0% found this document useful (0 votes)
35 views1 page

Third Floor Ceiling Layout Plan

The document appears to be a detailed layout plan for a construction project, specifically focusing on piping and electrical connections. It includes specifications for various pipe sizes, types, and connection points, as well as references to ceiling manholes and isolation valves. The layout is organized by sections labeled with letters and numbers, indicating different areas of the project site.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views1 page

Third Floor Ceiling Layout Plan

The document appears to be a detailed layout plan for a construction project, specifically focusing on piping and electrical connections. It includes specifications for various pipe sizes, types, and connection points, as well as references to ceiling manholes and isolation valves. The layout is organized by sections labeled with letters and numbers, indicating different areas of the project site.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 3' 4 4' 5 6 7 9

63MMØ CWL(P) CAP


(PIPE DN.) BANK1 50MMØ NPCWLAC 50MMØ NPCWLAC
LOOP CONNECTION LOOP CONNECTION
A LVSG1
X'FORMER1
2.0MVA
MVSG1 A
MTS
TIE CB
2"Ø GV (P)
FOR MAKE UP WATER
1
2 ''Ø GV/HB
X'FORMER2
MVSG2
CAP LVSG2 2.0MVA
BANK2
SE SE
1 41 ''Ø GV/WM (P)
75MMØ CWR (P) 1 W/ STUBOUT (TYP.)
FOR COOLING TOWER 2 ''Ø GV/HB
2''Ø GV/WM (NP)

40Ø CWLAC (P)


75MMØ CWR (NP)
FOR COOLING TOWER
25Ø PCWLAC 32Ø PCWLAC
20Ø CWLAC (P)
B

FUTURE PARKING
1 1
2 ''Ø GV/HB 2 ''Ø GV/HB 1
2 ''Ø GV/HB 3000 CH:+
1''Ø GV (NP) B'
2-2 12 ''Ø GV/WM (P/NP) 1 21''Ø GV (NP)
3000 CH:+
W/ STUBOUT (TYP.) 1

BLDG
1 2 ''Ø GV (NP)
20MMØ CWL (P)
1 21 ''Ø GV/WM (P) (PIPE UP)
32Ø CWLAC (P) 1''Ø GV/WM (P)
1''Ø GV (P) W/ STUBOUT
1
2 ''Ø GV (P)
1''Ø GV (P) 2-4''Ø ISOLATION GV (P) 1
1''Ø GV (P) W/ 0.60M X 0.60M OPEN 2 ''Ø GV/WM (P)
C CEILING MANHOLE
ABOVE
FLOOR MOUNTED
(TYP. AT KIOSKS)
25Ø CWL
(PIPE DN) 25MMØ CWL
(UNDER SLAB) 0.60M X 0.60M CEILING MANHOLE
C'
3
4 ''Ø GV 4200 CH:+
- 32Ø CWLAC (P) 1''Ø GV/WM (P)
4200 CH:+
- W/ STUBOUT
1''Ø GV (P)
D CH:+ 4000
- CH:+ 4100
-

1
2 ''Ø
CH:+ 4000
- GV (P)
CH:+ 4000
1''Ø GV (P)-
CH:+ 4000
- CH:+ 4000
-
CH:+ 4000
1 -
- 20MMØ CWL (P)
CH:+ 4100 2 ''Ø
GV (P)
(PIPE UP) 1 21''Ø GV/WM(P)
CH:+ 4000
- CH:+ 4000
-
CH:+ 4000
50MMØ NPCWLAC
- CH:+ 3900
2''Ø GV/WM
CH:+ 4000 (NP)
- CH:+ 4000
- 32Ø CWLAC (P)
-
LOOP CONNECTION CH:+ 4000
- 1''Ø GV/WM (P)
W/ STUBOUT
CH:+ 4000
-
1''Ø GV/WM (P)
D'
CH:+ 4200
-
W/ STUBOUT
PT-16
1 21 ''Ø GV (NP)
E 1''Ø GV (NP)
1 21 ''Ø GV (NP)
PT-02
E' 1''Ø GV/WM (P)
J
CB #13
W/ STUBOUT 1
2 ''Ø GV/HB (P)
PT-02
2''Ø GV/WM (NP) CH:+ 4000
- 20Ø CWLAC
121 ''Ø GV/WM (P) CH:+ 4200
-
F PT-02 50MMØ NPCWLAC 4''Ø ISOLATION GV (P)
W/ 0.60M X 0.60M
F
LOOP CONNECTION
CF - 4 CEILING MANHOLE
20MMØ CWL (P) 1 50MMØ NPCWLAC
2 ''Ø GV (P) 1''Ø GV (NP) LOOP CH:CONNECTION
PIPERFI
UP #163
5.5 0 M.
20MMØ CWL (P)
1''Ø GV (P) 121 ''Ø GV (NP) PIPE UP
1''Ø GV (P) 1''Ø GV/WM (P)
1
2
PT-15
''Ø GV (P)
121 ''Ø GV (NP)
W/ STUBOUT F'
CH: 5.5 0 M. 1''Ø GV/WM (P)
PT-02
63MMØ CWLAC (P) W/ STUBOUT
OPEN
ABOVE
ARE A :
F"
+- 190 .00 SQM.
CH:4.00M
1
''Ø GV/WM (P) CF - 4
0.60M X 0.60M CEILING MANHOLE
2
112 ''Ø GV (NP) W/ STUBOUT
PT-02 PT-02 PT-02 20MMØ CWL (P)
PT-02 CH:+ 4000
-
PIPE UP

75Ø CWLAC (NP)


CH:+ 4200
-
G G
PE PE

N
IO
4''Ø ISOLATION GV (P)

CT
W/ 0.60M X 0.60M 1''Ø GV/WM (P) 1''Ø GV/WM (P)

NE
20MMØ CWL (P) CEILING MANHOLE W/ STUBOUT W/ STUBOUT

N
CO
PIPE UP
20MMØ CWL (P)

P
OO
(PIPE DN.)

)L
(P
C
LA
W
G'

C
Ø
1

M
CH:+ 4000
2 ''Ø GV/WM (P)
-

0M
20MMØ CWL (P) 1''Ø GV/WM (P) CH:+ 4200
- FLOOR MOUNTED

11
PIPE UP W/ STUBOUT (TYP AT KIOSKS)
1''Ø GV
OPEN
H 32Ø CWL
ABOVE H
CH:+ 4100
-

CH:+ 4000
-
CH:+ 4100
-

3
4 ''Ø GV
CH:+ 4000
-
CH:+ 4200
-

(PIPE DN.)
1''Ø GV/WM (P)
W/ STUBOUT 0.60M X 0.60M CEILING MANHOLE
25MMØ CWL
CH:+ 4200
- (UNDER SLAB)
OPEN OPEN

(UNDER SLAB)
CH:+ 4050
-

5MMØ CWL
CH:+ 4200
-
ABOVE ABOVE
CH:+ 4000
-
1
2 ''Ø GV/WM (P)
CH:+ 4200
1 -
2 ''Ø GV/WM (P)
FLOOR MOUNTED FLOOR MOUNTED
(TYPICAL) CH:+ 4100
- CH:+ 4200
- (TYP. AT KIOSKS) 20MMØ CWL (P)
CH:+ 4000 32Ø CWL PIPE UP
-
(PIPE DN.)
J 25MMØ CWL J
20MMØ CWL (P) (UNDER SLAB)

320Ø CWLAC
PE PE
PIPE UP 1''Ø GV
1''Ø GV/WM (P)
W/ STUBOUT
1
2 ''Ø GV/HB

320Ø CWLAC
25Ø CWLAC
1''Ø GV/WM (P) 1''Ø GV/WM (P) 1''Ø GV/WM (P)
W/ STUBOUT W/ STUBOUT W/ STUBOUT

R UG
K 1
2 ''Ø GV/HB
1
2''Ø GV/HB
110MMØ CWLAC (P) LOOP CONNECTION
K
1
2 ''Ø GV/WM (P)
0.50M X 1.00M CEILING MANHOLE
2-4''Ø ISOLATION GV (P)
W/ 0.60M X 0.60M
CEILING MANHOLE
RFI 42
1 2 3 4 5 6 7 8 9
2-4''Ø ISOLATION GV (P)
W/ 0.60M X 0.60M
K 1
2''Ø GV/HB
100

CEILING MANHOLE
Reviewed By Consultant
A
B
C
D
Signature: Date:
0.50M X 1.00M Rev. DESCRIPTION Date Drawn
CEILING MANHOLE
Client :
Project Name :
Robinson Place
Pagadian
3 4
Main Contractor :
Riezl Landcare &
Construction
Drawing Title :
INSTALLED PPR THIRD FLOOR CEILING
PROPOSED CEILING MANHOLE - -
Size
THIRD FLOOR RCP LAYOUT Drawing No. :
- -
Rev.