0% found this document useful (0 votes)
46 views32 pages

Cable Cleat Brochure

Panduit offers a comprehensive range of cable cleats designed for short circuit protection, ensuring safety and minimizing damage during faults. The cleats are engineered for easy installation in various environments and comply with the IEC 61914 testing standard. With a focus on productivity and reliability, Panduit provides tailored solutions for industries such as oil and gas, utilities, and data centers.

Uploaded by

Ibrahim Moaaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views32 pages

Cable Cleat Brochure

Panduit offers a comprehensive range of cable cleats designed for short circuit protection, ensuring safety and minimizing damage during faults. The cleats are engineered for easy installation in various environments and comply with the IEC 61914 testing standard. With a focus on productivity and reliability, Panduit provides tailored solutions for industries such as oil and gas, utilities, and data centers.

Uploaded by

Ibrahim Moaaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Cable Cleats for

Short Circuit Protection


Discover the perfect fit for your cable containment needs with Panduit comprehensive range of cable cleat solutions.
Designed to secure cables in the event of a short circuit fault, our cable cleats prioritize safety and minimize disruption and
damage to personnel and property.
Engineered for easy installation in various applications and harsh environments, our cleats offer unmatched reliability
and safety. Choose Panduit for on-the-job productivity and peace of mind, knowing you have the right product for your
specific requirements.

REDUCE PROJECT COSTS AND INSTALLATION TIME

Tested to IEC 61914, the latest and


Simple and intuitive design
most globally recognized cable cleat
leads to increased productivity
testing standard

Collaborative and consultative approach


Compatible with a variety of
to cable cleat specification, supported
ladder racks and cables
by a team

Applications:
Industry-unique mounting
brackets and installation tool Oil and Gas, Petrochemical, Shipbuilding, Rail,
Utilities, Renewable Energy, and Data Centers

2 www.panduit.com/cable-cleats
WHY CABLE CLEATS?

EC 61914 is the most comprehensive and globally accepted cable cleat testing standard.
It provides requirements for:
• Temperature rating • Lateral load testing • Impact resistance • Resistance to
electromechanical forces
• Adequate resistance to • Axial load testing • UV resistance
flame propagation • Corrosion resistance

During a short circuit fault, maximum electromechanical


stress between conductors occurs at or before
0.005 second

Typical circuit breakers and other protection devices trip


and interrupt a fault between 0.06 to 0.1 second

Cable cleats perform their function within those first


0.005 second (i.e. at peak kA) before a circuit breaker
trips and interrupts a fault

?
...the NEC 392.20(C) doesn't specify how to protect against excessive

DID cable movement due short circuit, however IEC 61914 provides
YOU testing methology to ensure compliance to the NEC requirements.
KNOW

www.panduit.com/cable-cleats 3
SIMULATION PROGRAM

Research & Development: We have created a state-of-the-art ANSYS award-


winning program that simulates the material composition of our cable cleats and
the electromechanical forces present in a short circuit fault, preparing our cable
cleats for testing to IEC 61914 standards.
The cleats are then subjected to a live short circuit fault at a testing laboratory to
validate compliance with this standard. The simulation program is a powerful tool
that helps us select the most appropriate materials for our cleats, so they perform
to their tested kA rating during a short circuit fault.

4 www.panduit.com/cable-cleats
CLEAT kAlculator™

Selecting the right Cable Cleat


has never been so easy
Prevent damages resulting from a short circuit fault
by specifying and installing Panduit Cable Cleats
SELECT cable layout
INPUT peak short circuit current
INPUT cable diameter
Access the desktop Cable Cleat web application here:
www.panduit.com/en/support/tools1/cable-cleat-
kalculator-web-application.html

www.panduit.com/cable-cleats 5
TABLE OF CONTENTS
Panduit Cleat Overview................................................6-7
Stainless Steel Cable Cleats and Accessories
Trefoil Cleat......................................................................... 8-9
Buckle Strap Cleat......................................................... 10-11
Locking Strap Cleat........................................................ 12-13

Cable Cleat Installation Tools


BT2HTI................................................................................ 14 Product Trefoil Cleat
BT75SDT............................................................................. 14
Material Stainless Steel
PBTMT/E............................................................................. 15
Parts 12 Parts
RT2HT................................................................................. 15
Diameter 20 - 25 mm 50 - 57 mm
Mounting Brackets......................................................... 16-17 Ranges 23 - 28 mm 54 - 61 mm
Cushion Sleeve.................................................................... 17 26 - 32 mm 58 - 65 mm
30 - 36 mm 62 - 69 mm
Aluminum Cable Cleats 34 - 40 mm
38 - 44 mm
Trefoil Cleat..................................................................... 18-19 42 - 48 mm
Two-Hole Cleat............................................................... 20-21 46 - 52 mm
One-Hole Cleat............................................................... 22-23

Polymer Cable Cleats


Trefoil Cleat..................................................................... 24-25
Two-Hole Cleat............................................................... 26-27
One-Hole Cleat............................................................... 28-29

Panduit Solutions For Electrical


And Networking Installations..................................30-31

Cable Layout Legend

Flat Trefoil Quad Multicore

6 www.panduit.com/cable-cleats
PANDUIT CLEAT OVERVIEW

Product Buckle Strap Cleat Locking Strap Cleat Trefoil Cleat Two-Hole Cleat One-Hole Cleat
Material Stainless Steel Stainless Steel Aluminum Aluminum Aluminum
Parts 6 Parts 13 Parts 14 Parts 7 Parts 10 Parts
Diameter 12 - 45 mm 12 - 95 mm (5) 23 - 26 mm 43 - 47 mm 38 - 46 mm 10 - 13 mm 46 - 51
Ranges 45 - 70 mm 95 - 120 mm (1) 25 - 28 mm 46 - 51 mm 46 - 58 mm 13 - 16 mm mm
70 - 95 mm 95 - 150 mm (3) 27 - 30 mm 50 - 56 mm 58 - 70 mm 16 - 19 mm 51 - 57
95 - 120 mm 120 - 150 mm (1) 29 - 32 mm 50 - 56 mm 70 - 83 mm 19 - 23 mm mm
120 - 150 mm 150 - 195 mm (3) 31 - 35 mm 55 - 61 mm 83 - 97 mm 23 - 27 mm
150 - 170 mm 34 - 38 mm 60 - 67 mm 97 - 109 mm 27 - 32 mm
37 - 41 mm 66 – 75 mm 109 - 120 mm 32 - 38 mm
40 - 44 mm 38 - 46 mm

CUSTOM CLEAT SOLUTIONS AVAILABLE


For global engineered custom solutions and
technical support, reach out to your local
Panduit Sales Representative.
To learn more visit: www.panduit.com/cable-cleats

Trefoil Cleat Two-Hole Cleat One-Hole Cleat


Polymer Polymer Polymer
6 Parts 10 Parts 10 Parts
22 - 28 mm 38 - 46 mm 109 - 120 mm 10 - 13 mm 32 - 38 mm
26 - 33 mm 46 - 58 mm 120 - 135 mm 13 - 16 mm 38 - 46 mm
31 - 39 mm 58 - 70 mm 135 - 150 mm 16 - 19 mm 46 - 51 mm
37 - 45 mm 70 - 83 mm 150 - 165 mm 19 - 23 mm 51 - 57 mm
43 - 52 mm 83 - 97 mm 23 - 27 mm
50 - 60 mm 97 - 109 mm 27 - 32 mm

www.panduit.com/cable-cleats 7
STAINLESS STEEL TREFOIL CLEAT
The Stainless Steel Trefoil Cable Cleat offers protection against
extreme environments and high short circuit current faults. It is made of
316L stainless steel, available in multiple sizes with cable range taking
capability, and suitable for trefoil cable arrangements.
H
The cleat can be installed after running cable using a Panduit mounting
bracket or before running cable by installing direct to the cable tray rung
through a fixing hole using an M8 bolt.

Tightening bolt can W D


be installed from
top or bottom
Nylon insert
lock nut
for vibration
dampening

Removeable
spacer for cable
range taking

Mounting bracket
slot allows for
installation flexibility

8 www.panduit.com/cable-cleats
Stainless Steel Trefoil Cleat TREFOIL CLEAT
Cable Diameter Range H W D Weight

Part Number In. mm In. mm In. mm In. mm Lb. g Mounting Holes


CCSSTR2025-X 0.79 - 0.98 20 - 25 3.43 87 3.39 86 2.48 63 0.92 417 1 X M8
CCSSTR2328-X 0.91 - 1.10 23 - 28 3.58 91 3.54 90 2.48 63 0.97 439 1 X M8
CCSSTR2632-X 1.02 - 1.26 26 - 32 3.74 95 3.82 97 2.48 63 1.06 480 1 X M8
CCSSTR3036-X 1.18 - 1.42 30 - 36 3.94 100 4.13 105 2.48 63 1.14 518 1 X M8
CCSSTR3440-X 1.34 - 1.58 34 - 40 4.25 108 4.37 111 2.48 63 1.21 547 1 X M8
CCSSTR3844-X 1.50 - 1.73 38 - 44 4.25 108 4.69 119 2.48 63 1.28 581 1 X M8
CCSSTR4248-X 1.65 - 1.89 42 - 48 4.41 112 4.96 126 2.48 63 1.35 613 1 X M8
CCSSTR4652-X 1.81 - 2.05 46 - 52 4.61 117 5.24 133 2.48 63 1.43 647 1 X M8
CCSSTR5057-X 1.97 - 2.24 50 - 57 4.84 123 5.63 143 2.48 63 1.51 686 1 X M8
CCSSTR5461-X 2.13 - 2.40 54 - 61 5.12 130 5.91 150 2.48 63 1.59 720 1 X M8
CCSSTR5865-X 2.28 - 2.56 58 - 65 5.43 138 6.18 157 2.48 63 1.66 754 1 X M8
CCSSTR6269-X 2.44 - 2.72 62 - 69 5.71 145 6.50 165 2.48 63 1.72 782 1 X M8

Short Circuit Testing Summary1


Trefoil Formation Trefoil Formation Trefoil Formation Trefoil Formation
38 mm Cable Diameter 38 mm Cable Diameter 35 mm Cable Diameter 38 mm Cable Diameter
One Short Circuit Event Two Short Circuit Events One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
0.1 sec 0.1 sec 0.1 sec 0.1 sec
172 kA Peak 167 kA Peak 143 kA Peak 125 kA Peak
8926 lbs force (39.77 kN) 8415 lbs force (37.4 kN) 13398 lbs force (59.5 kN) 9429 lbs force (41.9 kN)
1
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services (IEEE, IEC, UL, and ANSI)
for electric power equipment.

www.panduit.com/cable-cleats 9
STAINLESS STEEL BUCKLE STRAP CLEAT
The Stainless Steel Buckle Strap Cleat is an effective option for W
protecting against high short circuit fault current requirements in harsh
environments. The strap is made of 316L stainless steel, has inherent
cable range-taking, and is compatible with quad, trefoil, and
multicore cables.
T

The cleat is installed after running the cable via a unique in the industry
mounting bracket. It is tensioned and cut using a manually-operated,
ratchet-style installation tool or a tension screw drive installation tool. L

The straps have rounded edges to protect from damaging the cable and
are often used in combination with a cushion sleeve inserted between
the strap and cable for added protection.

Buckle design
provides low
finished profile

Smooth
surfaces
and rounded
edges reduce
risk of cable
insulation
damage
Compatible with
a variety of cable
trays and cables

10 www.panduit.com/cable-cleats
Stainless Steel Buckle Strap Cleat BUCKLE STRAP CLEAT
Trefoil Double Loop Cable Trefoil Triple Loop Cable Flat Multicore Double Loop Strap/Tie
Diameter Range Diameter Range Cable Diameter Range Width Thickness Length

Part Number In. mm In. mm In. mm In. mm In. mm In. mm


MS4W75T30-Q6 0.47 - 0.79 12 - 20 - - 0.47 - 1.77 12 - 45 0.75 19.1 0.03 0.76 20.2 513
MS6W75T30-Q6 0.79 - 1.18 20 - 30 0.47 - 0.79 12 - 20 1.77 - 2.76 45 - 70 0.75 19.1 0.03 0.76 26.5 673
MS8W75T30-Q6 1.18 - 1.65 30 - 42 0.79 - 1.02 20 - 26 2.76 - 3.74 70 - 95 0.75 19.1 0.03 0.76 32.7 831
MS10W75T30-Q6 1.65 - 2.28 42 - 58 1.02 - 1.38 26 - 35 3.74 - 4.72 95 - 120 0.75 19.1 0.03 0.76 39.0 991
MS12W75T30-Q6 2.28 - 2.84 58 - 72 1.38 - 1.73 35 - 44 4.72 - 5.91 120 - 150 0.75 19.1 0.03 0.76 44.7 1135
MS14W75T30-Q6 2.84 - 3.39 72 - 86 1.73 - 2.09 44 - 53 5.91 - 6.69 150 - 170 0.75 19.1 0.03 0.76 50.1 1273 0.75
[19.0 ]
1.64 0.68
[41.8] [0.05]

Buckle 0.030
[0.005 ]
Body
19.6–50.1
[498-1273]
AISI
#1 FULL
ROUND EDGES

Short Circuit Testing Summary1


MS##W75T30-Q6 Double Loop Product

Trefoil Formation Trefoil Formation Trefoil Formation Trefoil Formation


37 mm Cable Diameter 38 mm Cable Diameter 39 mm Cable Diameter 39 mm Cable Diameter
One Short Circuit Event Two Short Circuit Events One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
153 kA 142 kA 109 kA 109 kA
7254 lbs force (32.3 kN) 6084 lbs force (27.1 kN) 6960 lbs force (31.0 kN) 6960 lbs force (31.0 kN)

Test compliance to IEC 61914 utilizing KEMA facility;


1

MS##W75T30-Q6 Triple Loop Product Independent, ISO 17025 accredited testing, inspection, and
Trefoil Formation Trefoil Formation certification services (IEEE, IEC, UL, and ANSI) for electric
39 mm Cable Diameter 39 mm Cable Diameter power equipment.
One Short Circuit Event Two Short Circuit Events While Panduit’s Cable Cleats are tested to meet the CSA
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing standard C22.2 No.61914 it is the responsibility of the
installer to ensure that the installation complies with all
188 kA 188 kA
applicable local codes and regulations.
10391 lbs force (46.2 kN) 10391 lbs force (46.2 kN)

www.panduit.com/cable-cleats 11
STAINLESS STEEL LOCKING STRAP CLEAT
The Stainless Steel Locking Strap Cleat is an effective option
for protecting against lower to medium short circuit fault current W

requirements in harsh environments. The strap is made of 316L stainless


steel, has inherent cable range-taking, and is compatible with quad,
trefoil, and multicore cables. T

The cleat is installed after running the cable via a unique in the industry
mounting bracket. It is tensioned and cut using a battery-operated, L
electromechanical or manually-operated, ratchet-style installation tool.
The straps have rounded edges to protect from damaging the cable and
are often used in combination with a cushion sleeve inserted between
the strap and cable for added protection.

Cable tie cut


off eliminates
exposed sharp
edges

Self-locking
head for
high-retained
tension

Smooth
surfaces
and rounded
edges reduce
risk of cable
insulation
damage

12 www.panduit.com/cable-cleats
Stainless Steel Locking Strap Cleat LOCKING STRAP CLEAT
Trefoil Double Loop Cable Flat Multicore Double Loop
Diameter Range Cable Diameter Range Width Thickness Length

Part Number In. mm In. mm In. mm In. mm In. mm


7.677
MLT4DH-L316 0.47 - 1.65 12 - 42 0.47 - 3.74 12 - 95 0.31 7.9 0.010 0.25 28.0 711
MLT4DH-L 0.47 - 1.65 12 - 42 0.47 - 3.74 12 - 95 0.31 7.9 0.010 0.25 28.0 711
MLT4DEH15-Q316 0.47 - 1.65 12 - 42 0.47 - 3.74 12 - 95 0.50 12.7 0.015 0.38 29.5 749
MLT4DSH-Q316 0.47 - 1.65 12 - 42 0.47 - 3.74 12 - 95 0.63 15.9 0.015 0.38 29.5 749
MLT4DSH-Q 0.47 - 1.65 12 - 42 0.47 - 3.74 12 - 95 0.63 15.9 0.015 0.38 29.5 749
MLT5DH-L316 1.65 - 2.28 42 - 58 3.74 - 4.72 95 - 120 0.31 7.9 0.010 0.25 34.0 863
MLT6DEH15-Q316 1.65 - 2.84 42 - 72 3.74 - 5.91 95 - 150 0.50 12.7 0.015 0.38 41.5 1054
MLT6DSH-Q316 1.65 - 2.84 42 - 72 3.74 - 5.91 95 - 150 0.62 15.9 0.015 0.38 41.5 1054
MLT6DSH-Q 1.65 - 2.84 42 - 72 3.74 - 5.91 95 - 150 0.62 15.9 0.015 0.38 41.5 1054
MLT6DH-L316 2.28 - 2.84 58 - 72 4.72 - 5.91 120 - 150 0.31 7.9 0.010 0.25 40.0 1016
MLT8DEH15-Q316 2.84 - 3.94 72 - 100 5.91 - 7.68 150 - 195 0.50 12.7 0.015 0.38 53.5 1359
MLT8DSH-Q316 2.84 - 3.94 72 - 100 5.91 - 7.68 150 - 195 0.63 15.9 0.015 0.38 53.5 1359
MLT8DSH-Q 2.84 - 3.94 72 - 100 5.91 - 7.68 150 - 195 0.63 15.9 0.015 0.38 53.5 1359

Short Circuit Testing Summary1 1


Test compliance to IEC 61914
MLT#DH-L316 Product
utilizing KEMA facility; Independent, ISO 17025
Trefoil Formation Trefoil Formation Trefoil Formation Trefoil Formation accredited testing, inspection, and certification
39 mm Cable Diameter 39 mm Cable Diameter 39 mm Cable Diameter 39 mm Cable Diameter services (IEEE, IEC, UL, and ANSI) for electric
One Short Circuit Event Two Short Circuit Events One Short Circuit Event Two Short Circuit Events power equipment.
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
While Panduit’s Cable Cleats are tested to
47.0 kA 47.0 kA 42.2 kA 33.2 kA meet the CSA standard C22.2 No.61914 it is the
649 lbs force (2.89 kN) 649 lbs force (2.89 kN) 1047 lbs force (4.66 kN) 648 lbs force (2.88 kN) responsibility of the installer to ensure that the
installation complies with all applicable local
MLT#DSH-Q316 Product codes and regulations.
Trefoil Formation Trefoil Formation Trefoil Formation Trefoil Formation
38 mm Cable Diameter 38 mm Cable Diameter 39 mm Cable Diameter 39 mm Cable Diameter
One Short Circuit Event One Short Circuit Event One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.4) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
75.1 kA 75.1 kA 60.4 kA 60.4 kA
1702 lbs force (7.57 kN) 1702 lbs force (7.57 kN) 2145 lbs force (9.45 kN) 2145 lbs force (9.45 kN)

MLT#DEH15-Q316 Product
Trefoil Formation Trefoil Formation Trefoil Formation
38 mm Cable Diameter — 39 mm Cable Diameter 39 mm Cable Diameter
One Short Circuit Event — One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
56.1 kA — 42.4 kA 35.7 kA
925 lbs force (4.11 kN) — 1057 lbs force (4.70 kN) 749 lbs force (3.33 kN)
www.panduit.com/cable-cleats 13
THE COMPLETE PANDUIT CABLE CLEAT TOOLS
The manually-operated BT2HTI and BT75SDT tools are
are used
used to
to install
install the
Panduit's
buckle Buckle
strap Strap Cleats.
cleats.
The BT2HTI is a ratchet-style
ratchet-styleinstallation
installationtool,
tool,allowing forfor
allowing high tension
high withwith
tension
minimal
minimal effort.
effort.
The BT75SDT tensions
tensions the
the strap
strapusing
usingaascrew
screwdrive
drivemechanism,
mechanism,providing high
providing
tension while while
high tension reducing operator
reducing fatigue.fatigue.
operator
Both tools
tools use
useaalever
levertotocut
cutthethestrap
strapsosothere is is
there anan
appropriate
appropriate length
lengthremaining
to fold overtoand
remaining foldsecure with secure
over and the buckle
withtab.
the Abuckle
side entry
tab. slot allows
A side entryforslot
easy strap
allows
insertion, streamlining
for easy strap insertion,installation. The installation.
streamlining BT2HTI is more Thesuitable
BT2HTIfor highersuitable
is more volume
installations, and the
for higher volume BT75SDT for
installations, andlower volume. for lower volume.
the BT75SDT

BT2HTI

For use with


Stainless Steel
Buckle Strap Cleats

Length Width Std


Part Pkg.
Number Description In. mm In. mm Used With Qty.
BT2HTI Installation tool for use with 6.94 176 7.64 194 Stainless 1
MS75 buckles. Steel Buckle
Strap Cleat

BT75SDT Screw drive tension mechanism pro- 15 381 8 203 Stainless 1


vides high tension with minimal effort, Steel Buckle
reducing operator fatigue; Heavy duty Strap Cleat
construction offers a longer service BT75SDT
life; Strapping side entry allows quick
side entry of the strap into tool to
speed installation.

14 www.panduit.com/cable-cleats
THE COMPLETE PANDUIT CABLE CLEAT TOOLS

The battery-operated PBTMT and manually-operated, ratchet-style RT2HT


tools are used to install the locking strap cleats.
Both tools tension the strap through its locking head using a gripping tooth
mechanism and then cut the end flush, eliminating any sharp edges.
A side entry slot allows for easy strap insertion, streamlining installation.
The PBTMT is more suitable for higher volume installations, and the RT2HT
for lower volume.

PBTMT/E

For use with


Stainless Steel
Locking
Strap Cleat

Length Width Std


Pkg.
Part Number Description In. mm In. mm Used With Qty.
PBTMT/E Battery powered installation tool, for use with 10.33 262.4 3.17 80.5 Stainless 1
Pan-Steel® Heavy, Extra-heavy, and Super- Steel
Heavy, Cross Section MLT Style Ties, and Locking
MLTD Double Wrapped Style Ties, 2–12 volt Strap Cleat
lithium-ion batteries and 115 volt, 60 Hz
charger included.
RT2HT Hand Operated Tool for use with Extra-Heavy 7.1 180 4.05 103 Stainless 1 RT2HT
and Super-Heavy Cross Section Pan-Steel® Steel
Type MLT Ties. Locking
Strap Cleat

www.panduit.com/cable-cleats 15
PANDUIT MOUNTING BRACKETS AND CUSHION SLEEVE
Mounting Brackets for Easy Installation and Labor Savings
Install cable cleats after the cable is pulled with Panduit mounting
brackets that affix to the cable tray and cleat after the cable is run in
the tray. For use with
CBH Series Brackets are compatible with the CCSSTR series Stainless
stainless steel trefoil cleats and CCALTR series aluminum and Aluminum
trefoil cleats. Trefoil Cleats

UC Series Brackets work in concert with Panduit’s unique MLT series


locking strap cleats and MS75 series buckle strap cleats.

No loose
pieces eliminates
lost parts.
Capture slot for
swing bolt provides
added security

W
Peened nut
prevents it from
Mounting backing out
bracket completely off
eliminates the the screw
need to drill H
holes through
rungs to Easy-to-use
secure cleats* swing bolt
assembly

CABLE CLEAT BRACKETS


Rung Height Rung Width Part Weight
Part Number In. mm In. mm lb. g
CBH15L50-V6 0.59 15 1.97 50 0.32 145
CBH20L50-V6 0.59 - 0.79 15 - 20 1.97 50 0.32 145
CBH25L50-V6 0.79 - 0.98 20 - 25 1.97 50 0.33 151
CBH30L50-V6 0.98 - 1.18 25 - 30 1.97 50 0.34 154

16 www.panduit.com/cable-cleats
PANDUIT MOUNTING BRACKETS AND CUSHION SLEEVE

1 For use with


MOUNTING BRACKETS
Part Number Std. Pkg. Qty. Stainless Steel Buckle Strap Cleat
UCSQ1-VC 5
UCRND1-VC 5
UCIB1-VC 5 For use with
UCTH1-VC 5
Stainless Steel Locking Strap Cleat
UCFG1-V316 5
I-Beam Mounting Bracket*
UCSQ1-V316 5
UCRND1-V316 5
2 UCIB1-V316 5
Available
UCTH1-V316 5
in 100 ft.
*Available in 316L stainless steel (30.5 m) rolls
and galvanized steel.
TPE low-smoke,
CUSHION SLEEVE halogen-free, and
flame-resistant
Length Width
Top Hat Mounting Bracket*
Part Number In. mm In. mm Std Pkg. Qty.

PCSLSH-B-CR 100 30.5 1.05 26.8 1


3 Pkg. –CR = 100 ft. (30.5 m) reel.

INDIVIDUAL CUSHION SLEEVES


Flat/Multicore Cable Trefoil Cable Quad Cable
Diameter Range Diameter Range Diameter Range Length Width Thickness
Part Number In. mm In. mm In. mm In. mm In. mm In. mm Std. Pkg. Qty.
CSB42-150-230-Q 1.38 – 2.75 35 – 70 0.71 – 1.26 18 – 32 0.63 – 1.14 16 – 29 10.80 274
Round Type Mounting Bracket* CSB42-230-330-Q 2.75 – 3.94 70 – 100 1.26 – 1.97 32 – 50 1.14 – 1.73 29 – 44 14.80 376 2.62 66.70 0.10 2.50 25
CSB42-330-430-Q 3.94 – 5.12 100 – 130 1.97 – 2.75 50 – 70 1.73 – 2.28 44 – 58 18.80 478

4
CUSHION SLEEVE REELS
Length Width Thickness
Part Number Material Ft. m In. mm In. mm Std. Pkg. Qty.
BEST SELLER
PCSLSH-B-CR TPE Low Smoke, Halogen Free 1.05 26.8 0.08 2.2
BEST SELLER 100 30.5 1
PCSSH-B-CR Neoprene 0.91 23.1 0.12 3.1

Strut Mounting Bracket*


www.panduit.com/cable-cleats 17
ALUMINUM TREFOIL CLEAT
The Aluminum Trefoil Cable Cleat is ideal for medium-high short
circuit faults in less corrosive environments. It is available in multiple
sizes with cable range-taking capability and is suitable for trefoil cable
arrangements.
The cleat can be installed after running cable via a unique in the H
industry mounting bracket or before running cable through it by
installing direct to the cable tray rung via a fixing hole and M8 bolt.
Insulating spacers and washers are available to protect against
galvanic corrosion between dissimilar cable tray rung and cable
cleat materials.
W D
Nylon insert lock
nut for vibration
dampening

Rounded edges for


cable protection

Hinged for cable


Installation range-taking
before or after
cable is run
via fixing bolt
or mounting
bracket

18 www.panduit.com/cable-cleats
Aluminum Trefoil Cleat TREFOIL CLEAT
Cable Diameter Range H W D Weight
Part Number In. mm In. mm In. mm In. mm Lb. g Mounting Holes
CCALTR2326-X 0.91 - 1.02 23 - 26 3.92 100 3.98 101 2.17 55 0.81 370 1 x M8
CCALTR2528-X 0.98 - 1.10 25 - 28 4.06 103 4.15 105 2.17 55 0.85 385 1 x M8
CCALTR2730-X 1.06 - 1.18 27 - 30 4.19 107 3.86 98 2.17 55 0.85 388 1 x M8
CCALTR2932-X 1.14 - 1.26 29 - 32 4.33 110 3.87 98 2.17 55 0.87 397 1 x M8
CCALTR3135-X 1.22 - 1.38 31 - 35 4.55 116 3.96 101 2.17 55 0.92 418 1 x M8
CCALTR3438-X 1.34 - 1.50 34 - 38 4.77 121 4.18 106 2.17 55 0.93 424 1 x M8
CCALTR3741-X 1.46 - 1.61 37 - 41 4.99 127 4.41 112 2.17 55 0.98 448 1 x M8
CCALTR4044-X 1.57 - 1.73 40 - 44 5.24 133 4.63 118 2.17 55 1.05 477 1 x M8
CCALTR4347-X 1.69 - 1.85 43 - 47 5.52 140 4.85 123 2.17 55 1.14 516 1 x M8
CCALTR4651-X 1.81 - 2.01 46 - 51 5.83 148 5.05 128 2.17 55 1.23 558 1 x M8
CCALTR5056-X 1.97 - 2.20 50 - 56 6.20 158 5.50 140 2.17 55 1.32 602 1 x M8
CCALTR5561-X 2.17 - 2.40 55 - 61 6.57 167 5.72 145 2.17 55 1.42 647 1 x M8
CCALTR6067-X 2.36 - 2.64 60 - 67 7.01 178 6.15 156 2.17 55 1.55 706 1 x M8
CCALTR6675-X 2.60 - 2.95 66 - 75 7.93 193 6.72 171 2.17 55 1.73 787 1 x M8

Short Circuit Testing Summary1


Trefoil Formation Trefoil Formation Trefoil Formation Trefoil Formation
38 mm Cable Diameter 38 mm Cable Diameter 35 mm Cable Diameter 38 mm Cable Diameter
One Short Circuit Event Two Short Circuit Events One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
114 kA 109 kA 94.6 kA 94.6 kA
3921 lbs force (17.4 kN) 3585 lbs force (15.9 kN) 5401 lbs force (24.0 kN) 5401 lbs force (24.0 kN)
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services (IEEE, IEC, UL, and ANSI) for electric
1

power equipment.

www.panduit.com/cable-cleats 19
ALUMINUM TWO-HOLE CLEAT

The Aluminum Two-Hole Cleat is ideal for medium-high short circuit


faults in less corrosive environments. It is available in multiple sizes
with cable range-taking capability and is suitable for single
conductor cables. P
The cleat is installed after running cable by installing direct to the cable
tray rung via fixing holes and two M10 bolts. Insulating spacers and
washers are available to protect against galvanic corrosion in case of
dissimilar cable tray rung and cable cleat materials. H

W D
Tightening
bolts can be
installed from
top or bottom

Rounded
edges
for cable
protection

Ridges
to hold
cable in
place

20 www.panduit.com/cable-cleats
Aluminum Two-Hole Cleat TWO-HOLE CLEAT
Cable Diameter Range H W D F Weight
Part Number In. mm In. mm In. mm In. mm In. mm Lb. g Mounting Holes
CCAL2H3846-X 1.50 - 1.81 38 - 46 2.01 51 3.98 101 1.64 42 2.91 74 0.50 226 2 x M10
CCAL2H4658-X 1.81 - 2.28 46 - 58 2.36 60 4.52 115 1.69 43 3.39 86 0.64 291 2 x M10
CCAL2H5870-X 2.28 - 2.76 58 - 70 2.87 73 5.18 132 1.75 45 3.96 101 0.89 404 2 x M10
CCAL2H7083-X 2.76 - 3.27 70 - 83 3.39 86 5.71 145 1.81 46 4.47 114 1.09 496 2 x M10
CCAL2H8397-X 3.27 - 3.82 83 - 97 3.94 100 6.36 162 1.87 47 5.06 129 1.39 630 2 x M10
CCAL2H97109-X 3.82 - 4.29 97 - 109 4.53 115 6.87 175 1.93 49 5.55 141 1.66 754 2 x M10
CCAL2H109120-X 4.29 - 4.72 109 - 120 5.04 128 7.33 186 1.98 50 5.99 152 1.92 873 2 x M10

Short Circuit Testing Summary1


Flat Formation Flat Formation
105 mm Cable Spacing 105 mm Cable Spacing
One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
131 kA 131 kA
3748 lbs force (16.7 kN) 3748 lbs force (16.7 kN)
1
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services
(IEEE, IEC, UL, and ANSI) for electric power equipment.

www.panduit.com/cable-cleats 21
ALUMINUM ONE-HOLE CLEAT
S

The Aluminum One-Hole Cleat is ideal for lower to medium short


circuit faults in less corrosive environments. It is available in multiple
sizes with cable range-taking capability and is suitable for single
conductor cables.
The cleat is installed after running cable by installing direct to the
E
cable tray rung via a fixing hole and M10 bolt. Insulating spacers and
washers are available to protect against galvanic corrosion in case of
dissimilar cable tray rung and cable cleat materials.
H

Tightening
W D
bolt can be
installed from
top or bottom

Rounded
edges
for cable Ridges
protection to hold
cable in
place

Interlock feature
prevents rotation
between top and
bottom pieces

22 www.panduit.com/cable-cleats
Aluminum One-Hole Cleat ONE-HOLE CLEAT
Cable Diameter
Range H W D E S Weight
Mounting
Part Number In. mm In. mm In. mm In. mm In. mm In. mm Lb. g Holes
CCAL1H1013-X 0.39 - 0.51 10 - 13 0.91 23 1.59 40 1.60 41 0.48 12 0.77 20 0.11 50 1 x M10
CCAL1H1316-X 0.51 - 0.63 13 - 16 1.02 26 1.72 44 1.61 41 0.48 12 0.83 21 0.13 59 1 x M10
CCAL1H1619-X 0.63 - 0.75 16 - 19 1.14 29 1.88 48 1.61 41 0.50 13 0.91 23 0.15 68 1 x M10
CCAL1H1923-X 0.75 - 0.91 19 - 23 1.26 32 2.04 52 1.61 41 0.50 13 0.99 25 0.17 77 1 x M10
CCAL1H2327-X 0.91 - 1.06 23 - 27 1.42 36 2.28 58 1.62 41 0.51 13 1.07 27 0.20 89 1 x M10
CCAL1H2732-X 1.06 - 1.26 27 - 32 1.57 40 2.44 62 1.63 41 0.53 14 1.19 30 0.24 107 1 x M10
CCAL1H3238-X 1.26 - 1.50 32 - 38 1.77 45 2.68 68 1.63 42 0.53 14 1.30 33 0.27 125 1 x M10
CCAL1H3846-X 1.50 - 1.81 38 - 46 2.01 51 2.98 76 1.64 42 0.54 14 1.45 37 0.33 149 1 x M10
CCAL1H4651-X 1.81 - 2.01 46 - 51 2.36 60 3.25 83 1.65 42 0.56 14 1.58 40 0.40 181 1 x M10
CCAL1H5157-X 2.01 - 2.24 51 - 57 2.56 65 3.49 89 1.66 42 0.57 14 1.70 43 0.44 202 1 x M10

Short Circuit Testing Summary1


Flat Formation Flat Formation
105 mm Cable Spacing 105 mm Cable Spacing
One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
93.4 kA 93.4 kA
1904 lbs force (8.47 kN) 1904 lbs force (8.47 kN)
1
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services
(IEEE, IEC, UL, and ANSI) for electric power equipment.

www.panduit.com/cable-cleats 23
POLYMER TREFOIL CLEAT

The Polymer Trefoil Cleat is ideal for medium-high short circuit faults
in less harsh environments. It is available in multiple sizes with cable
range-taking capability and is suitable for trefoil cable arrangements. S
The cleat is installed after running cable by installing direct to the cable
tray rung via a fixing hole and M10 bolt.

D W

Dual bolt
installation

Rounded
edges
for cable
protection

Ridges
to hold
cable
in place

Corrosion
resistant body

24 www.panduit.com/cable-cleats
Polymer Trefoil Cleat TREFOIL CLEAT
Cable Diameter
Range H W D S Weight
Part
Number In. mm In. mm In. mm In. mm In. mm Lb. g Mounting Holes
CCPLTR2228-X 0.87 - 1.10 22 - 28 3.46 88 5.20 132 3.07 78 3.62 92 1.29 585 1 X M10, 2 X M10
CCPLTR2633-X 1.02 - 1.30 26 - 33 3.86 98 5.59 142 3.07 78 4.02 102 1.39 630 1 X M10, 2 X M10
CCPLTR3139-X 1.22 - 1.54 31 - 39 4.13 105 6.06 154 3.07 78 4.49 114 1.51 685 1 X M10, 2 X M10
CCPLTR3745-X 1.46 - 1.77 37 - 45 4.61 117 6.54 166 3.07 78 4.96 126 1.64 745 1 X M10, 2 X M10
CCPLTR4352-X 1.69 - 2.05 43 - 52 5.04 128 7.09 180 3.07 78 5.51 140 1.80 815 1 X M10, 2 X M10
CCPLTR5060-X 1.97 - 2.36 50 - 60 5.55 141 7.76 197 3.07 78 6.14 156 1.97 895 1 X M10, 2 X M10

Short Circuit Testing Summary1


Trefoil Formation Trefoil Formation Flat Formation Flat Formation
38 mm Cable Diameter 38 mm Cable Diameter 38 mm Cable Diameter 38 mm Cable Diameter
One Short Circuit Event Two Short Circuit Events One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 300 mm spacing (Clause 6.4.5) 300 mm spacing (Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
136 kA 130 kA 109 kA 109 kA
5581 lbs force (24.8 kN) 5099 lbs force (22.7 kN) 7170 lbs force (31.0 kN) 7170 lbs force (31.0 kN)
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services (IEEE, IEC, UL, and ANSI) for electric
1

power equipment.

www.panduit.com/cable-cleats 25
POLYMER TWO-HOLE CLEAT

The Polymer Two-Hole Cleat is ideal for lower to medium short circuit
faults in less harsh environments. It is available in multiple sizes with
cable range-taking capability and is suitable for single conductor P
cable arrangements.
The cleat is installed after running cable by installing direct to the cable
tray rung via fixing holes and two M10 bolts.
H

W D
Dual bolt
installation

Rounded
edges
for cable
protection

Ridges
to hold
cable in
place

Corrosion
resistant body

26 www.panduit.com/cable-cleats
Polymer Two-Hole Cleat TWO-HOLE CLEAT

Cable Diameter Range H W D P Weight


Part Mounting
Number In. mm In. mm In. mm In. mm In. mm Lb. g Holes
CCPL2H3846-X 1.50 - 1.81 38 - 46 2.20 56 4.07 103 1.73 44 2.92 74 0.31 143 2 x M10
CCPL2H4658-X 1.81 - 2.28 46 - 58 2.56 65 4.53 115 1.74 44 3.37 86 0.38 175 2 x M10
CCPL2H5870-X 2.28 - 2.76 58 - 70 3.07 78 5.04 128 1.76 45 3.85 98 0.48 220 2 x M10
CCPL2H7083-X 2.76 - 3.27 70 - 83 3.19 81 5.56 141 1.85 47 4.36 111 0.60 273 2 x M10
CCPL2H8397-X 3.27 - 3.82 83 - 97 4.13 105 6.13 156 1.95 50 4.91 125 0.74 335 2 x M10
CCPL2H97109-X 3.82 - 4.29 97 - 109 4.72 120 6.64 169 2.06 50 5.40 137 0.88 402 2 x M10
CCPL2H109120-X 4.29 - 4.72 109 - 120 5.24 133 7.10 180 2.09 53 5.84 148 1.01 460 2 x M10
CCPL2H120135-X 4.72 - 5.31 120 - 135 5.71 145 7.69 195 2.17 55 6.42 163 1.17 533 2 x M10
CCPL2H135150-X 5.31 - 5.91 135 - 150 6.34 161 8.31 211 2.19 56 7.01 178 1.35 615 2 x M10
CCPL2H150165-X 5.91 - 6.50 150 - 165 6.97 177 8.92 227 2.29 58 7.61 193 1.57 712 2 x M10

Short Circuit Testing Summary1


Flat Formation Flat Formation
105 mm Cable Spacing 105 mm Cable Spacing
One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
85.4 kA 85.4 kA
1593 lbs force (7.09 kN) 1593 lbs force (7.09 kN)
1
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services
(IEEE, IEC, UL, and ANSI) for electric power equipment.

www.panduit.com/cable-cleats 27
POLYMER ONE-HOLE CLEAT
S

The Polymer One-Hole Cleat is ideal for lower to medium short circuit
faults in less harsh environments. It is available in multiple sizes with
cable range-taking capability and is suitable for single conductor cable
arrangements.
E
The cleat is installed after running cable by installing direct to the cable
tray rung via a fixing hole and M10 bolt.

Single bolt W D
installation

Interlock feature
prevents rotation Rounded
between top edges
and bottom for cable
pieces protection

Ridges
to hold
cable in
place
Corrosion
resistant
body

28 www.panduit.com/cable-cleats
Polymer One-Hole Cleat ONE-HOLE CLEAT
Cable Diameter
Range H W D E S Weight
Part Mounting
Number In. mm In. mm In. mm In. mm In. mm In. mm Lb. g Holes
CCPL1H1013-X 0.39 - 0.51 10 - 13 1.10 28 1.74 44 1.69 43 0.56 14 0.81 21 0.08 38 1 x M10
CCPL1H1316-X 0.51 - 0.63 13 - 16 1.22 31 1.87 48 1.69 43 0.56 14 0.87 22 0.10 44 1 x M10
CCPL1H1619-X 0.63 - 0.75 16 - 19 1.34 34 2.00 51 1.70 43 0.56 14 0.94 24 0.11 49 1 x M10
CCPL1H1923-X 0.75 - 0.91 19 - 23 1.46 37 2.15 55 1.70 43 0.56 14 1.01 26 0.12 56 1 x M10
CCPL1H2327-X 0.91 - 1.06 23 - 27 1.61 41 2.32 59 1.71 43 0.56 14 1.09 28 0.14 63 1 x M10
CCPL1H2732-X 1.06 - 1.26 27 - 32 1.77 45 2.52 64 1.71 44 0.57 14 1.19 30 0.16 72 1 x M10
CCPL1H3238-X 1.26 - 1.50 32 - 38 1.97 50 2.75 70 1.72 44 0.57 15 1.31 33 0.18 82 1 x M10
CCPL1H3846-X 1.50 - 1.81 38 - 46 2.28 58 3.06 78 1.73 44 0.57 15 1.46 37 0.21 96 1 x M10
CCPL1H4651-X 1.81 - 2.01 46 - 51 2.56 65 3.29 84 1.74 44 0.58 15 1.57 40 0.25 114 1 x M10
CCPL1H5157-X 2.01 - 2.24 51 - 57 2.76 70 3.53 90 1.75 44 0.58 15 1.69 43 0.28 125 1 x M10

Short Circuit Testing Summary1


Flat Formation Flat Formation
105 mm Cable Spacing 105 mm Cable Spacing
One Short Circuit Event Two Short Circuit Events
(Clause 6.4.4) 600 mm spacing (Clause 6.4.5) 600 mm spacing
69.5 kA 69.5 kA
1055 lbs force (4.69 kN) 1055 lbs force (4.69 kN)
1
Test compliance to IEC 61914 utilizing KEMA facility; Independent, ISO 17025 accredited testing, inspection, and certification services
(IEEE, IEC, UL, and ANSI) for electric power equipment.

www.panduit.com/cable-cleats 29
PANDUIT SOLUTIONS FOR ELECTRICAL AND NETWORKING INSTALLATIONS

From Breaking Ground to Routine Maintenance and Repair, Panduit Products Impact Your Entire Project Lifecycle
Partner with a company committed to meeting the daily challenges you face. We offer a full solution of over 30,000 readily available parts
— from cable ties to power connectors, terminals to identification — Panduit products are engineered for all aspects of designing, installing
and maintaining infrastructures within heavy-duty industrial environments.
• Productivity Reduce costs and meet deadlines with products and tools engineered to improve efficiency
• Reliability Ensure performance and design consistency of products that are vital to the success of the job
• Safety Protect personnel, equipment and infrastructure

START EVERY PROJECT OFF RIGHT

StructuredGround™ Direct
Burial Compression Crimp Tools
Grounding System

Power Connectors Abrasion Protection

30 www.panduit.com/cable-cleats
PANDUIT SOLUTIONS FOR ELECTRICAL AND NETWORKING INSTALLATIONS

Stainless Steel Cable Ties Labeling and Identification

Lockout/Tagout and
Cable Ties
Safety Systems

VeriSafe™ Absence of Voltage NetKey ® Network


Tester - AVT Components

Cable Management
Permanent Identification Accessories

www.panduit.com/cable-cleats 31
Romania
China
Netherlands
Chicago
Georgia Japan

UAE
Mexico

Costa Rica
Singapore

Chile

Australia
Primary Offices
Manufacturing Facilities

Panduit Corp.
World Headquarters
Tinley Park, IL 60487

Global Capabilities cs@panduit.com


US and Canada: 800.777.3300
Europe, Middle East, and Africa:
Global Expertise and Support 44.20.8601.7200
Global distribution, manufacturing, sales and technical Latin America: 52.33.3777.6000
support teams make Panduit solutions readily accessible, Asia Pacific: 65.6305.7575
allowing the right products to be delivered when and
where they are needed.
Let's Connect
www.panduit.com/contact-us
Worldwide Certifications
Panduit solutions hold a variety of the most common
heavy industry certifications and approvals worldwide. ©2024 Panduit Corp. ALL RIGHTS RESERVED. FRCB37-SA-ENG 4/2024

You might also like