College Construction Proposal

The document is a final project proposal for the construction of a New Emergency Services building at Crafton Hills College, part of the San Bernardino Community College District, with a budget year of 2013-2014. It includes a detailed checklist of requirements, project terms and conditions, an analysis of building space use, and cost estimates, totaling approximately $13,233,887. The proposal emphasizes compliance with state regulations and outlines the project's scope, including classrooms, labs, and administrative offices.

Uploaded by

amoruf18
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views81 pages

College Construction Proposal

The document is a final project proposal for the construction of a New Emergency Services building at Crafton Hills College, part of the San Bernardino Community College District, with a budget year of 2013-2014. It includes a detailed checklist of requirements, project terms and conditions, an analysis of building space use, and cost estimates, totaling approximately $13,233,887. The proposal emphasizes compliance with state regulations and outlines the project's scope, including classrooms, labs, and administrative offices.

Uploaded by

amoruf18
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 81

California Community Colleges

Final Project Proposal

Final Project Proposal

Budget Year 2013-2014


Community College Construction Act of 1980
Capital Outlay Budget Change Proposal

New Emergency Services (OE-2) Building


Proposal Name

San Bernardino Community College District


Community College District

Crafton Hills College


College or Center

July 1, 2011
Date

A____ P__X__ W__X__ C__X__ E___X___


California Community Colleges
Final Project Proposal

FINAL PROJECT PROPOSAL CHECK LIST

District: San Bernardino Community College District


College: Crafton Hills College
Project Name: New Emergency Services (OE-2)
Prepared by: Maas Companies Data Prepared: 1-Jul-11

Description Completed
1.1 Title Page yes
2.1 Final Project Proposal Checklist yes
3.1 Approval Page - FPP Proposal (original signatures) yes
3.2 Project Terms and Conditions yes
4.1 Analysis of Building Space--JCAF 31 yes
4.1A Quantities & Unit Cost for JCAF-32 yes
5.1 Cost Estimate Summary - JCAF 32 yes
5.2 Energy Calculator yes
6.1 California Energy Commission Audit yes
7.1 State Administrative Manual Requirements yes
8.1 CEQA Compliance yes
9.1 Outline of Specifications yes
10.1 Federal Funds Detail yes
11.1 Analysis of Future Costs yes
12.1 Campus Plot Plans yes
13.1 Diagrams of Building Area yes
13.2 Site Plans yes
13.3 Floor Plans yes
13.4 Exterior Elevations yes
13.5 Electrical Plans (as needed) NA
13.6 Mechanical Plans (as needed) NA
13.7 Building Cross-Sections (as needed) NA
14.1 Guideline-Based Group 2 Equipment yes
15.1 Justification of Additional Costs Exceeding Guidelines yes
16.1 Detailed Equipment List yes
California Community Colleges
Final Project Proposal

PROJECT TERMS AND CONDITIONS

District: San Bernardino Community College District College: Crafton Hills College
Project: Emergency Services (OE-2) Budget Year: 2013-2014

1. The applicant hereby requests State funds in the amount prescribed by law for the project named herein.
All parts and exhibits contained in or referred to in this application are submitted with and made part of
this application.
2. The applicant hereby certifies to the Board of Governors of the California Community Colleges that:
a. Pursuant to the provisions of Section 57001.5 of Title 5 of the California Code of Regulations
no part of this application includes a request for funding the planning or construction of
dormitories, stadia, the improvement of sites for student or staff parking, single-purpose
auditoriums or student centers other than cafeterias. The facilities included in the proposed
project will be used for one or more of the purposes authorized in Section 57001.5.
b. Any State funds received pursuant to this application shall be used solely for defraying the
development costs of the proposed project.
If the application is approved, the construction covered by the application shall be undertaken
in an economical manner and will not be of elaborate or extravagant design or materials.
c. Pursuant to the provisions of Section 81837 of the Education Code, approval of the final plans
and specifications for construction will be obtained from the Board of Governors of the
California Community Colleges before any contract is let for the construction.
d. No changes in construction plans or specifications made after approval of final plans which
would alter the scope of work, function assignable and/or gross areas, utilities, or safety of the
facility will be made without prior approval of the Chancellor’s Office of the California
Community Colleges and the Department of General Services, Division of the State Architect.
e. Pursuant to the provisions of Section 57001 of Title 5 of the California Code of Regulations, an
adequate and separate accounting and fiscal records and accounts of all funds received from
any source to pay the cost of the proposed construction will be maintained, and audit of such
records and accounts will be permitted at any reasonable time, during the project, at the
completion of the project, or both.
f. Architectural or engineering supervision and inspection will be provided at the construction site
to ensure that the work was completed in compliance with the provisions of Section 81130 of
the Education Code and that it conforms with the approved plans and specifications.
g. Pursuant to the provisions of State law, no State-funded construction contract shall be awarded
prior to approval of the project by the State Public Works Board and release of funds by the
State Department of Finance.
3. It is understood by the applicant that:
a. No claim against any funds awarded on this application shall be approved which is for work or
materials not a part of the project presented and approved by the State Public Works Board.
California Community Colleges
Final Project Proposal

Project Terms and Conditions (Continued)

b. The failure to abide by each of the assurances made herein entitles the Board of Governors of
the California Community Colleges to withhold all or some portion of any funds awarded on
this application.
c. Any fraudulent statement which materially affects any substantial portion of the project
presented in this application, as it may be finally approved, entitles the Board of Governors of
the California Community Colleges to terminate this agreement or payment of any funds
awarded on the project presented in this application.
4. It is further understood that:
a. The appropriation which may be made for the project presented in this application does not
make an absolute grant of that amount to the applicant.
b. The appropriation is made only to fund the project presented in this application, as it is finally
approved, regardless of whether the actual cost is less than or equals the appropriation.
c. A change in the scope of the project or assignable areas shall only be granted with the approval
of legislature or its designated agent.
California Community Colleges
Final Project Proposal

ANALYSIS OF BUILDING SPACE USE AND WSCH - JCAF 31


District: San Bernardino Community College District Project: Emergency Services (OE-2)
College: Crafton Hills College Prepared by: Maas Companies Date: 1-Jul-11

Room Project Existing Increase in Space ASF Change WSCH Cost/ASF Total Allowable
Type TOPS Code DescriptionDepartment Space ASF Space ASF ASF Prior Submittal Capacity Cost
50 99 Inactive-General Assignment 891 -891 0 0 0
110 1201 Classroom-General Assignment 6,290 3,863 2,427 5,657 $446 2,805,340
210 1200 Laboratory-Health Occupations 1,350 1,350 631 $530 715,500
210 2100 Laboratory-Public & Protective Services 4,050 4,050 1,892 $446 1,806,300
215 2100 Lab. Serv.-Public & Protective Services 830 465 365 0 $446 370,180
215 4900 Lab. Serv. Interdisciplinary Studies 400 400 0 $464 185,600
220 2100 Special Class Lab.-Public/Protect. Serv. 1,200 1,208 -8 561 $446 535,200
230 4900 Ind. Studies Lab.-Interdis. Studies 1,488 1,488 579 $464 690,432
310 99 Office-General Assignment (Faculty) 1,080 1,332 -252 0 $471 508,680
310 6000 Office-Instructional Administration 160 160 0 $452 72,320
315 99 Office-Service 210 210 0 $471 98,910
680 99 Meeting Room 990 990 0 $444 439,560
740 2100 Vehicle Storage-Public/Protective Serv. 4,120 4,536 -416 0 $127 523,240
Total ASF 22,168 12,295 9,873
Total GSF 33,100 15,730 17,370 NA 9,320 $394.77 $8,751,262
CCI: 5394
EPI: 3016
QUANTITIES AND UNIT COSTS SUPPORTING THE JCAF 32
The District utilized two approaches for developing the cost estimate for the proposed OE-2 Replacement
project. One approach utilized the CCI Index 5394 as provided by the Chancellor's Office to determine
construction costs and the second appraoch was the preparation of an independent cost estimate
for the project from a private cost estimating firm. The first approach utilized the CCI Index 5394 as
provided by the Chancellor's Office to determine the construction cost. The second approach was to
obtain an independent cost estimate from a local cost-estimating firm.The two estimates, are within
10% (approx) of each other.

As justification and additional background data, the detailed analysis prepared by Cumming has been
included in the FPP in support of this cost estimate. The District will fund any project costs that exceed
the total proposed budget of $13,233,887.
Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California

Rough Order of Magnitude Statement of Probable Cost


May 5, 2011
Cumming Project No. 11-00227.00

Prepared for Steinberg

660 SOUTH FIGUEROA STREET • SUITE 900 • LOS ANGELES, CALIFORNIA • 90017
PHONE: (213) 408 4518 • FAX: (213) 408 4665
www.ccorpusa.com/
Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

TABLE OF CONTENTS

Page Number

1. Project Introduction / Qualifications

Introduction …………………………………………………………………………… 3

2. Cost Summaries

Construction Cost Summary ………………………………………………………. 8

Overall Component Cost Summary ……….……………………………………… 9

3. Construction Cost Back Up

Schedule of Areas & Control Quantities...….……………………………………… 10

Utility Service………………………………...….……………………………………… 11

Site Development Service………………....….……………………………………… 12

Site Development General Construction...….……………………………………… 13

New Construction Detail………….……......….……………………………………… 14

Prepared by Cumming Sheet 2 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

INTRODUCTION

1. Basis Of Estimate

This statement is based on the Rough Order of Magnitude package as prepared by Steinberg (dated 3/16/11),
received on 4/19/11, along with verbal direction from the architect and engineer.

Drawings: Existing site plan


Proposed site plan
Utility plan
Proposed site plan marked up for landscape and hardscape
Building plan

Specifications / Project Manual: Space Needs Matrix

Consultant Reports: MEP Basis of Design (Rough draft dated April 28th, 2011)

Costs provided by others: N/A

Project Delivery Schedule: As indicated in the IPP

2. Consultant Team

Company Name Contact Email Address Telephone

Steinberg John Wirfs jwirfs@steinberg.us.com 213 542 1320

3. Scope of Estimate

The project comprises the construction of a new Emergency Services (OE 2) building that comprises teaching
labs, classrooms, offices and vehicle storage totaling 33,087 square feet.

4. Items Affecting the Estimate

A Specific Inclusions

Items which are detailed in the backup to this estimate include the following:

1 Main building and site

Prepared by Cumming Sheet 3 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

INTRODUCTION

B Specific Exclusions

Items which are not detailed in the backup to this estimate include the following:

1 Professional design and consulting fees.


2 General building permit.
3 Testing fees.
4 Owner’s field inspection costs.
5 Construction / project manager’s fees.
6 Plan check fees and building permit fees.
7 Furnishings, fixtures and equipment (FF&E) / Group II.
8 Owner-furnished items.
9 Telephone equipment and cabling.
10 Building signage beyond code-required signage.
11 Artwork and interior plants.
12 Construction contingency.
13 Move-in costs or maintenance costs after move-in.
14 Financing and carry costs.
15 Hazardous material abatement (if required).
16 4 story tower
17 Escalation
18 Photovoltaic panels

C Items Affecting the Cost Estimate

Items which may change the estimated construction cost include, but are not limited to:

1 Modifications to the scope of work included in this estimate.


2 Restrictive technical specifications or excessive contract conditions.
3 Any specified item of equipment, material, or product that cannot be obtained from at least three
(3) different sources.
4 Any other non-competitive bid situations.
5 Bids delayed beyond the projected schedule.
6 Unit prices for commodities such as aggregate base, fill soils, and soils export can vary greatly
from those presented herein, depending upon the demand for such materials (or lack thereof)
within the dirt market at the time of actual construction.
7 Note: Given the current instabilities in the world market, the cost of many products (including,
but not limited to, asphalt, Portland Cement concrete, lumber, sewer, water, and drain pipe, and
steel) may differ significantly at the time material orders are actually placed from what is shown
herein (beyond that accounted for by reasonable escalation rates).

Prepared by Cumming Sheet 4 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

INTRODUCTION

D Assumptions made in the Cost Estimate

This estimate was prepared under the following assumptions:

1 The site will be fully accessible during normal working hours.


2 No phasing will be required.
3 Construction contract procurement method is competitive, public G.C. bid.
4 Prevailing wage labor rate structure.
5 This project will be subject to DSA review and inspection.
6 This project is aiming to achieve LEED Certification.
7 The owner/owners representative will add escalation as they deem appropriate

5. Notes

Statement of Probable Cost

Cumming has no control over the cost of labor and materials, the general contractor’s or any subcontractor’s
method of determining prices, or competitive bidding and market conditions.

This opinion of the probable cost of construction is made on the basis of the experience, qualifications, and best
judgment of a professional consultant familiar with the construction industry. However, Cumming cannot and does
not guarantee that proposals, bids, or actual construction costs will not vary from this or subsequent cost
estimates.

The statement reflects probable construction costs obtainable in a competitive and stable bidding market. This
estimate is based upon a minimum of four (4) competitive bids from qualified general contractors, with bids from a
minimum of three (3) subcontractors per trade. This statement is a determination of fair market value for the
construction of the project and is not intended to be a prediction of low bid. Experience indicates that a fewer
number of bidders may result in a higher bid amount, and more bidders may result in a lower bid result.

In accordance with industry analyses, it has been determined that the number of competitive bids obtained may
have the following effect:

1 bid add 15% to 40%


2 to 3 bids add 8% to 12%
4 to 5 bids -4% to +4%
6 to 8 bids deduct 5% to 7%
9 or more bids deduct 8% to 25%

Caveat emptor! The bid price is not necessarily the final cost. Please be advised that opening up the bid process
to all comers invites bid-day errors and "lowball" bids from potentially less-than-qualified bidders who will seek to
make their profit on the job via an unending stream of change order requests.

The Cumming staff of professional cost consultants has prepared this estimate in accordance with generally
accepted principles and practices. This staff is available to discuss its contents with any interested party.

Prepared by Cumming Sheet 5 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

INTRODUCTION

Recommendations for Cost Control

Cumming recommends that the Owner and the Architect carefully review this entire document to ensure that it
reflects their design intent.

Requests for modifications of any apparent errors or omissions to this document must be made within ten (10)
working days of the date of this estimate. Otherwise, it will be understood that the contents have been concurred
with and accepted. If the project is over budget, or there are unresolved budgeting issues, alternate systems /
schemes should be evaluated before proceeding.

Basis for Quantities

Wherever possible and practical, this estimate has been based upon the actual measurement of different items of
work. For the remaining items, parametric measurements were used in conjunction with references from other
projects of a similar nature.

The gross floor area (GFA) quantities utilized herein were provided by the architect.

Basis for Unit Costs

The unit costs enumerated herein are based on current bid prices in the Yucaipa, California area.

Subcontractor’s overhead and profit is included in each line item unit cost. This overhead and profit covers each
subcontractor’s cost for labor burden, materials and equipment sales taxes, field overhead, home office overhead,
and profit. The general contractor’s overhead and profit is shown separately on the Summary.

Sources for Pricing

This estimate was prepared by a team of qualified cost consultants experienced in estimating construction costs at
all stages of design.

These consultants have used pricing data from the Cumming database for construction, updated to reflect current
market conditions in the Yucaipa, California area at the time the estimate was prepared. In some cases, quotes
were solicited from outside sources to substantiate in-house pricing data.

Subcontractor's Mark-ups

As stated earlier, subcontractor’s mark-ups have been included in each line item unit cost. Depending on the
trade, these mark-ups can range from 15% to 20% of the raw cost for that particular item of work.

Prepared by Cumming Sheet 6 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

INTRODUCTION

6. Prorates

General Conditions

A reasonable allowance based on 6% of the construction cost subtotal has been included for the contractor's
general conditions.

Contractor's Bonds

A reasonable allowance based on 1% of the construction cost subtotal has been included for the contractor's
payment and performance bonds (if required).

Contractor's General Liability Insurance

A reasonable allowance based on 1% of the construction cost subtotal has been included for the contractor's
general liability insurance.

Contractor's Fee

A reasonable allowance based on 4% of the construction cost subtotal has been included for the general
contractor's home office over head and profit. Site overhead is included in the general conditions.

Design / Estimating Allowance

None

Escalation

Escalation is excluded from this report.

Construction Start: 10/01/14


Construction Completion: 11/01/15
Construction Midpoint: 04/17/15
Construction Duration: 13 Months

Phasing Allowance

No phasing is required for this project.

Construction Management Fee

Not applicable.

Construction Contingency

This is a part of the Soft Costs which have been excluded from this estimate but it is prudent for all program
budgets to include an allowance for change orders which occur during construction. These change orders
normally increase the cost of the project. It is recommended that the owner, in their program budget, carry a
percentage of anywhere from 5% - 10% of the construction cost for this construction contingency.
Prepared by Cumming Sheet 7 of 22
Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

COST ESTIMATE SUMMARY - JCAF 32

Section Area Cost / SF Total

4. Construction (Budget CCI: 5394)

A. Utility Service $180,899

B. Site Development, Service $349,900

C. Site Development, General $537,032

D. Other Site Development N/A

E. Reconstruction N/A

F. New Construction $9,882,857

G. Other (Energy Initiatives) N/A

$10,950,688

Prepared by Cumming Sheet 8 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

OVERALL COMPONENT SUMMARY

Element Subtotal Total Cost / SF Cost / SF

A) Shell (1-5) $4,252,509 $125.86


1 Foundations $334,683 $9.91
2 Vertical Structure $453,896 $13.43
3 Floor & Roof Structures $1,336,917 $39.57
4 Exterior Cladding $1,638,288 $48.49
5 Roofing and Waterproofing $488,725 $14.46

B) Interiors (6-7) $1,198,660 $35.48


6 Interior Partitions, Doors and Glazing $682,308 $20.19
7 Floor, Wall and Ceiling Finishes $516,353 $15.28

C) Equipment and Vertical Transportation (8-9) $401,886 $11.89


8 Function Equipment and Specialties $401,886 $11.89
9 Stairs and Vertical Transportation $0 $0.00

D) Mechanical and Electrical (10-13) $4,029,803 $119.27


10 Plumbing Systems $460,647 $13.63
11 Heating, Ventilation and Air Conditioning $1,431,228 $42.36
12 Electrical Lighting, Power and Communications $1,914,660 $56.67
13 Fire Protection Systems $223,268 $6.61

E) Site Work (14-17) $1,067,831 $31.60


14 Utilities Service $180,899 $5.35
15 Site Development $349,900 $10.36
16 Site Development General $537,032 $15.89
17 Other Site Development $0 $0.00

TOTAL ESTIMATED CONSTRUCTION COST $10,950,688 $324.11

Total Area: 33,787 SF

Prepared by Cumming Sheet 9 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

Schedule of Areas & Control Quantities

Schedule of Areas SF SF

Enclosed Areas
First Floor 33,087

Subtotal, Enclosed Areas 33,087

Covered Areas
First Floor (Entrance canopies (x2) 1,400

Subtotal, Covered Areas 1,400

Covered Areas @ 50% 700

Total Gross Floor Area 33,787

Ratio to Gross
Control Quantities Qty Area

Number of Levels 1 EA 0.03


Gross Area 33,787 GSF 1.000
Assignable Floor Area
Classrooms 3,440 SF 0.102
Lecture 2,850 SF 0.084
Class laboratory 5,400 SF 0.160
Class Laboratory Services 1,230 SF 0.036
Spec Class Laboratory 1,200 SF 0.036
Individual Study Laboratory 1,488 SF 0.044
Office & Meeting Rooms 2,440 SF 0.072
Vehicular storage 4,120 SF 0.122
Total Assignable Floor Area 22,168 SF 0.656
Enclosed Area 33,087 SF 0.979
Covered Area 1,400 SF 0.041
Footprint Area 33,087 SF 0.979
Footprint Perimeter 950 LF
Volume (gross) 586,805 CF 17.368
Gross Wall Area (skin) 19,996 SF 0.592
Retaining Wall Area (building) - SF 0.000
Finished Wall Area (skin) 19,996 SF 0.592
Windows or Glazing Area (skin) 25.00% 4,999 SF 0.148
Roof Area (flat) 33,087 SF 0.979
Roof Area (curved) - SF 0.000
Total Roof Area 33,087 SF 0.979
Interior Partitions 1,757 LF 0.052
Interior Doors 47 LF/ door 37 EA 0.001
Plumbing Fixtures 40 EA 0.001

Prepared by Cumming Sheet 10 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

A. Utility Service Construction Component Detail

Element Quantity Unit Unit Cost Total

A Utility Service

Fire Water
Water line, 8" pvc C900 cl 200, incl t & bf 190 LF $103.46 $19,657
Fire hydrants 2 EA $5,172.97 $10,346
Post indicator valves 2 EA $3,621.08 $7,242
Gate valve, 6" 1 EA $840.61 $841
Fire department connection 2 EA $2,198.51 $4,397

Domestic Water
PVC, 4" pipe, incl t & bf 160 LF $60.78 $9,725
Water meter, 4" 1 EA $16,294.85 $16,295

Sanitary Sewer
6" Sanitary sewer line, incl t & bf 160 LF $80.18 $12,829
Manholes 1 EA $5,172.97 $5,173
Sewer cleanouts 1 EA $1,034.59 $1,035

Storm Drainage
12" PVC pipe, incl t & bf 500 LF $93.11 $46,557
Grate Inlet, 12" x 12" 2 EA $711.28 $1,423
Storm drain cleanout 2 EA $750.08 $1,500
Junction structure 1 EA $1,163.92 $1,164

Gas Piping
Medium pressure gas system, 4", plastic, incl t & bf 90 LF $60.78 $5,470
Gas meter 1 EA $5,431.62 $5,432

Hot/chilled water
Piping, inc trench & backfill: 90 LF $116.39 $10,475

Electrical
Extend electrical mains and connect to building 150 LF $142.26 $21,338

$180,899

Prepared by Cumming Sheet 11 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

B. Site Development, Service Construction Component Detail

Element Quantity Unit Unit Cost Total

B Site Development Services

Demolition of building and structures


Demolish existing single story buildings (x2) 15,000 SF $10.35 $155,189

Site protective construction


Erosion control 1 LS $10,345.94 $10,346

Site clearing and grading


Strip and remove existing paving, site walls, landscape, etc. 72,000 SF $1.16 $83,802
Rough grading, cut and fill, based on balanced site 72,000 SF $1.03 $74,491
Fine grading 72,000 SF $0.36 $26,072

$349,900

Prepared by Cumming Sheet 12 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

C. Site Development, General Construction Component Detail

Element Quantity Unit Unit Cost Total

C Site Development General

Vehicular paving
Heavy traffic, 3" AC over 12" AB 12,000 SF $7.76 $93,113

Pedestrian paving
Concrete paving, 4" thick, including sub base, reinforcement, and
integral color finish 18,000 SF $12.93 $232,784

Concrete curbs
Concrete curbs 500 LF $19.40 $9,699

Parking Lot Striping/Signage 1 LS $6,466.21 $6,466

Landscape
Grass, shrubs, trees, etc. 8,913 SF $7.76 $69,160

Miscellaneous
Site walls, planters, etc. 38,913 SF $3.23 $125,810

$537,032

Prepared by Cumming Sheet 13 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

1 Foundations

Excavation
Over excavation and recompaction of building footprint and 5' around
perimeter of building, depth of excavation is 5' 7,009 CY $10.35 $72,515

Reinforced concrete including excavation


Reinforced concrete grade beams, column and wall footings; top of
footing assumed to be 18" below grade with depth of footing not
exceeding 3' 33,787 SF $7.76 $262,169

$334,683

2 Vertical Structure

Columns and pilasters -


HSS steel tube columns, assume an allowance of 6lbs/gsf for vertical
steel members, standard steel sizes and detail connections
incorporating brace frame system with wide flange columns and HSS
tube braces 101 T $4,138.37 $417,976

Fireproofing steelwork
Sprayed fireproofing 101 T $355.64 $35,920

$453,896

3 Floor & Roof Structures

Floor at lowest level


Reinforced concrete slab on grade, 5" thick
Formwork 2,000 SF $7.76 $15,519
Vapor barrier 33,087 SF $0.19 $6,418
Sand cushion 33,087 SF $0.39 $12,837
Gravel sub base - 6" 33,087 SF $1.55 $51,347
Reinforcement, assume 1.65lbs/sf 33,314 LB $0.97 $32,312
Concrete, 4000psi 648 CY $245.72 $159,224
Finish and cure concrete surface 33,087 SF $1.62 $53,487

Premium for additional thickness at vehicle storage 4,125 SF $6.47 $26,673

Prepared by Cumming Sheet 14 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

Flat roofs
Structural steel wide flange girders and joists, assume 7lbs/sf 116 T $4,138.37 $480,051
Verco W3 3" metal deck, 20 gauge 33,087 SF $5.17 $171,158
Reinforced light weight concrete including mesh reinforcement with
steel bar reinforcement as required 33,087 SF $6.47 $213,947
Finish and cure concrete surface 33,087 SF $1.62 $53,487

Miscellaneous
Mechanical equipment pads located on roof 864 SF $19.40 $16,760
Miscellaneous metals, support framing and wood blocking 33,787 SF $1.29 $43,695

$1,336,917

4 Exterior Cladding

Block work
Reinforced CMU with burnished finish 19,996 SF $28.45 $568,913

Windows, glazing and louvers

Glazed aluminum framed windows with 1" insulated low "e" glazing 4,999 SF $109.93 $549,518

Exterior door frames and hardware


Single 3 EA $3,879.73 $11,639
Double 3 EA $7,759.45 $23,278
Motorized, glazed roll up 4 EA $32,331.05 $129,324

Fascias, bands, screens and trim


Shading devices and trim 19,996 SF $6.47 $129,298
Signage 1 LS $7,759.45 $7,759

Canopy
Entrance canopies 1,400 SF $84.06 $117,685

Balustrades, parapets and roof screens


Pre-finished metal mechanical screen including galvanized structural
steel supports 1,200 SF $84.06 $100,873

$1,638,288

Prepared by Cumming Sheet 15 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

5 Roofing and Waterproofing

Insulation
Rigid board insulation, R-30, polyisocyanurate 33,087 SF $4.53 $149,763

Roofing
PVC membrane system 33,087 SF $7.76 $256,737

Roof deck or traffic surfaces


Walkway pads at roof mechanical bay area 600 SF $7.76 $4,656

Roofing upstands and sheet metal


Parapet coping and wall flashings and miscellaneous flashings 33,087 SF $1.29 $42,789

Skylights 100 SF $84.06 $8,406

Roof access and ventilation


Roof access hatch and stair/ladder 1 EA $4,526.35 $4,526

Caulking and sealing


Miscellaneous caulking and sealing 33,787 SF $0.65 $21,847

$488,725

6 Interior Partitions, Doors and Glazing

Partition framing and core


CMU partition walls 2,800 SF $20.69 $57,937
Metal stud framing forming shaft walls, chase walls, 1 hour fire walls
and non rated walls 25,350 SF $10.35 $262,269

Partition surfacing
Gypsum board, taped and sanded, 5/8" 49,350 SF $2.72 $134,025
Paint gypsum board surfaces and cmu 54,950 SF $0.91 $49,745

Sound insulation
Batt insulation, R-14 25,350 SF $1.03 $26,227
Sound caulking/acoustic sealants 33,787 SF $0.52 $17,478

Window walls and borrowed lights


Pass thru window 1 EA $4,526.35 $4,526
Interior glazing 520 SF $58.20 $30,262

Prepared by Cumming Sheet 16 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

Interior doors, frames and hardware


Solid core doors in hollow metal frames, including hardware and
paint finish
Single 35 EA $2,586.48 $90,527
Double 2 EA $4,655.67 $9,311

$682,308

7 Floor, Wall and Ceiling Finishes

Floors
Sheet vinyl 17,987 SF $7.76 $139,569
Ceramic tile 1,500 SF $17.46 $26,188
Sealed concrete 6,100 SF $1.94 $11,833
Sealed and polished concrete 4,500 SF $6.47 $29,098
Carpet 3,000 SF $5.17 $15,519

Bases
Rubber, tile, etc. 33,087 SF $0.65 $21,395

Walls
Ceramic tile at restrooms, 48" height 1,000 SF $18.11 $18,105

Ceilings
Suspended gypsum board, including framing and paint finish 12,100 SF $12.93 $156,482
Acoustical ceiling tile, 2'x2' 21,687 SF $4.53 $98,163

$516,353

8 Function Equipment and Specialties

Prefabricated compartments and accessories


Toilet cubicles
Standard, solid phenolic 12 EA $1,422.57 $17,071
ADA, solid phenolic 4 EA $1,681.21 $6,725
Urinal screens 6 EA $581.96 $3,492
Restroom accessories 1 LS $12,932.42 $12,932

Shelving and millwork


Fixed storage shelving 1 LS $15,518.90 $15,519
Display cabinets, bulletin boards, etc. 1 LS $19,398.63 $19,399
Janitors shelf and mop rack 1 EA $840.61 $841

Prepared by Cumming Sheet 17 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

Cabinets and countertops


Fixed reception desk 16 LF $840.61 $13,450
Vanity units, plastic laminate countertop 12 LF $206.92 $2,483
Laboratory casework (teaching labs) 6,705 SF $19.40 $130,068

Markerboards, signage, etc.


Marker boards, seminars / classrooms, porcelain enamel, 3 ply
backing including chalk rail, 16'-0" x 4'-0" 2 EA $3,362.43 $6,725
Markerboards, 4' x 3' 9 EA $387.97 $3,492
Markerboards, 10' x 4' 8 EA $775.95 $6,208
Room identification and code signage 33,787 SF $0.78 $26,217

Light control and vision equipment


Motorized projection screens, allowance, 6'-0" x 8'-0", electrically
operated 11 EA $5,560.94 $61,170
Projector mounting bracket 11 EA $969.93 $10,669
TV brackets 11 EA $517.30 $5,690
Mechoshade, manual 4,999 SF $11.64 $58,184

Amenities and convenience items


Fire extinguisher and cabinet 3 EA $517.30 $1,552

$401,886

9 Stairs and Vertical Transportation

10 Plumbing Systems

Sanitary fixtures 33 FX
Waterclosets 15 EA $1,681.21 $25,218
Urinals 5 EA $1,163.92 $5,820
Lavatories 10 EA $1,551.89 $15,519
Service sinks 1 EA $1,939.86 $1,940
Classroom sinks 2 EA $1,551.89 $3,104

Sanitary waste, vent and domestic service


Including floor drains, hosebibbs, cleanouts, water hammer
arrestors, sanitary waste/vent, domestic hot/cold water, valves and
specialties, insulation, backflow preventors 33 EA $6,466.21 $213,385

Prepared by Cumming Sheet 18 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

Water treatment and storage


Gas fired storage type domestic hot water heater, expansion tanks,
circulation pumps 1 LS $19,398.63 $19,399

Laboratory equipment
Standalone vacuum pumps, bottle racks, turret outlets, medical
piping, compressed air system, valves and specialties 1 LS $51,729.68 $51,730

Gas distribution
Including gas piping, valves and specialties, seismic shutoff valve 33,787 SF $0.86 $29,057

Surface water drainage


Including roof/overflow drains and drainage piping 33,787 SF $1.55 $52,434

Miscellaneous
Fire stopping/core drilling 1 LS $4,176.04 $4,176
LEED commissioning assistance 1 LS $12,528.13 $12,528
Miscellaneous Plumbing 1 LS $1,282.29 $1,282
Project requirements 1 LS $25,056.26 $25,056

$460,647

11 Heating, Ventilation and Air Conditioning

Heat and cooling generation


Connection to existing chilled water system 1 EA $6,466.21 $6,466
Connection to existing heated hot water system 1 LS $646.62 $647

Thermal storage and circulation


Air separator Not Required
Expansion tank Not Required
Heated hot water pumps Not Required
Condensate pump Not Required
Variable frequency drives Not Required
Vibration isolation Not Required

Piping, valves and insulation


Including heating hot water, chilled water, refrigerant piping,
insulation, valves and specialties 33,787 SF $4.53 $152,932

Air handling equipment


Air handling units, including hc, cc, filters, sf, rf, vfd
AHU-1,2) 9,500 cfm 2 EA $61,428.99 $122,858

Prepared by Cumming Sheet 19 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

AHU-3) 5,000 cfm 1 EA $32,331.05 $32,331


Terminal boxes, w/reheat coils 2 EA $3,879.73 $7,759
AHU-4) Split DX fan coil system, 2 1/2 tons 1 EA $16,165.52 $16,166
Sound attenuation Not Required

Air distribution and return


Galvanized sheetmetal ductwork, supply and return 32,000 LBS $13.64 $436,598
Flexible ductwork 1,500 LF $16.81 $25,218
Volume dampers 300 EA $64.66 $19,399
Combination fire/smoke dampers 1 LS $45,263.47 $45,263
Duct insulation 24,615 SF $3.23 $79,584
Acoustical lining Not Required

Diffusers, registers and grilles


Including thermafusers, exhaust grilles, sound boots 33,787 SF $2.59 $87,390

Controls and instrumentation


Including direct digital controls, CO2 monitoring, LEED monitoring
points, BACNET 33,787 SF $6.47 $218,474

Testing and balancing 33,787 SF $1.55 $52,434

Unit ventilation
Including galvanized sheetmetal ductwork 500 LB $13.64 $6,822
General rooftop exhaust fans, 5,300 cfm 1 EA $6,466.21 $6,466
Vehicle exhaust 1 LS $77,594.52 $77,595

Miscellaneous
Fire stopping/core drilling 1 LS $13,944.01 $13,944
LEED commissioning assistance 1 LS $7,511.08 $7,511
Miscellaneous HVAC 1 LS $3,755.54 $3,756
Project requirements 1 LS $11,615.90 $11,616

$1,431,228

Prepared by Cumming Sheet 20 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

12 Electrical Lighting, Power and Communications

Main normal power


Connection to existing manhole EMH-30 in parking lot G 1 EA $6,466.21 $6,466
15.5kV, 4way, SF6 gas selector switch 1 EA $19,398.63 $19,399
4.16KV-480/27&V transformer substation, 300kVA Existing
Main distribution switchboard, 480/277V, 600A 1 EA $21,726.47 $21,726
Digital metering 1 LS $7,759.45 $7,759
Transformer, 480V-120/208V, 150KVA 1 EA $14,548.97 $14,549
Distribution panel, 120/208V, 225A 1 EA $8,147.42 $8,147
Panelboards, 480/277V, 100A 1 EA $4,526.35 $4,526
Panelboards,120/208V, 100A dedicated to lab 5 EA $4,526.35 $22,632
Panelboards,120/208V, 100A 2 EA $4,526.35 $9,053
Feeder conduit and cable 450 LF $129.32 $58,196

Emergency power - central lighting inverter 1 LS $15,518.90 $15,519

Machine and equipment power


Including HVAC equipment connections, elevator connections,
automatic doors, VAV terminals, kitchen equipment, miscellaneous,
feeder conduit and wire 33,787 SF $2.59 $87,390

User convenience power


Including receptacles, j-boxes, floor boxes, GFI, switches, feeder
conduit and wire 33,787 SF $7.76 $262,169

Lighting
Including fixtures, emergency and exit lighting, exterior wall mounted
lighting, switches, occupancy sensors, photocells, feeder conduit
and wire 33,787 SF $15.52 $524,337

Power specialties
Including grounding, lighting control panels, etc 33,787 SF $0.84 $28,402

Telecommunications
Including telephone/data outlets - conduit and cable, terminal
backboards IDF/MDF, conduit backbone, wireless access terminals,
cable tray 33,787 SF $10.35 $349,558

GPS clock system 33,787 SF $0.45 $15,293

Audio/visual - conduit only 33,787 SF $0.65 $21,847

Prepared by Cumming Sheet 21 of 22


Crafton Hills College - OE2 Replacement
San Bernardino Community College District
Yucaipa, California
Rough Order of Magnitude Statement of Probable Cost May 5, 2011

F. New Construction Construction Component Detail

Element Quantity Unit Unit Cost Total

Fire alarm system


Including main fire alarm panel, annunciator, smoke detectors, heat
detectors, horns, strobes, horn/strobes, manual pull stations, tamper
switches, power supply, feeder conduit and wire
33,787 SF $4.53 $152,932

Security
including access control, intrusion detection, CCTV monitoring,
command center, conduit and wire 33,787 SF $3.23 $109,237

Miscellaneous
Fire stopping/core drilling 1 LS $17,391.37 $17,391
LEED commissioning assistance 1 LS $52,174.11 $52,174
Miscellaneous Electrical 1 LS $1,609.80 $1,610
Project requirements 1 LS $104,348.22 $104,348

$1,914,660

13 Fire Protection Systems

Automatic wet sprinkler system 33,787 SF $5.82 $223,268

$223,268

Prepared by Cumming Sheet 22 of 22


California Community Colleges
COST ESTIMATE SUMMARY AND ANTICIPATED TIME SCHEDULE - JCAF 32
Final Project Proposal
District: San Bernardino Community College District College: Crafton Hills College CFIS Ref. No.:
Project Name: New Emergency Services (OE-2) Date Prepared: 7/1/2011 CCCI: 5394 Budget Ref. No.:
Request for: A P W C E EPI: 3016 Prepared by: Maas Companies
Locally Funded State Funded Total
Non-State (Locally Funded State-Supportable
Supportable State-Supportable + State Funded only)
1. Site Acquisition Acres:
A. Purchase Price of Property
B. Appraisals
C. Costs Incurred in Escrow
D. Surveys
E. Other Costs $ - $ - $ -

2. Plans and Working Drawings


(Total may not exceed 13% of construction costs)
A. Architectural Fee for Preliminary Plans $ 145,029 $ 145,028 $290,057
B. Architectural Fee for Working g Drawings
g $ 186,465 $ 186,466 $372,931
C. Project Management $ 51,796 $ 51,796 $103,592
D. Div of the State Architect Plan Check fee $ 30,234 $ 30,234 $60,468
E. Community College Plan Check fee $ 14,814 $ 14,813 $29,627
F. Preliminary Tests (soil tests) $ 15,974 $ 15,975 $31,949
G. Other Costs $ 21,299 $ 21,299 $42,598
465,611 465,611 $931,222 $ 931,222
3 Construction
3.
A. Utility Service $ 90,500 $ 90,500 $181,000
B. Site Development, Service $ 175,000 $ 175,000 $350,000
C. Site Development, General $ 269,000 $ 268,000 537,000
D. Other Site Development (Re-Landscaping) $ - $ - $0
E. Reconstruction $ - $ - $0
F. New Construction (Bldg.)
( g ) ((w/Group p I equip)
q p) $ 4,375,631
, , $ 4,375,631
, , $ , ,
$8,751,262
G. Other (Energy Program) $ 4,909,631 $ 4,909,631 $539,933 $ 9,819,262
H. Temporary Facilities ("Swing Space") $1,672,000
4. Tests $ 51,796 $ 51,796 103,592
4a. Inspections $ 76,853 $ 76,853 $153,706
5. Contingency $ 258,980 $ 258,980 517,960
6. Construction Management (if justified) $ 103,592 $ 103,592 $207,184
7 A
7. Architectural
hit t l and dE Engineering
i i O Oversight
i ht $ 82 873
82,873 $ 82
82,874
874 $165 747
$165,747
8. Total Construction Costs (items 3 through 7) $ 5,753,692 $ 5,753,692 $11,507,384
9. Furniture and Group II Equipment $ 397,641 $ 397,640 $795,281
10. Total Project Cost (items 1, 2, 8, and 9) $ 1,672,000 $ 6,616,944 $ 6,616,944 $ 13,233,887
Outside Gross Assignable Ratio Cost Cost District Funded State Funded
11. Project Data Square Feet Square Feet ASF/GSF Per ASF Per GSF
Construction 33 100
33,100 22 168
22,168 67% $ 395 $ 264 Acquisition NA NA
Reconstruction Preliminary Plans $ 223,449 $ 223,448
12. Anticipated Time Schedule Working Drawings $ 242,162 $ 242,162
Start Preliminary Plans 9/1/2013 Advertise Bid for Construction 9/1/2014 Construction $ 5,753,692 $ 5,753,692
Start Working Drawings 12/1/2013 Award Construction Contract 10/1/2014 Equipment $ 397,640 $ 397,641
Complete Working Drawings 3/1/2014 Advertise Bid for Equipment 4/1/2015 Total Costs $ 6,616,943 $ 6,616,944
State Architect ((DSA)) Final Approval
pp 8/1/2014 Complete
p Project
j 11/1/2015 % of Project
j Costs 50% 50%
California Commuity Colleges
Final Project Proposal

Energy Use Calculator

District: San Bernardino Community College


College: Crafton Hills College

Fiscal Year Ann. Electrical Electricity to Annual Natural Gas TU Total Annual Gross Square Feet Weeks of Total Weeks Percent Reduction of Baseline Year
KWH Usage BTU Conversion Therm. Usage BTU's Consummed from Space Inv. Academic. Ops. of Operation Average BTU's Per GSF Per Week
2001-2002 3,704,018 12,641,813,434 99,402 22,582,013,434 $208,172 $ 44 51 2284 Baseline Year
2002-2003 3,495,729 11,930,923,077 99,813 21,912,223,077 208,172 $ 44 51 2216 -2.97%
2003-2004 3,363,566 11,479,850,758 84,941 19,973,950,758 219,212 $ 44 51 1918 -16.00%
2004-2005 2,696,955 9,204,707,415 67,826 15,987,307,415 $224,787 $ 44 51 1497 -34.44%
2005-2006 3,098,490 10,575,146,370 73,353 17,910,446,370 $224,787 $ 44 51 1677 -26.55%
2006-2007 3,362,580 11,476,485,540 75,406 19,017,085,540 $224,787 $ 44 51 1781 -22.01%
2007-2008 3,302,037 11,269,852,281 84,446 19,714,452,281 $224,787 $ 44 51 1846 -19.15%
2008-2009 3,222,798 10,999,409,574 66,406 17,640,009,574 $224,787 $ 44 51 1652 -27.66%
2009-2010 3,496,058 11,932,045,954 87,148 20,646,845,954 $224,787 $ 44 51 1934 -15.33%

Instructions Used for Completion of Calculations:

1. Enter your electric and gas usage for 2001-02 and subsequent years. The spreadsheet will calculate your annual Btu use.
2. Enter your campus gross square footage from Space Inventory. Remove square footage that does not use electricity or gas.
3. Enter your normal weeks of Academic Operation.
4. Enter your total weeks of operation (add the Non-Academic Weeks of Operation to the Academic Weeks of Operation = 52 or less).
5. You are done. Save, print and send in with your 5YP & FPP. Since this is being submitted with your 5YP, your energy use data will be from the previous FY.
Other data should correspond as closely to this previous FY as possible.

This chart was created to allow campuses to add academic weeks without being penalized for the additional energy those weeks would add to the normal
calculation of the Energy Utilization Index (EUI); which is the Btu/sq. ft./year. In the normal calculation, the energy use would increase, but the square footage
would remain constant, thus resulting in a higher EUI. By factoring in the weeks of operation, the increase to the EUI is diluted.

There is the presumption that a Non-Academic Week uses about 50% of the energy of an Academic Week, therefore only half of the difference between the
number of Academic Weeks and the Total Weeks is added to the Academic Weeks to determine the 'total weeks' of operation for the calculation of the
Average Btu/GSF/Week.
California Community Colleges
Final Project Proposal

CALIFORNIA ENERGY COMMISSION APPROVED AUDIT

The District has a current, on-going Energy Management Program in place. The program has
been in place since 1992 and is reviewed annually. With the passage of two local bond
measures, the district has upgraded the existing campus infrastructure to meet the energy
needs for all new facilities included in the campus master plan. This project is included in the
master plan and will be integrated into the existing campus-wide Energy Management System.
California Community Colleges
Final Project Proposal

RESPONSES TO SPECIFIC REQUIREMENTS OF THE


STATE ADMINISTRATIVE MANUAL

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

A.1 EXECUTIVE SUMMARY


In accordance with the college’s 2008 Educational Master Plan, and as updated as part of the
College’s 2010 Accreditation Self-Study, this project, a new Emergency Services Building,
creates a new, or replacement, facility as proposed as part of the current Facilities Master Plan
for the campus. Previously approved, and included in the Master Plan, are the Learning
Resource Center (LRC), Humanities Building and Science Building. The proposed scope of this
project is a 22,168 asf/33,100 gsf Emergency Services (OE-2) building comprised of primarily
laboratory space for instructional programs in the 2100 and 1200 TOP Codes, Public Services
and Health instructional areas. This project replaces all existing space (15,730 asf) in the current
OE-2 Building (Space Inventory Building # 7). In addition, the project includes space for related
instructional programs currently housed in classrooms throughout other buildings on the campus.
The proposed Emergency Services (OE-2) building will provide a central location on the campus
for all Public Service programs and related health occupational programs associated with
emergency services and general education classes in the current space occupied by these two
programs. This facility is the first new facility for occupational education for the campus in over
35 years. It will be the central instructional facility for public services, emergency services and
related health occupation programs for the Redlands-Yucaipa service area. The proposed
funding for the project is 50% local funds and 50% state funds.

A.2. PROBLEM STATEMENT:


The problem to be addressed by this project is to provide sufficient instructional space for the
present and future Emergency Services and related Health Occupation programs offered by the
College. The existing facility, which will be demolished as part of this project, was constructed
to house vocational/occupational programs in 1975. It has been remodeled and modified over
the past 30 years to adapt to changing curriculum and program growth. The facility is
undersized in terms of space and can no longer be remodeled to meet the ever-increasing student
enrollment in the Public Service programs. As a result, the presence of an inadequate facility is
affecting the curriculum of the College. Crafton Hills College is located in Yucaipa, California,
a very high growth area of San Bernardino County. While other areas throughout the
surrounding area have shown a decline in population, the College’s service area continues to
consistently have an annual growth rate of over 8%. According to the District’s 2010 Long
Range Enrollment and WSCH Forecast prepared by the California Community College
Chancellor’s Office, Student enrollment and Weekly Student Contact Hours (WSCH) for the

1
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

College is expected to increase by more than 47% from 80,380 WSCH in 2010 to 118,031
WSCH in 2017. The college has maximized its current facilities and cannot offer additional
classes to meet this ever-increasing demand from residents of the service area. Even with
limitations on funding, the college has expanded its instructional program into the late afternoon,
evening and weekends to address this unmet need. The long-term growth in student enrollment
for the District will be at Crafton Hills College. This project will assist in addressing the need
for additional facilities to accommodate this growth. The table below depicts the space array for
the proposed new facility and its associated capacity-load ratios.

SPACE ANALYSIS (ASF) FOR THE Emergency Services (OE-2) PROJECT


Type Lecture Lab Office Library AV/TV Other Total
Primary 6,290 9,318 1,450 0 0 5,110 22,168
Secondary -3,863 -1,673 -1,332 0 0 -5,427 -12,295
Net 2,427 7,645 118 0 0 -317 9,873
Beg. Cap/Load Ratios (2013) 79% 54% 99% 164% 84% N/A 91
End. Cap/Load Ratios (2017) 115% 90% 102% 139% 89% N/A 109

A.3. SOLUTION CRITERIA

This project will provide the following benefits to the academic program:
• Assists in addressing the shortage of campus-wide instructional lecture and laboratory
space at the college and specifically in the areas of Emergency Services, Public
Services and Health.
• Assists in addressing the instructional space needs associated with enrollment growth
of the college.
• Provides modern, up-to-date facilities which are more adaptable for new instructional
strategies.
• Provides facilities to support the joint educational programs between the college and
public agencies in the College’s service area.

In analyzing the possible solutions to the problem of inadequate instructional space for
the Emergency Services and related Health and Public Service programs, the following
strategies or options were considered as the basis for development of the project
alternatives:
• Limit the number of instructional offerings in these instructional areas based on the
existing instructional space. This solution will have the outcome of limiting the
enrollment of the College and not addressing the demand for additional classes or
meeting the employment needs of public agencies in the College’s service area

2
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

• Maximize the extended day and weekend instructional offerings. This solution has
the outcome of meeting the short-term needs of the program but has a finite limit
based on the current capacity and quality of the existing facilities.

• Identify off-campus locations that could be used for additional instructional


offerings. Include in this assessment the potential of establishing a joint-venture
with other public or a private nonprofit agency to provide affordable space at off-
campus locations. This solution has the outcome of providing the needed additional
space at an off-site location but has a corresponding negative outcome of
discouraging students to become full-time students due to the inconvenience of
attending multiple locations.

• Reduce the instructional offerings in other areas of the curriculum and assign the
space obtained from the reduction to the Public Services programs. This solution is
viable for the Public Services programs but, at the same time, creates an outcome
that skews the overall instructional program. It is an outcome that would require the
College to address the issue of what is the balance in curriculum appropriate for the
College and residents of the service area.

• Consider adding temporary (Portable) facilities on the campus to address the short-
term need for additional space. The addition of temporary facilities is a short term
solution. The outcome is that you have the necessary space but has not addressed the
original problem of insufficient, permanent space for the Public Services
instructional programs.

A. RELATIONSHIP TO THE STRATEGIC PLAN:


Crafton Hills College completed its initial College Master Plan in 1992. This initial Master
Plan has been regularly updated by the faculty, staff and consultants with the latest update
occurring during the 2010-11 academic year. The current Master Plan was prepared as part
of the recently completed Accreditation Self-Study and is an integral part of the decision-
making process at the College. It is the basis for the prioritization of capital construction
projects.

The Master Plan addresses the long-term enrollment projection for the college and the
corresponding projection of the instructional program to meet the needs of the proposed
enrollment. The Emergency Services (OE-2) project is the first, new, instructional project
that is proposed to address the need for additional occupational/technical space based on the

3
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

campus. The College’s continued growth in enrollment validates the projections proposed in
the Master Plan and the Final Project Proposal (FPP) presented for this project.

The Solution Criteria lists options the College addressed in developing the
Educational/Facilities Master Plan and the accompanying requests for funding of the
proposed project. If the proposed project is funded, then the College will have taken the next
step in implementing the Educational/Facility Master Plan recommendations.

This facility will address the recommendation to integrate the use of technology into all
elements of the College’s instructional and support service programs. The desired outcome
is that this building will serve as a key facility for the continued growth and expansion of the
Public Services instructional program for residents of the College’s service area. It is a
critical element in the joint development of Public Service programs for all public entities in
the greater Redlands/ Yucaipa area of the District.

Without it, the college will be restricted in its effort to accommodate student growth, will not
be following the recommendations in the Master Plan and will not be able to provide the
necessary instructional programs required to be a viable institution of higher learning in one
of the fastest growing region in California.

B. ALTERNATIVES:
As part of the preliminary planning for this project, the College considered a number of
potentially viable alternatives. Non-viable alternatives, such as limiting the number of
instructional offerings and reducing the number of instructional offerings in other areas of the
curriculum to allow the Public Services programs to expand were not pursued following the
initial assessment of options.
Further complicating the problem is that the existing campus buildings are more than 35-
years old and were constructed in a manner that makes it fiscally and physically very difficult
to modify/remodel the existing size or re-configure the interior spaces in the existing
buildings. This inflexibility of the current facilities has a significant impact on the capacity
load ratios for the College and creates a false expectation that there is space available that is
not being used in the lecture and laboratory categories. A visual inspection of the buildings
confirms the problem with many of the current classrooms and laboratories in that they are
inappropriately sized to accommodate the larger class sizes needed to efficiently offer the
College’s instructional programs and/or the implementation of technology to support today’s
learning systems.

4
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

The project alternatives that may be viable are as follows:


1. Construct a new Emergency Services (OE-2) Building in accordance with the
Educational & Facilities Master Plan.
2. Lease or jointly develop with other public agencies an off-campus facility for additional
instructional space for the Emergency Services and related instructional programs.
3. Use a temporary or portable facility to house the Emergency Services and related
instructional programs.
4. Remodel an existing building to accommodate the proposed Emergency Services and
related instructional programs.

The detailed analysis of these alternatives is as follows:

1. Construct a new Emergency Services (OE-2) Building in accordance with the


Educational & Facilities Master Plan

As shown on the Facilities Master Plan for the campus, the ideal location for the new,
proposed building is the current location of the present Emergency Services (OE-2)
facility (Space Inventory Building #7). This location requires the College to provide
interim or “Swing Space” as may be necessary to house the instructional programs during
the construction of the demolition and construction of the new building. In recognition of
this additional cost, the District is proposing that the cost of the “Swing Space” which is
anticipated to be as many as seven (7) temporary structures @ 960 gsf per modular, be
paid solely by the District as a non-state supported expense. The cost is estimated at
$1,671,500 and will be implemented, if needed, prior to the commencement of this
project. Under this alternative, the proposed new Emergency Services building is
designed as part of the new, vocational education core of the campus with convenient
access to the LRC and student service areas.. This alternative is the most cost-effective
solution for providing a new, permanent facility for the Emergency Services (OE-2)
instructional program.

Scope of the Alternative: The scope of this alternative is to construct a new, 22,168 asf
building to house the Emergency Services and related health and public service
programs. The existing OE-2 facility will be demolished. This project will anchor the
College’s commitment to a new, vocational education complex located at the Southeast
entrance to the campus. It will have the capacity to house all Public Service programs in

5
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______
a central, highly visible location and will highlight the changes the College is making to
attract and accommodate new students and for the campus and to be a more viable part of
the community. It will address the space needs for the Public Services and related Health
and Emergency Services instructional programs through the year 2025 as outlined in the
Educational and Facilities Master Plan for the College.

Academic Program Impact: The proposed facility will help the college meet the
instructional space needs for the campus through the year 2025. No additional space will
be required for the Public Services and Health/Emergency Services programs. It will
allow the College to offer the curriculum, as designed and projected as part of the master
planning process, through 2025.

Facility Management Benefits: The upkeep and maintenance of the new facility may
require the College to slightly increase the level of staffing for custodial and maintenance
staff but this may be off-set by the design elements of the new facility and its
infrastructure. Since this is a new facility, the costs for major repairs and renovation will
not have a significant impact for the next 7-10 years. This option is consistent with the
Facilities Master Plan for the revitalization of the campus.

Source of Financing: The new facility is proposed as a 50% state and 50% local bond
funded.

2. Lease or jointly develop with other public agencies an off-campus facility for additional
instructional space for the Emergency Services and related Public Services programs.
This alternative is an option in term of economics, but one that does not seem to be viable
in terms of the instructional program for a comprehensive community college. The
Public Services instructional programs need to be an integral part of the campus learning
environment and are proposed as the central link to the majority of all vocational
programs offered by the College. As such, the facility must be strategically placed at a
highly visible, readily accessible location on the campus. There are significant
ramifications of locating the program off-campus not the least of which is the
disintegration of a comprehensive community college curriculum. However, if an off-
site location became necessary the following information would serve as the basis for
planning such a facility

Scope of the Alternative: The scope of the project is to develop a joint-venture with
another entity a 22,168 asf/33,100 gsf facility off-campus. The facility would be
identical to the proposed on-campus facility except that it would be at an off-campus

6
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

location. A joint venture, public services partner such as a County or a City, who has a
building site for the proposed facility, would need to be included as the joint venture
partner.

Academic Program Impact: Locating the facility off-site will allow the college to expand
the course offerings pursuant to the Educational & Facilities Master Plan. However, it
would have the impact of requiring students to attend core curriculum classes at more
than one location. This would create scheduling problems for students and increase the
probability of students taking fewer classes in a given semester thus reducing the
WSCH/FTES ratio for the College.

Facility Management Benefits: The benefits listed in Alternative One would also be
appropriate for this option. However, since it is an off-campus location, the logistics of
maintenance and support services will have an additional impact on the operating budget.

Source of Financing: The funding for the project would have to be from sources other
than the state and operating fund of the College. Subject to available funding, options
could involve the lease-purchase of the site and the building from a private partner.

3. Use a temporary or portable facility to house the Emergency Services (OE-2)


Instructional program.
This alternative has merit if one is willing to accept a short-term, rather than a long-term,
solution to the problem. It is cost-effective in that the temporary facility could be
acquired on a lease/purchase basis utilizing operating funds and/or local bond funds of
the District.

Scope of Alternative: The proposed facility would be a 33,100 gsf temporary building.
Contained in the facility would be the same number of instructional spaces as proposed
for a permanent facility.

Academic Program Impact: If located on-campus, the impact would be that the College
has space to immediately expand the curriculum offering in Emergency Services and
related programs such as Health and Public Services. The long-term impact would be that
the programs housed in the facility will never be considered an integral part of the
campus. Students will have that perception typically associated with temporary facilities
of being on-campus but not quite equal to a permanent facility. This could lead to a
lower than expected enrollment in classes scheduled in the temporary facilities. Another
negative impact is that temporary facilities are also inconsistent with the master planning
of the campus.

7
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

Facility Maintenance Benefits: Initially, the upkeep and maintenance will be minimal.
As the facility ages, there will be a need to upgrade and maintain the facility which will
have a greater than normal impact on the operating budget of the college. Temporary or
portable facilities do not provide a long-term solution for projects listed in the Facilities
Master Plan. They provide a short-term solution that is not eligible for state funding.

Source of Financing: The purchase of the facilities would require using operating funds.
Given the current level of funding from the state, it is not possible for the District to fund
the project from its general operating fund.

4. Remodel an existing building to accommodate the proposed Emergency Services


(OE-2) program.
This Alternative proposes to use space in an existing facility on campus. All existing
buildings on the campus have on-going instructional programs housed in them that would
need to be relocated or eliminated if this alternative were selected.

Scope of Alternative: Locate 22,168 asf of space in an existing, on-campus facility. This
may not be viable but it is an alternative that needs preliminary assessment. There are no
vacant buildings on campus. To move the Emergency Services program into a building
would result in the displacement of the current instructional programs housed in that
facility. A review of the capacity load ratios for space on the campus indicates the
College has no excess lecture or laboratory space. Therefore, the capacity load ratios for
the College would be projected to an even lower level than what currently exists.

Academic Program Impact: Eliminating instructional classes in another facility to make


room for Emergency Service programs will result in a net reduction in the number of
class offerings and a corresponding decrease in student WSCH.

Facility Management Benefits: Since this option would result in a remodeled facility,
major repair and maintenance costs would not have a significant impact for the next 7-10
years.

Source of Financing: The remodel of an existing building could be accomplished using a


combination of local funds and state funds similar to the 50%/50% formula proposed for
the new facility.

8
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______
SUMMARY OF ALTERNATIVES –CRITERIA ANALYSIS

Criteria Alt. #1 Alt. #2 Alt. #3 Alt. # 4


Permanent Facility Yes Yes No Yes
Consistent with Master Plan Yes No No No
Benefits Inst. And Support Services Yes No No No
Minimizes Increase in Op. Budget Yes No No No
Programs/Services in one location Yes No No Yes
Access Compliant Yes Yes Yes Yes
Improves Capacity Load Ratio Yes No No Yes

SUMMARY OF ALTERNATIVES -- ECONOMIC ANALYSIS


Category Alt. #1 Alt. #2 Alt. #3 Alt. # 4
(Replace- (40 yr. (Lease) (Lease/Purchase (Remodel
Expand) Temp. Units) Other Space)
Utility Services $181,000 $0 $88,000 $375,000
Site Development, Service $350,000 $0 $45,000 $323,000
Site Development, General $537,000 $0 $148,000 $475,000
Site Development, Other: $0 $0 $50,000 $420,000
Grading, Temp. Footings, (Included in (Grading,
Anchors, Permits etc. Lease) materials
Footings)
Soft/Support Costs: A/E, Tests, $2,620,000 $500,000 $220,000 $5,380,000
Insp., Mgt Allow, etc.
Reconstruction $0 $0 $0 $6,125,000
New Construction** $8,751,000 $0 $0 $9,000,000
Parking (200 Spaces) $0 $1,050,000 $0 $0
Plus—Ground lease for parking (Initial
area and facility site Construction
Cost @
$1,700/space +
Grd. Lease
Group II Equipment $795,000 $795,000 $795,000 $795,000
Facilities Lease or Lease-Own, $0 $23,800,000 $1,035,000 $0
Delivery, Install/const. 40-Yr. Lease
Total Project Cost @ $13,234,000 $26,145,000 $2,381,000 $22,893,000
CCCI 5065 & EPI 2894

9
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15

ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

Notes:
The Cost analysis for Option 1 is the proposed JCAF-32 for the project
The cost analysis for Options 2-4 are as follows:
A. Option 2: Off-campus, Joint-venture, Leased Facility:
1. Assume a 40-Year lease including building and parking to accommodate 200 students,
faculty and staff.
2. Construct the building in accordance with the JCAF-31 proposed for the project (22,168
asf/33,100 gsf) with all tenant improvements included.
3. Assume the parking formula will be 125 Vehicles/acre. Therefore, 1.6 acres will
be needed for parking. The cost of land for parking will be included in the lease
payments. The capital cost for parking improvements will be $1,700/space or
$340,000.
4. The 22,168 asf/33,100 gsf facility will require 0.9 acres of property.
5. The total site acreage with be 2.5 acres.
6. The facility will be built to DSA/CBC standards
7. The lease payment schedule will be a 40-year schedule with 3-year incremental adjustments of
10% in the lease rate.
8. The lease will not include the on-going cost of utilities or the cost of equipment. These costs
will be paid by the College.
9. The baseline factors for the lease are as follows:
a. The basic ground rent will be 8.0%/year of the land cost of $80,000/acre =
$6,400/acre or $12,800/year for the 2.0 acre site or $38,400 for the first three
years of the lease period. The ground rent for the 2.0 acre site for the 40-year
lease period, assuming the 3-year escalation factor, would be $712,000.
b. The basic cost for parking improvements will be $1,700/space or $340,000 for 200 spaces.
c. The base lease rate for the building will be ($1.30/gsf/month)(33,100 gsf) = $43,000/month
or $516,400/year for the first three years of the lease.
d. The total lease cost for the initial 3-year lease (Building & Parking) = $1,664,300.
e. If the lease payment is adjusted by 8.0% every three years for the 40-years of the
lease, then the total lease payment over the 40-year life of the lease would be

10
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15

ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

$23,800,000 plus equipment costs of $795,000 and “soft costs” of $500,000 for the
40-year lease period for a total project cost of $26,145,000.
(Note: This cost estimate does not include potential renegotiation of lease terms,
remodel costs or equipment replacement costs over the 40-year period)
10. Total Project Cost = $25,095,000

B. Option 3-Temporary/Modular Facility


a. Cost of a 960 gsf temporary/modular building is $45,000/unit.
(Based on a cost estimate from GE Capital Corporation. 23 Modular Units would be
required to construct the amount of square footage (asf) proposed for the project.
The cost of the 23 modular units is: (23 units)($45,000/unit) = $1,035,000
b. Delivery and setup on prepared site on temporary foundations is (23 Units)($13,500/unit) =
$310,500
c. The cost for site improvements including utilities, pedestrian access, drainage, etc. =
$331,000
d. Soft costs including permits, architectural fees, engineering fees and management fees is =
$220,000
e. The cost for equipment is in accordance with the JCAF-33 for the project = $795,000.
f. Total Project Cost: $2,381,000.
Note: The Total Project Cost is for initial construction only and has not been
projected for a typical 40-Year life cycle for a capital construction project.

C. Option 4:-Remodel another Existing Facility on the campus—(Note: Renovating other


space on campus will displace the programs currently in that space and require a 1:1
replacement ratio for new construction. Therefore, 22,168 asf of new space will need to be
constructed for the displaced instructional programs.)
a. Site improvement costs for this alternative are slightly greater than the costs for
constructing only a new facility as this alternative requires renovation/demolition of
an existing building plus the construction of a new 22,168 asf facility to
accommodate the programs displaced by the relocation of the Emergency Services
programs. Total site improvement costs for this option are estimated at $975,000.

11
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15

ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

b. The cost of renovating the existing space is estimated at 70% of the cost of new
construction or $6,125,000 assuming similar classroom, laboratory and office
configurations and as based on the CCI 5394 Table of Costs.
c. The cost for replacing 22,168 asf of space in the existing building with new space is
essentially the cost of constructing the proposed project. However, due to differences
in the existing space in terms of disciplines and room use, the cost is slightly more
than the proposed new building. Based on CCI 5394 guidelines, the construction cost
for the new, replacement building is estimated at $9,000,000 or $406/asf.
(Construction costs only).
d. The equipment costs for this option are the same as for all options proposed for this
project with a cost of $795,000 as calculated from the JCAF-33 for the project. No
new equipment is budgeted for the programs that would be relocated.
e. The total time line for the option of a new facility plus the renovation project will be
approximately 14 months longer than if only a new facility were constructed as the
new facility would need to be built and occupied before the existing building could be
renovated. As an option, the concept of using temporary facilities to house the
programs that are to be relocated is presented. The cost for the temporary facilities is
estimated at $2,700,000. This cost would be off-set by the additional management,
supervision, general conditions and inspections associated with the longer
construction period. Using temporary facilities will reduce the overall timeline for
the project back to approximately a 12 month schedule saving the additional costs
associated with the extended construction period and the disruption to the educational
program at the College.
** All construction calculations based on CCI 5394 and EPI 3016.
f. Total Project Cost: $22,893,000

C. RECOMMENDED SOLUTION:
1. Which alternative and why?
The recommended solution is Alternative 1--to construct a new Emergency Services
(OE-2) Building. The reasons for selecting this alternative are as follows:

a. It is the most cost effective alternative for a permanent facility that is consistent with
the College Educational & Facilities Master Plan.

12
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

b. In the long-term, it is the most cost-effective solution because the cost of renovating
an existing facility to Title 5/Title 24 standards, plus the secondary effects (new
facility), is greater than the cost of just constructing a new facility for the proposed
programs.

c. It provides the best solution for the delivery of the Emergency Services and related Public
Services curriculum.
d. It provides the physical space necessary to support the efforts of the college to
respond to the increase in student enrollment and will have limited impact on the
students and faculty in terms of day-to-day activities on the campus.
e. A temporary unit provides a short-term solution but is not compatible with the
long-term Educational & Facility Master Plan for the College.

f. A new facility will result in only a limited increase in the operational budget for
the College and these costs will be covered by the increase in FTES generated by the
instructional programs.

A. Detail Scope Description.


This project will construct a new, 22,168 asf on the site of the present OE -2 facility near
the Southeast entrance to the Campus. The project will be designed to be compatible
with other new facilities being developed as part of the facilities master plan. This
building will be part of the focal point of the new instructional spine for the campus. The
detailed breakdown of the building spaces is as follows:

13
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

Building Space Allocation


Project
TOPS
Type Code Description/Department Space ASF
50 99 Inactive-General Assignment
110 1201 Classroom-General Assignment 6,290
210 1200 Laboratory-Health Occupations 1,350
210 2100 Laboratory-Public & Protective Services 4,050
215 2100 Lab. Serv.-Public & Protective Services 830
215 4900 Lab. Serv. Interdisciplinary Studies 400
220 2100 Special Class Lab.-Public/Protect. Serv. 1,200
230 4900 Ind. Studies Lab.-Interdisciplinary Studies 1,488
310 99 Office-General Assignment (Faculty) 1,080
310 6000 Office-Instructional Administration 160
315 99 Office-Service 210
680 99 Meeting Room 990
740 2100 Vehicle Storage-Public/Protective Serv. 4,120
Total ASF 22,168
Total GSF 33,100

B. Basis for cost information.


a. Cost estimates were developed by engineering and construction management
professionals currently working on projects in the Inland Empire area and also using
recently completed community college projects. Costs for temporary facilities were
obtained from the manufacturer. Site preparation costs were obtained from similar,
recently completed community college projects. The cost for leasing was obtained
from the local Board of Realtors.

b. The District will use the energy incentive allowance to design the proposed to a
minimum of LEED “Silver” rating. The 2% energy incentive for this project will be
used to assist in reaching this goal through funding of energy efficiency measures.
Energy efficiency measures to be considered include:

• Design, installation and operation of efficient HVAC systems


• Conformity of windows and doors to LEED standards
• Building envelope design that facilitates energy conservation

14
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

• Orientation of building and design of exterior design to reinforce energy


conservation guidelines.
• Installation of landscaping that reduces water and energy operational costs.
• Use of renewable energy systems such as solar where possible to reduce the
energy requirements for the facility.

Factors/Benefits for Recommending Project Other Than the Least Expensive Alternative.
As noted previously, the recommended alternative is the only alternative that is consistent
with the Facilities Master Plan for the college, is the best facility solution to meet the
needs of the instructional and support services of the College, and is the best solution to
meet the long-term instructional and technology needs of the College.

As discussed in Section C—A Alternatives, the least expensive economical solution is


not always the best long-term decision. In this case, the use of temporary, portable
facilities is the least expensive alternative. Unfortunately, it is not a viable solution
because it does not address the long-term facility needs for a modern, technology-based,
vocational education facility. It also does not address the operational costs, aesthetic
impact, or the political ramifications of building a temporary structure rather than
permanent facilities.

c. Complete description of impact on support budget.


The proposed project does not increase the number of certificated staff assigned to the
programs and services proposed for this building. Staff will, however, have efficient
and ergonomically sound work spaces, which should result in better overall
efficiency. Therefore, there will be no additional costs directly attributable to this
project.

d. With respect to maintenance and operations, this project will add 9,873 assignable
square feet of space to the college inventory. Historical data indicates that this new
facility will not impact the deferred maintenance program until 2021. Because this is
a new facility, the design and construction will be in accordance with modern, energy
efficient systems and materials. This design should minimize the day-to-day
operating costs of the building.

15
California Community Colleges
Final Project Proposal

STATE OF CALIFORNIA DEPARTMENT OF FINANCE


CAPITAL OUTLAY 915 L. Street
BUDGET CHANGE PROPOSAL (COBCP) Sacramento, CA 95814
BUDGET YEAR 2013-2014 IMS Mail Code: A15
ORG CODE: ______ COBCP NO:______ PRIORITY:______ PROJECT ID:______

e. Identify and explain any project risks.


The only risk associated with the project would be unknown underground conditions
that exist on the proposed building site.

f. List requested interdepartmental coordination and/or special project approval


(including mandatory reviews and approvals, e.g. technology proposals).
1. Division of State Architect (DSA)
2. CALFire and Local Fire Offices
3. Public Works Board

E. Consistency with Chapter 1016, Statutes of 2002 – AB 857


1. Does the recommended solution (project) promote infill development by
rehabilitating existing infrastructure and how?

2. Does the project improve the protection of environmental and agricultural resources
by protecting and preserving the state’s most valuable natural resources?

3. Does the project encourage efficient development patterns by ensuring that


infrastructure associated with development, other than infill, support efficient use of
land and is appropriately planned for growth?

Response: Consistent with the provisions of AB 857, Chapter 1016, Statutes of 2002,
the California Community Colleges are exempt from these specific provisions of this
legislation.

16
CALIFORNIA ENVIRONMENTAL QUALITY ACT

ENVIRONMENTAL IMPACT REPORT

An update to the original campus master plan was completed in 2006 and also the
Environmental Impact Report for the Plan has been completed. This update to the Master
Plan included the proposed Emergency Services (OE-2) Replacement project. The State
Clearinghouse Number is 2006011080 and the Notice of Determination was filed on
December 15, 2006.
California Community Colleges
Final Project Proposal

OUTLINE OF SPECIFICATIONS
District: San Bernardino Community College District College: Crafton Hills College

Project: New Emergency Services (OE-2)

DIVISION 1 - GENERAL REQUIREMENTS

01010 - Summary of Work


The Project Scope includes the construction of an approximate 33,000 gross square footage Occupational Education
#2 building for Crafton Hills College located in Yucaipa, CA. Interior spaces include:
1. Public and Protective Services Classrooms, Public and Protective Services Labs, EMT/Res. Care
Classroom and Lab and Support spaces.
2. Vehicular Storage
3. Tutorial/Individualized Study Room
4. Staff Offices
5. Lecture Rooms

01040 - Coordination
Requirements for coordination of Work of the Contract.

01450 - Quality Control


Requirements for quality assurance and control of installation, field samples, manufacturer's field services and
reports, and identification of reference standards.

01405 - Testing and Inspection


Provide testing and inspection services to meet requirements of the California Building Code (CBC), Title 24, Parts
1 and 2 - current edition.

01500 - Temporary Construction Facilities


Contractor to provide temporary construction facilities such as: temporary utilities, Owner's inspector's office,
sanitary facilities for workmen, construction aids, tree & plant protection, access road, parking area, dust control,
erosion & sediment control, security and project identification sign.

01600 – Product Requirements


Requirements regarding products, transportation and handling, storage and protection, options, substitutions and
owner-furnished products.

01700 – Execution Requirements


Requirements and limitations regarding cutting and patching for work, cleaning, project record documents, closeout
procedures, adjusting, operation and maintenance data, warranty and guarantee, spare parts and maintenance
materials, instruction to Owner’s personnel.

01725 - Field Engineering


Contractor is required to make provisions of survey and field engineering services for the project. Establish a
minimum of two permanent bench marks on site, referenced to established control points.

DIVISION 2 - SITE WORK

02230 - Site Clearing


The existing site will be graded to a rough grade condition ready for grading to construct buildings and other
improvements. Locate existing utilities to be connected to, capped or relocated. Protect existing facilities to remain.
Work Includes: Removal of vegetation, grass, grass roots, shrubs, tree stumps, trees, upturned stumps, weed
growth, tree roots, brush, masonry, concrete, rubbish, debris and other objectionable materials, within limits of

1
California Community Colleges
Final Project Proposal

construction. Removal of concrete and bituminous surfaces. Remove materials and debris and dispose of legally
off-site.

02300 - Earthwork
Excavation for building and retaining foundations. Over excavation and re-compaction per soils report
recommendation. Preconstruction removal and stock piling of topsoil. Rough grading and contouring of site in
preparation for building excavation including cutting, filling and compacting. Import of fill material if required.
Excavation for building and retaining foundations. Backfilling required for building and retaining wall perimeters
up to subgrade elevations. Import or export of material if required.

02315 - Trenching
Excavation, backfilling and compaction of trenches for utilities to within 5 feet of building lines.
Requirements for excavation, backfilling and compaction of concrete filled utility trenches in sidewalk areas; as
provided under other sections.

02362 - Termite Control


Furnish five year written warranty certifying that applied soil treatment prevents infestation of subterranean termites
and that if subterranean termite activity is discovered during warranty period, soil will be retreated and damage
caused by termite infestation will be repaired or replaced at no additional cost to Owner.

Termite Control: Emulsified concentrate insecticide for dilution with water specially formulated to prevent
infestation by termites and not injurious to vegetation.

02515 - Unit Pavers


Precast concrete unit pavers with dry mortared joints installed over aggregate bed over compacted soil base.

02520 - Portland Cement Concrete Paving


Install new natural concrete sidewalks, driveways, curbs and gutters. Integral color sidewalks and paving with
scored decorative patterns at indicated areas.

02575 - Pavement Repair


Bituminous Surfacing Repair: Areas removed for utility trenches, heaved by tree roots, cracked areas, protruding
areas where pavement meets hard surfaces, depressed areas, holes and areas around new structures, and raveled
bituminous pavement.
Concrete Pavement Repair: Areas heaved by tree roots, cracked areas, holes and trenches, and areas around new
structures.

02577 - Pavement Striping


Painting parking stalls, divider striping, traffic symbols, accessibility symbols, lettering and curb demarcations on
asphaltic concrete paving and Portland cement concrete curbs and wheel stops. Provide painting of loading and fire
lane areas where indicated.

02620 - Subdrainage
Subsoil Drainage Piping: Polyethylene: Perforated corrugated polyethylene tubing, ASTM F405 and F667,
complete with fittings, couplings, filter fabric wrap, and joint materials. PVC: Polyvinyl chloride pipe, ASTM
D2729 or D3034, with three rows of 3/8 inch diameter holes spaced on 5 inch centers at 60 degrees apart.

Filter Fabric: Non-woven, geotextile fabric of polypropylene or polyester fibers. Water Flow Rate: 230 GPM/SF
minimum.

Subsurface Drainage Mat: Vertical grade drainage mat, polyester or polypropylene geotextile fabric bonded to
compression-resistant three-dimensional, non-biodegradable, single-sided, sheet polymeric core construction
designed to effectively conduct water to foundation drainage system.

02711 - Gas Distribution Systems


Coordination of installation of natural gas piping and appurtenances.

2
California Community Colleges
Final Project Proposal

02713 - Water Distribution System


Water service lines including connection to the existing City of Yucaipa potable water distribution system. Testing
and sterilization.
Fire service lines with reduced pressure backflow, fire department connections, and post indicator valves connected
to the City of Yucaipa Water Department potable water distribution system.

02721 - Storm Drain System


Surface drainage receptors, area drains, catch basins, foundation drainage system and under ground piping to within
5 feet of building lines including connections of building storm drain system to existing campus drainage system.

02722 - Sanitary Sewage Systems


Sanitary sewer piping with fittings, manholes, and accessories to within 5 feet of building lines including
connections to the campus sanitary sewer system.

02780 - Electrical and Communication Utilities


Electrical and communications duct and structures for main runs to transformers and main panels including duct
piping, manholes, pullboxes, transformer pads, stub-outs for buildings and connection to existing CHC system.

02810 - Landscape Irrigation System


Work included: Irrigation Work includes but is not limited to the following:
Replacement of existing irrigation mains, points of connection, valves, control wires, electrical boxes, controllers,
sprinkler heads and caps for future connections.

02840 - Walk, Road, and Parking Appurtenances


Traffic and parking control signage complete with excavation for post bases and concrete post footings. Signage to
be compliant with campus standards.

02870 - Site and Street Furnishings


Concrete benches, trash receptacles, tree grates, and specified site furnishings.

02871 - Bicycle Racks


Metal Bicycle Rack: Undulating steel pipe, set in ground. Quantity and location as indicated on the Drawings.

02900 - Planting
Preparation of sub-grade including placement of topsoil, soil amendments, fertilizers, and final grading.
Planting of trees, palms, plants, ground covers, meadows and lawns with temporary support, mulching and
fertilizing.

DIVISION 3 - CONCRETE

03100 - Concrete Formwork


Formwork for cast-in-place concrete with shoring, bracing and anchorage including form accessories and stripping
forms. Forming materials consist of but are not limited to panel forms, board forms, chamfer strips, wood framing,
form ties and spreaders, expansion joint filler, form sealer, release agent also included.

03200 - Concrete Reinforcement


Reinforcing, supports and accessories for cast-in-place concrete: Bars, welded wire fabric, tie wires, welding
electrodes and bar supports.

03300 - Cast-In-Place Concrete


Cast-in-place concrete for building footings, walls, columns, floor slabs on grade and wearing slabs at stairs and
balconies. Concrete Mixes: Wearing Slabs at Stairs and Balconies: Minimum 3000 psi compressive strength; 115
lbs/cu ft air dry; 4 inch slump. Other Concrete: Minimum 3000 psi compressive strength after 28 days; 145 lbs/cu
ft air dry; 3-1/2 inch slump. Interior Slab: Steel troweled. Exterior Concrete: Smooth finish. Slabs to receive
Setting Bed for Tile or Terrazzo: Scratch finish.

3
California Community Colleges
Final Project Proposal

03350 - Sealed Concrete Finishing


Applied Finishes include floor sealers, water based acrylic sealing compounds, that are compatible with subsequent
coatings and toppings.

03450 - Precast Architectural Concrete


Architectural Precast Concrete: Wind Loading, Engineer typical exterior envelope to withstand 40 PSF positive and
negative wind load acting normal to plane of walls or building code requirements, whichever is greater.
Engineer corner within 10 feet and parapet areas of exterior envelope to withstand plus 40 PSF and minus 60 PSF
wind load acting normal to plane of walls or building code requirements, whichever is greater.
Testing Laboratory Mock-up: Provide architectural precast concrete units as necessary to make full size mock-up at
testing laboratory. Finish: Match Architect's sample.

Structural Requirements: Employ professional structural engineer registered in State of California to engineer each
component of exterior wall system and to prepare and supervise preparation of engineering data for architectural
precast concrete system. Included are drawings, development of testing program, interpretation of test results, and
comprehensive engineering analysis showing compliance with performance and other Specification requirements.

DIVISION 4 - MASONRY

04200 - Masonry Units


Concrete masonry, mortar, grout, reinforcement, anchorage and accessories for 6", 8" and 12" concrete masonry
units.
Mortar: ASTM C270 Proportion Method, portland cement/hydrated lime mix; use Type S, 1800 PSI for load
bearing walls; ASTM C270, Type N, 750 PSI for non-load bearing walls. Use of masonry cement not allowed.
Masonry Grout: 3000 PSI at 28 days, 9-1/2 inch slump.
Horizontal Joint Reinforcing: ASTM A82 hot dip galvanized, truss for single wythe; ladder design for cavity walls.
Concrete Masonry Units: ASTM C90, Type II non-moisture controlled, Grade N, lightweight or normal weight
aggregate at Contractor's option.

DIVISION 5 - METALS

05120 - Structural Steel


Structural steel elements including temporary and permanent bracing in accordance with AISC "Specifications and
Code of Standard Practice."

05300 - Metal Decking


Metal Decking roll-formed sheets conforming to ASTM A 653, with G90 zinc coating. Refer to Drawings for metal
decking requirements. Requirements of Regulatory Agencies be responsible for obtaining DSA and Underwriters
Laboratories Inc. (UL) approval for the decking when used as a part of an assembly indicated on Drawings in which
fire resistive construction ratings are required. Work of the Regulatory Agencies shall be in accordance with CBC
Chapter 22A.

05500 - Metal Fabrications


Shop fabricated miscellaneous non-structural metal items and associated manufactured items.
A. Miscellaneous Items: ASTM A36.
B. Rolled Steel Bars, Plates, and Shapes: ASTM A6/A6M
C. Steel Tubing: Cold-formed, ASTM A500.
D. Structural Steel Sheet: Hot-rolled, ASTM A570/A570M, Class 1; of grade required for design loading.
E. Galvanized Structural Steel Sheet: ASTM A653/A653M, Quality SQ, of Grade required for design
loading.
F. Cold-Rolled Steel Sheet, Commercial Quality: ASTM A366.
G. Steel Pipe: ASTM A53
H. Pipe Bollards: Galvanized steel pipe filled with concrete with formed dome top.
I. Lateral Supports for Storefronts

4
California Community Colleges
Final Project Proposal

J. Toilet Partition Supports


K. Vanities and Countertops: Provide framing to support countertops.
L. Miscellaneous Items: ASTM A36
M. Provide galvanized steel for all steel items exposed to exterior and built into exterior walls.
N. Fasteners: Provide zinc-coated fasteners for exterior use or where built into exterior walls. Select
fasteners for the type, grade and class required.
O. Furnish bent or custom fabricated bolts, plates, anchors, hangers, dowels and miscellaneous steel and
iron shapes required for framing, supporting, anchoring or securing fixtures, accessories, and
furnishings.

05515 - Ladders
Vertical Ladders: Provide at elevator pit and roof access hatches. Structural Requirements: Comply with applicable
provisions of ANSI A14.3 for design, materials, fabrication and installation of component parts, and with
ANSI/ASME A17.1 ladder requirements at elevator pits. Stair treads: capable of withstanding concentrated 1000 lb
load without deformation.

05520 - Handrails and Railings


Handrails and Guardrails: Capable of Withstanding specified loads: Concentrated load of 200 pounds applied at
any point in any direction. Uniform load of 50 PLF applied in any direction. Concentrated and uniform loads above
need not be applied simultaneously. Round Structural Tubing System: ASTM A500, seamless, Grade A. Size: 1-
1/2 inches, outside diameter.

05585 - Column Covers


Metal Column Covers: Aluminum fabricated to shapes indicated.
Finished Work: Straight and true without scratches, scars, creases, buckles, ripples or chatter marks. Do not use
exposed fasteners.

05700 - Ornamental Metalwork


Architecturally exposed structural steel: Provide architecturally exposed metals free from surface blemishes in
finished unit. Exposed-to-view surfaces exhibiting pitting, seam marks, roller marks, stains, discolorations, or other
imperfections on finished units are not acceptable. Provide architectural grade steel where exposed to view.

05720 - Ornamental Metal Railings


Manufactured Ornamental Stainless Steel Handrails and Railings: Capable of withstanding following loads applied:
Concentrated load of 200 pounds applied at any point in any direction, uniform load of 50 PLF applied in any
direction, concentrated and uniform loads above need not be applied simultaneously.

DIVISION 6 - WOOD AND PLASTICS

06100 - Rough Carpentry


Wood framing auxiliary to building structure, miscellaneous blocking and curbing, concealed wood framing,
furring, sheathing, fire and preservative treated.
Lumber: Structural grade I Air or kiln dried prior to arrival on site to maximum 19 percent moisture content, except
for 2 inch lumber which may be maximum 15 percent at time of surfacing. Surfaced four sides, resawn finish at
heavy timber construction.

06200 - Finish Carpentry


Fabrication and installation of exposed, site finished, non-structural wood items, other than casework and paneling,
complete with blocking, grounds, and nailers.
Standards: Woodwork Institute of California (W.I.C.), latest edition for exterior and interior trim, miscellaneous
millwork and laminated plastic covered casework and countertops. Hardwood: WIC Custom Grade Walnut,
Transparent Finish. Cedar Siding: Western Red Cedar, WIC, Section 3, Custom Grade, transparent finish, 1 x 6, T
& G with beveled edges, smooth surfaced. No edge knots. Laminated Plastic Paneling: Wilsonart Wall Panel
System No. 210, standard, with manufacturer’s recommended moldings. Fiberglass Reinforced Panels. (FRP):

5
California Community Colleges
Final Project Proposal

Kemlite Corp. “Glasboard”, Marlite Brand “FPR”, 1/8” thick, with manufacturer’s standard molding in color
matching panels.

06400 - Architectural Woodwork


Architectural woodwork shall include, casework, trim, hardware, countertops and shelving. Comply with
Woodwork Institute of California (W.I.C.) Manual of Millwork guideline as a minimum requirement.
Standards: WIC, latest edition for exterior and interior trim, miscellaneous millwork and laminated plastic covered
casework and countertops.

06650 - Solid Polymer Fabrications


Solid Polymer Sheets: ANSI Z124. Fabricate solid polymer to follow thicknesses; unless indicated otherwise:
Solid Polymer Countertop: 3/4 inch minimum
Solid Polymer Splash: 3/4 inch minimum

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

07130 - Sheet Waterproofing


Sheet Waterproofing: Materials: Rubberized asphaltic sheet laminated to a polypropylene film, 60 mil minimum
total thickness.
Locations:
a. Vertical surfaces of two sided formed foundation walls.
b. Horizontal surfaces of plaza decks with occupied space below.
c. Planters.
d. Sandwich slabs.
e. Elevator pits.
Protection Board: Asphaltic, preformed sheet or board, 1/8 inch thick. Fan-Fold Protection Board (Vertical
Applications): Extruded polystyrene sandwiched between non-perforated film laminates designed for use in
commercial foundation waterproofing applications; 15 PSI compressive strength. Thickness: 1/4 inch.

07141 - Hot Rubberized Asphalt Waterproofing


Hot Rubberized Asphalt Membrane: Rubberized asphalt membrane compound for thick-coat application, fast
setting, self-bonding to substrate, non-shrinking, thermosetting.
Physical Properties: Solids: 100 percent,. Pouring Temperature: 400 degrees F.
Thickness: 225 mils minimum, reinforced. Insulation, Plaza Deck Drainage Mat and Architectural Pavers.

07160 - Cementitious Waterproofing


Crystalline (Cementitious) Waterproofing: Non-shrinking, cementitious mixture producing capillary penetration
into substrate, manufacturer's standard colors. Trowel or dry-shake applied waterproofing, designed for negative
side waterproofing, manufacturer's required thickness.

07190 - Water Repellents


Penetrating Water Repellent Sealer: Water based silane/siloxane based composition; non-staining, breathable
solution. Locations: Architectural Precast Concrete. Penetrating non-film forming type which does not alter
natural surface appearance. Field Sample: 100 SQ FT sample of coating for Architect's review.

07210 - Building Insulation


Maximum use of recycled material with minimum of 20 percent post consumer and 5 percent post industrial
recycled glass cullet. Use formaldehyde free materials where available.

Batt (Blanket) Insulation


Fiberglass Batt Insulation - Unfaced: Glass fiber composition, friction fit type, unfaced. Location: Exterior walls
including return air plenums and underside of roof decks.
Fiberglass Batt Insulation - Vapor Retarder: Glass fiber composition with integral fire retardant foil reinforced kraft
laminate vapor retarder.

6
California Community Colleges
Final Project Proposal

Spandrel Glass Insulation: Inorganic glass or mineral fiber semi-rigid board insulation. Location: Applied to
curtain wall spandrel glass.

Schedule: Provide minimum thermal resistance (R Values) for insulation in locations as follows:
1. Exterior Walls: Thermal resistance R Value of 19.
2. Roof Decks: Thermal resistance R Value of 30.

07260 - Vapor Retarders


Class A Vapor Retarder (10 mil): Virgin waterproof polyolefin film; recycled materials not allowed. Comply with
ASTM E1745, Class A minimum. Tensile Strength: 45 pound/inch minimum, ASTM E154, Section 9. Permeance:
ASTM E96, Procedure A; 0.05 perms maximum. Puncture Resistance: 2200 grams minimum, ASTM D1709,
Method B. Location: Under slabs on grade.
Joint Tape: Manufacturer’s recommended, pressure sensitive type, self adhering, and of perm rating not less than
vapor retarder.
Pipe Boots: Construct pipe boots from vapor barrier material and pressure sensitive tape per manufacturer’s
instructions.

07270 - Spray-on Air Barrier


Fluid Applied Air Barriers: One component, liquid emulsion, breathable fluid applied material. Color:
Manufacturer’s standard. Transition Membrane: Self-adhering membrane consisting of an SBS rubberized asphalt
compound, integrally laminated to polyethylene film. Compatible with spray applied air/vapor barrier. Provide
compatible transition sheet between differing substrates and for terminating at penetrations.

07412 - Preformed Metal Wall Panels


Insulated Core Panels: Interlocking male/female edges, consisting of interior and exterior metal skin laminated to
foam insulating core.
Metal: Prefinished galvanized sheet steel, ASTM A446/A446M, Grade A, with ASTM A653, G90 zinc
coating, 22 gage minimum. Insulation: FS HH-I-530, 95 percent minimum closed cell structure, poured
in place polyisocyanurate foam. Fabricated for joint orientation indicated on Drawings. 24 inch widths,
2 inch overall thickness. Corners: Factory fabricated formed corner panels. Stucco-embossed pattern.
Flashing, Copings, Trim, Closure Pieces, Drips, and Accessories: Same material, thickness, and finish
as adjacent metal panels, brake formed to required profiles.

07525 - PVC Thermoplastic Membrane Roofing


Install an adhered roofing membrane with flashings and other components to comprise a roofing system.
Reinforced Thermoplastic (PVC) Membranes: Flashing Materials: PVC-coated, heat-weldable sheet
metal capable of being formed into a variety of shapes and profiles, Fasteners: corrosion
resistant, miscellaneous accessories, including walk pads as recommended by roofing
manufacturer, and Polyisocyanurate Insulation.
07600 - Flashing and Sheet Metal
Sheet Metal Flashing and Trim: Galvanized Steel Sheet: Zinc coating, hot dip galvanized, flattened sheets,
chemically treated. Finish: Mill phosphatized. Coordinate with PVC coated materials required for roofing
membrane terminations.
Fabrication Items: Flashing, gutters, downspouts, coping, fascia/gravel stop, scuppers, and conductor heads.
Standard: Sheet Metal and Air Conditioning Contractor's National Association, Inc., (SMACNA): Architectural
Sheet Metal Manual.

07700 - Roof Specialties and Accessories


Curbs and Supports: Factory formed roof curb framing with 18 gage minimum galvanized steel construction,
internal steel reinforcing, factory insulated, and pressure treated wood nailers. Minimum height of 8 inches above
finished roof.
Pipe Portals: Manufacturer’s standard ABS and EPDM rubber boots to accommodate 3/8 through 6 inch diameter
pipe.

7
California Community Colleges
Final Project Proposal

Roof Hatch: Single leaf. Provide primed galvanized steel or aluminum body and door, liner insulation for door,
rigid insulation around body and hardware. Ladder Safety Post: Provide telescoping tubular safety post fabricated
from hot-dipped galvanized steel.

07810 - Applied Fireproofing


Sprayed Fireproofing: Factory formulated mixture of asbestos-free cementitious materials with aggregates.
Testing: Perform thickness and density tests on installed fireproofing in accordance with ASTM E605.

07840 - Firestopping
Make firestop and smoke seal assembly selections that comply with UL Fire Resistance Directory, authority having
jurisdiction, and applicable codes for: Materials, fabrication, and installation of firestops and smoke seals. Fire
containment. Fire resistant construction joints. Dynamic partition head details. Edge of slab and curtain wall
conditions. Penetrations through fire-rated floors, walls, and shafts. Duct and damper firestops.

Firestop voids and openings in applicable locations. Select appropriate systems with UL ratings for conditions
encountered, obtain approval from authorities having jurisdiction, and place identification label at each location
indication materials, rating, and UL assembly number.

07920 - Joint Sealants


Warranty: Five year warranty covering installed sealants and accessories which fail to achieve air tight and
watertight seal, exhibit loss of adhesion, exhibit loss of cohesion, and do not cure.
A. Acrylic Latex: ASTM C834; non-sag; non-staining; non-bleeding.
B. Silicone—General Purpose: ASTM C920; Type S; Grade NS; Class 25; Uses NT, G, A, O.
C. Silicone—Sanitary: ASTM C920; Type S; Grade NS; Class 25; Uses NT, M, G, A, O.
D. Urethane—Traffic-Bearing (Designation U-TB): ASTM C920; Type M; Grade P or NS; Class 12-1/2;
Uses T, M, O.
E. Provide necessary sealant backing bond breaker rods and tape, and elastomeric tubing joint fillers.

DIVISION 8 - DOORS AND WINDOWS

08110 - Steel Doors and Frames


Custom fabricated hollow steel doors, door frames and glazed light frames with accessories and anchors complying
with HMMA 861 "Guide Specifications for Commercial Hollow Metal Doors and Frames."

Doors: Flush Doors: HMMA Type A; flush with continuous welded edge seams; full flush and flush with vision
panels. Stile and Rail: HMMA Type D; tubular stiles and rails with no edge seams; full glazed configuration.

Door Construction: Exterior: Minimum 16 gauge cold rolled steel conforming to ASTM A366 with hot-dipped zinc
coating per ASTM A526 G60. Interior: Minimum 18 gauge cold rolled steel conforming to ASTM A366.

Frames: Exterior: Minimum 14 gauge cold rolled steel conforming to ASTM A366 with hot-dipped zinc coating
per ASTM A526 G60; corners continuously welded full depth of frame. Interior: Cold rolled steel cold rolled steel
conforming to ASTM A366; corners continuously welded full depth of frame. Openings to 4 Feet Wide: Minimum
16 gauge. Openings Over 4 Feet Wide: Minimum 14 gauge.

08210 - Wood Doors


Factory finished solid core interior flush wood doors meeting WIC requirements for paint grade. Fire rating label as
required. Doors: Thickness: 1-3/4 inch. Finish: WI System Number 4 – Conversion Varnish.

08310 - Access Doors


Doors for access to utilities in walls and ceilings. Fire rating label as required.
Access Doors in Gypsum Plaster and Cement Plaster Ceilings:
Non-Rated Ceilings in Utility Spaces: Flush steel door; one piece frame with exposed flange; screw driver
operated steel cam lock; prime painted finish.
Non-Rated Ceilings in Occupied Spaces: Recessed steel door to receive drywall panel; integral drywall bead
at frame; flush screwdriver operated cam lock; prime painted finish.

8
California Community Colleges
Final Project Proposal

Rated Ceilings: Flush insulated steel door; self-closing and self-latching; bolt type latch operated by ring turn
or direct action knurled knob; interior latch release; one piece frame with exposed flange; 3-hour WHI
label; prime painted finish.
Access Doors in Gypsum Board Partitions:
Non-Rated Partitions in Utility Spaces: Flush steel door; one piece frame with exposed flange; key
operated steel cam lock; prime painted finish.
Sound Transmission Classification (STC): Provide sound retardant doors capable of achieving STC rating selected,
when tested in accordance with ASTM E90-75. Units are to be complete with doors, frames, seals, anchors and
hardware. Supply composite felt/elastomer sound seals, adjustable seal retainer, cover plates, threaded fastener and
appropriate door bottom sound seal.

08520 - Steel Windows


Steel windows with fixed and operable awning sash complete with screens, glass and glazing, operating hardware;
anchorage and attachments, paper flashing and perimeter sealant.

Awning Windows: Steel; single web and tubular construction; 1-1/8 inch deep perimeter frame; 1 inch deep vent
frame; integral nail-on fin; square profile extruded steel glazing beads for 5/8 inch glass; Projected and
Casement Windows.

Glass and Glazing Materials:


Glass: Clear and tinted insulated acoustic clear float glass units; 5/8 inch overall.

08710 – Finish Hardware


Template hardware throughout.
Fastenings as required or recommended by manufacturer, furnished with all hardware.
Finish: US 10B.
Finish hardware material per Hardware Schedule.
Door Hinges: All doors with door closers to have ball bearing hinges. Outswing exterior doors to have non-
removable pins.
Exterior: Match campus standard.
Interior: Match campus standard.
Stops and Holders: Match campus standard, generally floor type with three connections to the floor.
Seals and Weatherstrip: Aluminum extrusions with neoprene seals.
Thresholds: Maximum ½” height, and in compliance with the most restrictive accessibility requirements.

08712 - Door Hardware


Operating Door Hardware and trim, gasketing and thresholds complying with state accessibility codes and
applicable fire codes.
Locksets:
Doors: Schlage L Series Heavy Duty Mortise Locks.
Exit Devices: Von Duprin Exit Devices.
Keying: Grand master, master keyed to SBCCD standards alike and keyed different.

08800 - Glazing
Glass and glazing for wood doors, steel doors, wood windows, and steel glazed light frames. Requirements for glass
specified in other sections.
Flat Glass:
Clear Float Glass: ASTM C1036, Type I, Class 1, Quality q3; clear; 1/8 and 1/4 inch thicknesses.
Clear Tempered Glass: ASTM C1048, Kind FT, Condition A, Type I, Class 1,
Quality q3; fully tempered clear; 1/4 inch thick.
Heat Absorbing Tinted Glass: ASTM C1048,Type 1, Class 3, Quality Q3, Float
Type, tempered, light reducing in gray color; light transmittance of 42 percent, shading
coefficient of .51; ¼ inch thick.
Security Glazing; Laminated glass with poly carbon core & clear glass on outer faces.
Spandrel Glass: Float, ASTM C1036, Type 1, Class 1, Quality q5. Coating ceramic frit on No. 2 surface.

9
California Community Colleges
Final Project Proposal

08830 - Mirrors
Unframed Mirror Glass: ASTM C1036, Type I transparent flat, Class 1 clear, Quality q2 mirror. Type: Annealed.
Thickness: 1/4 inch
Edges: Square and polished
Reflective Coating: Manufacturer's standard silver coating followed by electrolytic deposited copper coating and
separate coat of protective paint. Fasten with mirror adhesive.

08920 - Glazed Aluminum Curtain Walls


Structural Requirements: Provide system engineered by registered professional engineer licensed to practice
structural engineering in jurisdiction where Project is located. Design anchors, fasteners and braces to be
structurally stressed not more than 50 percent of allowable stress when maximum loads are applied. Solar Shades:
Custom design for attachment to curtain wall.

Design Requirements: Metal stick framed systems with interior and exterior exposed metal framing. Fabricate
glazing systems for exterior glazing. Solar shades: Design solar shades as integral part of curtain wall system.

Framing Materials and Accessories: Aluminum: ASTM B221, alloy 6063-T5 for extrusions; ASTM B209, alloy
5005-H16 for sheets; or other alloys and temper recommended by manufacturer appropriate for specified finish.
Thermal Break: Manufacturer's standard non-metallic urethane insulating core, isolator spacers, or clip system to
provide thermal separation between exterior and interior components. Internal Reinforcing: ASTM A36/A36M for
carbon steel; or ASTM B308/B308M for structural aluminum. Inserts and Anchorage Devices: Manufacturer’s
standard formed or fabricated assemblies, steel or aluminum, of shapes, plates, bars or tubes. Glazing Gaskets:
Compression type design, replaceable, molded or extruded neoprene, polyvinyl chloride (PVC), or ethylene
propylene diene monomer (EPDM), ASTM C509 or C864 to maintain uniform pressure for watertight seal; black
color; factory molded corners required at exterior.

Solar Shades: Fabricate assemblies of extruded aluminum except where specifically noted otherwise. Provide steel
outriggers finished to match curtain wall. Isolate aluminum from steel surfaces to prevent electrolytic action. Field
bolt connections between frame members where necessary by solar shade size. Dress exposed welds smooth and
flush with adjacent surfaces. Fabricate fascia/nosing to match profiles indicated. Finish solar shade to match curtain
wall.

DIVISION 9 - FINISHES

09110 – Non-Load Bearing Metal Studs


Formed metal stud framing at interior partitions and non-bearing exterior walls. Studs: ASTM A446, Grade A,
minimum yield 33 ksi, hot-dip galvanized or ASTM A591 minimum yield 33 ksi electro galvanized sheet steel, DW
Type, punched web, 20 gage minimum thickness, sizes as required to conform to details and scheduled wall
thickness.

09200 – Lath and Plaster


Supply and install lath and Portland cement plaster exterior and interior as indicated.

09210 - Gypsum Plaster


Gypsum plaster wall and ceiling finishes complete with acoustic insulation, acoustic sealant, metal lath and trim
accessories. Comply with ML/SFA “Guide Specifications for metal lath and furring.
Base Coat Materials: Gypsum neat plaster, ASTM C 28, sand aggregate, ASTM C 35, 5/8 inch thicknesses.
Finish Coat Plaster Materials: ASTM C28, Finishing Hydrated Lime ASTM C 206, Type N or S, sand aggregate
ASTM C 35, 3/8 inch thickness.

09220 – Portland Cement Plaster


Portland Cement plaster for exterior wall, ceiling, and soffit locations. Provide complete lath and trim accessories.
Plaster materials: Portland cement, ASTM C 150, Type I or III, Lime, ASTM C 206, Type S, aggregate,
manufactured or natural colored sand and mica flakes, ASTM C 897, potable water, color, texture, and appearance
to match a referee sample provided by the Architect. Fill voids in existing plaster over 3/8 inch deep with a plaster
coat prior to applying finish coat.

10
California Community Colleges
Final Project Proposal

09250 – Gypsum Wallboard


Metal Accessories: Manufacture’s standard galvanized steel trim accessories.
Joint Treatment: ASTM C-474 and C-475.
Finish: Provide textured finish on all gypsum wallboard surfaces except omit texture finish where gypsum
wallboard is concealed in structure or by other finish material (except paint). Omit texture finish in mechanical,
electrical, storage and custodial rooms.

09260 - Gypsum Board Systems


Gypsum board wall and ceiling finishes complete with acoustic insulation, acoustic sealant, resilient channels and
joint treatment.
Standard Gypsum Board: 5/8 inch thickness.
Fire Rated Gypsum Board: ASTM C36; UL rated with Type X - fire resistant core; 5/8 inch
thickness.
Gypsum Backer Board: ASTM C442; standard and UL rated with Type X core; 1/2 and 5/8 inch thickness.
Gypsum Board to Resilient Channels: Type "S" bugle head; length to prevent penetration into framing.

09300 - Tile Work


Quarry and ceramic tile with related sound isolation sheets, mortar beds, membranes, expansion joints, grout and
grout sealer. Materials and manufacturers per campus standards.
Waterproofing Membrane: Heavy duty non-plasticized chlorinated polyethylene synthetic elastomeric sheet
membrane; 40 mil thickness
Ceramic Wall Tile in Showers: Install glazed ceramic wall tile over reinforced mortar bed over membrane in
accordance with TCA B414.
Ceramic Wall Tile in Other Locations: Install glazed ceramic wall tile over reinforced mortar bed over membrane
over solid backing in accordance with TCA W222.

09500 - Acoustical Cement Fiber Panel


The cement fiber acoustic unit material shall be uniformly thick, per the drawing, with tolerance not to exceed plus or
minus 1/8 inch. Planks shall be sufficient length for a two span condition, except end filler, to accommodate stagger
joint installation. Spans over 7 inches shall be single span condition.

09510 – Acoustical Tile ceiling


Acoustical panel sizes as indicated in the Drawings.
Thickness 1.125 inch minimum
NRC Range 0.85
Suspension System, ASTM C635, intermediate duty, interlocking components to resist seismic
lateral pullout. Accessories include hangers, edge moldings and supports for light fixtures and
mechanical outlets. Provide reveal edge trim where ceiling meets vertical surfaces.
09541 - Fiber Reinforced Plastic Paneling
Adhesive/mechanically fastened fiber reinforced plastic paneling with matching molding and accessories.
Panels: Fiberglass reinforced plastic; hard non-porous surface resistant to stains, odor, mildew and mold; meeting
USDA and FDA requirements for use in food processing areas; embossed pebble texture one face; 0.090 inches
thick.

09545 – Special Ceiling Surfaces


Prefabricated Acoustical Ceiling Cloud System: Core: 6 to 7 PCF density semi-rigid glass fiber. Thickness: 1-1/8
inch. Colors: Colors as selected. NRC: 0.85. Light Reflectance: 90 percent. Fire classification: Class A, ASTM
E84. Edges: Fabric wrapped; concealed aluminum frame rigidly attached to core. Installed Panel Deflection: 0.27
percent maximum.

09650 - Resilient Flooring


Vinyl Composition Tile by Armstrong or equal. ASTM F 1066 Class 2, ASTM E662 Smoke Developed 450 or less,
Static Load Limit: ASTM F 970 125PSI, minimum 12 inches x 12 inches x 1/8 inches thick (nominal)

11
California Community Colleges
Final Project Proposal

Resilient sheet flooring with integral cove base and resilient base for glue down carpeting with accessories.
Linoleum Sheet: ASTM F2034, Type 1. Homogeneous sheet linoleum of primarily natural materials consiting of
linseed oil, wood flour, and rosin binders, mixed and calendered onto natural jute backing. Thickness: 0.120 inch,
minimum overall. Heat Welding Rod: Color-matched welding rod.

Resilient Base: ASTM F1861, Type TP. Straight, toe-less type for carpet areas; set-on type with standard toe for
other areas. Thickness: 0.125 inch minimum, height as indicated in the Drawings. Corners field fabricated.

09680 - Carpeting
Yarn: Minimum 3 ply 100% continuous filament nylon with static control.
Meet Federal flammability Standard BOCFF1-70 and ASTM D 2859-70T.
Direct Glue-down with integral cushion and related accessories.

09820 - Acoustical Insulation and Sealants


Thermafiber Sound Insulation Blankets by US Gypsum or equal.

09832 - Elastomeric Deck Coating


Elastomeric urethane waterproof deck coating: Liquid materials used in traffic-bearing deck coating shall be non-
combustible and shall not emit solvents, or other recognized pollutants, into the atmosphere. Elastomeric deck
coating shall not be applied during freezing or inclement weather. Do not apply elastomeric deck coating over
surfaces that contain more than 7 percent moisture content.

Provide primer, flashings, sealants, etc. as required to provide a complete system as shown on the drawings and per
manufacturer's recommendations.

09840 - Acoustical Wall Treatment


Fabric Covered Acoustical Wall Panels: 7 PCF minimum density fiberglass with 1/8 inch thick high density
fiberglass laminated to core for impact resistance.
Assembly Flame Spread and Smoke Generation: Class A, ASTM E84.

09900 - Painting
Surface preparation and application of 3 coat finish system to exposed interior and exterior surfaces.

Exterior Surfaces:
• Uncoated Ferrous Metals: Semi-gloss acrylic enamel; one coat alkyd metal primer; two coats semi-gloss
exterior latex house paint.
• Shop Primed Ferrous Metals: Semi-gloss acrylic enamel; touch-up of shop primer with alkyd metal primer;
one coat alkyd metal primer; two coats semi-gloss exterior latex house paint.
• Galvanized Metals: Semi-gloss acrylic enamel; acid etch and rinse surfaces; one coat alkyd metal primer;
two coats semi-gloss exterior latex house paint.
• Hardwood and Plank siding: Semi-gloss acrylic enamel; two coats alkyd wood primer; two coats
interior/exterior latex semi-gloss enamel.

Interior Surfaces Gypsum Board:


• Semi-gloss Acrylic Latex Stipple Finish: One coat gypsum board pretreatment; one coat stipple; one coat
interior latex semi-gloss enamel.
• Satin Two-Component Epoxy Finish: One coat gypsum board pretreatment; 2 coats interior waterbourne
satin mixture epoxy.
• Uncoated Ferrous Metals: Semi-gloss acrylic enamel; one coat alkyd metal primer; two coats interior
acrylic latex semi-gloss enamel.
• Shop Primed Ferrous Metals: Semi-gloss acrylic enamel; touch-up of shop primer; one coat alkyd metal
primer; two coats interior acrylic latex semi-gloss enamel.
• Galvanized Metals: Semi-gloss acrylic enamel; acid etch and rinse surfaces; one coat alkyd metal primer;
two coats interior acrylic latex semi-gloss enamel.
• Prefinished Metals: Semi-gloss acrylic enamel; acid etch and rinse surfaces; one coat alkyd metal primer;
one coat interior alkyd enamel undercoat; two coats interior acrylic latex semi-gloss enamel.

12
California Community Colleges
Final Project Proposal

• Wood: Semi-gloss acrylic enamel; one coat interior alkyd enamel undercoat; two coats interior/exterior
latex semi-gloss enamel.

09962 – Fabric Covered Tack Panels


Vinyl coated fabric complying with Federal Specification CCC-W-408A, Type II, maximum 24 oz per lineal yard,
color and pattern as selected by Architect from manufacturer’s standard list, flame spread less than 25, smoke
density less than 450, ASTM E84, NFPA 255. Substraight filler as recommended by adhesive and wall covering
manufacturer as compatible.

DIVISION 10 - SPECIALTIES

10100 - Visual Display Boards


Porcelain Steel Markerboard: Porcelain finish on 24 gage enameling sheet steel. ¼ inch thick hardboard of 3/8 inch
particleboard. Backing sheet 0.015 inch aluminum foil.
Linoleum Resilient Homogeneous Tackable Surface Material: Natural materials consisting of linseed oil, granulated
cork, rosin binders and dry pigments, mixed and calendered onto a natural burlap backing. Uni-color shall extend
throughout thickness of material. Contains no harmful by-products or carcinogens. Thickness ¼ inch.

10155 –Toilet Compartments


Material: HDPE or solid phenolic partitions and screens as indicated in the Drawings.
Hardware: Institutional type, satin finish stainless steel. Chrome plate zamac not acceptable.
Compartments: Ceiling hung design complete with attachments and hardware.
Urinal Screens: Wall hung-flange supported complete with attachments and hardware.

10210 - Metal Wall Louvers


Stationary blade steel wall louvers with insect screens. Louvers: Fabricated from minimum 18 gauge galvanized
sheet steel; fixed blades; channel shaped frame with welded corners; shop primed finish.

10400 - Identifying Devices


Code mandated accessibility signage, stair signage and room occupancy signage complying with CBC requirements
and campus standards.
Project building, permanent room identification signage and building directories complying with CBC and ADA
requirements.

10522 - Fire Extinguishers, Cabinets and Accessories


Fire extinguishers, cabinets and brackets with mounting hardware.
Cabinets: Fire rated; double wall 18 gauge cold rolled steel box lined with 5/8 inch thick fire barrier material;
certified and listed by Warnock-Hersey for one and two hour combustible and non-combustible wall systems
to meet requirements of UBC Standard No. 43-6; semi-recessed with 4 inch deep rolled edge return trim;
tubular steel door with full clear acrylic; flush pull handle with self-adjusting roller latch; continuous piano
hinge; maximum 4 inch overall projection from wall.

10675 – Metal Storage Shelving


Steel “Clip” type shelving manufactured by Republic steel or equal.

10800 - Toilet Accessories


Toilet and custodial accessories for common areas and bath accessories for living units complete with rough-in
frames and attachment hardware. Bobrick or equal.
Manufacturer: Bobrick, American Specialties, Bradley, McKinney/Parker or approved equal.

Recommended Schedule of Toilet Accessories is based on Bobrick Model #s:


Paper Towel Dispenser Semi-recessed No. B-3994
Sanitary Napkin Vendor 25-cent coin operated, recessed No. B-3500
Sanitary Napkin Disposal Recessed No. B-353
Sanitary Napkin Disposal Partition Mounted No. B-354

13
California Community Colleges
Final Project Proposal

Seat Cover Dispenser Recessed No. B-3013


Toilet Tissue Dispenser Recessed, Multi-roll No. B-3888
Toilet Tissue Dispenser Partition Mounted, Multi-roll No. B386 (serves 2 compartments)
Soap Dispenser No. B822
Stainless Steel Framed Mirror & Shelf No. B-292
Grab Bar No. B-5806 series
Utility Shelf with Mop and Broom Holder – 36” long with (4) mop holders No. B-224
Warm Air Hand Dryer Recessed No. B-750

DIVISION 11 - EQUIPMENT

11132 – Projection Screens


Electrically Operated Screen: Recessed in ceiling with mounted automatic ceiling closure.
Screen: Matte white, flame and mildew resistant.
Size: As indicated on drawings.

DIVISION 12 – FURNISHINGS

12300 – Manufactured Casework


Laminated plastic-faced casework complying with Woodwork Institute of California (WIC) Manual of Millwork,
Section 15:
Open Cabinets and Cabinets with Glass Doors: Premium Grade
All other Casework: Custom Grade
Casework Design: Flush Overlay
Construction Style:
Style A, frameless
Construction Type: Type I, multiple self-supporting units fastened
together to form a larger unit
Countertops:
Standard Laminate Plastic: WIC Section 16, Custom Grade
Acid Resistant Laminated Plastic: WIC Section 17
Epoxy Resin: WIC Section 17C
• Hardware: Satin stainless steel finish. Keying: Grandmaster key system.
• Mechanical Service Fixtures: Provide for air, gas, vacuum, cold water, and hot water
• Casework Accessories: drawer number plates, apparatus rods, metal tube legs.
• Accessory Cabinets: flammable liquids storage cabinet, vented; corrosive liquids storage cabinet.

12481 - Floor Mats and Frames


Frames: Fabricate manufacturer's standard frame profiles to fit size and style of grille for permanent installation in
shallow, level bottom recess in subfloor without drain pan.
Stainless Steel Grates: Fabricate tread rails from stainless steel wire; minimum .071 by 0.156 inch triangular profile.
Provide 4 hidden lock-down devices near corners of each grille section.

12493 - Rolling Shades


Motor operated rolling shades. Shade Materials: Decorative fabric or black-out fabric as selected by Architect.

.
DIVISION 13 – SPECIAL CONSTRUCTION

13700 - Security System


The Work includes the supply and installation of all components, specified or not, for a complete and working
security systems. This includes, but is not limited to, the supply and installation of:
1. Access Control and Alarm Monitoring System (ACAMS)
2. CCTV Cameras, housing and lenses
3. Intercom System

14
California Community Colleges
Final Project Proposal

DIVISION 14 - CONVEYING DEVICES

No specifications for this section.

DIVISION 15 - MECHANICAL

15011 – General Requirements for Equipment


Principal Items to be Included:
• Air handling units with chilled & heating hot water coils, exhaust fans for laboratory, exhaust fans for
restrooms, supply air valves or VAV boxes with hot water reheat coils and exhaust air valves or VAV
exhaust boxes.

General System Description:


• The air handlers serving the building shall be variable air volume (VAV) with single-supply air duct system
and VAV terminal boxes with hot water reheat coils for each zone.
• The exhaust system serving the building shall incorporate multiple fans in a centralized exhaust system on
the roof and serve all the exhaust needs of the laboratory areas. The exhaust fans shall be sized to provide
the required number of air changes per hour for the laboratories being served.
• Separate exhaust fans shall be specified for restrooms.
• Chilled and heating hot water shall be supplied to the building from the Central Plant.
• The telecommunications building distribution frame shall be provided with a dedicated DX cooling only
split system to provide air conditioning 24/7.

15060 – Piping
Piping Material:
• Chilled water and heating hot water piping: 3” and larger, Schedule 40 black steel pipe ASTM A53, type
ERW, grade B with thermal insulation to minimize heat gain or loss and prevent condensation.
• Chilled water and heating hot water piping: 2 ½” and smaller Type “L”, hard drawn copper tube.
Insulation shall be the same as the larger piping systems.
• Chilled water piping (below grade): pre-insulated PVC pipe (AWWA C900) with high density
polyethylene (HDPE) jacket and restrained joints. Insulation shall be factory applied 2” thick void free
polyurethane foam.
• Heating hot water piping (below grade): pre-insulated type K copper iron pipe with high density
polyethylene (HDPE) jacket and brazed/soldered joints. Insulation shall be factory applied 2” thick void
free polyurethane foam. Expansion control shall be provided by expansion control loops..
• HVAC Condensate Drain: Type “L” copper, insulated. Seamless copper tube. ASTM B88-96.

15140 – Domestic Water Piping Materials


Type L with wrought copper fittings and brazed or soldered joints. Seamless water copper tube: ASTM B88-96

15150 – Sanitary Waste and Vent Piping Materials


Heavy duty cast iron hubless pipe and fittings. ASTM A888 or CISPI 301 with hubless coupling gaskets: ASTM C-
564
15201 – Natural Gas Piping Materials
Schedule 40 black steel with malleable iron fittings.

15250/15290 – Mechanical Insulation


Insulation Material:
ƒ Ductwork: All concealed supply air ducts shall be insulated with 1.5” thick foil-faced fiberglass insulation.
All exposed supply air ducts in duct shaft shall be lined with 1” thick 1.5 pound density fiberglass lining.
All main supply air and return air duct shall be lined with fiberglass lining as indicated on the drawings
from each air handling unit.
ƒ Piping: Chilled water and hot water piping shall be insulated with 1.5” thick, heavy density fiberglass with

15
California Community Colleges
Final Project Proposal

vapor barrier jacket. Insulation for all outdoor piping shall be covered with aluminum jacket.
15245 – Seismic Isolators

Vibration Isolators: Midland-Ross Superstrut or Pipe Shields, installed to prevent transmission of vibration to
structure, including seismic restraints

15310 – Fire Protection System


Riser and cross mains shall be ASTM A 795 Steel Piping schedule 40 black steel pipe. All other sprinkler piping
shall be ASTM A 795 schedule 40 black steel pipe, or ASTM B 88 Type K copper tube Connections or fittings shall
be threaded, flanged, grooved or welded.

15440 – Plumbing Fixtures


Water Closets: Wall hung, vitreous china as manufactured by American Standard, Kohler or equal: “Afwall” Model
No. 3355.160.

Urinals: Wall hung, vitreous china as manufactured by American Standard, Kohler or equal: similar to “Falcon”
No. F-5000.

Sinks: Counter mounted 18 gauge stainless steel as manufactured by Elkay, Just or equal.

Lavatories: Wall hung, vitreous china as manufactured by American Standard, Kohler or equal: “Wheelchair Users
Lavatory” No. 9141.011.

Service Sinks: Corner type precast terrazzo one piece by American Standard, Kohler or equal: Kohler Model No.
K-6710.

Drinking Fountains: Wall mounted, projecting type made of stainless steel manufactured by Haws or equal, model
1011HPS “Hi-Lo”.

15441 – Domestic Water Pump


Close Coupled, In-Line, Seal less Centrifugal Pumps: Factory-assembled and -tested, single-stage, close-coupled,
in-line, seal less centrifugal pumps.

15450 – Domestic Water Heater


Low Nox Commercial Gas Tank Type Water Heaters: ANSI Z21.10.3, ASHRAE/IES
Glass lined tank equipped with integrated control system.

15500 - Heating, Ventilating, and Air Conditioning


Heating, ventilating and air conditioning equipment with related controls, piping and ductwork complying with
SBCCD Design Guideline and Requirements (not yet provided).

Definitions:
HVAC: Heating, ventilating and air-conditioning.
EMS: Energy Management System.

Since the heating and air conditioning system is critically related to the function, industrial hygiene, capital cost,
operating cost and maintenance cost, it is important that the type of system be determined at the preliminary
planning stage. The selection of the type of heating and air conditioning system will require discussion between the
Architect, their Mechanical Engineer, the Facilities Engineer and Facilities Maintenance Director.

Energy Management Control System:


• Existing start/stop contacts are available for some pieces of existing equipment. Contacts will be reused to
the extent possible. Expansion of the system is not anticipated.
• Design all equipment to allow for future connection to an energy management control system.

16
California Community Colleges
Final Project Proposal

Sound Levels:
• Design of air handling and other mechanical systems shall be such that sound levels in all occupied spaces
fall within the NC levels tabulated in the ASHRAE Guide for the occupancies involved.

General Design Considerations:


• All duct and piping systems will be insulated according to Title 24 Energy Compliance requirements.
• Duct lining will be allowed in exposed gymnasium ductwork, but lining will not be allowed in other
locations.

Vibration Isolation:
• All rotating or reciprocating equipment (e.g. fan, motors, compressors, etc.) shall be furnished with
vibration isolation as dictated by program requirements.
• All vibration isolation devices shall be designed for seismic resistance in accordance with SMACNA
Guidelines for Seismic Restraint of Mechanical Systems.
• Ductwork, piping, electrical conduit, etc. shall be suspended with vibration isolating hangers if required to
control vibration in adjacent spaces as determined by program requirements.

15521 – Laboratory Compressed Air Equipments
Packaged Air Compressors and Receivers: Factory-assembled, wired, piped and –tested; electric motor driven; air
cooled; continuous duty; automatic control station; steel receiver tank; combination inlet filter silencer; refrigerant
type air dryer; air cooled, fixed bundle, tubular separators; ASME labeled safety valve; automatic drain valve;
bronze body pressure regulators; coalescing type compressed air filters.

15855 – Air Handling Units


Equipment and Materials:
Air Handling Units: Energy Labs or Alliance Air Products shall be located on the roof. They shall have a draw thru
configuration. Units are composed of filters section, cooling coils, supply fans, return fans, economizer sections,
sound traps and variable frequency drives. Units are variable air volume, providing minimum 3” external static
pressure and operating on 460V – 3ph – 60Hz
AHU-1: 9500 CFM, 430 MBH cooling, MERV 13 filters, 100% OSA economizer, VFD
AHU-2: 9500 CFM, 430 MBH cooling, MERV 13 filters, 100% OSA economizer, VFD
AHU-3: 5000 CFM, 250 MBH cooling, MERV 8 filters, 100% OSA, VFD

15870 – Power Ventilators


The restrooms shall have common, single rooftop exhaust fan. The fans shall have the following characteristics and
approximate capacity: 5300 CFM, .75 in.w.c. TSP, spun aluminum housing, down blast roof ventilator, direct drive
fan with speed controller, factory curb and backdraft dampers. Exhaust fans for restrooms: Greenheck or Cook, roof
exhauster, belt-driven with centrifugal backward inclined wheel.

15890 – Ductwork
Supply Air Ductwork: Supply air duct system shall be galvanized steel of minimum 4-inch water gauge pressure
class for mains. Branch ducts shall be minimum 2-inch class. Sealing, reinforcing and supporting shall be
according to SMACNA standards. Ductwork shall have thermal insulation to minimize heat gain, and prevent
condensation.

General Exhaust Ductwork: General exhaust duct system shall be galvanized steel of minimum 2-inch water gauge
pressure class. There shall be no insulation provided for exhaust ductwork.

15856 – AC Split Systems


BDF Split System: The ductless wall mounted split system serving the BDF shall be Carrier or Trane. It is a 2 1/2
Ton unit and the fan coil shall be mounted within the wall space of the BDF and the condensing unit shall be
located on the roof. A low ambient control system shall be provided on the condensing unit to accommodate low
ambient conditions.

17
California Community Colleges
Final Project Proposal

15910 – Ductwork Accessories


Sound Traps: Vibro-Acoustics or IAC, at suction and discharge of each exhaust fan.

15930 – Air Terminal Devices


Variable Air Volume Boxes: The size and number of VAV terminal boxes to serve each area is based on the load,
ventilation requirement, and functionality. All supply VAV boxes are furnished with a two-row reheat coil. All
VAV boxes shall be pressure independent with closed-loop feedback controller.

15936 – Air Inlets and Outlets


Diffusers and Exhaust air grilles: Anemostat, Krueger, Titus or Tuttle & Bailey, flush with ceiling and furnished in
Factory-finished enamel of color to match ceiling tiles. Provide low-velocity hemispherical pattern diffusers in
laboratories housing fume hoods. Such diffusers are designed to handle a large volume of air in confined spaces
with low room velocity. Conventional ceiling diffusers of square face panel type shall be provided in laboratories
free of fume hoods, offices, classrooms and other non-laboratory areas. The exhaust grilles shall be steel or
aluminum, perforated face panel with back pan and duct connection collar.

15950 – Testing, Adjusting and Balancing


All systems to be fully tested, adjusted and balanced.
Contractor shall be AABC certified. NEBB will not be accepted.

15975 – Direct Digital Control System


Direct Digital Controls: The building automation/energy management system shall be compatible with the existing
energy management system resident. The building controllers shall integrate with central utilities and the laboratory
control systems. The system shall be able to integrate multiple building functions, including equipment supervision
and control, alarm management, energy management, historical data management and archiving, and monitoring of
laboratory controls.

All control panels shall be stand-alone in memory, networking, and control operations. The design of the controls
shall be in a modular format, permitting future expansion capabilities. The system shall monitor and control
equipment according to the sequence of operation, as well as additional input and output points. The building
control system shall operate to ensure operation safety, regulatory compliance and to satisfy process constraints as
well as occupant comfort.

Conventional VAV boxes with direct digital control shall be provided in laboratories free of fume hoods, offices,
classrooms, and other non-laboratory areas.

DIVISION 16 - ELECTRICAL

16010 – General Requirements


Concrete housekeeping pads are required for all floor-mounted electrical equipment, both interior and exterior. All
equipment enclosures are required to have adequate working space without including areas impacted by door
swings.

All electrical equipment doors are required to have concealed hinges and flush locks. All doors must swing in the
direction of egress.

16050 – Basic Materials


All wiring devices (receptacles, GFIC devices and wall switches) shall be gray in color with satin stainless steel wall
plates.

Receptacles and Switches: 20A Heavy duty. Manufacturers: Cooper, Hubbell, Leviton and P&S.

All surface mounted boxes are required to be plumb and square in all three dimensions – floor, walls and ceilings.
Skewed boxes are unacceptable. Floor boxes are preferred to be Walker RFB4 Series with power fittings and
accessories. Cover is preferred to be Walker S36CCTCAL cover “Floor Port” Flanged Activation Kits with insert
areas to allow carpet and tile cutouts to match the finished floor.

18
California Community Colleges
Final Project Proposal

Above ground: Rigid conduit, IMC or EMT are acceptable. Rigid conduit is required in all outdoor locations, and
where conduit is exposed to physical damage.

All EMT conduit fittings shall be compression type. Screw type fittings are not allowed.

All power and fire alarm cables shall run in conduits. MC cables except for lighting whips (limited to 4 feet only)
are not allowed.

All electrical equipment including receptacles and switches shall be labeled.

16122 – Medium Voltage Cable


5 kV feeders shall have 133 percent insulation, MV105 type, single-conductor; solid-dielectric Ethylene Propylene
Rubber (EPR) insulated, shielded and jacketed rated for 105C for continuous service Manufacturers: Kerite,
Okonite, Pirelli or Rome.

16321 – Pad Mounted Transformer


R-temp/ FM listed transformer with copper winding is preferred. Manufacturers: Square-D, G.E., Cutler Hammer
and ABB transformers.

16363 – Selector Switch- 15 KV


Pad mounted 15 KV, SF6, (4) ways gas selector switch. Manufacturers: S&C, G&W Electric Company and Canada
Power Products Corporation

16460 – Dry Type Transformer -600V or less


Transformers are required to have copper winding and 150°C class insulation. Manufacturers: Carol, Okonite,
Rome, Southwire, Triangle or Pirelli.

16470 – Panels Boards


All panels shall have copper busses, bolt on type and equipped with main breakers. Manufacturers: General Electric,
Square-D., Cuttler Hammer.

16471 – Distribution Boards


Switchboards and distribution boards shall have copper busses and are required to be dead front with all
terminations front accessible. Manufacturers: Cuttler Hammer, General Electric, Square-D.

16510 – Lighting
Exit signs with LED type lamps are required.
Light fixtures: As shown on drawings or as indicated in fixture Schedule.
Lighting Controls: Douglas Lighting Control or Lighting Control and Design.
Day Lighting Controls: Step dimming ballast and photo sensors for automatic controls.

16620 – Emergency Power Distribution


Each automatic transfer switch will be 4-pole and provided with the bypass isolation feature. The bypass isolation
switch will provide a safe and convenient means of manually bypassing and isolating the automatic transfer switch
regardless of the condition or position of the switch. Manufacturers: Asco, Zenith and Russell Electric.

16675 – Transient Voltage Surge Suppression


Transient voltage surge suppression: Current Technology

16721 – Fire Alarm


Microprocessor-based direct wired, multi-priority peer-to-peer networked system. Manufacturer: GE Security: EST
Fire & Life Safety – EST3.

END OF OUTLINE SPECIFICATIONS

19
California Community Colleges
Final Project Proposal

FEDERAL FUNDS DETAIL

No Federal Funds are available for this project


California Community Colleges
Final Project Proposal

ANALYSIS OF FUTURE COSTS

Personnel Costs

Certificated:

The proposed project may increase the number of certificated staff assigned
to the programs and services proposed for this building. The funding for
these positions will occur as a result of the additional revenue from FTES
generated by the instructional program. It is anticipated the revenue will
offset the expenditures. Administrative staffing will remain the same.

Classified:

The proposed project may increase the number of classified or support


staff assigned to the programs and services proposed for this building.
The funding for the support staff positions will be offset by the additional
FTES funding generated by the increase in enrollment. The revenue will
offset the expenditures.

Depreciation, Maintenance, and Operation:


Community colleges are not required to depreciate the value of their
buildings. With respect to maintenance and operations, this project will
add approximately 22,168 ASF/33,100 GSF of space to the college
inventory. The college has developed a long-term funding program for
additional support staff positions and operational costs that will occur as a
result of the capital construction program. It is anticipated the costs
associated with the on-going maintenance and operation of the building
will be absorbed within the annual operating budget of the college.
Because this is a new facility, the design and construction will be in
accordance with modern, energy efficient systems and materials. This
design should minimize the day-to-day operating costs of the building.
California Community Colleges
Final Project Proposal

Analysis of Future Costs (Continued)

Program/Course/Services Approvals

List all new programs/courses/services to be housed in this project or its secondary effects and
give the date of approval. If there are no new programs/courses/services for which approval is
required, please so state. This is not required for “equipment-only” projects.

Name of New Program/Course/Service Date of Approval

__________________None_______________________ ______________________
______________________________________________ ______________________
______________________________________________ ______________________
______________________________________________ ______________________
California Community Colleges
Final Project Proposal

GUIDELINE-BASED GROUP II EQUIPMENT COST ESTIMATE-JCAF 33


District: San Bernardino Community College District Project: New Emergency Services (OE-2)
College: Crafton Hills College Prepared by: Maas Companies Date: 1-Jul-11
⌧ New Construction Reconstruction* Replacement Project*

Room Project Existing Increase in Cost/ASF per Gross Allowable Equipment Useable Total Allowable
Type # Rms 4 Digit Tops Code #/Name Space ASF Space ASF Space (ASF) Guidelines Cost in New Space/Progam Cost
110 8 0099-Classroom 6,290 3,863 2,427 $14.10 34,221 $3,600.00 30,621
210 1 1200-Laboratory-Health Occ. 1,350 1,350 $51.60 69,660 $7,200.00 62,460
210 4 2100-Laboratory-Public Serv. 4,050 4,050 $71.68 290,304 $19,500.00 270,804
215 2 2100-Lab. Serv.-Public Serv. 830 465 365 $71.68 26,163 $3,600.00 22,563
215 1 4900-Lab. Serv. -Ind. Studies 400 400 $205.02 82,008 2,200 79,808
220 1 2100-Special Class Lab. 1,200 1,208 -8 $71.68 -573 0 -573
230 1 4900-Ind. Studies Lab. 1,488 1,488 $205.02 305,070 0 305,070
310 6 0099-Office-Faculty 1,080 1,332 -252 $22.05 -5,557 0 -5,557
310 1 6000-Office-Inst. Adm. 160 160 $25.15 4,024 0 4,024
315 1 0099-Office-Service 210 210 $22.05 4,631 0 4,631
680 2 0099-Meeting Room 990 990 $22.86 22,631 1,200 21,431
740 1 2100-Veh. Storage-Pub. Ser. 4,120 4,536 -416 $0.00 0 0 0
99 1 0050-Inactive 0 891 -891 $0.00 0 0 0
29 Total ASF 22,168 12,295 9,873
Total GSF 33,100 15,730 17,370 832,582 37,300 $795,281

Total Equipment Allowance (This sum should equal the “Total Amount Needed” Column on Form B-25 ) Equipment Price Index: 3016
JUSTIFICATION FOR ADDITIONAL COSTS EXCEEDING GUIDELINES

New Construction (Including Group I Equipment) Reconstruction Equipment (Group II and Furniture)

District: San Bernardino Community College District_____ College: Crafton Hills College__________

Project: New Emergency Services (OE-2)_________________

Based on current construction costs (CCI 5394 and EPI 3016), it is anticipated that costs will not exceed the state guidelines for new
construction or equipment for this project.
Emergency Services (OE-2) --Equipment List
Location Qty. Item Description Unit Price Ext. Price

A detailed Equipment List with a value of $795,281 will be included upon initial approval of the Final Project Proposal

Page 1 of 1