Model VT 400
Revere
Weight Controller/Indicator
FEATURES
• Inventory and batching control terminal
• High sample rate, up to 70 samples per second
• Up to two serial ports with printing and networking
(one standard)
• Analog output (optional)
• Two opto-isolated weight setpoints
• Large 6 digit LED display
• Alibi (Flash) memory for last 10,000 transactions
• OIML R-76 approved to 10000d
• Panel mount IP40 enclosure
• IP54 front panel cover (optional)
• Input power 24VDC
APPLICATIONS
DESCRIPTION
• Process weighing
VT 400 Weight Controllers provide weighing and control
functions for industrial process systems. • Inventory control
Two opto-isolated control outputs, a choice of up to two OPTIONS
serial interfaces (RS-232 and RS-485) and an analog output
(optional) allow full communication with higher level PCs or • Analog output
PLCs. Up to 30 units can be interconnected through the • RS-485 port
RS-485 network. • Second RS-232 port
The standard VT 400 panel mount enclosure is rated IP40.
However, it can be upgraded with an IP54 front panel cover
(optional).
CONFIGURATION
www.vishaypgloadcells.com Technical contact in Americas: lc.usa@vishaypg.com, Europe: lc.eur@vishaypg.com, Document Number: 11639
324 China: lc.china@vishaypg.com, Taiwan: lc.roc@vishaypg.com Revision: 14-Jun-10
Model VT 400
Weight Controller/Indicator Revere
SPECIFICATIONS
PERFORMANCE ELECTRICAL
Resolution: selectable up to 990,000 dd Voltage: 24VDC
Conversion Speed: 3 - 70 samples per second (selectable) Current: 500mA
Sensitivity: 0.4µV/Vsi for approved scales, ISOLATED ANALOG OUTPUT (OPTIONAL)
0.1µV/Vsi for non-approved scales. Resolution: 16 bit DAC
Full Scale Range: -0.25 to 1.75mV/V [-1.25mV to 8.75mV] or Voltage Output: 0.02-10V
-0.25 to 3.75mV/V [-1.25mV to 18.75mV] Current: 0-20mA or 4-20mA
Linearity: 0.002% of full scale Linearity: 0.01% (or better) of full scale
Long Term Stability: 0.005% of full scale per year Thermal Stability: 50ppm/°C typical
Excitation: +5V alternating polarity or +5VDC INPUTS & OUTPUTS
(selectable), with sense (6 wires) (x1) Logic Input: 9-24VDC, negative common,
Number of Cells: Up to 10, 350 ohm load cells opto-isolated to 2.5KV.
Filter: FIR automatically adjusted to (x2) Logic Output: 24VDC±10%, positive common, max
conversion speed, rolling average. current 100mA, opto-isolated to 2.5KV,
Offset Drift: < 2ppm/°C programmable as weight setpoints
Span Drift: < 2ppm/°C SERIAL COMMUNICATION
A/D Converter Type: Sigma-Delta, ratiometric Serial Output #1: RS-232, non-programmable
Count By: x1, x2, x5, x10, x50 Baud Rate: 2400 baud, full duplex
Decimal Point: between any digits of the weight display Applications: continuous, print (on demand), alibi print
Calibration Methods: dead load and span, or data sheets Serial Output #2: RS-232 or RS-485 setup programmable
calibration, via the mV/V output Baud Rate: 2400 - 57800 baud, half duplex
values of the load cell. Applications: EDP and master-slave protocols,
Weighing Functions: automatic zero tracking, motion continuous output, remote printer,
detection, auto-zero on power-up, weight output
zero tare, multiple test functions.
ENCLOSURE
Memory Allocation: calibration data EEPROM (32kb), Flash
Heavy duty plastic enclosure:
tally-roll (Alibi) memory capable of Dimensions: 144x72x132mm LxHxD
10,000 weight registrations (64kb)
[5.7x2.8x5in. LxHxD]
ENVIRONMENTAL Mounting: panel mount
Operating Temp: -10°C to +40°C [14°F to 104°F] Protection: IP40 standard,
Storage Temp: -10°C to +70°C [-4°F to 158°F] optional front panel cover - IP54
Relative Humidity: 40-90% RH, non-condensing Wiring Connections: mini D-type connectors
DISPLAY AND KEYBOARD APPROVALS (ACCURACY CLASS III/IIIL)
Display: 6 digit, 7 segment, LED OIML R-76: 10000d single or dual interval
Digital Height: 14mm [0.55in.] EU-type approval no. DK0199.62
Status Enunciators: no motion, zero, tare in use, net, setpoint
in operation
Weight Digits: 4, 5 or 6 (setup selectable) Transducers is continually seeking to improve product quality and
Keyboard: 6 membrane keys, with tactile feedback performance. Specifications may change accordingly.
Document Number: 11639 Technical contact in Americas: lc.usa@vishaypg.com, Europe: lc.eur@vishaypg.com, www.vishaypgloadcells.com
Revision: 14-Jun-10 China: lc.china@vishaypg.com, Taiwan: lc.roc@vishaypg.com 325
Legal Disclaimer Notice
Vishay Precision Group
Disclaimer
ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, “Vishay Precision Group”), disclaim any and all liability for any errors, inaccuracies or
incompleteness contained herein or in any other disclosure relating to any product.
The product specifications do not expand or otherwise modify Vishay Precision Group’s terms and
conditions of purchase, including but not limited to, the warranty expressed therein.
Vishay Precision Group makes no warranty, representation or guarantee other than as set forth in the terms
and conditions of purchase. To the maximum extent permitted by applicable law, Vishay Precision
Group disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and
all liability, including without limitation special, consequential or incidental damages, and (iii) any and
all implied warranties, including warranties of fitness for particular purpose, non-infringement and
merchantability.
Information provided in datasheets and/or specifications may vary from actual results in different
applications and performance may vary over time. Statements regarding the suitability of products for
certain types of applications are based on Vishay Precision Group’s knowledge of typical requirements that
are often placed on Vishay Precision Group products. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular
application.
No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or
by any conduct of Vishay Precision Group.
The products shown herein are not designed for use in life-saving or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay Precision Group products not expressly
indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay
Precision Group for any damages arising or resulting from such use or sale. Please contact authorized
Vishay Precision Group personnel to obtain written terms and conditions regarding products designed for
such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document No.: 63999 www.vishaypg.com
Revision: 27-Apr-2011 1