0% found this document useful (0 votes)
16 views6 pages

AB06050 Hardware Worksheet 3

The document provides a worksheet for ensuring the AccuLoad III-S or N4 hardware has sufficient I/O for various applications, detailing the required pulse, analog, and digital inputs and outputs. It includes specifications for controlling multiple arms and products in blending applications, as well as guidelines for optional AICB board installations. Revisions and contact information for support are also included, emphasizing the importance of verifying specifications with the manufacturer.

Uploaded by

Andres Orozco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views6 pages

AB06050 Hardware Worksheet 3

The document provides a worksheet for ensuring the AccuLoad III-S or N4 hardware has sufficient I/O for various applications, detailing the required pulse, analog, and digital inputs and outputs. It includes specifications for controlling multiple arms and products in blending applications, as well as guidelines for optional AICB board installations. Revisions and contact information for support are also included, emphasizing the importance of verifying specifications with the manufacturer.

Uploaded by

Andres Orozco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Electronic Preset Delivery System

Smith Meter AccuLoad III


AccuLoad III-S and N4 Hardware Worksheet
Issue/Rev. 0.2 (9/07) Bulletin AB06050

This worksheet is being provided to ensure that the AccuLoad III-S or N4 hardware contains enough I/O for the
application. This sheet should be filled out for every application. The AccuLoad III-S and N4 hardware is capable
of controlling one or two arms in straight arm loading applications, and up to six products per arm in sequential
blending and/or ratio blending applications. When configured for ratio blending, the AccuLoad III-S and N4 are
capable of controlling three product streams (6 product streams: Rev 10.08 and above). Contact your local Smith
representative if you have any questions about this worksheet.

Pulse Inputs Circle Number Required


Product Meter Pulses 1 2 3 4 5 6 (For dual pulse meters,
2 per meter )
Density 1 2 3
Additive Meter 1 2 3 4
Flow Controlled Addi- 1 2 3 4 For dual pulse meters, 2
tive Meter per meter)

Total 6 or less

Note: AICB boards can be added to provide additional pulse inputs for additive meters. The AICB board adds 10 additional additive meter in-
puts. For the AccuLoad III-N4 hardware, the AICB board must be mounted in a remote housing. . Flow Controlled Additives must be wired to
the PIB board.

Analog Inputs Circle Number Required


RTD (Temperature) 1 2 3 4 5 6
4-20 mA (Temperature, Density, Pressure, 1 2 3 4 5 6
General)
1-5 Vdc (Temperature, Density, Pressure, Gen- 1 2 3 4 5 6
eral)
Analog Outputs
4-20 mA (Valve Control, Flow Rate, General) 1 2 3 4 5 6
1-5 Vdc (Valve Control, Flow Rate, General) 1 2 3 4 5 6
Total Analog Inputs and Outputs 6 or less

The Most Trusted Name In Measurement


AC Digital Inputs Circle Number Required
Security 1 2
Arm Permissive (Maximum 2 per arm) 1 2 3 4
Second High Flow Rate (1 per arm) 1 2
Remote Start Arm 1 2
Remote Stop 1
Remote Stop Arm 1 2
Transaction Reset (1 per arm) 1 2
General Purpose 1 2 3 4 5
Print Tray Switch 1 2
Block Valve Feedback 1 2 3 4 5
Piston Injector Feedback 1 2 3 4 5
System Permissive 1 2 3
Swing Arm Side A 1 2
Swing Arm Side B 1 2
DE Head Stop Flow 1 2
DE Head Low Flow 1 2
DE Head High Flow 1 2
Bay A Permissive 1 2
Bay B Permissive 1 2
Meter Injector Prove 1
Total 5 or less

2 AB06050 Issue/Rev. 0.2 (9/07)


DC Digital Inputs Circle Number Required
Security 1 2

Arm Permissive 1 2 3 4
(Maximum 2 per arm)
Second High Flow Rate (1 per arm) 1 2

Remote Start Arm 1 2

Remote Stop 1

Remote Stop Arm 1 2

Transaction Reset (1 per arm) 1 2

General Purpose 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Print Tray Switch (1 per arm) 1 2

Block Valve Feedback 1 2 3 4 5 6 7 8 9 10 11 12

Piston Injector Feedback 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

System Permissive 1 2 3

Swing Arm Side A 1 2


Swing Arm Side B 1 2
DE Head Stop Flow 1 2
DE Head Low Flow 1 2
DE Head High Flow 1 2
Bay A Permissive 1 2
Bay B Permissive 1 2
Meter Injector Prove 1
Total 6 or less Standard
16 or less with optional AICB board
(AccuLoad III-N4 AICB board must be mounted in a remote housing)

AB06050 Issue/Rev. 0.2 (9/07) 3


AC Digital Outputs Circle Number Required
Product Pumps
1 2 3 4 5 6
(Sequential Blending, 1 per arm)
Upstream Solenoids 2 1 2 3 4 5 6
2
Downstream Solenoids 1 2 3 4 5 6
Alarm Relay 1 2
General Purpose 1 2 3 4 5 6 7 8 9 10 Æ 51
Block Valve 1 2 3 4 5 6 7 8 9 10 11 12
Stop Relay (1 per arm) 1 2
Additive Pumps 1
1 2 3 4 5 6 7 8 9 10 Æ 24
Piston Injectors 1 2 3 4 5 6 7 8 9 10 Æ 24
1
Metered Injectors (Solenoids) 1 2 3 4
Shared Additive Solenoids 1 2 3 4 5 6 7 8 9 10 11
Shared Additive Flush 1 2 3 4
Flow Controlled Additive Upstream
1 2 3 4
Solenoid 2
Flow Controlled Additive Down-
1 2 3 4
stream Solenoid 2
Total 11 or less Standard
31 or less with optional AICB board
51 or less with optional 2nd AICB board
(AccuLoad III-N4 AICB board must be mounted in a remote housing)

1 Additive pumps and solenoid outputs are fixed on the AICB when more than 4 metered additives are programmed. It is recommended that if
the AICB board is required for additional metered additives, that all additives be connected to the AICB board.
2 Upstream and downstream solenoids should be programmed and wired on EAAI AccuLoad board.

4 AB06050 Issue/Rev. 0.2 (9/07)


DC Digital Outputs Circle Number Required
Product Pumps 1 2 3
(Sequential Blending, 1 per arm)
Upstream Solenoids 2 1 2 3
2
Downstream Solenoids 1 2 3
Alarm Relay 1 2
General Purpose 1 2 3
Block Valve 1 2 3
Stop Relay (1 per arm) 1 2
Additive Pumps 3 1 2 3
Piston Injectors 1 2 3
3
Metered Injectors (Solenoids) 1 2 3
Shared Additive Solenoids 1 2 3
Shared Additive Flush 1 2 3
Flow Controlled Additive Upstream 1 2 3
Solenoid 2
Flow Controlled Additive Down- 1 2 3
stream Solenoid 2
Total 3 or less

2 Upstream and downstream solenoids should be programmed and wired on EAAI AccuLoad board.
3 Additive pumps and solenoid outputs are fixed on the AICB when more than 4 metered additives are programmed.

AB06050 Issue/Rev. 0.2 (9/07) 5


AccuLoad III-S Model Number (Refer to Specification Sheet SS06036)

ALIII-S-XP - - A XXXXX - X

ALX1 Digit 1: # of RTDs A – AICB Board


ALX2 Digit 2: # of 4-20 mA inputs
Digit 3: # of 4-20 mA outputs
Digit 4: # of 1-5 Vdc inputs
Digit 5: # of 1-5 Vdc outputs

The optional AICB can be mounted inside the AccuLoadIII® or in a remote enclosure. It is recommended that it be
mounted at or near the additive injector panel to save on wiring costs. All that is needed back to the AccuLoad III
is +24 Vdc power and a communication cable. Consideration should be given to mounting the AICB in the remote
housing any time the additive panel is a considerable distance away from the AccuLoad. The cost of running +24
Vdc power and one communication wire versus the remote housing and all the additive wiring should be consid-
ered.

AccuLoad III-N4 Model Number (Refer to Specification Sheet SS06041)


ALIII-N4 - - - - 0 - A XXXXX -

ALX1 0 0 0 Digit 1: # of RTDs 0 – 10 (fuse holders)


ALX2 1* 1** 1*** Digit 2: # of 4-20 mA inputs
2 Digit 3: # of 4-20 mA outputs
Digit 4: # of 1-5 Vdc inputs
Digit 5: # of 1-5 Vdc outputs

* Stop Button. 0 = None; 1 = 120/230 Volts AC


** Indicator Lights. 0 = None; 1 = 120 Volts AC

***Hardware Options. 0 = None; 1 = Card Reader; 2 = Captive Card Reader

The AccuLoad III-N4 hardware can be used in conjunction with the AICB board, but these additional boards must
be mounted in remote housing and +24 Vdc power and a communication wire run between the AccuLoad and the
remote boards.

If your application exceeds the number of I/O points available on the AccuLoad III-S or N4 hardware, refer to the
worksheet for the AccuLoad III-Q hardware (AB06049) or the AccuLoad III-SA hardware (AB06068). It may be a
better fit for your application.

Revisions included in AB06050 Issue/Rev.0.2 (9/07):


Page 1: Added 6 product streams to opening paragraph, omitted #3 in density field on pulse inputs chart
Page 2: Omitted #2 in meter injector prove field on AC digital inputs chart
Page 3: Omitted #2 in meter injector prove field on DC digital inputs chart
Page 4: Added through 51 in general purpose field, through 24 in additive pumps and meter injectors fields, omitted #’s 12, 13, and 14 in
shared additive field, added note in total field
Page 5: Omitted note in total field
Page 6: Edited first paragraph

The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are cur-
rently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

Headquarters:
1803 Gears Road, Houston, TX 77067 USA, Phone: 281/260-2190, Fax: 281/260-2191

Gas Measurement Products: Liquid Measurement Products: Moscow, Russia Phone (7) 495/564-8705
Erie, PA USA Phone 814/898-5000 Erie, PA USA Phone 814/898-5000 Melbourne, Australia Phone (61) 3/9807-2818
Thetford, England Phone (44) 1842-82-2900 Los Angeles, CA USA Phone 310/328-1236 Beijing, China Phone (86) 10/6500-2251
Kongsberg, Norway Phone (47) 32/286-700 Slough, England Phone (44) 1753-57-1515 Singapore Phone (65) 6861-3011
Buenos Aires, Argentina Phone 54 (11) 4312-4736 Ellerbek, Germany Phone (49) 4101-3040 Chennai, India Phone (91) 44/450-4400
Barcelona, Spain Phone (34) 93/201-0989
Integrated Measurement Systems:
Corpus Christi, TX USA Phone 361/289-3400
Kongsberg, Norway Phone (47) 32/286-700
San Juan, Puerto Rico Phone 787/274-3760
United Arab Emirates, Dubai Phone 971 +4/331-3646

Visit our Web site at www.fmctechnologies.com

Printed in U.S.A. © 4/05 FMC Technologies Measurement Solutions, Inc. All rights reserved. AB06050 Issue/Rev. 0.2 (9/07)