VRF Catalog 2022 Eng
VRF Catalog 2022 Eng
–
Welcome
to Hitachi
Cooling & Heating
–
4
ddle East
China & Asia
9
Japan
3
1
India
2
1
VRF
VRF
- First dual-service heat pump.
2015 - VRF Eurovent-certified range.
1
Prioritize energy efficiency and
2
Reduce the carbon impact of
3
Keep dwellings cool in high
energy decarbonization. building construction. outside temperatures.
RE 2020 IN A NUTSHELL
ot meet RE 2020
available at:
pep-ecopassport.org
or inies.fr
- COP up to 3.3.
outside without electrical
- Keymark-certified.
resistance.
- Centralized production.
- Option of collective pairing of
apartment thermal modules
VRF
(Title V).
VRF SIGMA
VRF
Our wide range of Hitachi VRFs is ideal for small and large
12
VRF
oudort units
Capacity range in cooling mode (hp)
3 4 5 6 8 10 12 14 16 18 20 22 24 >24
p. 22
p. 28
VRF
Max number of IU connected: 64
• Refrigerant R410A (8 - 96 hp)
- - - - • • • • • • • • • •
p. 38
p. 46
- • • • • • - - - - - - - -
p. 58
* JOHNSON CONTROLS - HITACHI AIR CONDITIONING EUROPE SAS participates in the Eurovent Certification Program for AC/VRF/LCP-HP categories; data from certified models are listed in the Eurovent Annual Report
(www.eurovent-certification.com).
Technical features
14
VRF system
Micro VRF
(Utopia Prime & IVX Prime) VRF 2 tubes 400V / 3 / 50Hz
Refrigerant R32 (4 - 6 hp) 90 - 115 %
(reversible) and 230V / 1 / 50Hz (acc. to 4
Refrigerant R410A (3 -12 hp) acc. to applications
& Single Split model)
Micro VRF
(IVX Prime and Utopia Prime)
- IVX Prime range 4 to 6 hp to R32 or R410A.
- Utopia Prime R410A: available from 3 hp
to 12 hp.
- Option to manage up to 4 indoor units
independently.
- Compact and lightweight units.
- Ideal for these applications: residential and
small public.
- Available pressure: 30 Pa (IVX Prime).
IU
Min. power of connected indoor Max. pipe length Max drop between OU - IU Max. drop between indoor Operating ranges
units (OU above/below) units (ext. temp) +100
models
Heating mode
-20° ~ 18°C WB
0.8 hp
50 to 100 m 30 m/20 m 3m
(2 kW cooling) Cooling mode
-5°C ~ 46°C DB
(-15°C : option)
Cassettes
Heating mode
-20° ~ 15°C WB
0.4 hp 50 m/40 m
85 to 125 m 15 m
(1.1 kW cooling) (acc to model) Duct
Cooling mode
-5° ~ 48°C DB
Heating mode
Wall unit
-20° ~ 15°C WB
0.4 hp
165 m 50 m/40 m 30 m
(1.1 kW cooling)
Cooling mode
-10° ~ 48°C DB
Console
Heating mode
-20° ~ 15°C WB
0.4 hp
165 m 50 m/40 m 30 m
(1.1 kW cooling)
Cooling mode
-10° ~ 52°C DB Ceiling unit
Heating mode
-15° ~ 15°C WB
0.8 hp 75 to 100 m
30 m/20 m 10 m
(2 kW cooling) (acc to model)
Cooling mode
-5° ~ 46°C DB Hydraulic module
VRF
- Available from 14 to 268 kW.
- Reversible and heat recovery VRF solution.
- Standard and High efficiency ranges.
- Space and cost savings
(single module up to 67 kW).
- Exclusive comfort: "GENTLE COOL" and
"smooth drive control” function.
- Available pressure: 80 Pa.
- Perfect for medium and large-scale public
applications.
* Please refer to the technical documentation for more details on the combinations allowed.
–
16
Service Access
The access hatch to the electrical box panel simplifies service
and maintenance. It offers access to the PCB1 without having
HP pressure switch
to completely open the electrical box.
Electrical box
panel
The following activities can be carried out from the access
hatch: Access hatch
VRF SIGMA 5 to 96 hp
3-In-1 solution: heating, air conditioning and heat recovery
Hitachi + Plus benefits
- 2T/3T application on the same unit.
- Single module Sizes 5, 6 and 24 hp “exclusive”.
- Improved comfort: an IU starts up (min. 1.1kW), the OU starts up.
2 pipes
Heat pump CH box with single
output
Sigma or Set free mini solution with a single or multi-output box for all indoor units
VRF
except one connected upstream and operating in cooling mode only which avoids
adding a single-split for the service room.
Unique and exclusive solution on the market. Unbeatable in terms of price positioning.
Refrigerant connection
to the server room IU (all
CH box with multi-outputs year round cooling).
Outdoor unit
CH box
Suction HP pressure
switch
BP
Return flow
VRF
Oil level pipe
HP
27
Control capacity of
40
25 Cooling capacity = 7.88 kW
24 % Power input = 1.13kW
EER = 6.96
23 energy
savings
22
10% 21
20 Min
Max. Cooling load Min.
0.0 20.0 40.0 60.0 80.0 100.0 120.0
savings
Evaporation temperature (°C)
24
22
20
18
16
14 Load 30% 14°C
12 Load 45% 12°C
10 Load 60% 10°C
8 Load 75% 8°C
4
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 900 960
Time passed (mm)
The + points of the Hitachi solution Heating Defrosting Heating Defrosting Heating
(4h) (3~9mn) (4h) (3~9mn) (4h)
- Runs for up to 4 hours without defrosting!
- Defrosting time limited to 3 to 9 min to maintain comfort.
Ambient temperature
- Fan stops during defrosting, then blower when the T°s > 30°C More comfort
(user comfort maintained).
- Maintains the lower part of the external exchanger at
temperatures between 5°C and 20°C. No draft No draft
(fan stop) (fan stop)
VRF
Three-layer anti-corrosion treatment
3 coating layers
3 - Epoxy resin layer
2 - Waterproof film layer
1 - Lubricant layer
Aluminum
Lubricant layer
Waterproof film layer
Epoxy resin layer
Micro VRF
(Utopia Prime & IVX Prime)
1 2
The smallest VRF on the market, Pressure available 30 Pa on IVX
from the widest range of its Prime and flexible installation
class. options
30 Pa
3
Simultaneous or independently
control of indoor units
Depending on the direction they are facing, many buildings may have a different thermal load in each zone. In this case:
- Setting setpoint temperatures individually is useful
- Individual control is an ideal solution for small and medium public applications
23
4 5
A wide choice of indoor units Less piping, more savings
6
Even greater flexibility
VRF
1st stage T = 20°C
Up to
100 m 3m
Max. drop
30 m
T = 21°C T = 24°C
In the same building, the requirements in terms of - Up to a total of 100 m refrigerant length,
aesthetics, space, and temperature are different in each - 30 m drop between IU and OU (OU above),
room. So it fits into any space, the Micro VRF range is 20 m if the OU below,
compatible with all SYSTEM FREE indoor units: Wall, - Installation of indoor units on different floors connected
Ducted, Cassette, Console and Ceiling. to the same refrigerant line.
–
24
Utopia Prime
Utopia Prime
Twin and VRF shared indoor unit groups Renewed master-slave control for more
The UTOPIA PRIME range comes with all the advantages of VRF indoor units,
so you can make use of a wide range of combinations.
energy savings
Different types of indoor units can be mixed on the same installation. The outdoor unit will start up only if the 4 indoor units need cooling or
heating. The shutdown of the group is triggered as soon as one of the indoor
units is no longer requires heat/cooling, which promises real energy savings.
Flexible installation
UNIQUE! The new range of 4 to 6Hp can come in TWIN, TRIPLE, or QUAD
configurations for R32 and R410A and has a static pressure of 30Pa. This
allows the air to be recirculated. Connect up to 4 indoor units in the Set free
range (size 0.8Hp Mini compatible; console units not compatible).
Example
Advanced anti-corrosion treatment installation
With its triple handling, Utopia Prime offers the best protection on the market
for use in tough environments.
20°C
20°C
1 single
Remote control 20°C 20°C
-20°C Heating
Heating 15°C18°C
-20°C
-20°C -10°C
-10°C -10°C
-10°C 0°C
0°C 10°C
10°C 20°C
20°C 30°C
30°C 40°C
40°C 50°C
50°C
Outdoor units
1.140
629
300 370
898 950
RAS-3HVRC2 RAS-4H(V)RC2E
RAS-5H(V)RC2E
RAS-6H(V)RC2E
RAS-4H(V)NC2E
RAS-5H(V)NC2E
RAS-6H(V)NC2E
Utopia Prime 25
Preliminary data
R32 refrigerant R410A refrigerant
Performance, cooling Unit 3Hp 4Hp 5Hp 6Hp 4Hp 5Hp 6Hp
Rated power cooling kW 7.1 10.00 11.90 14.00 10.00 11.90 14.00
Rated power input cooling kW 2.26 2.70 3.71 4.29 2.70 3.71 4.29
EER (1*)
- 3.14 3.70 3.37 3.26 3.70 3.37 3.26
SEER (average climate) - 6 6.57(V) - 6.41 6.1(V) - 6.06 5.88(V) - 5.85 6.57(V) - 6.41 6.1(V) - 6.06 5.88(V) - 5.85
Operating ranges in cooling mode* - -15°C / +46°C (DB) -15°C / +46°C (DB)
Performance, heating
Rated power input heating kW 2.00 2.45 3.60 3.78 2.45 3.60 3.78
Technical features
Airflow (cooling) m3/h 2982 4800 4800 4800 4800 4800 4800
Noise level in cooling mode (night-time dB(A) 48 (46) 52 (50) 53 (50) 55 (53) 52 (50) 54 (53) 55 (53)
pressure)(1)
Sound pressure dB(A) 66 68 69 71 68 69 71
Net weight kg 48 84 84
Dimensions (H x L x D) mm 629 x 898 x 300 1140 x 950 x 370 1140 x 950 x 370
Capacity ratio (min - max) % 90% - 100% 90% - 115% 90% - 115%
Cooling properties
Prefilled for m 20 30 30
Min. length m 5 5 5
VRF
Max. level difference (outdoor unit above m 30 / 20 30 / 20 30 / 20
/ below)
Diameter of pipes (Liq / Gas) mm 9.52 (3/8) - 15.88 (5/8) 9.52 (3/8) - 15.88 (5/8)
inches
Coolant - R32 R410A
Power supply - 1~ 230V 50Hz 1~ 230V 50Hz or 3N~ 400V 50Hz 1~ 230V 50Hz or 3N~ 400V 50Hz
Cable width (EN 60 335-1)* mm² 3 x 4.00 3 x 6.00 or 5 x 4.00 3 x 6.00 or 5 x 4.00
H-LINK
Micro VRF
(Utopia Prime & IVX Prime)
THE FIRST
VRF Hitachi
to R32
(4~6HP)
Outdoor units
1.650
1.380
600 1.140
RAS-4H(V)NP2E
RAS-5H(V)NP2E RAS-8HNCE
RAS-3HVNC1 RAS-6H(V)NP2E RAS-10HNCE RAS-12HNC
Micro Utopia Prime 27
Performance, cooling
Capacity, cooling (min-max) kW 10.00( 4.50- 11.20) 12.50( 5.70- 14.00) 14.00( 6.00- 16.00) 10.00( 4.50- 11.20) 12.50( 5.70- 14.00) 14.00( 6.00- 16.00)
SEER (single-phase - three-phase) - 7.31(V) - 6.96 8.35(V) - 8.20 7.35(V) - 7.25 6.57(V) - 6.41 6.1(V) - 6.06 5.88(V) - 5.85
Seasonal energy efficiency cooling Ƞs, c % - 331(V) - 325 291(V) - 287 - 309(V) - 304 277.4(V) - 273.8
Performance, heating
Technical features
Noise level in Cooling mode (night-time dB(A) 52 (50) 53 (50) 55 (53) 52 (50) 54 (53) 55 (53)
pressure)
Cooling properties (PED opposite) (Subject to application of the PED, category II) (Not subject to application of the PED)
VRF
Maximum length/Added refrigerant m/(g/m) 75/45 75/60
Preloaded for m 20 20
Minimum length m 5 5
Diameter of pipes (Liq/Gas) mm 9.52 (3/8) - 15.88 (5/8) 9.52 (3/8) - 15.88 (5/8)
inches
Power supply - 3N~ 400V 50Hz (1~ 230V 50Hz) 3N~ 400V 50Hz (1~ 230V 50Hz)
Performance values are stated for RCI-FSR cassettes in accordance with Eurovent benchmarks.
(1)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility and current standards.
(2)
Performance, cooling
Capacity in Cooling mode (min-max) (1*) kW 7.10( 3.20- 8.00) 20.00( 8.00- 22.40) 25.00( 10.00- 28.00) 30.00( 11.20- 33.50)
Performance, heating
Capacity in Heating mode (min-max) (1*) kW 8.00( 3.50- 10.60) 22.40( 6.30- 28.00) 28.00( 8.00- 35.00) 33.50( 9.00- 37.50)
COP (5*)
- 4 3.81 3.63 2.57
Technical features
Noise level in Cooling mode (night-time dB(A) 48 (46) 57 (55) 58 (56) 59 (56)
pressure)
Dimensions (HxWxD) mm 600 X 792 X 300 1380 x 950 x 370 1650 x 1100 x 390
Cooling properties (PED opposite) (Not subject to application of the PED) (Subject, category II)
Maximum length/Added refrigerant m/(g/m) 50/40 100/to be calculated according to technical documentation
Preloaded for m 20 30
Refrigerant - R410A
* To ensure cooling mode at -15°C, use the “cooling only” and “master/slave” switch settings.
(1*)
If longer than 70 m, halve the diameter of the liquid pipe.
(2*)
Shielding must be renewed every 300 m.
(3*)
With 100% connection.
(4)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility and current standards.
(5*)
Performance values are stated for RCI-FSN4 cassettes in accordance with Eurovent benchmarks.
(6*)
Only with a connection rate of 50% to 100%; beyond that, max. 1 or 2 units respectively.
(V) Single-phase version.
Micro VRF
(IVX PRIME & PRIME )
Quantity of indoor units
Outdoor unit Hp 3 4 5 6 8 10 12
Installation with multikits. Installation with multikits. 1 main line. Constant diameter.
Multikit
VRF
L31 L32 L33 L34
H L A
L2
C
L4
B
L1
Outdoor unit Hp 3 4 5 6 8 10 12
* Caution: When connecting RCI cassettes, the max. number is limited to two.
**If tube length exceeds 70m, use a 1/2" instead of 3/8” liquid line.
Benefits
30
Flexibility
2 tubes/3 tubes (8 to 12 hp)
Single-output CH boxes
Hydro-Free
Reception – with
Meeting room Office underfloor heating Technical room
-37% 4 13
FLOOR -18%
SPACE HEIGHT
5 16
6 18
8 26
10 32
784mm
12 39
390mm
30PA
With 30Pa, the unit can be hidden. This solution recirculates the air to force it The OU can be ducted to preserve the
through the grid at speed, therefore avoiding recycling. appearance of the building.
The “GENTLE COOL” regulated blowing temperature function accessible via the wired remote PC-ARFG-E enables the following:
- set the minimum blowing temperature for greater comfort.
- In summer, cold air drafts are prevented by programming an adjustable minimum blowing temperature.
VRF
–
32
40
ambient temperature. This new feature allows a single 1.1kW (0.4Hp) unit to 24 Power input = 1.13kW
1.650
1.380
370 390
950 1.100
Model Unit S S S L L L
RAS-4FS(V)NME RAS-5FS(V)NME RAS-6FS(V)NME RAS-8FSXNME RAS-10FSXNME RAS-12FSXNME
Performance, cooling
SEER - 6.67(V) - 6.61 6.64(V) - 6.61 6.40(V) - 6.37 7.59 8.31 8.26
Seasonal energy efficiency cooling Ƞs, c % 264(V) - 261 262.6(V) - 261 253(V) - 251.8 300.6 329.4 327.4
Performance, heating
Seasonal energy efficiency heating Ƞs, h % 163 173 167 221.8 185.8 183.4
Technical features
Number of fans - 2
Compressor number - 1
VRF
Max. number of connectible units - 13 16 18 26 32 39
Cooling properties (PED opposite) (Not subject to application of the PED) (Subject to application of the PED, category II)
Refrigerant - R410A
Dimension of cooler Low pressure gas mm (inches) - 15.88 (5/8) 19.05 (3/4) 22.2 (7/8)
connections
High pressure gas mm (inches) 15.88 (5/8) 19.05 (3/4) 22.2 (7/8) 25.4 (1)
Electrical features
Compatible controls and accessories (see tab VRF TWIN controls) Discover
SET FREE
Condensation drainage kit Refrigerant connection kit
DBS-26
Mini
Cooling connections
34
Cooling connections
L1
H4
H3
H1
H2 L2 L3
H5
Multikit CH box
4 to 6 Hp 8 to 12 Hp 8 to 12 hp
(energy recovery)
2P 3P 2P 3P
Smart defrosting that optimizes the defrosting cycle and cuts the indoor unit fans during the cycle.
no frost
Time
2 Comfort temperature is
maintained with precision
3 Variable
evaporation
temperature
4
25
24
23 40
energy
%
Very low noise Sound power
22
21
savings level
20 Min
86 dB(A) 72 dB(A)
0.0 20.0 40.0 60.0 80.0 100.0 120.0
Standard mode Silence mode
Stage 3
Indoor unit 1 Temp° Indoor unit 2 Temp°
Stage 1 82.5 86
Stage 2 77.5 81
Stage 3 72.5 76
* JOHNSON CONTROLS - HITACHI AIR CONDITIONING EUROPE SAS participates in the Eurovent Certification Program for AC/VRF/LCP-HP categories; data from certified models are listed in the Eurovent Annual Report (www.
eurovent-certification.com).
37
5 Flexible installation
80 PA
60 cm
minimum
6 Meets RE 2020
VRF
Fan with a structure
improving the airflow
and low electricity
consumption
3-level anti-corrosion
exchanger for high
efficiency
The RE2020 aims to cut energy consumption by
30 % in new buildings compared to that of the
RT2012 and to cut carbon emissions by 30% in Liquid cylinder
buildings by 2030.
The SET FREE Sigma was designed with this Hitachi Scroll Inverter
Compressor
eco-responsible commitment in mind thanks
to its excellent energy performances.
5 HP outdoor group
Unique on the market
Length
max.
Max. drop
Piping
VRF
3-room floor
Piping
–
40
Outdoor units
Model Unit RAS-8FSXNSE RAS-10FSXNSE RAS-12FSXNSE RAS-14FSXNSE RAS-16FSXNSE RAS-18FSXNSE RAS-20FSXNSE RAS-22FSXNSE RAS-24FSXNSE
Performance, cooling
Absorbed capacity Cooling kW 5.40 7.27 8.89 12.12 13.85 14.9 18.6 20.4 22.4
EER - 4.15 3.85 3.77 3.30 3.25 3.35 3.01 3.01 2.99
SEER - 7.50 7.17 6.97 7.47 7.30 6.96 6.29 6.76 6.20
Seasonal energy efficiency cooling Ƞs, c % 297 283.8 275.8 295.8 289 275.4 248.6* 267.4 245*
Performance, heating
COP - 4.75 4.57 4.10 3.74 3.37 3.29 3.35 3.19 3.4
SCOP - 4.17 4.11 4.29 4.48 4.42 4.18 4.14 4.43 4.43
Seasonal energy efficiency heating Ƞs, h % 163.8 161.4 168.6 176.2 173.8 164.2 162.6 174.2 174.2
Technical features
Airflow m3/h 9900 10200 11400 14340 15360 15360 19740 19740 20880
Number of fans - 1 2
Sound pressure (2) (night mode) dB(A) 58 (53) 60 (55) 59 (54) 63 (58) 63 (58) 65 (60) 65 (60) 64 (59) 66 (61)
Dimensions (HxWxD) mm 1725 x 959 x 784 1725 x 1219 x 784 1725 x 1609 x 784
Net weight kg 210 233 289 332 333 382 396 397
VRF
Compressor number - 1 2
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
Electrical features
Unit 1 name RAS-12FSXNSE RAS-12FSXNSE RAS-12FSXNSE RAS-14FSXNSE RAS-16FSXNSE RAS-18FSXNSE RAS-14FSXNSE RAS-18FSXNSE
Unit 2 name RAS-14FSXNSE RAS-16FSXNSE RAS-18FSXNSE RAS-18FSXNSE RAS-18FSXNSE RAS-18FSXNSE RAS-24FSXNSE RAS-22FSXNSE
Absorbed capacity Cooling kW 23.38 22.44 24.24 29.58 28.77 29.85 36.71 35.52
Seasonal energy efficiency cooling Ƞs, c % 289 281 281 291 284 285 262 274
Performance, heating
Absorbed capacity Heating kW 21.18 24.67 26.59 28.77 31.86 34.04 33.55 38.65
Capacity at -7°C (1) kW 59.54 63.70 67.25 72.09 76.41 79.46 81.66 88.68
Capacity at -15°C (1) kW 45.8 48.65 51.31 55.15 58.46 60.40 62.61 67.50
Seasonal energy efficiency heating Ƞs, h % 172 171 166 169 168 164 175 169
Technical features
Airflow m3/h 11140 + 14340 11140 + 15360 14340 + 15360 15360 + 15360 14340 + 20280 15360 + 19740
Number of fans - 3 4
Sound pressure (2) (night mode) dB(A) 64.50 (59.50) 64.50 (59.50) 66 (61) 67 (62) 68 (63) 67.50 (62.50)
Dimensions (HxWxD) mm 1725 x 2198 x 784 1725 x 2458 x 784 1725 x 2858 x 784 1725 x 2848 x 784
Net weight kg 233 + 289 233 + 332 233 + 333 289 + 333 332 + 333 333 + 333 289 + 397 333 + 396
Compressor number - 2 3 4
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
Electrical features
Twin unit connection kit MC-21AN1 MC-21AN1 MC-21AN1 MC-21AN1 MC-30AN1 MC-30AN1 MC-30AN1
Absorbed capacity Cooling kW 37.65 40.53 42.67 45.48 44.5 43.7 44.78
Seasonal energy efficiency cooling Ƞs, c % 260 267 255 244* 289 284 285
Performance, heating
Absorbed capacity Heating kW 39.37 43.89 43.97 44.12 45.49 48.28 50.15
Capacity at -7°C (1) kW 90.38 99.32 99.62 100.06 111.10 113.51 117.06
Capacity at -15°C (1) kW 68.9 75.58 76.01 76.45 84.81 86.32 88.98
Seasonal energy efficiency heating Ƞs, h % 169 174 174 174 167 167 164
Technical features
Airflow m3/h 15360 + 20880 19740 + 19740 19740 + 20880 20880 + 20880 14340 + 15360 + 15360
Number of fans - 4
VRF
Sound power dB(A) 89 87 88 89 89 87 88
Sound pressure (2) (night mode) dB(A) 68.50 (63.50) 67 (62) 68 (63) 69 (64) 68.50 (63.50) 67 (62) 68 (63)
Dimensions (HxWxD) mm 1725 x 2848 x 784 1725 x 3238 x 784 1725 x 3238 x 784 1725 x 3238 x 784 1725 x 3697 x 784 1725 x 3697 x 784 1725 x 3697 x 784
Net weight kg 333 + 397 396 + 396 396 + 397 397 + 397 287 + 330 + 330 329 + 330 + 330 330 + 330 + 330
Compressor number - 4 5 6
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
Electrical features
(1)
For an outside temperature of 20°C and a connection rate of 100%. (2) Anechoic chamber readings taken 1.5 m from the front of the appliance.
(3)
Depending on the application; refer to the technical documentation. (4) Volume regenerated every 300 m. * Etas values (cooling mode) below 250% are not eligible for CEE.
44
VRF SET FREE Sigma Standard
RAS-56FSXNSE RAS-58FSXNSE RAS-60FSXNSE RAS-62FSXNSE RAS-64FSXNSE RAS-66FSXNSE RAS-68FSXNSE
Twin unit connection kit MC-NP31SA MC-NP31SA MC-NP31SA MC-NP31SA MC-NP31SA MC-NP31SA MC-NP31SA
Absorbed capacity Cooling kW 51.99 50.44 52.26 59.47 57.93 59.74 63.27
SEER (average climate) - 6.79 7.01 6.75 6.45 6.63 6.43 6.54
Seasonal energy efficiency cooling Ƞs, c % 268 268 277 255 262 254 258
Performance, heating
Absorbed capacity Heating kW 51.12 55.67 56.39 56.47 61.29 61.42 65.29
Capacity at -7°C (1) kW 122.78 128.41 130.12 133.77 140.04 140.43 147.87
Seasonal energy efficiency heating Ƞs, h % 171 171 167 174 171 171 174
Technical features
Air flow (Cooling) m3/h 14340 + 15360 + 15360 + 15360 + 15361 + 15360 + 14340 + 20880 + 15360 + 19740 + 15360 + 20880 + 19740 + 19740 +
20880 19740 20880 20880 20880 20880 20880
Number of fans - 6
Sound pressure level Cooling (night) (2) dB(A) 69.5 (62) 69.5 (62) 70.0 (63) 70.0 (63) 70.0 (63) 70.5 (63) 70.0 (63)
Dimensions (HxWxD) mm 1725 x 4087 x 784 1725 x 4477 x 784 1725 x 4867 x 784
Net weight kg 287 + 330 + 399 330 + 330 + 398 330 + 330 + 399 287 + 399 + 399 330 + 398 + 399 330 + 398 + 399 398 + 398 + 399
Compressor number - 5 6 5 6
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
Twin unit connection kit MC-NP31SA MC-NP31SA MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA
Absorbed capacity Cooling kW 65.41 67.22 66.91 65.36 67.18 74.39 73.91
SEER (average climate) - 6.36 6.19 6.89 7.05 6.85 6.60 6.57
Seasonal energy efficiency cooling Ƞs, c % 251 244(*) 272 279 271 261 260
Performance, heating
Absorbed capacity Heating kW 66.02 66.18 68.13 72.69 73.41 74.06 77.45
Capacity at -7°C (1) kW 149.62 150.10 158.34 168.14 169.89 174.86 178.60
Capacity at -15°C (1) kW 114.22 114.68 121.24 127.90 129.33 133.68 136.20
SCOP (average climate) - 4.43 4.43 4.31 4.24 4.24 4.24 4.35
Seasonal energy efficiency heating Ƞs, h % 174 174 169 166 166 172 171
Technical features
Air flow (Cooling) m3/h 19740 + 20880 x 2 20880 x 3 14340 + 15360 x 2 15360 x 3 + 19740 15361 x 3 + 20880 14340 + 15360 + 15360 + 15360 +
+ 20880 20880 x 2 20880 x 2
Number of fans - 6 8
VRF
Sound power dB(A) 90 91 92 92 92 92 92
Sound pressure level Cooling (night) (2) dB(A) 70 (63.5) 71 (63.5) 71 (63.5) 71 (64) 71.5 (64) 71 (65) 71 (65)
Dimensions (HxWxD) mm 1725 x 4087 x 784 1725 x 5326 x 784 1725 x 5716 x 784
Net weight kg 398 + 399 + 399 399 + 399 + 399 287 + 330 + 330 330 + 330 + 330 330 + 330 + 330 287 + 330 + 399 329 + 330 + 399
+ 399 + 398 + 399 + 399 + 399
Compressor number - 6 7 8 7 8
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
(1)
For an outside temperature of 20°C and a connection rate of 100%. (2) Anechoic chamber readings taken 1.5 m from the front of the appliance.
(3)
Depending on the application; refer to the technical documentation. (4) Volume regenerated every 300 m. * Etas values (cooling mode) below 250% are not eligible for CEE.
46
VRF SET FREE Sigma Standard
RAS-84FSXNSE RAS-86FSXNSE RAS-88FSXNSE RAS-90FSXNSE RAS-92FSXNSE RAS-94FSXNSE RAS-96FSXNSE
Twin unit connection kit MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA MC-NP40SA
Absorbed capacity Cooling kW 74.67 81.88 81.07 82.15 86.06 87.82 89.63
SEER (average climate) - 6.58 6.38 6.36 6.37 6.45 6.32 6.20
Seasonal energy efficiency cooling Ƞs, c % 251 252 251 252 255 250 245(*)
Performance, heating
Absorbed capacity Heating kW 79.63 79.69 83.07 84.96 88.85 89.27 89.71
Capacity at -7°C (1) kW 182.86 186.49 190.24 193.82 201.30 202.36 155.45
Capacity at -15°C (1) kW 139.40 142.71 145.24 147.93 153.60 154.51 203.46
SCOP (average climate) - 4.31 4.44 4.41 4.37 4.43 4.43 4.43
Seasonal energy efficiency heating Ƞs, h % 174 174 173 172 174 174 174
Technical features
Air flow (Cooling) m3/h 15360x2 + 20880 x 2 14340x2 + 20880 x 3 15360 + 20880 x 3 15360 + 20880 x 3 19740 x 2 19740 x 2 20880 x 4
+ 20880 x 2 + 20880 x 3
Number of fans - 8
Sound pressure level Cooling (night) (2) dB(A) 71.5 (65) 71.5 (65) 71.5 (65) 72 (65) 72 (65) 71.5 (65) 72 (65)
Dimensions (HxWxD) mm 1725 x 5716 x 784 1725 x 6106 x 784 1725 x 6496 x 784
Net weight kg 330 + 330 + 399 287 + 399 + 399 329 + 399 + 399 330 + 399 + 399 398 + 398 + 399 398 + 399 + 399 399 + 399 + 399
+ 399 + 399 + 399 + 399 + 399 + 399 + 399
Compressor number - 7 8
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
(1)
For an outside temperature of 20°C and a connection rate of 100%. (2) Anechoic chamber readings taken 1.5 m from the front of the appliance.
(3)
Depending on the application; refer to the technical documentation. (4) Volume regenerated every 300 m. * Etas values (cooling mode) below 250% are not eligible for CEE.
47
47
E-242SN3 E-162XN3
E-302SN3 E-202XN3
MW-NP2682A3 E-242XN3
E-322XN3
Outdoor unit Number of outdoor units Reversible Multikit Reference Energy recovery Multikit Reference
RAS-(56-72)FSXNSE 3 MC-NP31SA -
RAS-(74-96)FSXNSE 4 MC-NP40SA -
VRF
DBS-TP10A
–
48
Exclusive solution -20°C -10°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C
3T and 2T single unit to meet the needs of both energy recovery applications
and reversible heat pump uses.
Variable evaporation temperature
The control logic built into SIGMA units saves more energy and increases user
comfort during the summer. Set a high evaporative target temperature to suit
Advanced anti-corrosion treatment the building’s heating needs and the SIGMA becomes ever more economical
Thanks to its triple treatment, SIGMA offers the best protection on the market to use. Choose a low target temperature to suit heat requirements and the
for coastal locations. SIGMA provides comfort even faster in cooling mode.
Backup function
Isolates an outdoor unit for maintenance while other units continue to
operate.
Epoxy resin layer
Waterproof film layer
Lubricant layer
Aluminum
Epoxy resin layer
Waterproof film layer
Lubricant layer
Outdoor units
RAS - 8FSXNPE
RAS - 10FSXNPE
RAS - 5FSXNPE RAS - 12FSXNPE RAS - 16FSXNPE
RAS - 6FSXNPE RAS - 14FSXNPE RAS - 18FSXNPE
VRF SET FREE Sigma High-Performance 49
Model Unit RAS-5FSXNPE RAS-6FSXNPE RAS-8FSXNPE RAS-10FSXNPE RAS-12FSXNPE RAS-14FSXNPE RAS-16FSXNPE RAS-18FSXNPE
Performance, cooling
SEER (average climate) - 8.33 8.00 7.97 8.06 7.91 7.69 7.76 7.60
Seasonal energy efficiency cooling % 330.2 317 315.8 319.4 313.4 304.6 304.6 301
Ƞs, c
Performance, heating
Absorbed capacity Heating kW 2.80 3.52 5.08 6.65 8.01 10.84 12.92 14.97
Capacity at -7°C (1) kW 13.38 15.04 20.92 25.10 27.78 34.93 40.06 41.46
SCOP (average climate) - 5.06 4.58 4.55 4.73 4.81 4.63 4.84 4.81
Seasonal energy efficiency heating % 199.4 180.2 179.0 186.2 189.4 182.2 182.2 189.4
Ƞs, h
Technical features
Number of fans - 1 2
Dimensions (HxWxD) mm 1725 x 959 x 784 1725 x 1219 x 784 1725 x 1609 x 784
VRF
Compressor number - 1 2
Cooling properties (PED opposite) (Subject to application of the PED, category II)
Refrigerant - R410A
Electrical features
Maximum current A 11.5 12.0 15.0 19.0 23.0 28.0 33.0 34.5
Compatible controls and accessories (see tab VRF TWIN controls p.XX)
Condensation drainage kit Refrigerant connection kit
DBS-TP10A See page 304
Compatible with
FSXNSE and FSXNPE
50
VRF SET FREE Sigma High Performance
RAS-20FSXNPE RAS-22FSXNPE RAS-24FSXNPE RAS-26FSXNPE RAS-28FSXNPE RAS-30FSXNPE RAS-32FSXNPE RAS-34FSXNPE RAS-36FSXNPE
Unit 1 name RAS-10FSXNPE RAS-10FSXNPE RAS-12FSXNPE RAS-10FSXNPE RAS-12FSXNPE RAS-12FSXNPE RAS-14FSXNPE RAS-16FSXNPE RAS-18FSXNPE
Unit 2 name RAS-10FSXNPE RAS-12FSXNPE RAS-12FSXNPE RAS-16FSXNPE RAS-16FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE
Absorbed capacity Cooling kW 12.36 14.62 16.88 17.69 12.36 14.62 16.88 17.69 19.69
EER - 4.53 4.21 3.97 4.13 3.94 3.93 3.70 3.91 3.91
SEER (average climate) - 8.06 7.97 7.91 7.92 7.71 7.49 7.62 7.83 7.60
Seasonal energy efficiency cooling % 319 316 313 314 305 294 302 310 301
Ƞs, c
Performance, heating
Absorbed capacity Heating kW 13.29 14.66 16.56 19.81 13.29 14.66 16.56 19.81 21.53
Capacity at -7°C (1) kW 50.2 52.88 57.41 65.96 69.76 70.35 75.64 81.52 82.92
Capacity at -15°C (1) kW 39.6 41.2 44.23 51.93 54.39 54.16 61.49 63.40 63.80
COP - 4.74 4.71 4.68 4.17 4.18 4.07 3.91 3.80 3.74
SCOP (average climate) - 4.76 4.76 4.81 4.78 4.82 4.71 4.63 4.72 4.64
Seasonal energy efficiency heating % 187 187 189 188 190 185 182 186 182
Ƞs, h
Technical features
Airflow m3/h 13140 + 13140 13140 + 19560 13141 + 21720 14580 + 21720 21720 + 21720
Number of fans - 4
Sound pressure (2) (night mode) dB(A) 62 (57) 62.5 5 (57.5) 63 (58) 66 (61) 66 (61) 67 (62) 68 (63)
Net weight kg 278 + 278 278 + 282 282 + 282 278 + 369 282 + 369 282 + 384 292 + 384 369 + 384 384 + 384
Compressor number - 2 3 4
Refrigerant - R410A
Refrigerant load kg 17 17.8 18.6 18.5 19.3 19.9 19.9 20.6 21.2
Dimension
of cooler Low pressure gas inches 1-1/8 1-1/4 1-1/2
connections
High pressure gas inches 7/8 1 1-1/8
Electrical features
Maximum current A 38.0 42.0 46.0 51.5 55.5 57.0 62.0 67.0 68.5
Unit 1 name RAS-12FSXNPE RAS-12FSXNPE RAS-14FSXNPE RAS-12FSXNPE RAS-14FSXNPE RAS-12FSXNPE RAS-14FSXNPE RAS-16FSXNPE RAS-18FSXNPE
Unit 2 name RAS-12FSXNPE RAS-14FSXNPE RAS-14FSXNPE RAS-14FSXNPE RAS-14FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE
Unit 3 name RAS-14FSXNPE RAS-14FSXNPE RAS-14FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE RAS-18FSXNPE
Capacity Cooling kW 106 112 118 122 128 136 140 145 150
Absorbed capacity Cooling kW 21.61 24.32 24.30 32.36 35.29 34.65 37.10 37.08 38.36
Seasonal energy efficiency cooling % 304 304 304 302 302 301 301 307 301
Ƞs, c
Performance, heating
Capacity Heating kW 118 125 132 140 145 150 155 160 165
Absorbed capacity Heating kW 23.35 25.56 27.89 34.2 36.41 38.09 40.27 42.34 44.12
Capacity at -7°C (1) kW 88.98 95.73 102.47 105.30 110.57 114.09 116.36 121.47 122.17
Capacity at -15°C (1) kW 71.78 80.19 88.59 84.41 91.67 85.48 92.80 94.12 93.99
COP - 4.47 4.29 4.15 4.09 3.98 3.94 3.85 3.78 3.74
SCOP (average climate) - 4.17 4.68 4.63 4.68 4.63 4.68 4.64 4.70 4.64
Seasonal energy efficiency heating % 186 184 182 184 182 184 182 185 182
Ƞs, h
Technical features
Airflow m3/h 13140 + 13140 + 13140 + 14580 + 14580 + 14580 + 13140 + 14580 + 14580 + 14580 + 13140 + 21720 + 14580 + 21720 + 19560 + 21720 + 21720 + 21720 +
14580 14580 14580 21720 21720 21720 21720 21720 21720
Number of fans - 6
VRF
Sound power dB(A) 89 90 91
Sound pressure (2) (night mode) dB(A) 65.5 (60.5) 66 (61) 67 (62) 67.5 (62.5) 68 (63) 68.5 (63.5) 69 (64) 70 (65) 70 (65)
Dimensions (HxWxD) mm 1725 x 3697 x 784 1725 x 4087 x 784 1725 x 4477 x 784 1725 x 4867 x 784
Net weight kg 282 + 282 + 292 282 + 292 + 292 292 + 292 + 292 282 + 292 + 384 292 + 292 + 384 282 + 384 + 384 311 + 311 + 408 350 + 365 + 365 365 + 365 + 365
Compressor number - 3 4 5 6
Refrigerant - R410A
Electrical features
Maximum current A 73.5 78.5 83.0 85.0 89.5 91.0 96.0 101.0 103.0
(1)
For an outside temp. of 20°C and a connection rate of 100%. (2) Anechoic chamber readings taken 1.5 m from the front of the appliance.
(3)
Depending on the application; refer to the technical documentation. (4) Volume to regenerate every 300 m.
52
VRF SET FREE Sigma High Performance
RAS-56FSXNPE RAS-58FSXNPE RAS-60FSXNPE RAS-62FSXNPE RAS-64FSXNPE
Seasonal energy efficiency cooling Ƞs, c % 303 302 313 318 323
Performance, heating
Seasonal energy efficiency heating Ƞs, h % 185 184 186 188 190
Technical features
Air flow (Cooling) m3/h 13140 + 14580 + 21720 13140 + 14580x2 + 21721 14580x2 + 19560x2 14580 + 19560x3 19560x4
Number of fans - 8
Sound pressure level Cooling (night) (2) dB(A) 68.5 (61) 68.5 (61) 70.0 (63) 70.5 (64) 71.0 (65)
Dimensions (HxWxD) mm 1725 x 5326 x 784 1725 x 6106 x 784 1725 x 6496 x 784
Net weight kg 282 + 282 + 297 + 384 282 + 297 + 297 + 384 297 + 297 + 369 + 369 297 + 369 + 369 + 369 369 + 369 + 369 + 369
Compressor number - 5 6 7
Refrigerant - R410A
Performance, heating
Technical features
Air flow (Cooling) m3/h 19569x3 + 21720 19560x2 + 21720x2 19760 + 21720x3 21720x4
Number of fans - 8
VRF
Sound power dB(A) 91 92 91 92
Sound pressure level Cooling (night) (2) dB(A) 71 (65) 71 (65) 71 (65) 71 (65)
Net weight kg 369 + 369 + 369 + 384 369 + 369 + 384 + 384 369 + 384 + 384 + 384 384 + 384 + 384 + 384
Compressor number - 8
Refrigerant - R410A
E-242SN3 E-162XN3
E-302SN3 E-202XN3
MW-NP2682A3 E-242XN3
E-322XN3
Outdoor unit Number of outdoor units Reversible Multikit Reference Energy recovery Multikit Reference
RAS-(56-72)FSXNPE 4 MC-NP40SA -
DBS-TP10A
–
55
VRF
Cooling Heating Cooling Heating
Description
- CH box range with 1 output. - Compatible with extra long pipework.
- Up to 8 indoor units per CH box. - Ultra quiet at max. 33 dB(A).
- Compactness - Flare cooling connections.
- Lightweight.
- Connect 2-pipes only (gas pipes).
- No condensate connection.
Height difference between each CH box or between a CH box and an indoor unit m < 15
Weight kg 6
* If connecting multiple indoor units per branch, use the Hitachi cooling fittings referenced P. 54.
** Max. noise means the maximum operating noise level of the CH box emitted when the unit is in simultaneous cooling and heating or in defrost mode.
–
56
Multi-output CH xbo
Low pressure gas
Gas liquid
Description
- Range of multi-output CH boxes. - Ultra quiet up to 31 dB(A).
- Up to 96 indoor units per CH box. - Cooling connections brazed (outdoor unit) and flare (indoor unit).
- Low-height. - Accessories delivered as standard: reduction and increase to allow a brazed
- Low-volume. output on the indoor unit side.
- Lightweight.
- No condensate connection.
Number of branches 4 8 12 16
Total max. power per CH Hp (kW 16.00 (max. 44.8 kW) 30.00 (max. 85 kW) 30.00 (max. 85 kW) 30.00 (max. 85 kW)
cooling)
Total max. power per branch Hp (kW 6Hp (16 kW)
cooling)
Max. lengths after box m 40 (30***)
Height difference between each CH box or between a CH box and an indoor unit m < 15
Dimensions (HxWxD) mm 260 x 303 x 352 260 x 543 x 352 260 x 783 x 352 260 x 1023 x 352
Weight kg 14 25 36 47
Diameters of cooling system – outdoor unit inches 7/8” - 1” - 1/2” 7/8” - 1” 1/8 - 1/2” 1” - 1” 1/8 - 5/8” 1” 1/8 - 1” 1/4 - 3/4”
Sound pressure level dBA 31 (46 max**) 31 (46 max**) 34 (46 max**) 34 (46 max**)
* If connecting multiple indoor units per branch, use the Hitachi cooling fittings referenced P. 54.
** Max. noise means the maximum operating noise level of the CH box emitted when the unit is in simultaneous cooling and heating or in defrost mode.
***When the recommended number of indoor units is exceeded.
57
Flexible installation
Single and multi-output boxes may be combined when 5, 9, 13 or 17 outputs are required.
Single-output Multi-outputs
Less network
Corridor
Room
Single-output Multi-outputs
6 Multikit required 0
92 points (Soldering: 57/Flare: 32) Connection points 34 points (Soldering: 6/Flare: 28)
VRF
By positioning the boxes in the center of the units (save tubes, less labor and reduced load).
Single-output Multi-outputs
Simplified installation:
- Fewer connection points
- No condensate connection
Single-output Multi-outputs
60 m Pipe length 63 m
6 Multikit required 1
92 points (Soldering: 57/Flare: 32) Connection points 40 points (Soldering: 12/Flare: 28)
Examples of applications
Retirement homes
CH box
Multi-outputs
IU heat recovery
Restaurant/Hotel
Automatic heating and cooling on indoor units
Offices
Server room
59
Sizing rules for cooling connections Max. features of the cooling Symbol ≤ Recommended number of ≥ Recommended number of
system indoor units* indoor units*
(*) See the technical manual for the recommended number of indoor units (TC). (1) Longer piping (up to 110 m) is available for all models. Remember, you must obtain prior approval from Hitachi’s Customer Service team if
the difference in height is greater than 50 m. Please contact Hitachi’s Customer Service department to provide them with the necessary features of the system so that they can carry out a feasibility study. (2) The recommended
height difference between the CH box and the indoor unit must be no more than 15 m. If the height difference is greater, it could compromise the operating performance. (3) If following the recommended number of indoor
units, the total length of piping must be less than 1,000 m due to the additional refrigerant load limit. If you exceed the recommended number of indoor units, the restrictions for the total length of the pipes apply.
Connection A B C
2 tubes H5
Pipe connection
Pipe connection kit 1 kit 2
First multikit
H1
L3
H2
L2 L1
L3
L3 L3
VRF
Connection A B C
3 tubes H6
First multikit
L3
CH-M CH
L3
L4 L4
H1
H3
e f
H5
g h i
* These maximum values may vary depending on the maximum number of indoor units connected. Refer to current technical documentation.
** Keep a straight distance of 500 mm or more downstream of the connection kit.
–
60
Ideal solution for city More comfort, every time Compatible with all
centers The IVX Centrifugal VRF can provide air-
conditioning for up to 6 different zones and offers
SYSTEM FREE control
Installed in suspended ceilings, units are invisible
from the outside.
more comfort as you can independently control systems:
each indoor unit. From individual control to central controls and
The premium compressor installed on these units communication gateways for direct integration
Easy to implement provides smart defrosting. This lengthens the
warming period and brings more comfort.
into a BMS.
Suspended single-block system: less footprint.
Intake and fan blower can be adjusted to suit the
situation (same side or at right angle). Available Silence Installation
pressure up to 120 Pa. You can opt for 2 branches with up to 4 indoor
Fans are equipped with a frequency dimmer, units or up to 6 indoor units on one branch. Set
The air intake and output grids are also which achieves sound levels unmatched on the
interchangeable, increasing your installation up with a maximum of 5 different indoor units for
market. RASC-(4-6)HNPE or 6 indoor units for RASC-(8/10)
options in any part of the building.
HNPE. Compatibility with DX KIT (1x1), with the
control based on the air intake.
IVX model
Centrifugal
Outdoor units
555 620
1.015 1.360
1.415 1.850
RASC-4HNPE
RASC-5HNPE RASC-8HNPE
RASC-6HNPE RASC-10HNPE
Micro VRF IVX Centrifugal 61
Performance, cooling
Performance, heating
Technical features
Compressor - SCROLL
VRF
Min. power of indoor unit Hp 0.8
Cooling properties
Refrigerant - R410A
Maximum length/Added refrigerant m/g/m 75/see technical documentation 100/see technical documentation
Preloaded for m 30
(1)
The information provided is for information purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility and current standards.
(*)
Etas values (cooling mode) below 250% are not eligible for CEE. Its seasonal performance follows standard EN14825 (2013). HITACHI Centrifugal units are VRF-certified, so the specified performance applies for units only.
Outdoor unit Hp 4 5 6 8 10
Outdoor unit Hp 4 5 6 8 10
75~120%
1 to 4
3 to 4.8 Hp 3.8 to 6 Hp 4.5 to 7.2 6 to 9.6 Hp 7.5 to 12 Hp
75~100%
Max. number of indoor units 5
3 to 4 Hp 3.8 to 5 Hp 4.5 to 6 Hp 6 to 8 Hp 7.5 to 10 Hp
- 75~100%
6
- 6 to 8 Hp 7.5 to 10 Hp
* If more than 4 indoor units are connected, the power of the indoor units must be balanced out according to the table below.
The most powerful unit in the combination 0.80 1.00 1.30 1.50 1.80 2.00 2.30 2.50 3.00 4.00 5.00 6.00
The least powerful unit in the combination 0.80 1.00 1.30 1.50 1.80 2.00
2 8+3 8+2 10 + 3 10 + 2 -
Max. number of indoor units
3 8+2+2 8 + 1.5 + 1.5 8+1+1 10 + 1.5 + 1.5 10 + 1 + 1
Units of 4 to 10 Hp:
Permitted installation (1 to 6 indoor units)
- Installation with deviations.
- 1 or 2 lines with a constant diameter.
- Installation with more than 4 indoor units: cooler connections with one main permitted line (2 Multikit
branches not allowed).
L2
L4
L1
63
Outdoor unit Hp 4 5 6 8 10
Max. drop from outdoor unit to indoor unit (H) (outdoor unit above/below) m 30/20
**If the pipe is longer than 70m, use a 1/2” liquid line instead of 3/8”.
VRF
Exclusive to Hitachi: all our System Free indoor units
64
VRF
& Utopia Prime
indor units Capacities Cooling (Hp)
0.4 0.6 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 4.0 5.0 6.0 8.0 10.0 16.0 20.0
Cassettes p.74
RCIM-FSRE (600x600)
• Refrigerant R32 • • • • • • • • • •
• Refrigerant R410A • • • • • • • • • • - - - - - - - -
600x600
RCI-FSR (800x800)
• Refrigerant R32
• Refrigerant R410A • • • • • • • • • • •
- - -
• • • • • • • • • • • - - - -
800x800
Ducted p.84
1. RPIL-FSRE (ultra
• • • • • •
VRF
compact: up to 100Pa)
• Refrigerant R32 • • • • • • - - - - - - - - - - - -
• Refrigerant R410A
2. RPI-FSRE (medium: up
to 150Pa)
• Refrigerant R32 • • • • • • • • • •
• Refrigerant R410A
- - - -
• • • • • • • • • • - - - -
3. RPIH-FSRE (high
pressure: up to 200Pa)
• Refrigerant R32 • • •
• Refrigerant R410A
- - - - - - - - - - -
• • • - - - -
4. RPI-FSN3E (high
capacity: up to 220Pa)
• Refrigerant R410A - - - - - - - - - - - - - - • • - -
5. RPI-FSN3PE (high
capacity: up to 220Pa)
• Refrigerant R410A - - - - - - - - - - - - - - - - • •
• Refrigerant R410A
Console p.96
RPF(I)-FSN2E
Enclosed or non-enclosed
• Refrigerant R410A
- - - • • • • • • • - - - - - - - -
VRF
66
4-way cassette
2-way cassette
RCD-0.8-6.0 FSR
Ducted
Wall
Console
RPF-1.0-2.5FSN2E
Ceiling unit
VRF
- Available from 3.8 to 16 kW.
- Air range suitable for large rooms.
- 4 fan speeds.
- Connects from 3 directions.
RPC-1.5-6.0 FSR
Hydro Free
-O
N/OFF,
VRF
-T
emperature Setting (normal or reduced mode),
-M
ore energy savings than CSNET.
CSNET Manager 2
T10/T15
VRF
Hitachi Multikit
connection for improved
refrigerant distribution
VRF
a straight line.
- More space between the main line and the
indoor unit line; makes it easier to use a
pipe cutter to cut one of the pipes.
sVRFTWINindorut
1
Save energy with the motion sensor
10 min
20 min 30 min
Phase A Phase B
Activity 10 minutes if empty
The cassette operates at the setpoint - Adjusts the temperature by +/- 1°C
temperature and the chosen fan speed. depending on the operating mode.
- Sets the fan speed to one setting lower. Phase C Phase D
20 minutes if empty 30 minutes if empty
3 OPTIONS:
- Adjusts the temperature by +/- 2°C
depending on the operating mode. - 1. MODE ON: stays in Phase C mode.
- Sets the fan speed to one setting lower. - 2. STAND BY MODE: the indoor unit
enters Unit-OFF mode and returns
to normal operation when it detects
motion.
- 3. Off MODE: the inside unit turns off
and turn on again manually.
The motion sensor controls the indoor unit in operation:
- Number of people present in the room
- Up to 14% energy savings,
- Option available for: 600 x 600 cassette, 800 x 800 cassette, ducted, ceiling unit.
Perfect integration
Modular suspended
ceiling
600 x 600 mm
4-way cassette
dimensions
570 mm
570 mm
3
Condensate extraction up to 850 mm
850 mm
- Standard integration with cassette and ducted type units,
- Optional four ceiling units,
- The pump comes on automatically as soon as Cooling mode is
selected,
- Self-powered condensing pump: any fault on a unit’s
condensing pump will not affect the rest of the system.
4
Low noise level with the remote
regulator (wall units 0.4 to 1.5 hp)
VRF
With indoor wall units, you can place the regulator outside of the room, significantly reducing noise levels for the
best acoustic comfort.
6 IU compatibility with
outdoor units
* For more information, please refer to the technical documentation. ** Ceiling-mount optional.
–
76
Indoor units
570
570
285
620
30
620
RCIM-0.4FSRE RCIM-1.5FSRE
RCIM-0.6FSRE RCIM-2.0FSRE
RCIM-0.8FSRE RCIM-2.5FSRE
RCIM-1.0FSRE
600 x 600 4-way cassette 77
Indoor units Unit RCIM-0.4FSRE RCIM-0.6FSRE RCIM-0.8FSRE RCIM-1.0FSRE RCIM-1.5FSRE RCIM-2.0FSRE RCIM-2.5FSRE
Power (adjustable) Hp 0.40 0.60 0.80 1 1.30 1.50 1.80 2.00 2.30 2.50(*)
Capacity Cooling UTOPIA Prime & IVX kW not available 2.00 2.50 3.60 5.00 5.60
Capacity Heating UTOPIA Prime & IVX kW not available 2.20 2.80 4.00 5.60 6.30
Capacity Cooling SET FREE kW 1.10 1.70 2.20 2.80 3.80 4.00 5.20 5.60 6.70 7.10
Capacity Heating SET FREE kW 1.25 1.90 2.50 3.20 4.20 4.80 5.60 6.30 7.50 8.50
Noise level in Cooling mode (pressure) (low/medium/ dB(A) 24.5/25/27/29 24.5/28/30/34 24.5/29/33/36 24.5/30/34/38 27.5/33/37/41 31/35/39/45 35/39/43/47
high speed1/high speed2)(1)(3)
Sound power dB(A) 43 47 50 51 54 56 60
Airflow in Cooling mode (low/medium/high speed1/ m³/h 360/414/468/510 360/450/510/600 360/480/570/660 360/510/600/720 420/570/660/780 480/600/720/900 600/720/840/960
high speed2)(4)
Condensing pump - Yes
Max. current A 5
Decorative panel
VRF
You can have multiple contacts with the connector PCC-1A : progress report, error report, thermostat control, remote “Start/Stop”.
Silent-Iconic panels
for cassette 840x840
Design Design
White Black
Discover Silent-Iconic
79
Features
VRF
4.5
1.5 m 4
3.5
2m 3
TwinSense panel
950
40
950
P-AP160NAE2
–
81
VRF
Compatible with all panels on 4-way 800x800 cassettes
Silent-Iconic with
TwinSense panel Standard panel Silent-Iconic Silent-Iconic
elevator screen
Indoor units
840 840
840 840
248 298
950 950
40 40
950 950
RCI-1.0FSR RCI-3.0FSR
RCI-1.5FSR RCI-4.0FSR
RCI-2.0FSR RCI-5.0FSR
RCI-2.5FSR RCI-6.0FSR
840 x 840 4-way cassette 83
Indoor units Unit RCI-1.0FSR RCI-1.5FSR RCI-2.0FSR RCI-2.5FSR RCI-3.0FSR RCI-4.0FSR RCI-5.0FSR RCI-6.0FSR
Power (adjustable) Hp 1.00 1.30 1.50 1.80 2.00 2.30 2.50 3.00 4.00 5.00 6.00
Capacity Cooling UTOPIA Prime & IVX kW 2.50 3.60 5.00 5.60 7.10 11.20 14.00 16.00
Capacity Heating UTOPIA Prime & IVX kW 2.80 4.00 5.60 6.30 8.00 12.50 16.00 18.00
Capacity Cooling SET FREE kW 2.80 3.80 4.00 5.20 5.60 6.70 7.10 8.00 11.2 14 16
Capacity Heating SET FREE kW 3.20 4.20 4.80 5.60 6.30 7.50 8.50 9.00 12.5 16 18
Noise level in Cooling mode (pressure) (low/ dB(A) 27/28/30/33 27/30/31/35 27/30/32/37 28/32/36/42 33/39/43/48 35/40/45/48 37/41/46/48
medium/high speed1/high speed2)(1)(3)
Sound power dB(A) 52 53 55 56 57 64 64 65
Airflow in Cooling mode (low/medium/high m³/h 540/660/780/900 660/840/1020/1260 660/840/1020/1320 840/1080/1380/1620840/1080/1380/1620 1200/1440/1860/2220 1260/1560/1980/2220 1320/1680/2100/2220
speed1/high speed2) (4)
Condensing pump - Yes
Net weight of the box + front panel kg 20 + 6.50 21 + 6.50 22 + 6.50 26 + 6.50
Max. current A 5
Part number for standard White front panel - P-N23NA2 (P-AP160KA3-EU)
(Black)
TwinSense white panel (motion sensor) P-AP160NAE2
(1)
Sound pressure is measured under the following conditions: 1.50 m below the unit.
(2)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility and current standards.
(3)
Very high-speed access is possible with remote controls PC-ARFP1E and PC-ARH1E.
(4)
Very low speed is available in Thermo-off mode.
Type of front panel White front panel design White front panel design blanc equipped with lifting grid Black front panel design
VRF
Panel lift d7 01 02 03 04 05 06 07
Control lowering on wired remote control PC-ARFG-E Lowers in 7 stages 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m 3.5 m 4.0 m
You can have multiple contacts with the connector PCC-1A : progress report, error report, thermostat control, remote “Start/Stop”.
Compatible controls and accessories (see tab VRF TWIN controls p.XX)
Simple wired controller Infrared controller Intuitive multifunction Fresh air kit
PC-ARH1E PC-AWR cable control PD-75A
PC-ARFG-E
2-way cassette
Indoor units
860 1.420
630 630
345 345
710 710
30 30
1.100 1.660
RCD-0.8FSR
RCD-1.0FSR
RCD-1.5FSR
RCD-2.0FSR RCD-4.0FSR
RCD-2.5FSR RCD-5.0FSR
RCD-3.0FSR RCD-6.0FSR
2-way cassette 85
Indoor units Unit RCD- RCD- RCD- RCD- RCD- RCD- RCD- RCD- RCD-
0.8FSR 1.0FSR 1.5FSR 2.0FSR 2.5FSR 3.0FSR 4.0FSR 5.0FSR 6.0FSR
Power (adjustable) Hp 0.80 1.00 1.30 1.50 1.80 2.00 2.30 2.50 3.00 4.00 5.00 6.00
Capacity Cooling UTOPIA Prime & IVX kW 2.00 2.50 3.60 5.00 5.60 7.10 10.00 12.50 14.00
Capacity Heating UTOPIA Prime & IVX kW 2.20 2.80 4.00 5.60 6.30 8.00 11.20 14.00 16.00
Capacity Cooling SET FREE kW 2.20 2.80 3.80 4.00 5.20 5.60 6.70 7.10 8.00 11.20 14.00 16.00
Capacity Heating SET FREE kW 2.50 3.20 4.20 4.80 5.60 6.30 7.50 8.50 9.00 12.50 16.00 18.00
Noise level in Cooling mode (pressure) (low/ dB(A) 27/28/29/30 27/28/29/31 30/31/34/37 30/33/36/39 33/36/39/42 33/38/42/45 34/37/40/43 35/41/44/47 39/42/45/48
medium/high speed1/high speed2)(1)(3)
Sound power dB(A) 44 46 49 51 52 55 55 55 59
Airflow in Cooling mode (low/medium/high m³/h 390/450/540/600 420/510/570/660 600/690/780/900 630/750/870/990 750/870/990/1110 750/960/1110/1260 1200/1380/1590/1800 1260/1620/1860/2100 1440/1710/1950/2220
speed1/high speed2) (4)
Condensing pump - yes
Max. current A 5
VRF
You can have multiple contacts with the connector PCC-1A : progress report, error report, thermostat control, remote “Start/Stop”.
Compatible controls and accessories (see tab VRF TWIN Controls p.XX)
Simple wired controller Infrared controller Intuitive multifunction cable control
PC-ARH1E PC-AWR PC-ARFG-E
Ducted unit
Easy maintenance
Extracts up to 850 mm condensation. Filter is accessible from below or the
side (0.4 to 6 hp).
Poten�alfor
Potential fordiscomfort
discomfort GentleCool
GentleCool NoNocold
colddrafts
dra�s
Optimal
comfort
<8 °C >12°C >14°C >16°C
→ COLD DRAFT
Slim Ducted unit 100 Pa Ducted unit 150 Pa 4 to Ducted unit 200 Pa 11 to
– 1.1 to 4 kW 16 kW 16 kW
- Integrated and removable condensation - Condensate extraction pump included. - Condensate extraction pump included.
extraction pump. - Intake from the rear and below (optional). - Intake from the rear.
- Filter accessible from below or from the - Optional motion sensor. - Filter accessible from below or from the left
right side. - Height: 240 mm or right side.
- Low-height: 197 mm - Insulation M1 (M0 available on request), - Insulation M1 (M0 available on request).
- Refrigerant connections from the rear. - Electrics box (can be removed, sizes 1.5 and
- Electric box (can be remote), 2 hp).
- Air intake from the rear or below (optional, - Filter accessible from below or from the left
- Insulation M1 (M0 available on request). or right side.
Indoor units
RPIL-0.4FSRE
RPIL-0.6FSRE
RPIL-0.8FSRE RPI-4.0FSRE RPIH-4.0FSRE
RPIL-1.0FSRE RPI-1.5FSRE RPI-2.5FSRE RPI-5.0FSRE RPIH-5.0FSRE
RPIL-1.5FSRE RPI-2.0FSRE RPI-3.0FSRE RPI-6.0FSRE RPIH-6.0FSRE
Features & benefits
87
RPI(H)-FSRE
RPIL-FSRE
(left or right)
Air intake
VRF
GOOD TO
KNOW Filter access without removing the
plenum is only possible with the adapted
Hitachi plenum. The rail-mounted filter
means standard filter holder screens are
not required - still on the same model -
and a choice of intake screen is therefore
available. Fresh air inlet
Standard M1 insulation
–
88
Hitachi Plenums
The plenums are M1 insulated
Plenum design includes filter holder for removing the filter without dismantling the plenum to facilitate maintenance.
Intake diametre
Compatibility Plenum type number (mm) Référence Descriptif
Intake with filter access 2 x Ø200 PIFA-750X197 AIR INTAKE PLENUM INSULATED (Filter acces)
Intake with filter access 3 x Ø200 PIFA-750X240 AIR INTAKE PLENUM INSULATED (Filter acces)
Intake with filter access 3 x Ø200 PIFA-1084X240 AIR INTAKE PLENUM INSULATED (Filter acces)
Intake with filter access 4 x Ø200 PIFA-1474X240 AIR INTAKE PLENUM INSULATED (Filter acces)
Easy static pressure adjustment
89
RPIL-0.8FSRE
100
90
Network curve
External static pressure (Pa)
60
Fan curve
(Fan speed):
High C5=01
Medium C5=00
30
Low C5=02
VRF
360 390 450 480 600
Airflow (m3/h)
GOOD TO
KNOW All settings from the remote control
or CSNET supervision (pressure,
auto restart, resume/command
control, fan stop at setpoint.
90
Max height
197 mm
Advantages
- Reduced installation times in hotels where the main pipework is in the
corridor (no need for pipe bends),
- Easy installation of refrigerant connections with the unit in place,
- Installation possible in a 800 mm wide airlock (filter removal from below in
this case),
- Rear condensate connection: fewer connections and less risk of a leak,
- Simplified seal verification,
- Access to the card for simplified maintenance,
- Settings from the remote control (no need to open the ceiling to access the
unit card),
- The electric box in the RPIL can the remote, so they can be placed in
hotel room air locks while maintaining access to the IU card. 80 cm cable
supplied.
Summary
Condensate pump • • • • •
(can be disconnected)
Rear/below air inlet
(option) • • • •
Filter access
(below/side) • • • • •
Magnetic contacts/
Access card • • • • •
R32/R410A
compatible • • • • •
91
Slim Ducted unit, height 197mm (up to 100Pa available pressure)
Indoor units Unit RPIL-0.4FSRE RPIL-0.6FSRE RPIL-0.8FSRE RPIL-1.0FSRE RPIL-1.5FSRE
Power (adjustable) Hp 0.40 0.60 0.80 1.00 1.30 1.50
Capacity Cooling UTOPIA Prime & IVX kW not available not available 2.00 2.50 3.60
Capacity Heating UTOPIA Prime & IVX kW not available not available 2.20 2.80 4.00
Capacity Cooling SET FREE kW 1.10 1.70 2.20 2.80 3.80 4.00
Capacity Heating SET FREE kW 1.30 1.90 2.50 3.20 4.20 4.80
Absorbed capacity (low speed) kW 0.02 0.02 0.02 0.03 0.03
Sound pressure in Cooling mode (low/medium/ dB(A) 22/23/24 23/25/27 23/25/28 25/29/30
high speed)(1)(3)
Noise capacity (high speed) dB(A) 43 46 47 49
Min. airflow in Cooling mode (low/medium/high m³/h 300/330/360 330/390/438 342/390/462 390/474/528
speed) (SP02)(4)
Rated static pressure (min-max) Pa 15 (0~100) 25 (0~100)
Condensing pump - yes (can be removed to use as a gravity-fed unit)
Max. elevation mm 850
Diameter of pipes (Liq/Gas) inches 1/4 - 1/2
Condensate pipe diameter (out) mm 32
Dimensions (HxWxD) mm 197 x 750 x 600
Weight kg 23
Power supply - 1~ 230V 50Hz
Cable section (EN 60 335-1)(4) mm² 3 x 0.75
Max. current A 5 5 5
VRF
Weight kg 25 30 36
Power supply - 1~ 230V 50Hz
Cable section (EN 60 335-1)(2) mm² 3 x 0.75
Max. current A 5 5 5 5 5
Blower plenum 2 air outlets 3 air outlets 4 air outlets 5 air outlets 6 air outlets Air extraction plenum
Standard
(*510 mm height, - - - - AZEZ8HITST08XL6
4.0-5.0-6.0 registers on two rows)
RPIH-FSRE AZCEZHIPR08XL
(1474 x 340 mm)
Medium - - - - -
Airzone Blueface Zero Airzone Think thermostat Airzone Lite thermostat Webserver Airzone Cloud
thermostat Wired or wireless connection/2.7” Wired or wireless connection: In The Airzone Cloud app, compatible
Wired connection/3.5” touchscreen: screen: Configurable as a general systems with the Blueface thermostat, on your smartphone, tablet, and PC,
Configurable as a general thermostat thermostat or by zone. Low-energy this solution is perfect for quick access offers complete remote control of
or by zone. Eco-adapt and standby device that makes it easy to reduce to essential functions. Its modern the installation; anywhere, anytime.
function for tangible energy saving. energy costs. Stylish and intuitive and fun interface makes it easier to You can control multiple servers at
Control the temperature, mode, and interface. Control the temperature, use, with colors indicating the mode once and up to 32 systems on a single
fan speed. Weekly programming. mode, and fan speed. Access to and temperature of the area. Start/ webserver. All the features of your
weather forecasts (with Airzone Cloud Stop function. Control the setting thermostats are combined on the
webserver login) to anticipate changes temperature in increments of 1°C with cloud:
in temperature. a scope of ±3°C. Control the temperature, weekly
programming, weather forecasts, login
authorization…
Air diffusers
Ventilation connections
High-capacity ducted
Air intake
Refrigeration connections
Hitachi VRF
m.
gra
c dia
ati
em
VRF
h
l sc
ctua
tra
on
n-c
No
Waterproof coating
Draft-proofing
Modular register
Warning possible on clock, detection or
CO2 sensor
Refrigerant connection 3/8-7/8 if L < 15 ml (Not sold by Hitachi.)
between outdoor unit and indoor unit
Auto-regulating configurable register
Fresh airflow from 0 to 30% max
(Not sold by Hitachi.)
Air intake
Mounting hooks
Air filter
Indoor units
846
423
600 600
1.592 1.592
RPI-8.0FSN3E(-f) RPI-16.0FSN3PE(-f)
RPI-10.0FSN3E(-f) RPI-20.0FSN3 PE(-f)
95
VRF
–
96
Wall unit
Fig. 1
PC - AWR
Indoor units
Indoor units Unit RPK- RPK- RPK- RPK- RPK- RPK- RPK- RPK- RPK-
0.4FSR(H)M 0.6FSR(H)M 0.8FSR(H)M 1.0FSR(H)M 1.5FSR(H)M 2.0FSRM 2.5FSRM 3.0FSRM 4.0FSRM
Power (adjustable) Hp 0.40 0.60 0.80 1.00 1.30 1.50 1.8 2.00 2.30 2.50 3.00 4.00
Capacity Cooling UTOPIA Prime & IVX kW not available not available 2.00 2.50 3.60 5.00 5.60 7.10 10.00
Capacity Heating UTOPIA Prime & IVX kW not available not available 2.20 2.80 4.00 5.60 6.30 8.00 11.20
Capacity Cooling SET FREE kW 1.10 1.70 2.20 2.80 4.00 5.60 7.10 8.00 11.20
Capacity Heating SET FREE kW 1.30 1.90 2.50 3.20 4.80 6.30 8.50 9.00 12.50
Noise level in Cooling mode (pressure) (low/ dB(A) 29/30/31/32 29/31/32/35 30/32/35/39 33/36/40/46 31/34/37/40 35/38/42/45 35/40/44/47 39/44/48/51
medium/high speed1/high speed2)(1)(3)
Sound power dB(A) 45-46-48-49 45-47-49-53 47-50-54-58 47-50-53-55 51-54-58-60 51-56-60-63 54-60-64-65
Airflow in Cooling mode (low/medium/high m³/h 360/402/438/450 360/420/450/480 390/420/480/600 450/540/660/840 570/660/780/870 720/840/990/1110 750/930/1050/1200 870/1050/1200/1380
speed1/high speed2) (4)
Dimensions (HxWxD) mm 300 x 790 x 230 300 x 900 x 230 300 x 1100 x 260
Weight kg 9 10 11 14.5 15
Max. current A 5
(1)
Sound pressure is measured under the following conditions: 1 m under the unit, 1 m from the pulse air flap.
(2)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility and current standards.
(3)
Very high-speed access is possible with remote controls PC-ARFP1E and PC-ARH1E.
(4)
Very low speed is available in Thermo-off mode.
Expansion Valve
Reducer
VRF
EV-1.5N1 RPK- 0.4~1.5FSRHM
PC-ARFG-E
You can have multiple contacts with the connector PCC-1A: progress report, error report, thermostat control, remote “Start/Stop”.
Console
Fig. 1 Fig. 2
Indoor units
RPFI-2.0FSN2E RPF-2.0FSN2E
RPFI-1.0FSN2E RPFI-1.5FSN2E RPFI-2.5FSN2E RPF-1.0FSN2E RPF-1.5FSN2E RPF-2.5FSN2E
Console 99
Capacity Cooling UTOPIA Prime & IVX kW 2.50 3.60 5.00 5.60
Capacity Heating UTOPIA Prime & IVX kW 2.80 4.00 5.60 6.30
Capacity Cooling SET FREE kW 2.20 2.80 3.80 4.00 5.20 5.60 6.70 7.10
Capacity Heating SET FREE kW 2.50 3.20 4.20 4.80 5.60 6.30 7.50 8.50
Sound level in Cooling mode (pressure) (low/medium/high speed) dB(A) 29/32/35 31/35/38 32/36/39 34/38/42
(1)(3)
Diameter of pipes (Liq/Gas) inches 1/4 - 1/2 1/4 - 5/8 3/8 - 5/8
Dimensions (HxWxD) mm 630 x 1045 x 220 630 x 1170 x 220 630 x 1420 x 220
Weight kg 25 28 33 34
Maximum current A 5
Capacity Cooling UTOPIA Prime & IVX kW 2.50 3.60 5.00 5.60
Capacity Heating UTOPIA Prime & IVX kW 2.80 4.00 5.60 6.30
Capacity Cooling SET FREE kW 2.20 2.80 3.80 4.00 5.20 5.60 6.70 7.10
Capacity Heating SET FREE kW 2.50 3.20 4.20 4.80 5.60 6.30 7.50 8.50
Sound pressure in Cooling mode (pressure) (low/medium/high
dB(A) 29/32/35 31/35/38 32/36/39 34/38/42
speed) (1)
Sound power dB(A) 57 60
Airflow in Cooling mode (low/medium/high speed) m³/h 360/420/510 540/600/720 660 x 840 x 960
Diameter of pipes (Liq/Gas) inches 1/4 - 1/2 1/4 - 5/8 3/8 x 5/8
Dimensions (HxWxD) mm 620 x 848 x 220 620 x 973 x 220 620 x 1223 x 220
Weight kg 19 23 27 28
Maximum current A 5
VRF
(1)
Sound levels (pressure) are measured in an anechoic chamber at 1 m in front of the unit and at 1 m from the floor.
(2)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility.
(3)
High-speed access is possible with remote controls PC-ARFP1E and PC-ARH1E.
You can have multiple contacts with the connector PCC-1A: progress report, error report, thermostat control, remote “Start/Stop”.
Ceiling unit
Indoor units
RPC-4.0FSR
RPC-1.5FSR RPC-2.5FSR RPC-5.0FSR
RPC-2.0FSR RPC-3.0FSR RPC-6.0FSR
Ceiling unit 101
Indoor units Unit RPC-1.5FSR RPC-2.0FSR RPC-2.5FSR RPC-3.0FSR RPC-4.0FSR RPC-5.0FSR RPC-6.0FSR
Power (adjustable) Hp 1.30 1.50 1.80 2.00 2.30 2.50 3.00 4.00 5.00 6.00
Capacity Cooling UTOPIA Prime & IVX kW 3.60 5.00 5.60 7.10 10.00 12.50 14.00
Capacity Heating UTOPIA Prime & IVX kW 4.00 5.60 6.30 8.00 11.20 14.00 16.00
Capacity Cooling SET FREE kW 3.80 4.00 5.20 5.60 6.70 7.10 8.00 11.20 14.00 16.00
Capacity Heating SET FREE kW 4.20 4.80 5.60 6.30 7.50 8.50 9.00 12.50 16.00 18.00
Condensing pump - No
Dimensions (HxWxD) mm 235 x 960 x 690 235 x 1270 x 690 235 x 1580 x 690
Weight kg 26 27 35 41
Maximum current A 5
(1)
Sound levels (pressure) are measured in an anechoic chamber at 1 m under the unit, 1 m from the pulse air flap.
(2)
Data shown is for indication purposes only. It is the installer’s responsibility to ensure that these Cable sections meet the needs of the facility.
(3)
High-speed access is possible with remote controls PC-ARFP1E and PC-ARH1E.
(4)
Very low speed is available in Thermo-off mode.
You can have multiple contacts with the connector PCC-1A: progress report, error report, thermostat control, remote “Start/Stop”.
VRF
Remote sensor Infrared receiver Multi-tenant card
THM-R2AE PC-ALHP1 (integrated)/PC-ALHZ1 (external) PC-AMTB
Setup example
Low-Temperature
hydraulic module
Indoor units
CH box
(optional)
Outdoor
unit Heating mode
VRF Sigma
Decoupling tank
(optional)
CH box
(optional)
Indoor units
Net weight kg 35 50 62
Diameter of cooling pipes (Liq - Gas) inches 3/8” - 5/8” 3/8” - 5/8” 3/8” - 7/8”
* Important: simultaneous operation can never be higher than 100% in heat pump mode.
Simultaneous operation in the same mode can never exceed 100% for a VRF system in heat recovery mode.
(1)
The maximum number of indoor units is the recommended quantity of indoor units for every size of outdoor unit. For more information, please refer to the technical catalog of the outdoor unit.
(2)
See Section 9.5.2.2 “Function of DIP switches and dial switches” in the technical catalog for more information on Pin 3 of the DSW8 with a connection rate of > 180%.
You can have multiple contacts with the connector PCC-1A: progress report, error report, thermostat control, remote “Start/Stop”.
VRF
ON/OFF wireless thermostat Controller enclosure Temperature sensors
ATW-RTU-04 ATWFCP-01 ATW-2OS-02
ATW-ITS-01
ATW-WTS-02Y
–
104
Hydro Free
High-Temperature
Heating mode only
CH box
Outdoor unit
VRF Sigma
Indoor units
751
(802)
623
600
RWHT-5.0VNF1E
Hydro Free High-Temperature 105
Depth mm 623
Refrigerant - R134A
Compressor - Scroll
You can have multiple contacts with the connector PCC-1A : progress report, error report, thermostat control, remote “Start/Stop”.
VRF
Compatible controls and accessories
Controller ON/OFF wireless thermostat Temperature sensors
PC-ARFWE ATW-RTU-04 ATW-2OS-02
ATW-ITS-01
ATW-WTS-02Y
Hitachi wants to bring more and more comfort to its
106
Maneag the
Utopia Prime,
IVX and VRF
instial ons
VRF
Simple wired
PC-ARH1E
Touchscreen
centralized Manage up to 160 indoor units:
-P SC-A32MN > up to 32 units of 16 indoor units, max. 160,
PSC-A32MN -P SC-A64GT > up to 64 units of 16 indoor units, max. 160,
PSC-A64GT - Up to 8 touch commands per H-Link bus.
- 5” (PSC-A32MN) and 8.5” (PSC-A64GT) color,
- Up to 100 programmable alarms,
- Available contacts: start/stop, error report, function report,
- Offload function,
- On the PSC-6RAD, max. 16 units allowed.
Ideal for monitoring small and medium-sized systems.
109
Functions - Version 2.0 of the CSNET software (managing the Yutaki, server - Same features as CSNET - Monitor units VRF, IVx, and Utopia
room function, pulse meters on the CSNET Lite, electricity and Manager, applied to small (HLINK unit)
water metering for third-party systems, etc.) or medium-sized systems - Simple unit control with Web or
- VRF + air/water heat pump unit control (H-Link systems) - Manage up to 64 indoor mobile applications
- Multi-tenant access with specific rights/privileges for different units - Alarm notifications and alarm log
functions or indoor unit control available for remote maintenance
- Advanced control functions (Comfort, Interlock...) - Perfect solution for small public
- Multi-tenant installations, flexibility for office applications applications and business needing
- Energy metering for VRF units – third-party systems basic control functions
- Use of dry input/output contacts on indoor units or CSNET Lite
- Connection to the BMS system (Modbus, BACnet, or KNX)
VRF
Medium and large-size systems Small and medium-size Small and large-size systems
Applications
systems
BMS gateways
- Up to 16/64 indoor units per - Up to 16/64 indoor units per - Up to 16/64 indoor units per -Up to 32 (version E(B))/64
Gateway, Gateway, Gateway, (version E(A)) indoor units per
- Optional function - Fast integration: KNX-certified. - Fast integration: BACnet- gateway
management, view outdoor - Easy maintenance: USB certified, direct H-Link
unit settings. port available, function and communication – BACnet.
communication LEDs. - Easy maintenance: USB
- KNX gateways compatible with port available, function and
CSNET Manager. communication LEDs.
- BACNET gateway compatible
with CSNET Manager.
Individual remote controls Selection guide
110
Auto Heating/Cooling mode (best used with 3-pipe VRFs) (best used with VRF 3 pipes) (best used with VRF 3 pipes)
Dehumidification mode
Control selection (19°C to 30°C in Cooling mode/17°C (19°C to 30°C in Cooling mode/17°C (19°C to 30°C in Cooling mode/17°C
to 30°C in Heating mode) to 30°C in Heating mode) to 30°C in Heating mode)
Adjust control to +/-0.5°C -
Regulating the fan speed (up to 5 according to the indoor (up to 5 according to the indoor (up to 5 according to the indoor
unit type) unit type) unit type)
ECO mode - -
Hotel mode - -
VRF
Comfort
Horizontal airflow
Motion sensor
The number of people
present increases
Auto swing
Motion sensor
CrowdSense: : combined with the indoor unit FloorSense and FeetWarm: use the indoor unit
motion sensor, detects the number of people radiant sensor to analyze and limit stratification.
present to anticipate capacity requirements to These functions adjust the ventilation blades
AirFlowControl: : enables the user to select prevent overheating. to ensure uniform temperature throughout the
direct or indirect blowing on occupants. room.
Auto Save
Energy savings
- ECO mode: 3 levels of energy savings available, applied
permanently or based on a weekly program,
- Auto-Save : stops indoor unit operation if the room is unoccupied,
- Hotel mode: Control based on occupant presence (key card
contact).
Centralized commands
113
Selection guide
Model airCloud Pro PSC-A32MN PSC-A64GT CSNET Lite CSNET Manager 2
Cloud access - - - -
Web application - -
Mobile app - - - -
Connectivity 4G connectivity - - - - -
Multi-user management - -
User and site User accounts with limited access to indoor units/ - - -
management functions
Multi-site management - - - -
Installation dashboard - -
Weekly programming - - - -
Basic functions
Annual programming - - -
VRF
Reset filter sign - -
Alarm log
Data archive - - -
Electrical consumption readings for Hitachi indoor unit (Estimation without - - via additional meter via additional meter
Advanced features meter)
Consumption readings Electrical third-party equipment - - - via additional meter via additional meter
Interlock - - -
Alarm notifications - -
Input/output switches -
BMS connection - - -
Centralized Touchscreen commands
114
Selection guide
Suitable for different sizes of facilities for faster monitoring, setup, and maintenance.
PSC-A32MN PSC-A64GT
Manage up to 32 units of 16 indoor units, max. 160. Manage up to 64 groups of 16 indoor units, max. 160.
5” color touchscreen. 8.5” color touchscreen.
115
Manage up to 32 units of 16 indoor units, max Manage up to 64 units of 16 indoor units, max
160 160
Up to 8 centralized controllers per H-Link bus Up to 8 centralized controllers per H-Link bus
Language (French)
Dehumidification selection
Main functions
Choosing the fan speed per indoor unit/group or block
Adjust the position of the fan blower blades per indoor unit/group or block
Timer -
VRF
ECO mode -
Lock remote control apart form the Start/Stop button per indoor unit/group or block
Limit and lock setting ranges (in Heating mode/in Cooling mode) per indoor unit/unit or block – on PSC-A32MN only
Non-freeze function -
Offload (reduce the current peaks of the outdoor group following a weekly schedule or using an external
signal (contact on the central controller)
Error code log (up to 100: show error code, date and time of the failure, unit(s) affected
You’re in control
Intuitive simplicity
airCloud Pro is designed to make it easier for you. This open- IT data of the Gateway HC–IOT GW
access mobile app makes it easier than ever to manage your
Dimensions (W x H x D) 138 x 200 x 41 mm
air-conditioning systems.
Net weight 540 g
4
The airCloud gateway makes installation much easier.
Central control
Control either the entire VRF system or specific zones all at the touch of Just connect to airCloud via the Ethernet network and pair your
VRF systems by scanning the QR code. The indoor units are
a button.
detected automatically and deliver the best installation process
Easy problem-solving by making general site and zone setup quicker than ever.
Clear error code log, brief summary of the problem, and filter to be
1
cleaned.
Smartphone alerts
To report any serious malfunction.
Flexible user management
Add unlimited users and customized access restrictions. + data security
+
- The highest standards: Protocol TLS v1.2, HTTPS 2038 encryption
- Limited number of personal information requested:
You only need your name, email address, and phone number
to log in
Save more energy - Regularly updated and enhanced with new features,
Energy consumption data airCloud Pro ensures you’re always up to date.
View your electricity consumption in simple graphs to monitor the high-
2
demand units in your system (available in 2021).
Intuitive planning How airCloud Pro works
Plan service visits around your working day and exceptions
such as holidays.
Lock control devices separately
Block any inappropriate use by occupants.
Ethernet network
3
Easily adjust the temperature, fan speed, and operating modes for H-LINK
complete comfort and an ideal ambient climate throughout the
building.
From the Internet airCloud To your VRF
A built-in weather forecaster helps you define the conditions or mobile app interface system or Utopia
most suited to different indoor spaces throughout the year. Prime
Compatible with old and new Hitachi variable refrigerant flow systems (1)
Go to: aircloudproapp.com Check the compatibility of your VRF system with your Hitachi Cooling & Heating representative.
(1)
117
features
airCloud Pro
gateway features Max. amount of indoor units per user interface Unlimited
(with multiple gateways)
Cloud access
Web application
Mobile app
Connectivity 4G connectivity -
Local setup access or emergency access if server access is down With limited features
Multi-user management
User and site management User accounts with limited access to indoor units/functions -
Multi-site management
Start/Stop
Heating/Cooling mode
Setpoint temp.
VRF
Basic indoor unit control
Fan speed
Weekly programming
Alarm log
Alarm notifications
English
French
German
Languages App languages
Italian
Portuguese
Spanish
Centralized CSNet commands
118
Selection guide
The CSNET range comes in 2 versions: a flexible WEB version and a user-friendly touch
screen version. This range is ideal for projects of all sizes from the small to large public jobs.
It offers the widest range of functions on the market, all integral to the unit without the
need for optional add-ons. Installation is simple and quick.
The intuitive configuration wizard ensures commissioning is a breeze.
New features:
- Next-generation touchscreen for a more enjoyable user experience.
- New, more intuitive responsive user interface that offers the same features on
Accessories any screen.
Wall support - Ref.: WALL SUPPORT 2 - Wizard function for easier, faster setup.
Base - Ref.: STAND SUPPORT
- Master/slave operation of indoor units: more electrical wiring needed for a
more flexible and less expensive installation.
Ideal for managing large installations with maximum comfort for operators
and their maintenance teams.
For medium and large installations (web display or HDMI screen provided by the client)
New features:
Accessory - More flexible installation: Ethernet port, 2 USB ports, HDMI port.
DIN Rail support
Ideal for managing large facilities.
VRF
With this CSNET range, you can manage 1 The CSNET Manager 2 T10/2 T15 range,
to 64 indoor units on the interface and up to includes 2 screens, 10” and 15”.
1024 indoor units, locally or remotely on the The system is managed on two H-Link
WEB. interfaces of your choice, HC-A64NET or
CSNET Lite, capable of managing up to 64
CSNET Manager 2 is a management and indoor units. CSNET Manager 2 can manage
monitoring interface for Hitachi heating and up to 16 H-Link interfaces.
air-conditioning systems.
It features a new touchscreen technology For installation extensions, CSNET Manager
as well as a responsive display, for an 2 is also compatible with the CSNET Web
improved user experience. box (limited for certain options).
Model
+ HC-A64NET
Web server
Compatible BMS MODBUS interface included as standard KNX - BACNET via dedicated
gateways
Offload
Set the optional functions of indoor units with up-to-date HLINK interfaces (CSNET Lite v2.0 or HC-A64NET
v2.0)
Master/Slave management
Set Back (non-freeze): reduces heating or Cooling mode (e.g. 23 hours to 5 hours)
Offload
Advanced
management tool
WEB version
Standalone WEB version
CSNET Manager 2 SL
CSNET LITE
Up to 1,024 Up to 64
Smartphone Tablet PC equipped with a Web Smartphone Tablet PC equipped with a Web
browser browser
Unlimited Unlimited
Menu
-
An intuitive dashboard:
VRF
3 available formats
(limited actions)
(image format) -
Dashboard
6 months 6 months
List view
CSNET Manager 2
122
(400V/3/50Hz)
Power supply
SIEMENS L2
This standard feature allows you to 7KM L3
measure, record, and display the energy PAC3200
N
consumption of all or some of the indoor
units and outdoor units managed by CSNET.
This consumption is shown in kWh or in
Local Ethernet
Euros if the user enters their hourly energy network
SOCOMEC
cost. Countis
E27 & E28
Embedded safety:
Interlock function
The embedded interlock function, standard in all CSNET interfaces, allows
a multitude of interlock scenarios to be easily programmed, providing
automated safety in more industrial applications.
New feature:
Server room management feature in CSNET Manager version 2.0
123
An alarm log is automatically generated by CSNET Manager 2 as soon as the Address discomfort issues reported by customers and resolve them remotely
first defect appears. This log can be exported at any time. by changing operating parameters.
VRF
GENTLE COOL This intelligent on-board programming function, included as standard in
all CSNET interfaces, can combine several input signals triggering actions
This feature meets the comfort levels expected by every user in Cooling according to IFTTT logic.
mode by giving them the option to adjust their fan blower temperature.
HC-A64NET
CSNET
LITE H-Link
H-Link
Unit 1
Site 1
Local
Ethernet
Local network
Ethernet
network
H-Link
WiFi network WiFi network
Unit 2
Site 1: Access to the local network with ascreenless interface. Site 2: Access to the local network with ascreenless interface.
Access from a PC, smartphone connected to the same local network or Access from a PC, smartphone connected to the same local network or
from the Internet. from the Internet.
An example of the setup of 2 separate sites equipped with VRF, with centralized
CSNET control and monitored remotely
HC-A64NET
H-Link
@
network
WiFi
network
Remote monitoring with a
H-Link touchscreen interface:
touchscreen control.
CSNET Access from a computer, a
LITE
Site 1 smartphone on the same local
network, or from the internet.
125
IP X.Y.Z.01
Electrical
protection
IP X.Y.Z.02
IP X.Y.Z.03
Electrical
protection
IP X.Y.Z.04
VRF
For an installation with one refrigerant circuit and energy meter
Example with a CSNET Lite
IP X.Y.Z.01
IP X.Y.Z.02
126
IP
X.Y.Z.01
IP X.Y.Z.02
RJ 45
H-LINK
Inter-unit
link Cycle 00 Cycle 00 Cycle 00
Unit 01 Unit 02 Unit 03
Communication gateways
Hitachi offers a full range of communication gateways with
most open protocols on the market.
H-Link
BMS
Communication gateway
MODBUS or KNX or BACNET or LONWORKS
VRF
Economic BMS solution: perfect for medium and small public sector buildings.
KNX protocol
BACnet®/IP protocol
The widely used BACnet/IP was designed to allow the protocol to use TCP/IP HI-AC-BAC-16 (16 indoor units)
networks.
New certified interfaces directly manage 16 or 64 units each. HI-AC-BAC-64 (64 indoor units)
BMS solution: perfect for large public sector buildings.
LONWORKS protocol
ai-r on
c ditioning
and ventitila on
VRF
AIR FILTERING
air-conditioning
130
DX air curtains
Double-flow ventilation
DX kit
VRF
–
132
DX air curtains
1.140 1.380
600
300 370 370
1000 1000 792 950 950
1500 1500
2000 2000
2500 2500
RAS-4H(V)NC2E RAS-8HNCE
Wall curtain Recessed curtain RAS-3HVNC1 RAS-6H(V)NC2E RAS-10HNCE
DX air curtains 133
Linea M DXH compatible with Hitachi, height of up to 3 m, 230V~ AZR M DXH compatible with Hitachi, height of up to 3 m, 230V~ Split installation: Compatible outdoor units (requires
one remote control PC-ARFP1E per curtains)
Power Air flow Voltage Weight Power Air flow Voltage Weight Utopia Prime/Micro VRF IVX
rate rate
Part number Part number
kW m /h
3
(V) kg kW m /h
3
(V) kg Comfort
Linea G DXH compatible with Hitachi, height of up to 3.5 m, 230V~ AZR M DXH compatible with Hitachi, height of up to 3.5 m, 230V~
Power Air flow Voltage Weight Power Air flow Voltage Weight Utopia Prime/Micro VRF IVX
rate rate
Part number Part number
kW m3/h (V) kg kW m3/h (V) kg Comfort
Part number Height Length Depth Part number Height Length Depth
VRF
–
134
Double-flow ventilation
With energy recovery
Authorized in category
5 ERP only
KPI
Max static pressure (nominal airflow) Pa 240 210 120 190 200 170
Dimensions (HxWxD) mm 270 x 900 x 750 330 x 1130 x 920 385 x 1210 x 1015 385 x 1600 x 1295 525 x 1800 x 1130 525 x 1800 x 1430
Weight kg 34 46 51 79 97 106
VRF
Compatible controls and accessories (see the tab VRF TWIN Controls p.243)
Wired remote control weekly
PC-ARFG-E
*These units are not suitable for installation ERPs in the first group.
–
136
Authorized in category
5 ERP only
KPI active
Rated cooling capacity (recovery) kW 5,32 (of which is recovered: 1.81) 7,96 (of which is recovered: 2.94) 10,83 (of which is recovered: 3.73)
Rated heating capacity (recovery) kW 6,92 (of which is recovered: 2.12) 9,79 (of which is recovered: 3.49) 12,93 (of which is recovered: 4.43)
Dimensions (H x W x L) mm 330 x 1435 x 920 385 x 1513 x 1015 385 x 1904 x 1295
Weight kg 62 69 100
RAS-3HVNC1
Compatibility OU 1x1 - - -
(Available while stocks last)
Installation of active KPI with VRF SIGMA, Set free mini, Utopia Prime
- Mixed operation (double flow ventilation active KPI and air/air indoor units),
- The connection rate is: max 30% active KPI and 70% air/air indoor unit.
VRF
(1) An electrical resistance and additional THM4 air intake sensor (optional accessory installed before the electrical resistance) must be installed when the temperature drops below -5ºC(DB)
Compatible controls and accessories (see the tab VRF TWIN Controls p.243)
Wired remote control weekly
PC-ARFG-E
- These units are not suitable for installation in ERPs of the first group
–
138
DX kit
Air-conditioning unit.
Not included:
- Remote control PC-ARFG-E.
- PCC-1A connectors.
Important
- Do not stop ventilation through the DX battery while defrosting the outdoor units. You can add an electrical element to avoid blowing cooling air (not
managed or sold by Hitachi).
- A 12Vcc relay (not sold by Hitachi) to serve the electrical element must be provided.
- A 12 Vcc relay (not sold by Hitachi) to select the heating/cooling mode is required in the event the AHU has inputs to select the heating/cooling mode,
- If the AHU has outputs for managing the mode (heating/heating), these must connect to the inputs (dry contact) of the outdoor unit.
431 1.380
291
103 127 370
341 950
199
RAS-4XH(V)NP1E
RAS-5XH(V)NP1E
EXV-4.0E2 RAS-6XH(V)NP1E
EXV-5.0E2 EXV-8.0E2 RAS-8XHNPE
EXV-6.0E2 EXV-10.0E2 RAS-10XHNPE
139
Below these values, provide an electrical element or a heat recovery system upstream of the DX battery.
Control based on air intake only. Temperature of the fan blower, return, etc.
Compatible with groups IVX Prime, Utopia Prime and FREE Mini and SIGMA sets.
- Control based on air intake depending on air intake only.
DX KIT
DX AHU
Group
communi- Control
VRF
cation
interface
Power supply
Sensor 1
THM1
Expansion Sensor 2
PC-ARFP1E Valve AIR THM2
DX battery
Liquid
Gas
Sensor
H-LINK bus THM
3 and 5
DX KIT Modular operation
Group
with up to 5 groups
communi- THM 3 and (125kW)
Control 5 sensor
cation
interface
Power supply
Liquid
Gas
Optimal defrosting
- Installation with 2 or 3 units: only one group in defrosting mode.
- Installation with 4 or 5 groups: 2 groups in defrosting mode and 3 units in use.
140
DX kit
Part number of DX KIT Unit EXV-3.0E2 EXV-4.0E2 EXV-5.0E2 EXV-6.0E2 EXV-8.0E2 EXV-10.0E2
Capacity
kW 7.1 10.00 12.50 14.00 20.00 25.00
Cooling DX Battery
Weight kg 3
cooling 8 10 11.2
EXV-4.0E2 RAS-4XH(V)NP1E 1.51 2.37 4.56 1200 2160
Heating 9 11.2 12.5
cooling 10 12.5 14
EXV-5.0E2 RAS-5XH(V)NP1E 1.92 2.37 4.56 1380 2490
Heating 11.2 14 16
cooling 11.2 14 16
EXV-6.0E2 RAS-6XH(V)NP1E 1.92 2.92 5.11 1500 2550
Heating 12.8 16 18
cooling 16 20 22.4
EXV-8.0E2 RAS-8XHNPE 2.92 3.89 6.93 3540 4680
Heating 17.9 22.4 25
cooling 20 25 28
EXV-10.0E2 RAS-10XHNPE 3.89 4.76 10.73 4080 5340
Heating 22.4 28 31.5
The capacity of the heat exchanger must match the specified rated capacity of each DX KIT under the following temperature conditions.
Failure to comply with the heat exchanger’s capacity can result in a system malfunction. Data applies under the following conditions:
Performance, cooling
10.0 (4.5-11.2) 12.5 (5.7-14.0) 14.0 (6.0-16.0) 20.0 (8.0-22.4) 25.0 (10.0-28.0)
Capacity, cooling (min-max) kW
(4.50 - 11.20) (5.70 - 14.00) (6.00 - 16.00) (8.00 - 22.40) (10.00 - 28.00)
Performance, heating
11.2 (5.0-14.0) 14.0 (5.0-18.0) 16.0 (5.0-20.0) 22.4 (6.3-28.0) 28.0 (8.0-35.0)
Capacity Heating (min-max) kW
(5.00 - 14.00) (5.00 - 18.00) (5.00 - 20.00) (6.30 - 28.00) (8.00 - 35.00)
Technical features
Noise level in Cooling mode (night-time dB(A) 47 (43) 48 (44) 48 (45) 57 (55) 58 (56)
pressure)
Additional load Kg calculated based on the method indicated in the installation technical documentation(1)
VRF
Reducer installation - 5 m MAX of DX battery
Refrigerant - R410A
Technical features
(1) The values of “Additional refrigerant refill needed” are determined on a case by case basis. To find out these values, see the “DX interface refrigerant refill and max. pipe lengths” section listed in the Technical Catalog. An
Excel file is available to make this calculation (available from your HITACHI contact).
Compatible controls and accessories (see the tab VRF TWIN Controls p.243)
Wired remote control weekly Adjustable input/output contact con-
PC-ARFG-E nections
PCC-1A
Find out the meaning
142
of our icons
The different icons are designed to facilitate your choice through an immediate
display of the different technologies applied to each single product.
Free cooling Adaptable static pressure CO2 sensor available Hitachi exclusive
Free cooling with the Head adaptable to use Ventilation controlled by CO2 Hitachi exclusive solution.
contribution of external air. with ducts of different lengths. sensor for good air quality.
VRF
Compatible with Independent control Independent control HIGH speed H
all indoor units Each indoor unit can of the flaps Extra super high
Complete flexibility individually regulate its Allows individual adjustment speed for rooms of
connection with Hitachi own temperature. of the angle of incidence of great height.
outdoor units. the deflectors.
hitachiaircon.com