34 use “0”, in use “1”
Link conveyor 2 silo reduction level, ---
R35 default 50%, range 0%-R33
Link conveyor 2 silo high level, default ---
R36 75%, range R32%-R34%
Link conveyor 2 silo excessive level, ---
R37 default 100%, range R33-100%
Link conveyor 2 silo material level ---
hysteresis, default 5%, range 1%-
R38 100%
Ultrasonic level sensor 2 signal’s low- ---
R39 pass cut-off frequency, default 0.1
Link conveyor 2 low speed limit, ---
R40 default 1,2m/s, range 0 - 4m/s
---
Stop delay time, if Link conveyor 2
R41 speed is low, default 10 sec., range 0
Link conveyor 2 belt roller diameter, ---
R42 default 108mm, range 50-200mm
Silo 2 level sensor 0% mA-value, ---
R43 default 18mA, range 4 – 20 mA
Silo 2 level sensor 100% mA-value, ---
R44 default 4mA, range 4 – 20 mA
Link conveyor 3, not in use “0”, ---
conveyor in use “1”, conveyor and
R50 vibrati
Link conveyor start alarm time, default ---
RS51 5sec, range 3-30sec
Link conveyor start alarm wait time, ---
RS52 default 5sec, range 1-60sec.
Link conveyor 3 Field conveyor ---
interlocking connection, not in use “0”,
R53 in
Link conveyor 3 level sensor, not in ---
R54 use “0”, in use “1”
Link conveyor 3 silo reduction level, ---
R55 default 50%, range 0%-R43
Link conveyor 3 silo high level, default ---
R56 75%, range R42%-R44%

N11450562(6.0)
Created 1.9.2004 by PNi 23/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020
LT3054
IC730

Link conveyor 3 silo excessive level, ---


R57 default 100%, range R43-100%
Link conveyor 3 silo material level ---
hysteresis, default 5%, range 1%-
R58 100%
Ultrasonic level sensor 3 signal’s low- ---
R59 pass cut-off frequency, default 0.1
Link conveyor 3 low speed limit, ---
R60 default 1,2m/s, range 0 - 4m/s
---
Stop delay time, if Link conveyor 3
R61 speed is low, default 10 sec., range 0
Link conveyor 3 belt roller diameter, ---
R62 default 108mm, range 50-200mm
Silo 3 level sensor 0% mA-value, ---
R63 default 18mA, range 4 – 20 mA
Silo 3level sensor 100% mA-value, ---
R64 default 4mA, range 4 – 20 mA

N11450562(6.0)
Created 1.9.2004 by PNi 24/24
METSO MINERALS OY Revised 05.04.2011 by TKT 03/07/2020