Medical
Technologies
Experience the
Effectiveness
BIPHASIC DEFIBRILLATOR
POWERED BY
www.bplmedicaltechnologies.com
7 inch Colour TFT Screen
Allows the clear and precise display of multiple
waveforms and defibrillation parameters
Bi-phasic waveform (Current - Controlled)
The current controlled bi-phasic waveforms
lowers the electrical threshold for successful
defibrillation, besides adjusting for impedance
High Energy Efficiency
100 charge / discharge of 300J with fully charged
new battery
Wide Energy Levels
2-300 J of energy level can be selected for
Trolley defibrillation by the user
Option
Remote energy selection and charging
Available Remote energy selection, charging and discharging
through paddles facilitate convenient usage
Voice Prompt Support
Continuous voice prompts and on screen messages
to aid in revival and resuscitation process
Metronome Signal for CPR Support
Metronome signal for synchronizing chest
compression during CPR
Synchronized Cardioversion
Synchronized Cardioversion function is available
for providing defibrillation on sync with ECG
waveform
24 Events
24 Memorises always the last 24 Critical Event ECG
information which can be viewed or recorded
Patient-Paddle Contact Indication
Patient-Paddle quality of contact is provided on
screen
Optional Enhancements*
AED Mode with Selectable Energy Protocols Non-invasive Blood Pressure
In Automated External Defibrillator (AED)mode, Accurate NIBP measurements powered by
the shock sequence can be selected based on the
requirement
Pulse oximetry Capnography or External Pacing
O2 Accurate SpO2 measurements powered by
CO2/
PACEMAKER Accurate monitoring of ETCO2 with Masimo Sensor,
Option of Mainstream or sidestream
External Transcutaneous Pacemaker with Fixed or
Demand Mode
*Optional Enhancements at additional cost
Product Specifications
Manual Defibrillator
Defibrillator waveform Current Controlled, Biphasic
Energy selection option 2-300 Joules in steps of 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 250, 300 Joules
Energy selection control Selected using keys located on the front panel or on the sternum paddle
Charge control Control on the front panel and on the apex paddle
Charge ready indication Charge done LED on the front panel CHARGE key and Charge done LED on the apex paddle
Synchroniser Energy is delivered within 50 msec of the detected R-wave peak.
Patient impedance 25 – 200 Ohms
AED
AED mode selection control Control on the front panel
Shock sequence Low-Low-Low / Low-Low-High / Low-High-High (User selectable)
Charge ready indication Onscreen display, voice prompt and blinking LED in the SHOCK key.
Shock delivery control Control on the front panel with blinking LED
ECG analysis time < 15 seconds
ECG
ECG Input modes ECG input through Paddles or ECG Patient cable
ECG Lead selection LEAD I / II / III / PADDLES (3 Lead Patient cable)
LEAD I / II / III / aVR / aVL / aVF / V / PADDLES (5 Lead Patient cable)
CMRR >90 dB at 50 Hz
Frequency response 0.5 to 40 Hz
Heart rate display 10 to 300 bpm; Accuracy ± 2 bpm
User gain settings 8 level setting 2.5, 5, 7.5, 10, 15, 20, 30 and 40 mm/mV
Sweep speed 25 ± 1 mm/sec
Reset recovery Automatic recovery of waveform within 0.5 seconds after overload or defibrillation
MASIMO SPO2
SpO2 Range 1 – 100%
Accuracy ±2% (adult/child, in non-motion state), ±3% (adult/child, in motion state) within the measurement range of
70%~100%. 1%~69% is not defined.
Averaging time 2-4 / 4-6 / 8 / 10 / 12 / 14 / 16 Seconds (User selectable)
Resolution 1%
Pulse Rate range 25 – 240 bpm
Perfusion Index resolution 0.01%
SunTech NIBP
Method Oscillometric
Operating Modes Manual, Automatic and Stat
Product Specifications
Blood Pressure Range
Systolic Adult: 40 – 250 mmHg | Paediatric: 40 – 230 mmHg
Diastolic Adult: 20 – 200 mmHg | Paediatric: 20 – 160 mmHg
MAP Adult: 26 – 220 mmHg | Paediatric: 26 – 183 mmHg
Pressure Transducer Accuracy ± 3 mmHg or 2% of the reading whichever is greater
Cycle Time in Auto mode 1, 2, 3, 5, 10, 15, 30, 60, 90 Minutes (User selectable)
Cycle Time in Stat mode 5 Minutes
MASIMO ETCO2
Method Option: Mainstream or Sidestream
CO2 Measurement range 0.0 – 25.0 vol% (0mmHg~190mmHg)
Accuracy 0~15%: ±(0.2 vol% + 2% of reading)
15~25%: not defined
Display unit Vol% or mmHg
CO2 resolution 1mmHg, 0.1kPa or 0.1%
Respiration rate (awRR) 0 to 150 ± 1 breaths/min
Warm-up time < 10 seconds
Calibration Sidestream - An automatic zeroing is performed 1 to 3 times per day.
Mainstream - Zeroing recommended when changing Airway adapter.
Dimensions with weight 1.3"" x 3.1"" x 1.9""; <130 g - Sidestream
1.49” x 1.45” x 1.34”; < 25 g - Mainstream
External Pacing
Type External transcutaneous pacemaker
Pacing mode Fixed or Demand
Waveform Rectangular pulse
Pulse duration 40 ± 2 msec
Pacing rate 30 to 180 ppm
Output current 0 to 150mA
Refractory period 340 msec between 30 and 80 ppm. | 240 msec above 80ppm.
Thermal Recorder
Paper speed 25 ± 1 mm/sec
Paper size and type Thermal paper in rolls. 58 mm width, 15 meters
Print channel 1
General
Display 7” Colour TFT, Resolution 800 x 480
Dimensions 370 mm (W) x 300 mm (H) x 290 mm (D)
Weight Less than 8.5 Kg. (including battery, external paddles)
Operating temperature range 0 to 40° C at non condensing RH between 15 and 95%
Storage temperature range -10 to 60° C at non condensing RH between 20 and 80%
AC input 100 – 240 Vac, 50/60 Hz
Power consumption < 240 VA
Battery type Sealed Lead Acid 12V, 4.5 AH, Rechargeable
Battery capacity > 100 discharges of 300 Joules
Battery charging time Approx. 3 hours to 90% of full capacity. 18 hours to 100% capacity
Event information Last 24 critical events are stored along with ECG information. Events include MARK key press, Shock delivery
and HR Alarm violation.
Trend Last 200 NIBP measurement data and last 200 Alarm violation information.
*Technical specification subject to change
CERTIFIED ISO 13485 : 2016 COMPANY
BPL Medical Technologies Private Limited
Regd. Office: 11th KM, Bannerghatta Road,
Arakere, Bangalore - 560076, India.
Toll Free: 1800-4252355
Website: www.bplmedicaltechnologies.com
For Enquiries: sales.medical@bpl.in
CIN: U33110KA2012PTC067282 Follow us on
© 2019 BPL Medical Technologies Private Limited. All rights reserved. BPL Medical Technologies Private Limited reserves the right to make changes in BPL RELIFE900 4PGB 07:05:19
product features, specifications, aesthetics and/or to discontinue the same at any time without notice or obligation