36.
24
11.24 7.87 7.87 9.26
0.60
0.12
WP
WP
WP
6.82
6
1DP1
5.24 WP WP
ROOFDECK
7 10.4M
1DP1
WP
DN
DN
2.62
WP WP WP
PLANTBOX PLANTBOX PLANTBOX
WP 1.98
6.65 6.65
1.44
1.98
4.78
LEGEND
-LED DOWN LIGHT/PENDANT LIGHT, 5W
-CEILING MOUNTED LAMP, 24W
WP
25.42 -WALL MOUNTED LAMP, 15W
ROOFDECK -T5 LED LAMP, 20W
10.4M
6.65 6.65
WP -LED STRIP LIGHT
27.01 -EMERGENCY LIGHT
S1 -ONE GANG SWITCH
S 2bc -TWO GANG SWITCH, LETTER INDICATES
LIGHT CONTROLLED
S 3def -THREE GANG SWITCH, LETTER INDICATES
LIGHT CONTROLLED
S 3w i -THREE WAY SWITCH, LETTER INDICATES
LIGHT CONTROLLED
S 4w i -FOUR WAY SWITCH, LETTER INDICATES
LIGHT CONTROLLED
-CONVENIENCE OUTLET
ACU
-AIR CONDITIONING UNIT OUTLET
Ref
-REFRIGERATOR OUTLET
-RANGE OUTLET
R
-WASHING MACHINE OUTLET
WM
-WATER PUMP
WP
-WATER TRANSFER PUMP
WTP
-SERVICE ENTRANCE
6.89 WP 6.89 -WIRING IN CONDUIT, RUN UNDER FLOOR
WP -WIRING IN CONDUIT, RUN IN CEILING / WALL
-CIRCUIT BREAKER
-GROUND/EARTH
M M M
-KILOWATT-HOUR METER
7
-CIRCUIT HOME RUN
G -STAND BY GENERATOR
1.80
-MANUAL TRANSFER SWITCH
MTS1 -MANUAL TRANSFER SWITCH
1PB1 -PANEL BOARD, PREFIXED INDICATES FLOOR LOCATION
1DP1 -DISTRIBUTION PANEL BOARD,
1.23 OPERABLE
LOW RAILING
PREFIXED INDICATES FLOOR LOCATION
FOR FIRE ESCAPE
1.44 FIRE
ESCAPE
2.40
PLANTBOX PLANTBOX 0.52 GENERAL NOTES/ SPECIFICATIONS
1. ALL ELECTRICAL WORKS AND EQUIPMENT SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE (PEC), SAMELCO I, BUREAU OF FIRE PROTECTION AND RA 7820 (NEW ELECTRICAL
ENGINEERING LAW)
2. ALL INSTALLATION/CONSTRUCTION WORKS SHALL BE UNDER SUPERVISION OF A REGISTERED ELECTRICAL
7.68 7.68
ENGINEER (REE)/PROFESSIONAL ELECTRICAL ENGINEER (PEE) OR REGISTERED ELECTRICIAN (RME)
3. MINIMUM SIZE WIRE SHALL BE 2.0 mm² (No.14 AWG) AND 3.5 mm² (No.12 AWG)
6.24
FOR LIGHTING AND CONVENIENCE OUTLETS, RESPECTIVELY
4. MAIN SERVICE ENTRANCE SHALL BE 3-200mm2 THHN @ 80mmØ RSC Conduit + 1-30mm2 THHN @ 25mmØ RSC
Conduit
5. UNLESS SHOWN IN THE PLAN, ALL WIRING SHALL BE IN STANDARD PVC CONDUIT, INSTALLED INSIDE THE
CEILING OR RUN EMBEDDED INSIDE WALLS OR UNDER FLOOR
6. EQUIPMENT SHALL INSTALLATION:
POWER LAYOUT, ROOF DECK SWITCHES/CONVENIENCE OUTLETS/ACU OUTLETS/PANEL BOARD SHALL BE FLUSH MOUNTED
7. MOUNTING HEIGHT OF EQUIPMENT:
a. CONVENIENCE OUTLETS - 300mm ABOVE FINISH FLOOR LINE
b. SWITCH OUTLETS - 1500mm ABOVE FINISH FLOOR LINE
c. ACU OUTLETS - LEFT HAND SIDE OF ACU UNIT
d. PANEL BOARD - 1500mm ABOVE FINISH FLOOR LINE
10.67
SEAL PROJECT TITLE: APPROVED BY: CONTENT : REVISIONS
PROFESSIONAL ELECTRICAL ENGINEER:
PROPOSED ELECTRICAL PLAN OF
ROMMEL P. MORON, PEE 1
A PROPOSED THREE STOREY WITH
ROOF DECK MIXED-USE BUILDING
"AS SHOWN'
2
EE8 EE10
3