Vega LCD Serial

The document provides technical specifications and features for the LCD565-A and EASY565-A serial displays, including power supply requirements, dimensions, and mounting options. It details the functionality for collecting car calls and managing alarms, as well as programming instructions and diagnostics. Additionally, it includes information on expansion capabilities and various fixing kit codes.

Uploaded by

Othmane Boujanah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views12 pages

Vega LCD Serial

The document provides technical specifications and features for the LCD565-A and EASY565-A serial displays, including power supply requirements, dimensions, and mounting options. It details the functionality for collecting car calls and managing alarms, as well as programming instructions and diagnostics. Additionally, it includes information on expansion capabilities and various fixing kit codes.

Uploaded by

Othmane Boujanah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

LCD565-A, EASY565-A

Rev. 3 Hardware: Rev.4.2 Firmware: v1.2

LCD565-A
Rear
Front

✔ Serial display with overload, alarm active and alarm received;


✔ Collecting up to 17 car calls, PAP and PCP (up to 24 stops);
✔ Input to disable calls in the cabin.

LCD569-A
Rear
Front

✔ Serial display with overload, alarm active and alarm received;


✔ Collecting up to 17 car calls, PAP and PCP (up to 24 stops);
✔ Input to disable calls in the cabin.

EASY565-A: Board for car calls (without display)


✔ Collecting up to 17 car calls, PAP and PCP (up to 24 stops);
✔ Input to disable calls in the cabin.

FIXING KIT CODES

CODE DESCRIZIONE
VG003 Chrome frame kit
VG004 Gold frame kit
VG007 Gunmetal frame kit
VG008 Satin nickel frame kit
KIT FL174 X79-1.2 Kit flush mounting (Thk. 1,2 mm)
KIT FL174 X79-2 Kit fissaggio a filo (Thk. 2 mm)
1 TECHNICAL DATA
Power supply 12÷24 vdc ±10%
Current absorption ▫12 v dc: max 60 mA ▫ 24 v dc: max 30 mA

Visible area 123x57 mm


Sheet thickness Max. 3mm with frame
1.2 o 2 mm for flush mounting
Temperature working range From -15°c to +50°c
Coding Seriale v.
Life 100% brightness 25 000 hours
Light intensity 350 cd/ m^2

2 PINOUT
POWER/SERIAL COLLECTION CALLS Push button of
programming
DINinternal data
GND Power (-) JP9 JP11 JP13 JP15
KI Internal Clock JP10 JP12 JP14
VIM Power (+)
courtesy VIM

light Diagnostics
leds
GND

VIM
VIM

VIM
GND

GND
GND
GND

L
L

VIM
GN D

GND
VIM

VIM
I

L
VIM

L
L

I
I
I
L
I

LE+
12/24
Vdc
DIP-SWITCH
GND
VIM
JP16 L
I JP
A
EXPANSIONS:
ALARMS
12/24Vdc JPB -LCD_EXC_AMP
AA+
-LCD_EXP_CONNM/F
Alarm active AA-
AR+ -LCD_EXP_CONNM/F.BOX
Alarm received AR- J PC
Inputs for COM
C1
disable the
C2
calls
C1: from I0 to I8
C2: from I0 to I11 C3
NOT Buzzer
GN D
GND

GND
GND
GND

GND

GND

GND
GND
VIM

USED
VIM

VIM

VIM
VIM
VIM

VIM

VIM
VIM
L

L
L
I

L
I

L
I

I
I

I
I
I

Trimmer for
volume of buzzer
JP0 JP1 JP2 JP3 JP4 JP5 JP6 JP7 JP8

COLLECTION CALLS
PINOUT 2 (With KITTI board)
PINOUT 1 CONNECTOR FUNCTION
CONNECTOR FUNCTION JP0 Open door push button (PAP)
JP0-JP14 Calls (example first floor=0, JP1 Close door push button (PCP)
from 0 to 14) JP2-JP15 Calls (example first floor=0,
JP15 Close door push button (PCP) from 0 to 13)
JP16 Open door push button (PAP) JP16 Not used
JPB-1, JPB-2, Calls expansions (example first JPB-1, JPB-2, Calls expansions (example first
JPB-3, JPB-4 floor=0, from 16 to 19) JPB-3, JPB-4 floor=0, from 14 to 17)
JPC-1, JPC-2, Calls expansions (example first JPC-1, JPC-2, Calls expansions (example first
JPC-3, JPC-4 floor=0, from 20 to 23) JPC-3, JPC-4 floor=0, from 18 to 21)
IMPORTANT: SET ALWAYS: DIP-SWITCH 3 ON
Courtesy light : By activating the "LE +" input, the display switches on all the segments, icons and arrows.
1
3 EXPANSIONS
CONNECTION UP TO 24 PUSHBUTTON (AMP):
Diagnostics leds (input)
CODE:
LCD_EXP_AMP

JPB JPB-1 JPB-2 JPB-3 JPB-4


*Mounting with double-sided
adhesive

+ 12 v
+ 12 v

+ 12 v

GND
GND

GND

+ 12 v
GND
L
L

L
I
I

I
JP C JPB-1 JPB-2 JPB-3 JPB-4

JPC-1 JPC-2 JPC-3 JPC-4

+ 12 v
+ 12 v

+ 12 v

GND
GND

GND

+ 12 v
GND
L

L
I

L
I

I
CODE OF CABLE (1 pz.):
CB10.MCM-MCM.0015 15 cm
JPC-1 JPC-2 JPC-3 JPC-4

CONNECTIONS FOR SERVICE SIGNALS: ONLY FOR PINOUT 1!


LCD_EXC_CONNM/F.BOX Diagnostics leds (input)
+V GND I1 O1 I2 O2 I3 O3 I4 O4
CODE:
LCD_EXP_CONNM/F

JP A
I12

I13

I15
I14

- - - -
O12 O13 O14 O15
+ + + + Mounting with double-
sided adhesive

JPB +V GND I1 O1 I2 O2 I3 O3 I4 O4 LCD_EXP_CONNM/F.BOX


I16

I17

I19
I18

JP C O16
-

+
O17
-

+
-
O18
+
O19
-

+V GND I1 O1 I2 O2 I3 O3 I4 O4
I20

I21

I23
I22

*Mounting on DIN rail


CODE OF CABLE (1 pz.):
CB10.MCM-MCM.0300 3m
- - - -
O20 O21 O22 O23
+ + + +

2
4 PROGRAMMING
NOTE: If you have the model EASY565, don’t touch the push button SEL and
ENT!
For the codes with the display, In the display Indicator’s board are available 2 programming buttons called SEL
(SELECT) and ENT (ENTER).
SW1 button is used to choose a menu or change a parameter, while SW2 button allow to confirm the choice.
Press the SW1 button to enter into modality of programming, while wait the timeout of 30 seconds to exit programming
mode without modify any parameter.

restore Programming Normal


DEFAULT
x 5 sec
ENT SEL

STAND-BY Selected shutdown’s time


0=always on;
M1 It allows to choose the time for the
ME
30

1=1 minut; ENT


display’s backlight shutdown (minutes).
99=99 minuts
SEL

SIMULATION Enable/disable the simulation mode


It allows enable/disable the simulation ENT NO= Disable ENT
ME
0

M2 mode. SI= Enable

SEL

SYMBOL
It allows choosing what Select the Choose the Choose the
-4..27

M3 characters to display for


ENT floor ENT right symbol ENT left symbol ENT
ME
Value of default

(SEL) (SEL) (SEL)


each selected floor.

SEL

CALLS Select :
It allows choosing if enable
M4 00=No calls (only display);
01

or disable the collections


calls
01=With calls.
ENT
ME

BEEP AND GONG Select :


It allows set the operation 00 = Beep from control board, gong off;
M5
ME
00

01 = Automatic Beep, gong off; ENT


for the beep of the push
buttons, and the 02 = Beep from control board, gong on;
management of the gong. 03 = Automatic Beep, gong on.

SEL

XX
SHOW FIRMWARE
VERSION

NOTE:
To restore the default values, enter in the menu with SEL button and keep pushed ENT button for at least 5 seconds
The display visualize “ME”.

3
5 DIP-SWITCHES
4 TEST I/O
OFF TEST OFF
ON TEST ON

SERIAL ADDRESS 3 = ON, always!


1 2
OFF OFF Address 0
ON OFF Address 1
OFF ON Address 2
ON ON Address 3

4
6 DIAGNOSTICS LEDS

LED:
DL1 Serial diagnostic;
Slow blinking (1Sec ON, 1 sec. OFF), the display receives the serial signals.
Fast blinking= Serial Wiring incorrect or broken
DL2: the DL2 blinks 1sec ON 1sec OFF when the input C1 it’s closed, for disable the calls, If the
input it’s open the led it’s off.
DL3:rimane sempre acceso. Turns on at activing of an input (I0,I1..).If at least one input is activated
the led remains ON.

TEST I/O
For enable the test mode set:
DIP-SWITCH 4=ON
A segment of the display corresponds to each input.
Active input segment off.
At activation of an input (from I0 to I23) the relative output will be activated (From O0 to O23).

C3/JP16
8 15
9 14
C1

22

DP4

7 65
23

21

20 19 4 3
C2

2
18

16

0
17

DP3

1
10 13
DP1 DP2 DP= DIP SWITCH
11 12

ALL INPUT
OFF

All segments ON

INPUT “0”--> ON

A segment active
5
7 MOUNTING WITH FRAME

CORNICE/FRAME
VETRO DI PROTEZIONE/
PROTECTION GLASS
PIASTRA/
OPERATING PANEL
STAFFA DI BLOCCO/
BLOKING TOOL

DISPLAY

8 DIMENSIONS SCREEN

121
16,1 13,3 16,18

46,5

40,9
56

6
9 CUTOUT

WITH FRAME
R3
,2
5

79
144

FLUSH MOUNTING
134,60

66,99 67,61
9,25
36,85
73,70

SCASSO
36,85

120,2x55,2 R5,6
Ø3,00
9,25

DIMENSIONS : in mm

7
10 DIMENSIONS BOARD

170

160

144

134,60

10
LE

PWR D - C + JP15
JP9 JP10 JP11 JP12 JP13 JP14

JPA
JP16

LCD565-A

73,71
65,80
JPB

96
EASY565-A

115
AA+
AA-
AR+
AR-

LCD500_V4.2

JPC
KEYS

JP0 JP1 JP2 JP3 JP4 JP5 JP6 JP7 JP8

+
BUZ
3
10

Maximum
10 encumbrance

LCD_EXP_CONNM/F LCD_EXP_AMP
71,95 71,95
12,85 12,85
20,50

20,50

1 2 3 4
1 2 3 4
30

JP5 +V GND I1 O1 I2 O2 I3 O3 I4 O4
JP5 +V GND I1 O1 I2 O2 I3 O3 I4 O4
13,80

13,80

56,20 56,20 Ø3
Ø3

LCD_EXP_CONNM/F.BOX
68 21 16 12.6
JP5
JP5

JP5

+V
+V

+V

CONNECTOR
1
1

GND I1
GND I1

GND I1
82,00

O1
O1

O1

2
2

I2
I2

I2

O2
O2

O2

I3
I3

I3

3
3

O3
O3

O3

I4
I4

I4

4
4

O4
O4

O4

DIMENSIONS in: mm

8
11 SYMBOLS

9
10
Vega Srl
Via degli Appennini 11/13
Capparuccia - 63845 Ponzano di Fermo (AP) – Italy
P.Iva 01578140442
Tel. +39 0734. 631941 Interno 1 Fax +39 0734. 636098
Interno assistenza: +39 0734. 275406
www.vegalift.it

11