0% found this document useful (0 votes)
316 views2 pages

Sun bk60 100sg01 Eu Am2

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
316 views2 pages

Sun bk60 100sg01 Eu Am2

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Micro Hybrid Inverter

SUN-BK60/80/100/SG01-EU-AM2

Model No.: SUN-BK80SG01-EU-AM2 Load Data


Product type Balcony energy storage Micro-inverter AC Output Voltage L/N/PE 230Va.c.

IP67 protection degree


Enclosure IP67 AC Output Frequency 50/60Hz
Ambient Temperature -40 to +65℃( >45℃ derating ) Max. AC Output Current 3.9Aa.c.
Protection Level Class I Max. Apparent Output Power 880VA
Over Voltage Category III (AC), II (DC) Peak Output Power 1600W 10Seconds
Inverter topology Isolated
This Grid support interactive inverter complies with
PV Input Data IEC/EN 62109-1, IEC/EN 62109-2
Max. PV Input Power 1000W
Max. PV Input Voltage 60Vd.c
MPPT Input Range 20Vd.c.-50Vd.c.
Max. PV Input Current 18Ad.c.+18Ad.c.
Max. PV ISC 27Ad.c.+27Ad.c.
Battery Data
Battery Type
Battery Voltage
Max. Charging /Discharging Current

AC Input/Output Data
Lithium-ion
40V-60Vd.c.
25Ad.c.
-Both AC and DC voltage sources are terminated inside this
equipment.
-Each circuit must be individually disconnected before
servicing.
-Photovoltaic array supplied a DC voltage to this equipment
when exposed to light.
WIFI communication
AC Input/Output Voltage L/N/PE 230Va.c.
-Hot surface: To reduce the risk of burn - Do not touch.
AC Input/Output Frequency 50/60Hz
AC Input/Output Rated Current 3.5Aa.c.
-Please read the instructions carefully before use.
Max. AC Input/Output Current 3.9Aa.c. -To be connected to a dedicated branch circuit.
-Do Not put it in the waste bin! Recycle it by licensed

Wireless CT, Wireless Smart Switch and Wireless BMS


AC Input/Output Rated Power 800W
Max. Apparent Input/Output Power 880VA professional!
Max. Continuous AC Passthrough 10Aa.c. NINGBO DEYE INVERTER TECHNOLOGY CO., LTD.
AC Power Factor 0.8 leading to 0.8 lagging Add.: No.26 South YongJiang Road, Daqi, Beilun, NingBo, China

communication
AC couple to retrofit existing solar system
Max. charging/discharging current 25A
Expand two independent PV inputs
Working in Microinverter mode or storage inverter mode
Supports UPS load, fast switching within 4ms

Stock Code: 605117.SH


Technical Data www.deyeinverter.com

Model SUN-BK60SG01-EU-AM2 SUN-BK80SG01-EU-AM2 SUN-BK100SG01-EU-AM2

Battery Input Data


Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 25
Max. Discharging Current (A) 25
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 1320 1760 2200
Max. PV Input Power (W) 960 1280 1600
Max. PV Input Voltage (V) 60
Start-up Voltage (V) 25
MPPT Voltage Range (V) 20-55
Rated PV Input Voltage (V) 42.5
Max. Operating PV Input Current (A) 18+18
Max. Input Short-Circuit Current (A) 27+27
No. of MPP Trackers/
2/1
No. of Strings per MPP Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 600 800 1000
Max. AC Input/Output Active Power (W) 660 880 1100
Max. AC Input/Output Apparent Power (VA) 660 880 1100
Rated AC Input/Output Current (A) 2.8/2.7 3.7/3.5 4.6/4.4
Max. AC Input/Output Current (A) 3/2.9 4/3.9 5/4.8
Max. Continuous AC Passthrough (grid to load) (A) 10
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 96.5%
Euro Efficiency 96.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection
Overvoltage Load Drop Protection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
General Data
Operating Temperature Range () -40 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise (dB) ≤25
Ingress Protection(IP) Rating IP 67
Inverter Topology Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

Communication Wi-Fi, Lora, Bluetooth


Cabinet Size (WxHxD mm) 364.5×183×32.85 (Excluding Connectors and Brackets)
Weight (kg) 4.3
Type of Cooling Natural Cooling
10 Years/15 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
G98, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Ningbo Deye Inverter Technology Co., Ltd.


Address: No. 26 South YongJiang Road, Daqi, Beilun, NingBo, Zhejiang, China. | Tel: +86 (0)574 86228841 | E-mail: market@deye.com.cn

You might also like