0% found this document useful (0 votes)
40 views6 pages

Hes50 18 326TC

This document provides specifications for a 37 kW AC induction motor, including performance data, general specifications, and accessories. The motor is designed for continuous duty with a service factor of 1.15 and features a squirrel cage rotor, IP55 enclosure, and various voltage options. Additional details include efficiency ratings, torque, and compliance with NEMA and CSA standards.

Uploaded by

Sean Kim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views6 pages

Hes50 18 326TC

This document provides specifications for a 37 kW AC induction motor, including performance data, general specifications, and accessories. The motor is designed for continuous duty with a service factor of 1.15 and features a squirrel cage rotor, IP55 enclosure, and various voltage options. Additional details include efficiency ratings, torque, and compliance with NEMA and CSA standards.

Uploaded by

Sean Kim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Customer :

Project Name :
Project No. :
Revision No. :

SPECIFICATION
for
INDUCTION MOTOR

0 For Bidding

No. DATE DESCRIPTION PREPARED BY CHECKED BY APPROVED BY

www.hd-hyundaielectric.com
AC INDUCTION MOTOR DATA SHEET
Catalog No. HES50-18-326TC Item No. Rev. No. [ ]
Project Name Project No. Quantity sets
GENERAL SPECIFICATION PERFORMANCE DATA
Frame Size 326TC Rated Output 37 kW 0 50 HP
Type PJP Number of Poles 4
Enclosure(Protection) Totally Enclosed / IP55 Rotor Type Squirrel Cage
Method of Cooling IC411(FC) Starting Method* D.O.L
Rated Frequency 60 Hz Rated Voltage 575 V 460 V 230 V
Number of Phases 3 Current Full Load 46.8 A 58.5 A 117.0 A
Insulation Class F Locked-rotor** 830 % 830 % 830 %
Temp. Rise at full load (by resistance method) Efficiency
at 1.0 S.F 80 deg. C 50% Load 91.5 % 0
Motor Location Indoor Outdoor 75% Load 93.5 % 0
Altitude Less than 1,000 meter 100% Load 94.5 %
Relative Humidity Less than 80 % Power Factor(p.u)
Ambient Temp. 40 deg. C (Max.) 50% Load 0.690 0
Duty Type Continuous ( S1 ) 75% Load 0.790 0
Service Factor 1.15 100% Load 0.840 0
Mounting B35 Speed at Full Load 1780 r.p.m 0
Type Anti-Friction Torque
Bearing DE/N-DE 6313ZC3 / 6212ZC3 Full Load 146.4 lb.ft 0
Lubricant Grease(Polyrex-EM) Locked-rotor** 170 % 0
External Thrust Not applicable Breakdown** 220 % 0
Coupling Method Direct V-belt Moment of Inertia (J)
Shaft Extension Single Load(Max.) 278.234 lb.ft2
Terminal Main Cast Iron Motor 8.307 lb.ft2
Box Aux. No Sound Pressure Level (No-load & mean value at 1m from motor)
Location Refer to Outline Drawing 74 dB(A)
Application Vibration 3.8 mm/sec (peak)
Area classification Hazardous Permissible number of Cold 3 times
Type of Ex-Protection Class I&II, Division 2 consecutive starts Hot 2 times
Applicable Standard NEMA MG1, CSA C390 Paint Munsell No. 4.0PB5.4/5.5(VL-451)
ACCESSORIES SUBMITTAL DRAWING
Outline Dimension Drawing \ Motor Weight(Approx.)
B35 LM-T2326C4PLV23 580 lb.

REMARK
1. Premium efficiency according to NEMA MG1
2. Inverter Duty @ 1.0 Service Factor & F Temperature rise
-. 10:1 VT (20:1 VT at 50% load)
-. 10:1 CT
-. CHP up to 1.5 times base speed, NEMA MG1 Part31
3. CSA Certification
SPARE PARTS -. Class I, Division 2, Group A, B, C & D
-. Class II, Division 2 Group E, F & G (Group E : up to 320Fr.)
4. Service Factor 1.15 and Temperature rise B are applicable
under the condition of sine wave power.
5. Service Factor 1.25 is applicable to motors of 100HP or less
with temperature rise F & Non-Hazardous.

Date DSND CHKD CHKD APPD


2024-07-13 S.H. Lee I.K. Kim R.G. Kim S.W. Kim
[Note] Others not mentioned in this data sheet shall be in accordance with maker standard.
Above technical data are only design values and shall be guaranteed with tolerance of applicable standard.
Inspection and performance test shall be done according to maker standard, if not mentioned.
* In case of Inverter-Fed Motor, performance data is based on sine wave tests. It may be different from test data of Inverter combined motor.
** Data is based on rated voltage & frequency and is expressed as a percentage of full-load value.
4.72

50HP 4P 230/460V HES50-18-326TC


HLS326PR23 F 117/58.5
HLS CONT J 40°C 60Hz
326TC TEFC 1.15 1780 94.5%

2.36
6313ZC3 93.5%
6212ZC3 B Torque
50Hz 40HP 380V 63.8A 1480rpm S.F.: 1.0 Eff.: 92.3% Code: J
50Hz 40HP 400/415V 62.2/61.4A 1480/1480rpm S.F.: 1.0 Eff.: 92.3/92.3% Code: K/L
LATER PJP

- - 580 lb

CSA Class I, Division2 Severe Duty (HES, 254-326)

4M-136024
NP-HES50-18-326TC 0
CURVE NO.
PERFORMANCE CURVE
PC-HES50-18-326TC
Type : PJP 37kW 50HP 4P 60 Hz
Full Load Torque : 146.4 lb.ft Speed at Full Load : 1780 RPM
Load moment of Inertia (J) : 278.234 lb.ft2 Rated Voltage 575V 460V 230V
Motor moment of Inertia (J) : 8.307 lb.ft2 Full Load Current 46.8A 58.5A 117.0A

SPEED VS TORQUE & CURRENT CURVE

250 900
Current at rated voltage
800

200
700

600

CURRENT IN %
Torque at rated voltage
TORQUE IN %

150
500

400
100
300

200
50

100

0 0
0 10 20 30 40 50 60 70 80 90 100
SPEED IN %

OUTPUT VS EFF., P.F & CURRENT CURVE

100.0 200

180
90.0 EFF.
160

140
80.0
EFF. & P.F IN %

CURRENT IN %

120

70.0 P.F 100

80
Current
60.0
60

40
50.0
20

40.0 0
0 25 50 75 100 125
LOAD IN %

RM-P251-133 A4(210mm x 297mm)


Ø

Ø
Cls. I&II, Div. 2
IEEE 841

You might also like