2.
20
0.75 0.70 0.75
0.10 0.30 0.10
7.5cm Ø PVC 7.5cm Ø PVC
DOWNSPOUT DOWNSPOUT
INLET
0.10 0.30 0.10
LEGEND:
0.50
0.10
SEWAGE LINE CO CLEAN OUT SHO SHOWER
0.30 WATER LINE CV CHECK VALVE FAU FAUCET
OUTLET 10mm Ø RSB SP. AS
SHOWN BOTWAYS ST SEPTIC TANK
GATE VALVE WH WATER HEATER
20cm Ø PVC
12mm Ø MANHOLE LIFTING DS DOWNSPOUT
DRAINAGE PIPE CHECK VALVE SO STUB OUT
HANDLE
1.30
1.10
1.30
0.50 WATER METER VTW VENT THRU ROOF KS KITCHEN SINK
0.60
PLAN CB CATCH BASIN LV LOOP VENT MH MANHOLE
WC WATER CLOSET RD ROOF DRAIN SD SHOWER DRAIN
10mm Ø LIFTING HANDLE ON 12mm
10mm Ø LIFTING HANDLE ON 12mm LD LAVATORY DRAIN FD FLOOR DRAIN GV GATE VALVE
0.30
Ø PVC GRAVITY HOLE 7.5cm Ø PVC
0.10
DOWNSPOUT
5cm THK. CB COVER REINF. W/
10mm Ø RSB SP. AS SHOWN BOTHWAYS
0.05
GROUND LINE
0.10 0.40 0.10
0.10 0.40 0.05
0.60
0.20 0.60 0.10 0.60 0.10 0.60 0.20
2.40
2-LAYERS 10mm Ø RSB SP. AS
4" THK. CHB SHOWN BOTWAYS
PLAN 20cm Ø PVC DRAINAGE PIPE
SECTION
CB-2 3 PLUMBING LEGENDS
P2 SCALE NTS
12mm Ø RSB SP. @ 8-12mm Ø 8-12mm Ø RSB SP. AS 12mm Ø MANHOLE
20cm O. C. BOTHWAYS DIAGONAL BARS SHOWN BOTHWAYS LIFTING HANDLE
0.10 0.30 0.10
20cm Ø PVC 7.5cm Ø PVC
DRAINAGE PIPE DOWNSPOUT PLUMBING NOTES:
0.10 0.30 0.10
0.10
0.10
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED
0.50
0.30
ACCORDING TO THE REQUIREMENTS OF THE PLUMBING CODE OF
WATER LEVEL THE PHILIPPINES AND THE NAT. BLDG. CODE.
WATER LEVEL
2-LAYERS 10mm Ø RSB SP. AS
WATER LEVEL 4" THK. CHB SHOWN BOTWAYS
2. ALL SLOPES FOR HORIZONTAL BRANCHES OF SEWAGE AND
WASTE WATER LINE SHALL MAINTAIN ONE PERCENT MINIMUM.
CHAMBER - 3 0.50
CHAMBER - 1 CHAMBER - 2 (LEACHING)
1.80
PLAN
2.10
(DIGESTIVE) (DIGESTIVE) 3.ALL FIXTURES OR BRANCH OF FIXTURES SHALL BE VENTED.
2.00
1.50
10cm THK.
10mm Ø LIFTING HANDLE ON 12mm
12mm Ø VERT' RSB CHB Ø PVC GRAVITY HOLE
SP. @ 30cm 2cm THK. CEMENT 4. WATER LINES SHOULD BE uPVC UNITEC PIPES OR APPROVED
INTERIOR WALL 5cm THK. CB COVER REINF. W/
12mm Ø HORT' RSB
PLASTER FINISHED
7.5cm Ø PVC DOWNSPOUT 10mm Ø RSB SP. AS SHOWN BOTHWAYS EQUAL.
SP. @ EVERY
20cm Ø PVC DRAINAGE PIPE
2-LAYERS CHB WITH
0.05
GROUND LINE
0.10 0.40 0.10
WATERPROOFING
0.10 0.40 0.05
5. SEWAGE WASTE, WATER, VENT AND DOWNSPOUT LINES SHALL
BE SANIMOLD PVC PIPES OR APPROVED EQUAL.
0.60
0.20
6. GROUND DRAINAGE LINES SHALL BE 200mm Ø PVC PIPES OR
12mm Ø RSB SP. AS
SHOWN BOTHWAYS
12mm Ø RSB SP. ATLANTA SPIRAL PIPE.
10mm Ø RSB SP. AS 2-LAYERS
@ 30cm
SHOWN BOTWAYS 4" THK. CHB
12mm Ø RSB SP. 7. THE DIGESTION OF SEPTIC VAULT SHALL BE WATER PROOFED.
@ 30cm SECTION SECTION
CB-1 8. ALL PLUMBIMG WORKS SHALL BE DONE UNDER THE DIRECT
SUPERVISION OF A DULY LICENSED SANITARY ENGINEER OR
MASTER PLUMBER.
1 SEPTIC TANK DEATIL 2 CATCH BASIN DETAIL 4 PLUMBING NOTES
P2 SCALE 1:20 mts P2 SCALE 1:20 mts P2 SCALE
LOGO DRY SEAL IMPORTANT PROJECT TITLE: PROJECT OWNER: REVISION: SHEET NO.
R . A 9 2 6 6 , A R T . I V , S E C . 3 3
OWNERSHIP OF PLANS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENT DATE:
M A S T E R P L U M B E R DRAWING AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, SEPTIC TANK DETAIL
STAMPED AND SEALED AS INSTRUMENT OF SERVICE ARE THE INTELLECTUAL
PROPERTY OF THE ARCHITECT/ENGINEER WHETHER THE OBJECT WHICH THEY ARE
MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE
"PROPOSED EXTENSION OF RESIDENTIAL HOUSE" LEONEL S. MAMUAD CATCH BASIN DETAIL
PLUMBING LEGEND P
P R C NO. : P T R NO. : OR TO MAKE COPIES OF THE SAID DOCUMENTS FOR USED IN ANY REPETITION OF THEIR O W N E R PLUMBING NOTES
T I N NO.: I S S U E D ON :
PROJECTS OR BUILDINGS WHETHER EXECUTED PARTLY OR IN WHOLE WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT/ENGINEER OR AUTHOR OF THE SAID DOCUMENT.
2 11
ALL ARCHITECT/ENGINEER SHALL INCORPORATE THIS PROVISION IN ALL CONTRACT
I S S U E D AT : DOCUMENT AND THE OTHER INSTRUMENT OF SERVICE LOCATION: BRGY. 7, SAN MIGUEL, SAN NICOLAS, ILOCOS NORTE LOCATION: BRGY. 7, SAN MIGUEL, SAN NICOLAS, ILOCOS NORTE