0% found this document useful (0 votes)
348 views9 pages

HYUNDAI Supercored 71

Supercored 71 is a flux cored arc welding consumable designed for welding mild and high tensile steel, with specifications conforming to various standards including AWS A5.20 and EN ISO 17632-A. It offers good usability across all positions, excellent slag detachability, and strong mechanical properties, with tensile strength ranging from 572 to 586 MPa depending on wire diameter. The document also outlines proper welding conditions, approvals, and the chemical composition of the weld metal.

Uploaded by

a.rahbardoost
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
348 views9 pages

HYUNDAI Supercored 71

Supercored 71 is a flux cored arc welding consumable designed for welding mild and high tensile steel, with specifications conforming to various standards including AWS A5.20 and EN ISO 17632-A. It offers good usability across all positions, excellent slag detachability, and strong mechanical properties, with tensile strength ranging from 572 to 586 MPa depending on wire diameter. The document also outlines proper welding conditions, approvals, and the chemical composition of the weld metal.

Uploaded by

a.rahbardoost
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Rev.

06

Supercored 71
FLUX CORED ARC WELDING CONSUMABLE
FOR WELDING OF MILD & 490MPa CLASS
HIGH TENSILE STEEL

2022.02

HYUNDAI WELDING CO., LTD.


Supercored 71

v Specification AWS A5.20 E71T-1C

(AWS A5.20M E491T-1C)

EN ISO 17632-A T42 2 P C1 1

JIS Z3313 T49 2 T1-1 C A

AWS D1.8

Wire Dia. mm(in)

1.2(0.045) 1.4(0.052) 1.6(1/16)

* AWS D1.8 is available upon request

v Applications All position welding of machinery, shipbuilding, bridges. Impact


values of weld metal are good.

v Characteristics Supercored 71 is a flux cored wire which has been designed to get
on Usage a good usability in all position for wide range of welding currents.
With its quiet and smooth arc, its slag detachability is very good.

v Note on Usage 1. For preheating guidelines, please refer to your local standards and
codes relative to your best practices

2. One-side welding defects such as hot cracking may occur with


wrong welding parameter such as high welding speed.

3. Use 100% CO₂gas.


Supercored 71
Mechanical Properties
& Chemical Composition of All Weld Metal

v Welding Conditions Method by AWS Spec.

Welding Position : 1G(PA)


Diameter : 1.2mm (0.045in)

Shielding Gas : 100%CO₂

Flow Rate : 20 ℓ /min

Amp./ Volt. : 280A / 32V

Stick-Out : 20~25mm (0.79~0.98in)

Pre-Heat : R.T .

Interpass Temp. : 150±15℃ (302±59℉)

[ Joint Preparation & Layer Details ] Polarity : DC(+)

v Mechanical Properties of all weld metal

CVN Impact Test


Consumable Tensile Test
J(ft·lbs)

YS TS EL -1℃ -18℃
MPa (lbs/in2) MPa (lbs/in2) (%) (30℉) (0℉)
Supercored 71
545 (79,000) 572 (83,000) 28 110 (81) 70 (52)

490~670
AWS A5.20 ≥ 390 ≥27J at –18℃
(70,000~ ≥ 22
E71T-1C (56,000) (≥20ft·lbs at 0℉)
97,000)

v Chemical Analysis of all weld metal(wt%)

Consumable C Si Mn P S

Supercored 71 0.036 0.51 1.26 0.010 0.011

AWS A5.20
≤ 0.12 ≤ 0.9 ≤ 1.75 ≤ 0.03 ≤ 0.03
E71T-1C

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71
Mechanical Properties
& Chemical Composition of All Weld Metal

v Welding Conditions Method by AWS Spec.

Welding Position : 1G(PA)


Diameter : 1.4mm (0.052in)

Shielding Gas : 100%CO₂

Flow Rate : 20 ℓ /min

Amp./ Volt. : 300A / 32V

Stick-Out : 20~25mm (0.79~0.98in)

Pre-Heat : R.T .

Interpass Temp. : 150±15℃ (302±59℉)

[ Joint Preparation & Layer Details ] Polarity : DC(+)

v Mechanical Properties of all weld metal

CVN Impact Test


Consumable Tensile Test
J(ft·lbs)

YS TS EL -1℃ -18℃
MPa (lbs/in2) MPa (lbs/in2) (%) (30℉) (0℉)
Supercored 71
548 (79,000) 576 (84,000) 28 128 (94) 81 (60)

490~670
AWS A5.20 ≥ 390 ≥27J at –18℃
(70,000~ ≥ 22
E71T-1C (56,000) (≥20ft·lbs at 0℉)
97,000)

v Chemical Analysis of all weld metal(wt%)

Consumable C Si Mn P S

Supercored 71 0.038 0.50 1.28 0.010 0.011

AWS A5.20
≤ 0.12 ≤ 0.9 ≤ 1.75 ≤ 0.03 ≤ 0.03
E71T-1C

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71
Mechanical Properties
& Chemical Composition of All Weld Metal

v Welding Conditions Method by AWS Spec.

Welding Position : 1G(PA)


Diameter : 1.6mm (1/16in)

Shielding Gas : 100%CO₂

Flow Rate : 20 ℓ /min

Amp./ Volt. : 320~330A / 29~30V

Stick-Out : 20~25mm (0.79~0.98in)

Pre-Heat : R.T .

Interpass Temp. : 150±15℃ (302±59℉)


[ Joint Preparation & Layer Details ] Polarity : DC(+)

v Mechanical Properties of all weld metal

CVN Impact Test


Consumable Tensile Test
J(ft·lbs)

YS TS EL -1℃ -18℃
MPa (lbs/in2) MPa (lbs/in2) (%) (30℉) (0℉)
Supercored 71
551 (80,000) 586 (85,000) 27.5 105 (77) 66 (49)

490~670
AWS A5.20 ≥ 390 ≥27J at –18℃
(70,000~ ≥ 22
E71T-1C (56,000) (≥20ft·lbs at 0℉)
97,000)

v Chemical Analysis of all weld metal(wt%)

Consumable C Si Mn P S

Supercored 71 0.033 0.49 1.30 0.011 0.010

AWS A5.20
≤ 0.12 ≤ 0.9 ≤ 1.75 ≤ 0.03 ≤ 0.03
E71T-1C

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71

Welding Efficiency

v Deposition Rate & Efficiency

Welding
Wire Feed Deposition Deposition
Consumable Conditions
Speed Efficiency Rate
(size)
Amp.(A) Volt.(V) m/min (in/min) % kg/hr(lb/hr)

200 26 10.2 (400) 84~87 3.4 (7.5)


Supercored 71

250 28 11.5 (450) 85~88 4.5 (9.9)


1.2mm
(0.045in)
300 33 15.3 (600) 86~88 5.2 (11.4)

250 28 7.6 (300) 85~87 3.9 (8.6)


Supercored 71

300 32 10.2 (400) 85~88 4.8 (10.6)


1.4mm
(0.052in)
330 36 12.8 (500) 86~89 5.8 (12.8)

280 31 6.4 (250) 85~88 4.2 (9.2)

Supercored 71
330 33 7.6 (300) 86~88 4.8 (10.6)

1.6mm
350 34 8.1 (320) 87~89 5.3 (11.7)
(1/16in)

400 38 9.2 (360) 87~90 5.7 (12.5)

Deposition
Deposition rate
efficiency
=(Deposited metal
=(Deposited metal
Remark weight/
weight/
Welding
Wire weight
time,min.)×60
used)×100

* Shielding Gas : 100%CO₂

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71

Diffusible Hydrogen Content

v Welding Conditions

Diameter : 1.2mm (0.045in) Amps(A) / Volts(V) : 230A / 26V

Shielding Gas : 100%CO₂ 20~25mm


Stick-Out :
(0.79~0.98in)
Flow Rate : 20 ℓ /min
30 cm/min
Welding Position : 1G (PA) Welding Speed :
(12 in/min)
Current Type & Polarity : DC(+)

v Hydrogen Analysis Using Gas Chromatography Method


Hydrogen Evolution Time : 72 hrs
Evolution Temp. : 45 ℃ (113℉)

Barometric Pressure : 780 mm-Hg

v Result(㎖/100g Weld Metal)

X1 X2 X3 X4

5.3 5.4 5.4 5.4

Average Hydrogen Content 5.4 ㎖ / 100g Weld Metal

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71

Proper Welding Condition

v Proper Current Range

Wire Dia,
Shielding Welding
Consumable
Gas Position
1.2mm 1.4mm 1.6mm
(0.045in) (0.052in) (1/16in)

F & HF 120~300Amp 150~350Amp 150~360Amp

Supercored V-Up & OH


100%CO₂ 120~260Amp 140~270Amp 160~280mp
71

V-Down 200~300Amp 220~320Amp 250~300Amp

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.
Supercored 71

Approvals

v Shipping Approvals

Register of shipping & Size


Welding
Position
KR ABS LR BV DNV NK

KSW53G©H10
3SMG, 3SAH10, 3S, 3YSH10 SA3M,3YMHH IIIYMSH10
KAW53MG©H10
3YSMG 3YSA A3M,3YMHH
All ©H10
V-Down
0.9~1.6mm
0.9~1.6mm 0.9~1.6mm 0.9~1.6mm 0.9~1.6mm 0.9~1.6mm
(0.035~1/16in)
(0.035~1/16in) (0.035~1/16in) (0.035~1/16in) (0.035~1/16in) (0.035~1/16in)

v F No & A No

F No A No

6 1

This information is provided solely for the purpose of confirming product conformance with applicable standards. The serviceability of a product or
structure utilizing this type of information is and must be the sole responsibility of the builder/user. Many variables beyond the control of HYUNDAI
WELDING CO., LTD. affect the results obtained in applying this type of information. These variables include, but are not limited to, welding procedure,
shielding gas, plate chemistry and temperature, weldment design, fabrication methods and service requirements.

You might also like