0% found this document useful (0 votes)
10 views2 pages

Moto

The document provides installation instructions for the PC5200 power supply module, detailing the Keybus connection and jumper settings for configuration. It supports up to 1.0A additional current for the PC5020 control panel and includes specifications for battery and transformer requirements. A limited warranty is also outlined, covering defects in materials and workmanship for 12 months from the purchase date.

Uploaded by

mario marra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views2 pages

Moto

The document provides installation instructions for the PC5200 power supply module, detailing the Keybus connection and jumper settings for configuration. It supports up to 1.0A additional current for the PC5020 control panel and includes specifications for battery and transformer requirements. A limited warranty is also outlined, covering defects in materials and workmanship for 12 months from the purchase date.

Uploaded by

mario marra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Keybus

Keybus- The 4-wire Keybus connection is used by the panel to communicate with
Installation Instructions
the module. Connect the RED, BLK, YEL and GRN terminals to the RED, BLK, YEL
and GRN Keybus terminals on the PC5020 control panel. The PC5200 can be used to provide up to 1.0A of additional current to the PC5020
control panel (see PC5020 Installation Manual for complete installation instructions).
PC5200 Jumper Settings The PC5020 v3.1 or higher supports up to four PC5200 modules.
The PC5200 has 2 jumpers; to select which PC5200 slot is to be used refer to Specifications Table 1
the table below.
Table 2 Res i d en t i al Co mmerc i al
PC5200 Current Draw
SLOT J1 J2 20mA
B u rg l ar y Fi r e B u rg l ar y Fi r e

Max. Aux Current Draw


PC5200 1 OFF OFF @12VDC
1A 550mA 1A 550mA

PC5200 2 ON OFF Transformer


16V, 40VA 16V, 40VA 16V, 40VA 16.5V, 37VA
Requirements
PC5200 3 OFF ON 14Ah min
Battery Requirements 7Ah min 7Ah min 14Ah min (2x7Ah)
(2x7Ah)
PC5200 4 ON ON
PC5003C
CMC-1 PC4050CRAR
UL Listed Enclosures PC500C (Household Fire
PC4050CAR (Commercial fire &
& Burglary)
Limited Warranty burglary)
Digital Security Controls Ltd. warrants that for a period of 12 months from the date of purchase, the product Standby Time (min.) 4hours 24hours 4hours 24hours
shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of
such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment Compatible Panel - PC5020
upon return of the equipment to its factory. This warranty applies only to defects in parts and workmanship
and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital
Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage
Terminal Descriptions
arising out of abuse, alteration or improper application of the equipment. NOTE: Devices that require
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other power from the PC5200 shall
warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security be UL Listed for the intended
Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither assumes application and operate over
responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this the range 11.5 - 12.5VDC.
warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct or indirect or consequential damages, loss
Residential
of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, Burglary
installation or operation or failure of this product.
WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a
regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical
disruption, it is possible for this product to fail to perform as expected.

FCC COMPLIANCE STATEMENT


CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could For battery requirements and
void your authority to use this equipment. standby time refer to Table 1.
Recommended Battery:
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the DSC model BD7-12
manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply TRANSFORMER AUX**
with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed 16.5VAC / 37VA FTC Frost
16VAC / 40VA PTD 1640
to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Re-orient the receiving antenna
AC - Supervised, the PC5200 requires a 16.5V/37VA or 16V/40VA transformer.
• Relocate the alarm control with respect to the receiver Connect primary of the transformer to an unswitched AC source (maximum current
• Move the alarm control away from the receiver draw 0.5A) and connect the secondary of the transformer to these terminals.
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
AUX+ - This terminal is used to provide power for expansion modules & devices.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user Please refer to Table 1 for maximum rating.
may find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television Interference
Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4. TAM - This can be used to tamper the cabinet in which the PC5200 is mounted.
Connect a normally closed (NC) switch across TAM and BLK. If the tamper is not being
used connect a piece of wire across TAM and BLK to secure the tamper, this
prevents a trouble condition from occurring.

©2002 Digital Security Controls Ltd. Direct all comments concerning this
Toronto, Canada • www.dsc.com publication to pubs@dscltd.com
Technical Support: 1-800-387-3630
Printed in Canada 29005251 R004
PC52OO v2.O
Power Supply Module
Keybus
Keybus- The 4-wire Keybus connection is used by the panel to communicate with
Installation Instructions
the module. Connect the RED, BLK, YEL and GRN terminals to the RED, BLK, YEL
and GRN Keybus terminals on the PC5020 control panel. The PC5200 can be used to provide up to 1.0A of additional current to the PC5020
control panel (see PC5020 Installation Manual for complete installation instructions).
PC5200 Jumper Settings The PC5020 v3.1 or higher supports up to four PC5200 modules.
The PC5200 has 2 jumpers; to select which PC5200 slot is to be used refer to Specifications Table 1
the table below.
Table 2 Res i d en t i al Co mmerc i al
PC5200 Current Draw
SLOT J1 J2 20mA
B u rg l ar y Fi r e B u rg l ar y Fi r e

Max. Aux Current Draw


PC5200 1 OFF OFF @12VDC
1A 550mA 1A 550mA

PC5200 2 ON OFF Transformer


16V, 40VA 16V, 40VA 16V, 40VA 16.5V, 37VA
Requirements
PC5200 3 OFF ON 14Ah min
Battery Requirements 7Ah min 7Ah min 14Ah min (2x7Ah)
(2x7Ah)
PC5200 4 ON ON PC4050CR
PC5003C
CMC-1 PC4050CRAR
UL Listed Enclosures PC500C (Household Fire
PC4050CAR (Commercial fire &
& Burglary)
Limited Warranty burglary)
Digital Security Controls Ltd. warrants that for a period of 12 months from the date of purchase, the product Standby Time (min.) 4hours 24hours 4hours 24hours
shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of
such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment Compatible Panel - PC5020
upon return of the equipment to its factory. This warranty applies only to defects in parts and workmanship
and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital
Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage
Terminal Descriptions
arising out of abuse, alteration or improper application of the equipment. NOTE: Devices that require
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other power from the PC5200 shall
warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security be UL Listed for the intended
Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither assumes application and operate over
responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this the range 11.5 - 12.5VDC.
warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct or indirect or consequential damages, loss
Residential
of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, Burglary
installation or operation or failure of this product.
WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a
regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical
disruption, it is possible for this product to fail to perform as expected.

FCC COMPLIANCE STATEMENT


CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this
For battery requirements and
equipment. standby time refer to Table 1.
Recommended Battery:
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s DSC model BD7-12
instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B AUX**
TRANSFORMER
device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection 16.5VAC / 37VA FTC Frost
16VAC / 40VA PTD 1640
against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
AC - Supervised, the PC5200 requires a 16.5V/37VA or 16V/40VA transformer.
• Move the alarm control away from the receiver Connect primary of the transformer to an unswitched AC source (maximum current
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. draw 0.5A) and connect the secondary of the transformer to these terminals.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may AUX+ - This terminal is used to provide power for expansion modules & devices.
find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television Interference Problems”. This Please refer to Table 1 for maximum rating.
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4.
TAM - This can be used to tamper the cabinet in which the PC5200 is mounted.
Connect a normally closed (NC) switch across TAM and BLK. If the tamper is not being
used connect a piece of wire across TAM and BLK to secure the tamper, this
prevents a trouble condition from occurring.