Denison Hydraulics Unloading Valves: Series R4U

The document provides detailed service information and model coding for Denison Hydraulics' Series R4U unloading valves. It outlines various specifications including mounting options, pressure settings, control types, and solenoid voltage. The model code system is explained, allowing for customization based on specific requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views8 pages

Denison Hydraulics Unloading Valves: Series R4U

The document provides detailed service information and model coding for Denison Hydraulics' Series R4U unloading valves. It outlines various specifications including mounting options, pressure settings, control types, and solenoid voltage. The model code system is explained, allowing for customization based on specific requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

DENISON HYDRAULICS

Unloading Valves
Series R4U

Publ. S3-ML 2500-B, replaces S3-ML 2500-A


R4U03
2

SERVICE INFORMATION
1) Mounted dependent on function.
Je nach Funktion montiert.
Monté suivant la fonction.
Montaggio conforme alla funzione.
Se monta dependiendo de la función.
R4U06
3

SERVICE INFORMATION
1) Mounted dependent on function.
Je nach Funktion montiert.
Monté suivant la fonction.
Montaggio conforme alla funzione.
Se monta dependiendo de la función.
R4U10
4

SERVICE INFORMATION
1) Mounted dependent on function.
Je nach Funktion montiert.
Monté suivant la fonction.
Montaggio conforme alla funzione.
Se monta dependiendo de la función.
SERVICE INFORMATION
5
SERVICE INFORMATION
6
SERVICE INFORMATION
7
MODEL CODE

omit
for version
without
VV01
Model Number: R4U .. – . . . – . . – .. – ... – A 1 –
1 2 3 4 5 6 7 8 9 10 11 12
1 Series
R4U = Unloading Valve
2 Size
03 = 3⁄8HH
06 = 3⁄4HH, 1HH
10 = 11⁄4HH
3 Max. Pressure
0 = for cartridges only
5 = for body valves only k 350 bar
4 Body Mounting
Cartridge with pilot valve:
0 = without Y1 port
G = Y1 port = G 1⁄4HH
E = Y1 port = SAE-4 (7⁄16HH–20 UNF)
Subplate mounting:
3 = without Y1 port
9 = Y1 port = G 1⁄4HH
7 = Y1 port = SAE-4 (7⁄16HH–20 UNF)
Threaded body:

k
6 = R4U03 = G 1⁄2HH T-body
= R4U06 = G 1HH T-body
X, Y1 ports 1) = G 1⁄4HH
D = R4U06 = G 3⁄4HH L-body
1
= R4U10 = G 1 ⁄4HH L-body

k
4 = R4U03 = SAE– 8 T-body
= R4U06 = SAE–16 T-body
X, Y1 ports 1) = SAE-4
B = R4U06 = SAE–12 L-body
(7⁄16HH–20 UNF)
= R4U10 = SAE–20 L-body
1) Port Y1 is only available at Drain line (code 2) external

from the pilot head


5 Pressure Setting Range
1 = 7...105 bar (pressure differential nominal 28 %)
3 = 7...210 bar (pressure differential nominal 28 %)
5 = 7...350 bar (pressure differential nominal 15 %)
6 Type of Control
1 = Hand knob 32 mm dia.
2 = Hand knob 50 mm dia. (not for version with vent valve VV01)
3 = Acorn nut with lead seal
4 = Adjusting device with key lock, key order no. 700–70619-8
7 Drain Line (Ports Y, Y1)
0 = internal
1 = external from the subplate/manifold (Y)
2 = external from the pilot head (Y1); (not for Body mounting codes 0 or 3)
8 3-Way Vent Valve VV01
09 = with manual override Solenoid de-energized: open to tank
10 = without manual override k Solenoid energized: vent line blocked
11 = with manual override Solenoid de-energized: vent line blocked
12 = without manual override k Solenoid energized: open to tank
9 Solenoid Voltage and Current
W01 = 115 V / 60 Hz
W02 = 230 V / 60 Hz
W06 = 115 V / 50 Hz
W07 = 230 V / 50 Hz
k
AC
G0R = 12 V
G0Q = 24 V
G0H = 48 V k DC

0 Design Letter
1 Seal Class
1 = NBR-seals (Standard)
4 = EPDM-seals
5 = FPM-seals (Viton`)
2 Modifications