Plumbing 1

The document outlines plumbing notes based on the Philippine Plumbing Code, emphasizing compliance with national and municipal laws. Key points include the use of PVC pipes, specifications for septic vault outlet pipes, and the requirement for supervision by a licensed sanitary engineer. It also mandates that all materials be new and free from defects, and that existing utilities be verified by the contractor.

Uploaded by

kimzyrylle75
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

Plumbing 1

The document outlines plumbing notes based on the Philippine Plumbing Code, emphasizing compliance with national and municipal laws. Key points include the use of PVC pipes, specifications for septic vault outlet pipes, and the requirement for supervision by a licensed sanitary engineer. It also mandates that all materials be new and free from defects, and that existing utilities be verified by the contractor.

Uploaded by

kimzyrylle75
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PLUMBING NOTES:

FROM THE LATEST EDITION OF THE PHILIPPINE PLUMBING CODE, ALL NATIONAL &
MUNICIPAL LAWS PERTINENT TO THE PRACTICE OF SANITARY ENGINEERING &
THE REQUIREMENT OF THE LOCAL UTILITIES COMPANY.

1. ALL PLUMBING WORKS HEREIN SHALL CONFORM WITH THE RULES & REGULATION;
2. ALL WATER & WASTE PIPE SHALL BE POLYVINYL CHLORIDE PIPES, SCH.40 SIZES
AS INDICATED ON THE PLANS AND SPECS;
3. NOMINAL SIZE OF OUTLET PIPE FROM SEPTIC VAULT TO MAIN STREET SEWER LINE SHALL
NOT BE LESS THAN 100 mm Ø & SHALL BE PROVIDED WITH 2% ADEQUATE NOMINAL SLOPE;
4. ALL MATERIALS/EQUIPMENT TO BE INSTALLED SHALL BE NEW & FREE FROM ANY DEFECT
14876 14876 & AS TO APPROVE AS TO LOCATION AND PURPOSE;
2500 8150 4226 2500 8150 4226 5. ALL WORKS HEREIN SHALL BE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED
SANITARY ENGINEER/MASTER PLUMBER;
3300 1500 3350 1200 3026
1800 1500 4850 1200 3026
6. TOP OF CATCH BASIN COVER SHALL BE AT GRADE LEVEL;
7. MINIMUM SLOPE OF SEWER & DRAIN PIPES SHALL BE 1.0%;
8. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION DEPTH &
INVERT ELEVATION OF ALL EXISTING PIPES & STRUCTURES AS VERIFIED BY THE CONTRACTOR;
9. THE CONTRACTOR SHALL VERIFY ALL EXISTINGS UTILITIES @ SITE & COORDINATE THE WORK
3000

3000

3000

3000
Rear WITH THE SEWER LINE EFFLUENT DISPOSAL POINT & WATERLINE SERVICE CONNECTING POINT.
Lawn

GV
comp. comp.
PLUMBING LEGEND:
LT table
tv console SHO tv console
table

closet

closet
6"Ø SEWER LINE GROUND CLEAN OUT
tv console

GCO
Storage Dining

3000

3000
3050

3050
Lanai WC COLD WATER LINE SS SOIL STACK
Area Bedroom Bedroom
Area
01 LAV 02 4" Ø VENT LINE VSTR VENT STACK THRU ROOF
PPR PIPE RISER PPR PIPE RISER
GV 4" Ø PVC PIPE

s i d e w a l k
25Ø CWL 25Ø CWL GV GATE VALVE
GATE VALVE CO CLEAN OUT
CLEAN OUT WM WATER METER

1300
7700

KS Kitchen DN LAV h a l l w a y DN
B.fast Nook

FLOOR CLEAN OUT HB HOSE BIBB

2700

2700
Area
Powder

9200

9200
WC WATER CLOSET CB CATCH BASIN
15790

15790
9700
Rm.

comp.
HB closet

table
UP DS DOWNSPOUT
WC KS KITCHEN SINK
GV GV MH MANHOLE
arc way HB W.I.C. LS LAUNDRY SINK
LAV LAVATORY VS VENT STACK
Side
25 Ø PPR

tv console
Lawn Prayer Master ST SEPTIC TANK
SHO SHOWER
25 Ø PPR

5350
Room Living Bedroom DWV DRAINAGE WASTE VENT
LAV Bedroom FD FLOOR DRAIN
3500

3500
Area Garden
Area T&B 03 CWL COLD WATER LINE
SHOWER DRAIN
9740

9740
SD
WC SHO BD BALCONY DRAIN

tv console
GV
25 Ø PPR
25Ø CWL 25Ø CWL
1600

PORCH
HB Lower Roof RISER DIAGRAM sho sho
5090

2200
2 Car PPR PIPE RISER PPR PIPE RISER
CV Garage
3590

3590
gv gv
3090

Garden Terrace
WM Area wc lav wc lav
1990

1390
GV
SECOND FLOOR T&B T&B

s i d e w a l k
from gv wm cv gv gv
5825 2675 2350 water hb hb ks lt wc lav hb
supply
3325 1925 3100 1000
TAP FROM 3300 1950 3100 2500 9350 3026 GROUND FLOOR KIT / KAUNDRY POWDER ROOM
WATER SOURCE
5800 5050 1000 3026 14876 CWL vstr

2500 8350 4026

14876
sd lav wc lav wc sd
co co
SECOND FLOOR

ks lt lav fd wc
co co
GROUND FLOOR
ST

DWV
SCALE: SCALE: SCALE:
GROUND FLOOR CWL LAYOUT 1:100MM
1 SECOND FLOOR CWL LAYOUT 1:100MM
2 PLUMBING NOTES/ LEGEND/ RISER DIAGRAM N.T.S.
3
NOTES : PROJECT TITLE: OWNER: PRINTS REVISIONS SHEET CONTENTS DRAWN BY: SHEET NO.
Drawings and specifications and other
7C TAGALA CONSTRUCTION Co. contract documents duly signed,
stamped or sealed, as instruments of
REDENTOR TAGALA, UAP LUDYVILLA A. VISTA
NO. COPY FURNISH DATE:
ARCHITECT * CONTRACTOR * INTERIOR DESIGNER service, are the intellectual property
and documents of the Architect, ARCHITECT MASTER PLUMBER PROPOSED 1
B29 L03 BROOKESIDE LANE ARNALDO HIGHWAY
whether the object for which they are
made is executed or not. It shall be
MR. & MRS. LAURO M. LANDICHO DATE: SEP 2019
SAN FRANCISCO GENERAL TRIAS, CAVITE
unlawful for any person to duplicate or PRC#: 13870 PRC#: 8902 TWO STOREY RESIDENCE 2
RESIDENCE TEL# (046) 538 2703 / OFFICE TEL.# 09228937717
to make copies of said documents for
use in the repetition of and for other
projects or buildings, whether executed
TIN#: 184-603-516 TIN#: 915-232-761
3
CHECKED BY: P-01
MOBILE : 09175517430 / 09228937737 partly or in whole, without the written IAPOA#: 13041-240043-093018 LOCATION: ADDRESS: RED