The document outlines construction notes for a building project, emphasizing that wall thickness is generally 4.5 inches and that all drawings should be read in conjunction with structural and MEP drawings. It instructs contractors to verify dimensions, materials, and any discrepancies with the architect before execution. Additionally, it specifies details regarding electrical points, fixtures, and finishes as per client and architect approvals.

Uploaded by

PriyankPurwar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

30'x60'-First Model1

The document outlines construction notes for a building project, emphasizing that wall thickness is generally 4.5 inches and that all drawings should be read in conjunction with structural and MEP drawings. It instructs contractors to verify dimensions, materials, and any discrepancies with the architect before execution. Additionally, it specifies details regarding electrical points, fixtures, and finishes as per client and architect approvals.

Uploaded by

PriyankPurwar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES

WALL THICKNESS ARE 4.5 INCHES UNLESS OTHER WISE MENTIONED .


DRAWING MUST BE READ IN CONJUNCTION WITH STRUCTURAL DRAWINGS &
MEP DRAWINGS AS PER MATERIAL'S APPROVED BY CLIENT / ARCHITECT.
ALL STRUCTURAL SIZES & STRUCTURAL DETAIL TO BE REFERED
FROM DRAWINGS OF STRUCTURAL CONSULTANTS.
DRAWING NOT TO BE SCALED ONLY WRITTEN
DIMENSIONS TO BE FOLLOWED.
ANY DISCREPANCIES IN THIS DRAWING SHALL BE BROUGHT
TO THE NOTICE OF THE ARCHITECT BEFORE EXECUTION.
CONTRACTOR SHOULD STUDY DRAWING & RELATED APPROVED MATERIALS &
REVERT BACK IN CASE OF ANY DISCREPANCIES.
COLUMN NOS. & SIZE TO BE CROSS CHECKED
WITH STRUCTURAL DRAWING FOR REFERENCES
SITE BOUNDARY DIMENSIONS TO BE
REFERED FROM SURVEY DRAWING.
ELECTRICAL POINTS AS PER TILE JOINERY SHOULD BE CONSIDERED IN
30' REFERENCES TO ELECTRICAL LAYOUT & FOR ANY DISCREPANCIES SHOULD BE
BROUGHT TO THE NOTICE OF THE ARCHITECT BEFORE EXECUTION.
ALL THE DOORS, WINDOWS, SLIDING DOORS AND VENTELATOR SHOULD BE
CONSIDERED AS PER DETAIL DRAWINGS & THE HARD WARE FITTINGS,
LAMINATE / FINISHES, EXHAUT FAN APPROVED BY CLIENT & ARCHITECT.
SANTIORY WARE AS PER APPROVED SET AS SHOW IN DRAWING/ LAYOUT.

WASHING
GEYSER AS PER APPROVED BY CLIENT.

MACHINE
UTILITY ALL TAPS & FIXTURES FOR TOILETS & KITCHEN, REFER THE DETAIL DRAWINGS
& AS PER APPROVED BY CLIENT & ARCHITECT.

7'x4'-6"
TOILET
6'x7'-6"
MASTER
BASIN

BEDROOM
15'x12'

DRESSER
BASIN 7'x7'
POWDER ROOM
6'x4'
WARDROBE

STAIRWELL
DRAWING ROOM 10'X14'
18'-3"x14'-6"

T.V.UNIT

60'

TEMPLE
DINING HALL/ 6'x6'
FAMILY LOUNGE
22'-3"x12'-9"
DINING
TABLE

STORE
6'x6"

FRIDGE

MICROWAVE
BREAKFAST COUNTER

COPY/ PDF REV. DATE MODIFICATION


4'-6" WIDE
PASSAGE

CLIENT:-
BEDROOM KITCHEN GAS BURNER

13'-6"x12' 10'x12'
WARDROBE

ARCHITECT :

WASHING

TOILET
7'x5' BALCONY
BASIN
21'-3"x6'-6"
PROJECT TITLE:-

SECTOR 14, INDIRA


NAGAR, LUCKNOW

ROAD DRAWING TITLE:- NORTH


N
FIRST FLOOR
W E
PLAN

SHEET SIZE : SCALE :


A3 SHEET N.T.S

ARCHITECTURE: DATE
PROJECT NO.

APPROVED:-

R0