HXS300
ANSI Smart
Poly Phase Meter
(FM16S FM9S)
HXS300
HXS300 is a new generation of poly
phase smart meter which complies with
FM16S and FM9S, it meets the CA0.2 of
ANSI C12.20 standard.With a GPRS
communication module, It is compatible
with AMI software and provide remote
energy consumption monitoring and
meter configuration
Highlights
Open Communication Protocol: ANSIC12.18/C12.19
ANSI C12.20 - Accuracy Class of CA0.2
Time of Use metering
Advanced metering functions such as reactive measurement and Power Quality Monitor
Load Profile
Maximum Demand
Event Log
Anti-tamper design
Service self-diagnostic
Main Functionalities
Measurement programmable Special day
· Active energy Measurement: Delivered, Up to 500 event detections and records
Received, Delivered + Received, Delivered Battery can be replaced(optional)
– Received Maximum demand / Cumulative demand
· Reactive energy Measurement Up to 8 channels of load profile recording in 8MB
· Instantaneous value measurement data memory (optional)
LCD Display Up to 12-month billing data
· Configurable measured data, Large digit Detect exception tamper events: Device
LCD display, easy for reading reconfigured, Power outage, Open cover,
· Display of energy configurable to 4\5\6digits Magnetic Influence, etc.
· LCD backlights (optional) Service self-diagnostic of Phase voltages, Cross
Time-Of-Use phasing, voltage and current polarity, Reverse
· Up to 4 TOU periods & 4 Seasons Phase sequence, etc.
· Up to 8 daily rate schedule, one holiday Power Quality Monitor: Under Voltage, Over
schedule Voltage, Phase Failure, voltage and Current
· Up to 50 TOU Schedule & 50 unbalance, etc
Specifications
Accuracy CA0.2
Voltage
Reference voltage 120V-480V
Operating voltage range 96V-528V
Current
Basic current 2.5A for FM9S 30A for FM16S
Maximum current 20A for FM9S 200A for FM16S
Creep No more than one pulse measured per
0.000A(no current) quantity, conforming to ANSI C12.1
requirements
Starting current 10mA for FM9S 100mA for FM16S
Frequency 50/60Hz+/- 5%
Temperature
Operation range -40℃ to +85℃
Limit range for storage and transport -40℃ to +85℃
Humidity 0% to 100% non-condensing
Battery
Self-life time 10+ years.
Work-life time 5+ years
Power Consumption
Power consumption in voltage circuit (active) ≤1 W
Power consumption in voltage circuit (apparent) ≤4 VA
Power consumption in current circuit
≤0.5 VA
Insulation Strength
Surge Voltage 2.5kV, 2500 strikes
AC voltage test 4kV during 1min
Impulse voltage test 1.2/50µs mains connections 6kV
EMC
Electrostatic discharges(Contact discharges) 8kV
Electrostatic discharges(Air discharges) 15kV
Surge immunity test 4kV
Fast transient burst test 4kV
Electromagnetic RF fields (80MHz to 2000MHz) 10V/m(with current), 30V/m(without current)
Housing
Protection class IP54
Meter cover Transparent PC
Meter base Opaque PC + fiber glass
Display
Digit size 5.2mm x 11.4mm
Number of digits 6
Weight
Net weight approx.1.2kg
Dimension
177mm×177mm×152mm
Standard
ANSI C12.1 American National Standard - for Electric MetersCode for Electricity Metering
ANSI C12.10 American National Standard - for Physical Aspectsof Watthourmeters Safety Standard
ANSI12.20 American National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes
ANSI12.18 American National Standard Protocol Specification for ANSI TYPE 2 Optical Port
ANSI C12.19 American National Standard–forAmerican National StandardFor Utility IndustryEnd DeviceData Tables
IEEE Standard for Surge Withstand Capability(SWC) Tests for Relays and Relay Systems Associated with
ANSI C37.90.1
Electric Power Apparatus
ANSI C62.41 IEEE Recommended Practice on SurgeVoltages in Low-Voltage AC Power Circuits
Dimensions
· Connection Diagram
·
· FM9S FM16S