Xzbwr2Stt24: Product Data Sheet

The document provides a product data sheet for the programmable receiver XZBWR2STT24, detailing its characteristics, specifications, and compatibility with radio transmitters. It features 4 PNP outputs, operates at 24 V DC, and utilizes ZigBee communication protocol. The document also includes information on environmental standards, mounting instructions, and compliance with various electrical safety regulations.

Uploaded by

ksai62797
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views9 pages

Xzbwr2Stt24: Product Data Sheet

The document provides a product data sheet for the programmable receiver XZBWR2STT24, detailing its characteristics, specifications, and compatibility with radio transmitters. It features 4 PNP outputs, operates at 24 V DC, and utilizes ZigBee communication protocol. The document also includes information on environmental standards, mounting instructions, and compliance with various electrical safety regulations.

Uploaded by

ksai62797
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Product data sheet XZBWR2STT24

Characteristics programmable receiver - 4 PNP - 200 mA - 24 V


DC - 2 pusbuttons - 6 LEDs

Main

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Programmable receiver
Device application Interface to PLC
Product compatibility Radio transmitter XZBWE

Complementary
Function of module Receiver unit for remote sensor
Number of transceivers <= 2 by ZigBee
Nominal output current 0.8 A at 24 V DC
Output type Transistor PNP
Output contacts 4 PNP
Time delay range 0.5 s (tolerance: - 15...15 %)
Starting time <= 400 ms
Maximum switching current 200 mA DC
Minimum switching current 10 mA
[Us] rated supply voltage 24 V DC (- 15...20 %)
Voltage drop <= 2 V (nominal output current: 200 mA)
Communication port protocol Zigbee green power at 2.4 GHz
Maximum sensing distance 100 m in free field
25 m in a metal enclosure
Response time < 30 ms after sensor change
Number of channels <= 2 per receiver
Utilisation category DC-13 conforming to EN/IEC 60947-5-1
Power consumption in W 26 W DC
Breaking capacity 4.8 W per output
Short-circuit protection 1 A by fast blow fuse
Operating position Any position without derating
Electrical connection 1 conductor cable 0.14...2.5 mm² AWG 26...AWG 14 solid without cable end conforming to IEC
60947-1
2 conductors cable 0.14...1.5 mm² AWG 26...AWG 16 solid without cable end conforming to IEC
60947-1
1 conductor cable 0.14...4 mm² AWG 26...AWG 12 flexible with cable end conforming to IEC 60947-1
2 conductors cable 0.14...1.5 mm² AWG 26...AWG 16 flexible with cable end conforming to IEC
60947-1

Dec 28, 2017


1
Tightening torque 0.5...1 N.m conforming to EN/IEC 60947-1
Housing material Self-extinguishing plastic
Status LED Power ON: 1 LED green
Reception signal: 1 LED green and yellow
Output active: 4 LEDs green
Mounting support Mounting plate
35 mm symmetrical DIN rail conforming to EN/IEC 60715
Rated short-duration power frequency 1 kV at 50 Hz conforming to EN/IEC 60947-5-1
withstand voltage
[Uimp] rated impulse withstand voltage 0.8 kV
Width 36 mm
Height 108 mm
Depth 75 mm
Product weight 0.13 kg
Marking CE

Environment
Surge withstand Differential mode: 0.5 kV conforming to IEC 61000-4-5
Common mode: 1 kV conforming to IEC 61000-4-5
Standards EN/IEC 60947-5-1
EN/IEC 60947-1
Ambient air temperature for storage -40...70 °C
Relative humidity 90 % without condensation (-20...55 °C) conforming to ETSI EN 300 328
Vibration resistance +/- 7.5 mm (5...14 Hz) conforming to IEC 60068-2-6
2 gn (8...150 Hz) conforming to IEC 60068-2-6
Shock resistance 10 gn with 6000 shocks during 16 ms conforming to IEC 60068-2-27
IP degree of protection Casing: IP20 conforming to IEC 60529
Terminals: IP20 conforming to IEC 60529
Pollution degree 2 conforming to IEC 60664-1
Overvoltage category III conforming to IEC 60664-1
Insulation resistance > 500 MOhm at 500 V DC conforming to NF C 20-030
[Ui] rated insulation voltage < 60 V conforming to IEC 60664-1
Electromagnetic compatibility Conducted and radiated emissions class B conforming to CISPR 22
Electrostatic discharge immunity test 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electrostatic discharge immunity test 6 kV on contact (on metal parts) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m, 80 MHz...1 GHz at 3 m conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields 3 V/m, 1.4 MHz…2 GHz at 3 m conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test 2 kV power supply wires conforming to IEC 61000-4-4
Conducted RF disturbances 10 V conforming to IEC 61000-4-6
Radiated emission conforming to ETSI EN 301 489-17
Conducted emission conforming to ETSI EN 301 489-17
Radiated emission conforming to ETSI EN 300 328
Electrical fast transient/burst immunity test 1 kV PNP output wires conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test 0.5 kV differential mode conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test 1 kV common mode conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops 7 ms conforming to IEC 61000-4-11
Immunity for industrial environments conforming to EN/IEC 61000-6-2

Offer Sustainability
Sustainable offer status Not Green Premium product
RoHS (date code: YYWW) Compliant - since 1510 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold

2
Product data sheet XZBWR2STT24
Dimensions Drawings

Receiver Dimensions

3
Product data sheet XZBWR2STT24
Connections and Schema

Receiver Wiring Diagram

(1) 400 mA fast-blow fuse


(2) Imax = 200 mA

4
Product data sheet XZBWR2STT24
Mounting and Clearance

Receiver Mounting

5
Product data sheet XZBWR2STT24
Mounting and Clearance

Receiver Mounting

6
Product data sheet XZBWR2STT24
Mounting and Clearance

Receiver Mounting

(1) Drive
(2) Power Supply or PLC

7
Product data sheet XZBWR2STT24
Mounting and Clearance

Unobstructed Mounting

(1) Typical values that may be modified by the application environment.

8
Product data sheet XZBWR2STT24
Mounting and Clearance

Mounting in a Metal Cabinet

(1) Typical values that may be modified by the application environment.