Data Sheet
Controller
Microprocessor
Control of:
Conductivity
pH
ORP
Chemical Feed
Biocide Feed
Service Reports
4-20mA In & Outs
Key Features Application
• Customizable LCD Display MegaTron XS controllers combine industry
• On Board History Graphs leading user-friendliness, affordability and
• Simple ATM Style Menu capability in one compact controller.
• One Point Calibration
• Internet Communications Option Units can be configured to control a wide
range of digital and analog inputs. Advanced
• 5 Assignable Relays
relay logic and customization let you configure
• Relay Test Keys
a unit to meet your specific system needs.
• Customizable Notepad
• Multi-Level Security Code
XS units can control cooling tower, boiler,
• LSI or RSI Index with pH waste water and other industrial applications
• 2 Year Replacement Warranty plus provide web-based communications and
• USB History Access reporting with WebAdvantage.
Build a Model Specifications
The model number starts with XS followed by the code Electrical
for each function needed for the first system. (XSCPF3E) • Input: 95-240 VAC, 50/60 Hz
• Control: Equal to input voltage (95-240VAC)
Once the main control functions have been selected, fused at 2.5A per relay
insert another - and list the desired common options.
Prewired units are supplied with an 8’ (248.84 cm)
(XSCPF5-H1).
power cord and 8” (20.32 cm) output receptacles.
Conductivity Control
B2 = BE-32 Standard Boiler probe Operational
C = TE-4A Standard Tower probe • Display: 240 X 128 Graphic LCD
• Conductivity Control: uS/cm, mS/Cm, PPM scales
Make-up / Misc. Conductivity with ranges up to 50,000 depending on sensor selection.
M = DI-4A Standard Make-up probe Boiler sampling: continuous, timed or sample and hold.
M9 = Floor drain conductivity alarm sensor • pH: 0-14 scale
PH Control • ORP: +/- 1000 millivolts scale
P = TPE-21 Standard Tower probe The ORP setpoint can be tied to an optional
28-day feed timer as an override.
ORP Control • Accuracy: +/- 1%
R = TOE-21 Standard ORP probe • Feed Timers are all selectable from:
Pulse - water meter activated w/accumulator
Feed Timers (max of 5 per system)
F3 = 3 selectable feed timers
Recycle - OFF and ON cycle; HH:MM:SS
F5 = 5 selectable feed timers Limit - Limits feed with bleed
Post - 1-100% of post bleed or other time with
Flow Switch an over all limit.
E = Flow Switch 28 Day - biocide timer.
OPTIONS Enclosure
A - Conduit connection Heavy duty NEMA 4X style high impact
A3 - Conduit with CE approval ABS with padlockable gasketed
H - Internet card w/ CAT5 connection and Wi-fi
Lexan viewing door.
Cellular options available. Consult factory.
H11 - Internet card w/ CAT5 and Modbus TCP/IP
H21 - Internet card w/ CAT5 and BACnet TCP/IP Environment
N4 - (4) 4-20mA Inputs Ambient temperature: 0o to 125oF (-17 to 52oC)
N8 - (8) 4-20mA Inputs (O4 option not available) Relative humidity: 0 to 100%
O4 - (4) 4-20mA Outputs
W1 - (1) auxiliary flow input for a bleed flow alarm Electrodes
W4 - (4) Auxiliary flow meter inputs Tower Standard electrodes are supplied in 3/4” (1.91 cm)
Y - Agency Approval (ETL, US&C) SCH 80 PVC female slip tees with quick release nut.
• Conductivity: TE-4A 150 psi (10.3 bar) / 140oF (60oC) Max
NOTES:
• pH: TPE-21 100 psi (6.8 bar) / 140oF (60oC) Max
1. Timers selectable (pulse, %, post bleed, recycle or
• ORP: TOE-21 100 psi (6.8 bar) / 140oF (60oC) Max
28-day). Each system has 2 water meter inputs.
2. All expansion slots provided. • Temperature: TC-1 150 psi (10.3 bar) / 140oF (60oC) Max
3. MegaTron XS controllers can have 4 probes max. Boiler Conductivity electrodes are supplied with 1”
4. MegaTron XS controllers have 5 relays max. (2.54 cm) MNPT XS threads.
5. Boiler conductivity should only be used on continuous • Conductivity: BE-32 250 psi @ 400°F / 350 psig @ 265°F
or surface lines; not bottom blowdown lines. PEEK core
6. LSI or RSI index included with pH if unit has tower
conductivity. Shipping Weight: Approximately 8 lbs. (3.62 kg)
7. Dual boiler unit model (i.e. XSB2F3-B2-H1) Dimensions:
W 10” (28.4 cm) x H 12” (30.5 cm) x D 7.25” (18.4 cm)
Contact the factory for a complete option list.