0% found this document useful (0 votes)
23 views12 pages

Fill-Rite Pump

The FR300V Series Fuel Transfer Pumps installation and operation manual provides essential safety information, installation procedures, and operating instructions for the Fill-Rite pumps. It emphasizes the importance of following safety guidelines, including proper electrical wiring and the use of an anti-siphon device. The manual also includes warranty details and troubleshooting tips to ensure optimal performance and safety during operation.

Uploaded by

Onasis Ventura
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views12 pages

Fill-Rite Pump

The FR300V Series Fuel Transfer Pumps installation and operation manual provides essential safety information, installation procedures, and operating instructions for the Fill-Rite pumps. It emphasizes the importance of following safety guidelines, including proper electrical wiring and the use of an anti-siphon device. The manual also includes warranty details and troubleshooting tips to ensure optimal performance and safety during operation.

Uploaded by

Onasis Ventura
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

FR300V SERIES FUEL TRANSFER PUMPS

Installation and operation manual

MADE IN
USA
| FR300V SERIES FUEL TRANSFER PUMPS

Table of Contents

Thank You! ............................................................................................2 Thank You!


Warranty Policy.....................................................................................2 Thank you for your loyalty to the Fill-Rite® brand of fuel transfer pumps.
About This Manual.................................................................................3 Your safety is important, so please read and thoroughly understand
the procedures set forth in this manual. In addition, please save these
Safety Information.................................................................................3 instructions for future reference and record the model, serial number, and
Installation........................................................................................ 3-4 purchase date of your fuel transfer pump. Protect yourself as well as those
around you by observing all safety instructions and adhering to all danger,
Anti-Siphon Device................................................................................5
warning, and caution symbols. Please register your Fill-Rite® product via
Bung Adapter and Suction Pipe Installation ...........................................5 info.tuthill.com/product_registration.
Nozzle Boot Installation.........................................................................5 IMPORTANT RETURN POLICY
Please do not return this product to the store. For all warranty and
Electrical Wiring....................................................................................6
product questions, please contact Tuthill Customer Service at
Wiring Procedure...................................................................................6 1-800-634-2695 (M-F, 8am – 6pm EST/EDT.
Operating Instructions...........................................................................6

Pad Locking...........................................................................................6
MODEL#
Safety Testing Approvals........................................................................7
SERIAL#
Fluid Compatibility.................................................................................7
PURCHASE DATE:
Technical Information / Specifications...................................................7

Troubleshooting ................................................................................ 8-9

Accessories ..........................................................................................9

Replacement Parts Information......................................................10-11

300VE Model Information....................................................................12

Limited Warranty Policy


Tuthill Fort Wayne warrants the goods manufactured shall be free from defects of materials and workmanship. Specific warranty details for individual
products can be found at fillrite.com.
INSTALLATION AND OPERATION MANUAL 3

About This Manual


From initial concept and design through its final production, your Fill-Rite pump is built to give you years of trouble-free use. To insure it provides that service, it is critical that you
read this entire manual prior to attempting to install or operate your new pump. Become familiar with the terms and diagrams, and pay close attention to the highlighted areas with
the following labels:

WARNING! Emphasizes an area in which personal injury or even death may result from failure to follow instructions properly.
Mechanical damage may also occur.

IMPORTANT! These boxes contain information that illustrates a point that may save time, or be key to proper operation, or clarifies a step.

CAUTION! Failure to observe a “Caution” may cause damage to the equipment.

At Tuthill, your satisfaction with our products is paramount to us. If you have questions or need assistance with your product, please contact us at 1-800-634-2695 (M-F 8 AM–6 PM ET).

Safety Information

WARNING! Electrical wiring should be performed ONLY by a licensed electrician in compliance with local, state, and national electrical code NEC/ANSI/NFPA 70,
NFPA30, and NFPA 30A, as appropriate to the intended use of the pump. Threaded rigid conduit, sealed fittings, and conductor seal should be used. The pump must
be properly grounded. Improper installation or use of this pump can result in serious bodily injury, or death!
1. NEVER smoke near the pump, or use the pump near open flames when pumping a flammable liquid! Fire can result!
2. A “Fill-Rite” Filter should be used on the pump outlet to insure no foreign material is transferred to the fuel tank.
3. Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks.
4. Storage tanks should be securely anchored to prevent shifting or tipping when full or empty.
5. To minimize static electricity build up, use only static wire conductive hose when pumping flammable fluids, and keep the fill nozzle in contact with the
container being filled during the filling process.
6. The pump motor is equipped with thermal overload protection; if overheated, the motor will shut off to prevent damage to the windings. If this happens,
TURN THE PUMP OFF! When the motor cools, it will restart without warning if the power is on.

WARNING! This product should not be used to transfer fluids into any type of aircraft.

WARNING! This product is not suited for use with fluids intended for human consumption or fluids containing water.

Installation
The Fill-Rite FR300V series pump is designed to offer several different mounting configurations. It can be mounted on a skid tank using the tank adapter supplied with the pump (see
attached diagrams) or mounted on a concrete island using an optional pedestal adapter (available through your Fill-Rite distributor). Regardless of mounting style, all tanks must be
properly vented.
The FR300V series pump has a built-in check valve with pressure relief to reduce unsafe excess pressure from thermal expansion of the fluid. It also features an integral bypass valve to
help minimize wear when the pump is operating with the nozzle closed.

CAUTION! Do not use additional check valves or foot valves unless they have a proper pressure relief valve built into them. Note that additional check valves
will reduce flow rate.

fillrite.com | tuthill.com
| FR300V SERIES FUEL TRANSFER PUMPS

CAUTION! Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks.

Typical Skid Tank Installation


SKID TANK INSTALLATION
Materials
• 1-1/4" pipe cut to a length that will terminate at least 3" from the bottom of the
tank when installed into the tank adapter with the tank adapter installed into the
tank flange (see SKID TANK INSTALLATION diagram).
• Threaded pipe joint sealant appropriate for application.

Installation Procedure
1. Thread the 1-1/4" pipe into the tank adapter. Seal threads liquid tight with
appropriate thread sealant.
2. Screw the tank adapter into the tank flange; seal threads liquid tight with
appropriate thread sealant.
3. Mount the pump on the adapter; seal threads liquid tight with appropriate
thread sealant.
4. Fill-Rite recommends installation of an Anti-Siphon Device. TANK ADAPTER
SKID TANK

Additional
specifications on page 7.
Typical "Pedestal / Island" Installation
Materials:
• 1-1/4" threaded suction pipe, cut to extend 32-1/2" above the island. TYPICAL PEDESTAL / ISLAND INSTALLATION
• FRPA125 Pedestal Kit (includes Pedestal Pipe, Base, & Coupler).
• Threaded pipe joint sealant appropriate for application. Additional specifications
on page 7.

Installation Procedure
1. Remove the coupler from the pedestal pipe by loosening the set screws.
2. Slip the pedestal pipe/pump base assembly over the 1-1/4" suction pipe.
3. Loosen the screws in the pedestal base to allow the pedestal pipe to slide down PEDESTAL COUPLER
exposing the end of the suction pipe.
4. Screw the coupler onto the suction pipe; seal threads liquid tight
with appropriate thread sealant.
5. Slide the pedestal pipe into the coupler and tighten the set screws.
6. Tighten the screws in the pedestal base. PEDESTAL PIPE ELECTRICAL CONDUIT
7. Mount the pump on the coupler seal threads liquid tight
with appropriate thread sealant.

CONCRETE ISLAND
36" SQUARE
PEDESTAL BASE
LAYOUT OF BASE ANCHOR BOLTS

1/2" BOLTS 1-7/8"

ELECTRICAL CONDUIT
CLEARANCE HOLE FUEL TANK
7 25/32"
1-7/8"
1 1/4" SUCTION PIPE 3" MIN. OFF
TANK BOTTOM

PUMP FRONT
INSTALLATION AND OPERATION MANUAL 5

CAUTION! Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks.

Anti-Siphon Device
Your FR300V series pump comes from the factory ready to install an anti-siphon tube back to the tank.
An anti-siphon device (a.k.a. vacuum breaker) is important because it will break a liquid siphon ANTI-SIPHON LINE
if there is an open nozzle or a leaking hose below the fluid level in the tank when the pump is turned off.
Fill-Rite recommends anti-siphon kit # KIT700AS be installed from the pump outlet back to the
vapor space in the tank.
This illustration shows where to install the tube so that it terminates in the vapor space at the top of the
tank. The tube must terminate in the vapor space; if it terminates below the fluid level in the tank, it will
not prevent siphoning. It is very important there are no liquid traps in the tubing; it must have a continuous
slope from the pump down to the tank, and can be connected into any opening in the top of the tank if the
tank adapter is not used. Use reducer bushings as required for proper fit and seal.
The ¼ NPT opening in the side of the tank adapter terminates in the vapor space of the tank. Make liquid-
tight connections using the appropriate sealant from the adapter to the anti-siphon outlet using a minimum
of 1/4 metal tubing that is compatible with whatever liquid is being pumped. If the anti-siphon tank adapter
is being used and the ¼ NPT opening is not used for the tubing, leave the factory installed plug in place.
Fill-Rite offers Anti-Siphon kit # KIT700AS (available through your Fill-Rite distributor). This kit contains
the necessary fittings and tubing to complete the installation as pictured in this section. NOTE: This kit TANK ADAPTER
ONLY works for tank top installations.
SKID TANK
If not using the KIT700AS, you will need the KIT700AVB. This will allow you to connect a line either back to
the tank, or to the bung adapter.

Bung Adapter / Suction Pipe Assembly and Installation


FR300V series pumps feature a 2" Bung Adapter with integral connection for an anti-
siphon device. When installing the suction pipe into the bung adapter, the suction pipe
must be inserted into the bung adapter correctly for proper operation. The suction pipe
TOP
threads into the tank adapter, and must be cut to a length that positions it at least 3"
from the bottom of the tank.
1. Measure and cut suction pipe to fit as described above.
2. Examine the bung adapter to determine top and bottom for proper insertion of the
suction pipe. The bung adapter is labeled to help: the end marked “PUMP SIDE” is
the top of the bung adapter. Note that the internal threads for the suction pipe are
at the TOP of the opening.
3. Wrap the threads of the suction pipe with the appropriate sealant for the fluid being
pumped. Insert the suction pipe (with the threaded side up) into the bottom of the
bung adapter until the threads engage.
4. Tighten the suction tube into the bung adapter to create an air / fluid tight seal.
5. Apply an anti-seize thread compound to the external threads on the bottom of the
bung adapter. Install the assembled bung adapter and suction pipe into the bung
opening on the tank. Tighten to a fluid / air tight seal.
1 1/4" SUCTION PIPE
6. Install pump onto bung adapter using appropriate fluid sealant, and tighten
to a fluid / air tight seal.

USE TWO LOWER HOLES IN


Nozzle Boot Installation NOZZLE BOOT FOR MOUNTING

The nozzle boot is installed using the lower two screw holes on the side of the boot. NOZZLE BOOT
Use supplied attaching hardware to install the nozzle boot.

When the nozzle is mounted correctly it will be in a horizontal position.


NOZZLE BOOT BRACKET

fillrite.com | tuthill.com
| FR300V SERIES FUEL TRANSFER PUMPS

Electric Wiring

WARNING! Electrical wiring should be performed ONLY by a licensed electrician in compliance with local, state, and national electrical code NEC/ANSI/NFPA 70,
NFPA30, and NFPA 30A, as appropriate to the intended use of the pump. Threaded rigid conduit, sealed fittings, and conductor seal should be used. The pump
must be properly grounded. Improper installation or use of this pump can result in serious bodily injury, or death!

CAUTION! All pumps should be operated at the Rated Nameplate Voltage. Power should be supplied to the pump from a dedicated 30 amp circuit breaker.
No other equipment should be powered by this circuit. Wiring must be of sufficient size to carry the correct current for the pump. Voltage drop will vary
with distance to pump and size of wire; refer to the National Electrical Code (NEC), or local codes, for Voltage Drop Compensation to be sure you are using
the correct size wire for your application.

Wiring Procedure

WARNING! The “AUX.” wire IS A LIVE WIRE when the switch is on! The “AUX” lead wire is insulated and enclosed when shipped. DO NOT connect this wire without
first verifying the “ON” line voltage of the wire for compatibility with the equipment to be installed. Maximum amperage on this wire is 1 amp. The “AUX” wire must
be insulated and enclosed in the junction box if not used.

115 VOLT WIRE DIAGRAM AUX LEAD RATED 1.0 AMP 230 VOLT WIRE DIAGRAM AUX LEAD RATED 1.0 AMP
Voltage Selector Switch
ORANGE ORANGE
AUX AUX
ON
BLACK BLACK Conduit opening
AC AC
1/2" NPT
OFF
WHITE WHITE
NEU MOTOR AC MOTOR
GREEN GREEN Pump Switch Lever
GRN GRN

1. Remove the junction box cover and straighten the wires to make sure the stripped wire ends are accessible outside the junction box.
2. Connect the pump wires to the power supply lines according to the diagram. Be certain to properly insulate the connections with the appropriate wire nuts or other connectors.
Note that the ground wire MUST be connected.
3. Fold the wires back into the junction box and replace the cover, making sure the cover gasket is in place.
Use the Voltage Selector Switch on the end of the pump to select the input voltage for the pump. NOTE: The pump comes from the factory pre-set to 115V AC position.

IMPORTANT! Be certain the gasket for the cover is in place, and the screws draw the cover down tight over the junction box. There must be no gap between
the junction box and it’s cover.

MAX CABLE LENGTH IN FEET (METERS)


Solid Wire Stranded Wire

AWG 14 12 10 8 6 4 14 12 10 8 6 4
115V AC
62 99 158 250 -- -- 61 96 154 245 389 620
(60Hz motor)
1/2 HP

230V AC
214 340 542 859 -- -- 209 331 529 844 -- --
(50Hz motor)
230V AC
221 351 560 887 -- -- 216 342 546 871 -- --
(60Hz motor)
115V AC
44 71 113 178 -- -- 43 69 110 175 278 443
(60Hz motor)
3/4 HP

230V AC
146 232 369 585 -- -- 142 226 360 574 -- --
(50Hz motor)
230V AC
149 237 377 598 -- -- 145 231 368 587 -- --
(60Hz motor)
INSTALLATION AND OPERATION MANUAL 7

Operating Instructions Padlocking


1. Reset Meter to “0” (if applicable). Your Fill-Rite pump nozzle can be padlocked
for added security. With the pump turned off,
2. Remove dispensing nozzle from nozzle boot.
and the nozzle in the stored position, a padlock
3. Move the switch lever to the “ON” position to power the pump. can be inserted through the nozzle rest and
4. Insert the dispensing nozzle into the container to be filled. nozzle handle opening. This configuration
prevents the nozzle from being removed
5. Operate the nozzle to dispense fluid; release nozzle when the desired amount from the nozzle cover.
of fluid has been dispensed.
6. Move switch lever to the “OFF” position to stop the pump.
7. Remove the dispensing nozzle from the container and store it in the nozzle boot.

CAUTION! Always keep the nozzle in contact with the container being filled during the filling process to minimize the possibility of static electricity build up.

Safety Testing Approvals


The Fill-Rite FR300V pumps have been safety tested for compliance to the standards set forth by UL Laboratories.

Fluid Compatibility
Diesel fuel, gasoline, kerosene, mineral spirits, Stoddard solvents, heptane, bio-diesel (B20 max.), and bio-diesel (B21 – B100) using KIT300BD.

IMPORTANT! If in doubt about compatibility of a specific fluid, contact supplier of fluid to check for any adverse reactions to the following wetted materials: cast
iron; steel; zinc plated steel; 300 series stainless steel; carbon; polyester; fluorocarbon; Teflon; brass; iron; copper; buna; 400 series stainless steel; aluminum.

Technical Information / Specifications

Design Features: Shipping Weight:


• Inlet: Bung: 2" male NPT; Suction pipe: 1-1/4" female NPT or FR310V: 80 lbs. / FR311V: 91 lbs. / FR319V: 92 lbs.
for “E” series models Bung: 2" male BSPT; Suction pipe: 1-1/2" BSPP.
• Outlet: 1" NPT, or 1" BSPT (BSPT on “E” series models). Accessories:
See page 9 for a complete list of available accessories.
• Cast iron pump housing: iron (composite) rotor, and carbon (composite) vanes.
• Security: Pump equipped for padlocking (see page 7 for details). Performance:
• Thermal overload protection. • 26 psi (1.79 bar) maximum pressure at pump outlet.
• Heavy duty switch. • Up to 35 gallons (132 liters) per minute.
• 30 minute duty cycle. • Maximum viscosity of fluid pumped: #2 diesel fuel.
• Explosion proof motor UL listed with sealed bearings that require no maintenance. • Maximum Pump Operating Temperature: 150 degrees F (66 degrees C).
• Integral check valve with pressure relief on inlet side prevents pressure build up • Minimum Pump Operating Temperature: minus 13 degrees F (minus 25 degrees C)
and improves vertical lift. (note that for operation at lower temperatures, we recommend the “Arctic Nozzle”
• Easy access strainer. and “Arctic Hose” accessories section on page 9).
• Automatic bypass valve. Suction Lift:
• 2" threaded base for tank openings. The lift in feet is equal to the vertical distance from the surface of the fluid in the tank
to the inlet of the pump, LESS friction losses through the vertical and horizontal runs of
• Constant Amp Draw (Service Factor of 1.0):
pipe, all elbows, and other fittings. System should be set up to require a minimum amount
- 115V AC 60Hz – 9.8 amps / 50Hz - 11.4 amps.
of suction lift.
- 230V AC 60Hz – 4.9 amps / 50Hz - 5.7 amps.
• For gasoline use models FR300VN and FR303V (1/2 hp models), suction lift cannot
Overall Dimensions: exceed 10' (3 m).
• Model FR310V: 17.12" wide X 15" high x 14.9" deep.
• For #2 diesel fuel use all other models (3/4 hp), suction lift is 18' (5.5 m).
• Model FR311V: 17.12" wide X 19.25" high x 14.9" deep.
• Model FR319V: 17.12" wide x 19.4" high x 14.9" deep.

fillrite.com | tuthill.com
| FR300V SERIES FUEL TRANSFER PUMPS

Troubleshooting
The following Troubleshooting guide is provided to offer basic diagnostic assistance in the event you encounter abnormal service from your Tuthill product.
If you have questions regarding installing, operating, or servicing your product, please feel free to contact our Customer Service Department at 1-800-634-2695 (M-F 8 AM–6 PM ET).
You can also reach us on the World Wide Web at “www.fillrite.com”.

WARNING! DO NOT open or attempt to repair the motor on your FR300V series pump. Opening the motor case can compromise the integrity of the Explosion Proof
construction and will void any existing warranty and certification (UL listing). Please refer to the warranty policy located on page 2.

WARNING! Be certain all power to the pump is turned off prior to performing any service or maintenance.

Symptom Cause Solution

1. Suction line problem Check for leaks in suction line.

2. Bypass valve open Remove and inspect valve, must move freely & be free of debris.

3. Vanes sticking Check vanes and slots for nicks, burrs and wear. *
Pump won't prime
4. Excessive rotor or vane wear Inspect rotor & vanes for excessive wear or damage, replace if necessary. *

5. Outlet blocked Check pump outlet, hose, nozzle & filter for blockage.

6. Vapor Lock Reduce vertical and horizontal distance from pump to liquid; Remove the automatic nozzle.

1. Excessive dirt Remove and clean screen.

2. Suction line problem Check suction line for leaks or restrictions; it may be too small, too long or not airtight.

3. Bypass valve sticking Remove and inspect valve; must move freely and be free of debris.

4. Vanes sticking Check vanes and slots of wear. *


Low capacity
5. Excessive rotor or vane wear Inspect rotor & vanes for excessive wear or damage; replace if necessary. *

6. Hose or nozzle damage Replace hose or nozzle.

7. Plugged filter Replace filter.

8. Low fluid level Fill tank.

1. Incorrect voltage Check incoming line voltage while pump is running.

2. Vanes sticking Inspect vanes and slots for nicks, burrs and wear. *
Pump runs slowly
3. Wiring problem Check for loose connections.

4. Motor problem Refer to warranty policy.

1. Bypass valve sticking Remove and inspect valve, must move freely & be free of debris.

2. Low voltage Check incoming line voltage while pump is running.


Motor stalls
3. Excessive rotor or vane wear Check rotor & vanes for excessive wear or damage. *

4. Debris in pump cavity Clean debris from pump cavity.

1. Pumping high viscosity fluids These fluids can only be pumped for short periods of time (less than 30 minutes duty cycle).

2. Clogged screen Remove and clean screen.


Motor overheats
(Thermal overload 3. Restricted suction pipe Remove and clean pipe.
tripped)
4. Motor failure Refer to warranty policy.

5. Pump rotor lock-up Clean and check pump rotor and vanes. *
INSTALLATION AND OPERATION MANUAL 9

Troubleshooting (continued)

Symptom Cause Solution

1. No Power Check incoming power.


2. Switch failure Refer to warranty policy.
Motor inoperative 3. Motor failure Refer to warranty policy.
4. Thermal protector failure Refer to warranty policy.
5. Incorrect/loose wiring Check wiring.
1. Bad o-ring gasket Check all o-ring gaskets.
2. Dirty shaft seal Clean seal and seal cavity.
Fluid leakage 3. Bad shaft seal Replace seal.
4. Incompatible fluid Refer wetted parts list to fluid manufacturer (see page 7).
5. Loose fasteners Tighten fasteners.
1. Dirt in pump cavity Clean out pump cavity.
Pump hums but
2. Motor failure Refer to warranty policy.
will not operate
3. Broken rotor insert Remove all debris & replace insert.

Bold text indicates repairs that are not serviceable by the owner; please refer to our warranty policy on page 2 for further instructions.
* Repairs marked with an asterisk (*) will require Repair Kit #300KTF7794. This kit includes a replacement rotor and new vanes, as well as a number of other important seals and
components to complete the repair.

Accessories
A wide variety of accessories are available to help you maximize the performance of your Fill-Rite pump. Listed below are the applicable available accessories for your specific product.
Please contact your authorized Fill-Rite distributor to purchase the accessories you need.

Part Number Description Part Number Description


F4010PM0 1" Filter (Particulate 10 micron) FRHA10020 1" Arctic Duty Hose (20')
F4030PM0 1" Filter (Particulate 30 micron) FRHMN100S 1" Nozzle, Manual Leaded Spout
700ACCF7017 1" Filter Head N100DAU13G 1" Auto Shut Off Nozzle (Ultra High Flow Diesel)
FRPA125 Island Pedestal Mount Kit N100DAU12G 1" Auto Shut Off Nozzle (High Flow Diesel)
KIT700AS Anti-Siphon Kit FRNA100DAU00 1" Auto Shut Off Nozzle (Arctic Duty - Diesel)
FRH10012 1" Hose (12') S100H1315 1" Multi-Plane Swivel
FRH10014 1" Hose (14') B100F475 1" Breakaway
FRH10020 1" Hose (20') WH10012 1" Whip Hose

fillrite.com | tuthill.com
| FR300V SERIES FUEL TRANSFER PUMPS

Replacement Parts Information


For repairs or routine maintenance, Fill-Rite offers the parts you need. The following parts diagram and list covers all applicable parts for your Fill-Rite product. These parts can be
obtained through any authorized Fill-Rite dealer. Be sure to use only genuine Fill-Rite replacement parts for your service and maintenance needs. For a list of authorized dealers,
please visit our web site at “www.fillrite.com”.

WARNING! DO NOT open or attempt to repair the motor on your FR300V series pump. Opening the motor case can compromise the integrity of the Explosion Proof
construction and will void any existing warranty and certification (UL listing). Please refer to the warranty policy located on page 2.

300KTF7794 - Repair kit KIT120NB - Standard nozzle boot, cast KIT300BD - Bio-diesel conversion kit

KIT300BV - Bypass kit KIT300GSK - Gasket, Lathe Cut, Nitrile (10) KIT300JC - Juction box cover

KIT300MA - Meter flange KIT300OT - Straight outlet flange KIT300RG - Rotor kit

KIT300SG - Check valve / strainer cover KIT300SW - Switch lever KIT700AS - Anti-siphon kit

KIT700AVB - Anti-siphon valve body KIT700BG - Machined tank adapter – AST 2 x 1-1/4 KIT700SL - Seal kit
INSTALLATION AND OPERATION MANUAL 11

FR300V / FR310V / FR311V / FR319V Parts List

Kit KIT300RG and


Seal Kit KIT700SL Detail

1
1
2
2
4 3 4 3

3 3

FR311V Parts List FR319V Parts List


The FR311V configuration adds a 901C Series mechanical meter, inlet meter flange, out- The FR319V configuration adds a 900CD or 900CDP series digital meter, inlet meter
let meter flange, the associated attaching hardware, and gaskets. This package is avail- flange, outlet meter flange, the associated attaching hardware, and gaskets. This package
able in gallon or liter register. is available in pulsing or non-pulsing configuration.

No. Gallon Kit Number Description Liter Kit Number Qty. No. FR319VB Kit # Description FR319VBP Kit # Qty.

901C Meter (only) -- 900CDP Meter 900CDP 1


1 901C -- 1
(Gallons) 900CD Digital
2 Meter Flange 1
2 Meter Flange 1 Meter (no pulser)
901C Meter 901CL Meter 3 Meter Gasket 900CDP Meter 2
FR319VB
3 (Gallon) Kit # Meter Gasket (Liter) Kit # 2 w/integral pulser
4 1" Meter Fitting FR319VBP 1
901CMK300V 901CLMK300V
4 1" Meter Fitting 1
1 900CD 900CD Meter (only) --
1 -- 901CL Meter (only) (Liters) 901CL 1
N/S -- Intrinsic Safety Barrier* KIT900DPBA 1
*For use with 900CDP pulsing meter only

fillrite.com | tuthill.com
IMPORTANT! DO NOT open or attempt to repair the motor on your FR300V series pump. Opening the motor case can compromise the integrity of the Explosion
Proof construction and will void any existing warranty and certification (UL listing). Please refer to the warranty policy located on page 2.

Specific Conditions of Use (continued)


ATTENTION!
2. ISO Class 8.8, M6 hex-head screws (Yield Stress 640 MPa) shall be used to replace
The following information is for suffix “E” pumps and meters. Refer to the informa-
the terminal cover fasteners.
tion label applied to your pump to see if it is applicable.
3. ISO Class 8.8, M8 hex-head screws (Yield Stress 640 MPa) shall be used to replace
the stator housing fasteners.
Motor Plate Information
4. An electrically conductive hose and nozzle must be used with flammable liquids.
ENTRY THREADS ARE M20-1.5 6H To minimize static electricity buildup, always keep the nozzle in contact with the
VOLT: 115/230 Hz: 60/50 HP: ¾ AMB TEMP: 40°C PH: 1 RPM: 1725/1425 container being filled during the fueling process.
DUTY RATING: 30 MIN. FLA: 9.8/4.9/11.4/5.7 INS: B
The following standards were used to show compliance in the European Union:
Serial Number and Year of Manufacture.
EN IEC 60079-0:2018, Ed 7 “Explosive atmospheres – Part 0: Equipment –
II 2 G
General requirements”
Tuthill Ex db h IIA T4 Gb
FM09ATEX0075X EN 60079-1:2014, Ed 7 “Explosive atmospheres – Part 1: Equipment protection by
8825 Aviation Drive
2809 Ex db IIA T4 Gb flameproof enclosures “d””
Fort Wayne, IN 46809 USA IECEx FMG19.0014X
EN ISO 80079-36:2016, Ed 1 “Explosive atmospheres – Part 36: Non-electrical equip-
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. ment for explosive atmospheres – Basic method and requirements”
EN ISO 80079-37:2016, Ed 1 “Explosive atmospheres – Part 37: Non-electrical equip-
Materials of Construction ment for explosive atmospheres – Non electrical type of protection constructional safety
Materials of construction of the external surface of the unit are: painted steel; “c”, control of ignition source “b”, liquid immersion “k””
painted cast iron; painted aluminum; zinc plated steel.
Directive 2014/34/EU – Equipment and protective systems intended for use in potential-
Materials of construction of the wetted parts are: cast iron; steel; zinc plated steel; ly explosive atmospheres.
300 series stainless steel; carbon; polyester; fluorocarbon; Teflon; brass; iron; copper;
Directive 2011/65/EU – Restrictions of the use of certain hazardous substances in
buna; 400 series stainless steel; aluminum.
electrical and electronic equipment.
Repair and Maintenance
The following standards were used to show compliance for IECEx certification:
Contact the place of purchase for warranty repair and maintenance
IEC 60079-0:2017, Ed 7
Installation
IEC 60079-1:2014, Ed 7
Pump must be installed in compliance with EN 60079-14 or IEC 60079-14, as applicable.
Certificates for Compliance of Safety have been obtained for the following agencies for
products sold outside the US and Canada. Please refer to the tag on your particular
product for its particular compliance data.

Specific Conditions of Use


1. Consult the manufacturer if dimensional information on the flameproof joints
2809
is necessary.

Tuthill Corporation Tuthill UK LTD.


8825 Aviation Drive Birkdale Close Manners Industrial Estate
Fort Wayne, Indiana 46809 USA Ilkeston, Derbyshire
DE7 8YA UK
P (800) 634-2695
(+01) 260-747-7524 P +44 0 115 932 5226
F (800) 866-4681 F +44 0 115 932 4816

tuthill.com | fillrite.com | sotera.com

300H0745 Rev. 7