0% found this document useful (0 votes)
19 views13 pages

RXM4AB1B7

The document provides a detailed datasheet for the RXM4AB1B7 miniature plug-in relay, specifying its electrical and mechanical characteristics, including a continuous output current of 5A and a maximum switching capacity of 1500 VA. It outlines environmental data, packaging information, and compliance with various standards and certifications. Additionally, it highlights Schneider Electric's commitment to sustainability and product recyclability.

Uploaded by

sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views13 pages

RXM4AB1B7

The document provides a detailed datasheet for the RXM4AB1B7 miniature plug-in relay, specifying its electrical and mechanical characteristics, including a continuous output current of 5A and a maximum switching capacity of 1500 VA. It outlines environmental data, packaging information, and compliance with various standards and certifications. Additionally, it highlights Schneider Electric's commitment to sustainability and product recyclability.

Uploaded by

sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Product datasheet

Specifications

Miniature plug-in relay, 6 A, 4 CO,


24 V AC
RXM4AB1B7

Main
Range of product Harmony Electromechanical Relays

Series name Miniature

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Plug-in relay

Device short name RXM

Contacts type and composition 4 C/O

[Uc] control circuit voltage 24 V AC 50/60 Hz

status LED Without

control type Lockable test button

Continuous output current 5A

Complementary
[Uimp] rated impulse withstand 2.5 kV during 1.2/50 µs
voltage
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL

Minimum switching capacity 170 mW at 10 mA, 17 V

Electrical durability 100000 cycles for resistive load

average coil consumption in VA 1.2 at 60 Hz

Average consumption 1.2 VA at 60 Hz

operate time 20 ms

average coil resistance 180 Ohm at 20 °C +/- 15 %

Rated operational voltage limits 19.2...26.4 V AC

[Ui] rated insulation voltage 250 V conforming to IEC


300 V conforming to CSA
300 V conforming to UL

Maximum switching voltage 250 V conforming to IEC

Drop-out voltage threshold >= 0.15 Uc

Load current 6 A at 250 V AC


6 A at 28 V DC

Maximum switching capacity 1500 VA/168 W

CAD overall height 79 mm

CAD overall depth 78.45 mm

4 Feb 2025 1
Mechanical durability 10000000 cycles

Safety reliability data B10d = 100000

Operating rate <= 1200 cycles/hour under load


<= 18000 cycles/hour no-load

Utilisation coefficient 20 %

reset time 20 ms

Dielectric strength 1300 V AC between contacts with micro disconnection


2000 V AC between coil and contact with basic insulation
2000 V AC between poles with basic insulation

Protection category RT I

pollution degree 2

Operating position Any position

Test levels Level A group mounting

Device presentation Complete product

Contacts material AgNi

Shape of pin Flat

Product weight 0.037 kg

Environment
Ambient air temperature for -40…55 °C
operation
IP degree of protection IP40 conforming to IEC 60529

Standards CSA C22.2 No 14


UL 508
IEC 61810-1

Product certifications UL
Lloyd's
CE
CSA
GOST
IECEE CB Scheme

Ambient air temperature for -40…85 °C


storage
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating

Shock resistance 10 gn for in operation


30 gn for not operating

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 2.200 cm

Package 1 Width 2.700 cm

Package 1 Length 4.500 cm

Package 1 Weight 35.000 g

Unit Type of Package 2 BB1

Number of Units in Package 2 10

Package 2 Height 3.000 cm

Package 2 Width 10.200 cm

2 4 Feb 2025
Package 2 Length 12.600 cm

Package 2 Weight 384.000 g

Unit Type of Package 3 S02

Number of Units in Package 3 240

Package 3 Height 15.000 cm

Package 3 Width 30.000 cm

Package 3 Length 40.000 cm

Package 3 Weight 9.675 kg

Contractual warranty
Warranty 18 months

4 Feb 2025 3
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 31

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard Yes

Packaging without single use plastic Yes

China RoHS Regulation China RoHS declaration

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins

Take-back No

4 4 Feb 2025
Product datasheet RXM4AB1B7

Dimensions Drawings

Dimensions

Pin Side View

4 Feb 2025 5
Product datasheet RXM4AB1B7

Connections and Schema

Wiring Diagram

Symbols shown in blue correspond to Nema marking.

6 4 Feb 2025
Product datasheet RXM4AB1B7

Performance Curves

Electrical Durability of Contacts

Durability (inductive load) = durability (resistive load) x reduction coefficient.


Resistive AC load

X Switching capacity (kVA)


Y Durability (Number of operating cycles)
A RXM2AB•••
B RXM3AB•••
C RXM4ΑΒ•••
D RXM4GΒ•••
Reduction coefficient for inductive AC load (depending on power factor cos ϕ)

Y Reduction coefficient (A)


Maximum switching capacity on resistive DC load

X Voltage DC
Y Current DC
A RXM2AB•••

4 Feb 2025 7
Product datasheet RXM4AB1B7

B RXM3AB•••
C RXM4ΑΒ•••
D RXM4GΒ•••
Note : These are typical curves, actual durability depends on load, environment, duty cycle, etc.
For inductive load, to increase relay life cycles, please add a proper load protection circuit (eg: RC protection/Varistor/
free Wheeling diode -DC load only- ).
For low level loads (below 10mA), we recommend to use RXM*GB series with bifurcated contacts relays instead.

8 4 Feb 2025
Product datasheet RXM4AB1B7

AC Coil Voltage and Operating Temperature under continuous duty

X : Operating temperature (°C)


Y : AC coil voltage (UC)

4 Feb 2025 9
Product datasheet RXM4AB1B7

Technical Illustration

Dimensions

10 4 Feb 2025
Product datasheet RXM4AB1B7

Image of product / Alternate images

Alternative

4 Feb 2025 11
Product datasheet RXM4AB1B7

12 4 Feb 2025
Product datasheet RXM4AB1B7

4 Feb 2025 13

You might also like