Sensor Rotuladora C - G
Sensor Rotuladora C - G
Narrow beam Retro ref. Narrow beam Diffused ref. Diffused reflection Narrow beam BGS BGS Transparent model Mark detection
Cable type J3R-(S,H)100(P,N) J2D-(S,H)10(P,N) J2D-(S,H)70(P,N) J2D-(S,H)100(P,N) BGS-3J(S,H)05(P,N) BGS-(S,H)15(P,N) JR-(S,H)Q50(P,N)(-5) J3M-G(S,H)01(P,N)
Photoelectric Sensor Connector type J3R-(S,H)100CP J2D-(S,H)10(CP,CN) J2D-(S,H)70(CP,CN) J2D-(S,H)100(CP,CN) BGS-3J(S,H)05CP BGS-(S,H)15(CP,CN) JR-(S,H)Q50(CP,CN) J3M-G(S,H)01CP
Current consumption 40mA max. 45mA max. 40mA max. 40mA max.
J3R-100J2D-10
Response time 0.2ms max. 0.5ms max. 0.7ms max. 2.5ms max. 0.5ms, 2.5ms max. 0.2ms max.
J3M-G01 J2D-70 Hysteresis 15 max. 5 max. 8 max(on 100mm)
BGS-3J05 J2D- 100 Light Source Red LED IR LED Red LED Green LED
BGS- 15 JR- Q50 Sensitivity adjustment Teaching button
Indicator Output indicator (orange LED), Stable incident indicator (Green LED)
Teaching is complete.
Interruption state
r
Protection
ONE-POINT TEACHING
circuit e
Press the button onto the background(Without objects). Switching point
Release the button after the indicators simultaneously blink 1 time.
PNP output Teaching is complete.
Switching point BGS and Mark-detection and Diffused-reflection
q
BGS and Mark-detection and Diffused-reflection Background
w Adjusted not to detect the background.
Retro-reflection and Transparent model
Main circuit
TWO-POINT TEACHING
First point Switching point
CAUTIONS Press the button until indicators simultaneously blink, 2 times. After
Be careful not to install the sensor at the following locations, as it may otherwise malfunction. blinking 2 times, release it.
Where a lot of dust, vapor, or the like is present. The first point is stored, and then the sensor turns to the input state
Where corrosive gas is produced. for the second point starting simultaneous blinking of the indicators.
Where water, oil or the like flies directly onto the sensor. Switching point is adjusted at the middle
Second point
Where strong vibration or shock is caused to the sensor. between the first and second point.
APress the button (Any duration).
Do not use organic solvent, such as thinner, to remove contaminants from the body case, lid, and lens which are all
of prastics. Using a dry rag, just wipe clean. The indicators simultaneous blink 2 timesComplete.
When a switching regulator is to be used with a power supply, be sure to ground the Frame Ground Terminal. The indicators altermately blink 3 times Teaching error. Restart
Do not use the sensor in a transient state at power on.(about 100ms) from the step
Do not run sensor cable near a high-voltage lines, or power lines or put them together in the same raceway. This
warning should be strictly observed to prevent malfunctions caused by inductive interference. POSITION TEACHING
Place the object onto light spot where the sensor should be ON, and Switching point
! Must not use this item as safety equipment for the purpose of human body protection.
press the button.
Release the button after the indicators simultaneously blink 3 times. Teaching position of the object
TEACHING PROCEDURE (SENSITIVITY ADJUSTMENT) Teaching is complete (No OK sign appears). switching point.
The indicators altermately blink 3 timesŮTeaching error. Restart
1) Depending on the pressing duration of TEACHING BUTTON, the teaching mode can be determined.
from the step
1-time simultaneous 2-time simultaneous 3-time simultaneous 4-time simultaneous
blinking blinking blinking blinking
FGS TEACHING (FGS is a function that detecting range can be adjusted as desired, out of the range is suppressed.)
Max./1-point teaching
Switching point
(Transparent model2poins approx.6sec.) Press the button onto the background(Without objects).
First pulse for 2-point teaching Release the button after the indicators simultaneously blink 4 time.
Teaching is complete. Back
ground
Position teaching The indicators alternately blink 3 times Teaching error. Restart
Light ON ON point in the limit of "a".
from the step
Dark ONOFF point in the limit of "a".
FGS teaching
Note
1.Releasing the button the indicators simultaneously blink 1 time, the switching point is not stored (Exclude the second point teaching)
2.In case of teaching error, the sensor is automatically reset, and function with the previous state.
3.Depending on the object or distance, ONE-POINT/POSITION TEATING is not teached for Mark-detection type.
Sensitivity is set at Max. in default state.
2)REMOTE TEACHING
FGS teaching is only BGS.
Connecting the gray lead to 0V for NPN models (PNP to V), remote teaching can be done without pressing the button.
Transparent model is only 1point teaching.
Same as the button operation, the teaching mode can be determined depending on the pulse duration.
DIMENSIONS
1.2
11
13.85
8.2
14
4.3
8.5 14.9
3.4
14 11
28.5
8.2 29.6
33.6 0.4
3.4 23
¡Specifications and equipment are subject to change
38 ¡without any obligations on the part of manufacture.
15.4
28.5
23
3.4
10
4.5
21.6
1.2
21.6
6.6
4.3
10.2 10 4.5
13.7 21.6
21.6 25.4 OPTEX FA CO.,LTD.
Optical axis A B Optical axis A B Optical axis A B Optical axis A B 607-8085 Kyoto, Yamashina, Takehanadonomaecho 46-1, JAPAN
Narrow beam Retro ref. 12.1 6.6 BGS 11.5 7.7 Narrow beam Retro ref. 9.65 6.6 BGS 9.1 7.7 T e l: 81 0
Narrow beam Diffused ref. 12.1 6 Transparent model 12.1 6.8 Narrow beam Diffused ref. 9.6 6 Transparent model 9.65 6.8 Fax: 810
Diffused reflection 12.1 6.6 Mark detection 12.1 6 Diffused reflection 9.6 6.6 Mark detection 9.65 6 Website : http://www.optex-fa.com
Narrow beam BGS 11.7 6.9 Narrow beam BGS 9.25 6.9 0533791