TJ695DW5A

The document provides specifications for the TJ695DW5A Diesel Generator Set, which has a standby power output of 695 kVA and a prime power output of 634 kVA. It features a DOOSAN engine with a 12-cylinder configuration and a Marelli alternator, designed for 50 Hz operation. The generator is compliant with various international standards and is available in canopied and open skid configurations.

Uploaded by

bakhouche
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views1 page

TJ695DW5A

The document provides specifications for the TJ695DW5A Diesel Generator Set, which has a standby power output of 695 kVA and a prime power output of 634 kVA. It features a DOOSAN engine with a 12-cylinder configuration and a Marelli alternator, designed for 50 Hz operation. The generator is compliant with various international standards and is available in canopied and open skid configurations.

Uploaded by

bakhouche
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TJ695DW5A

Diesel Generator Sets / 50 Hz

Power Output Ratings 50 Hz / 400 V

kVA 695
Standby Power (ESP)
kW 556

kVA 634
Prime Power (PRP)
kW 507

Engine

Manufacturer DOOSAN
Origin KOREA
Model P222LE ­S
No of Cylinder / Configuration 12 ­ V TYPE
Displacement lt 18,3
Bore / Stroke mm 128 / 142
Compression Ratio 14,6:1
Aspiration Turbocharged and Intercooled
Governor Type ELECTRONIC
Cooling System WATER
Standby Power
Coolant Capacity lt 113
Standby power is defined as the maximum power
Lubrication Oil Capacity lt 35 available during a variable electrical power
Electrical System VDC 24 sequence, under the stated operating conditions, for
which a generating set is capable of delivering in the
Speed / Frequency 1500 rpm / 50 Hz event of a utility power outage or under test
Engine Gross Power kWm 603 conditions for up to 500 hours of operation per year
under average of 70% load. Overloading is not
110 % 142,2
permissible.
100 % 130
Fuel Consumption lt/h Prime Power
75 % 99,8
Prime power is defined as being the maximum power
50 % 68,3 which a generating set is capable of delivering
Exhaust Outlet Temperature °C 598 continuously whilst supplying a variable electrical
load. Average load should be 70%. The generator can
Exhaust Gas Flow m³/min 93,9 be overloaded 10% for 1 hour per 12 hours.
Combustion Air Flow m³/min 41,8
Cooling Air Flow m³/min 675

Alternator

Manufacturer MARELLI
Origin ITALY
Model MJB355MA4
No of Phase 3
Power Factor 0,8
No of Bearing SINGLE
No of Poles 4
No of Leads 12
Voltage Regulation ( Steady State) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR (Automatic Voltage Regulator), Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency Hz 50
Voltage Output VAC 230 / 400
Rated Power (Standby) kVA 750
Efficiency % 94,7

W x L x H (mm) Weight (kg) lt Fuel Tank (lt) Noise dB(A)

Canopied 1687 x 5019 x 2400 5410 1125 TBA


Open Skid 1400 x 3800 x 1920 4240 850 TBA

­ Technical information and values are according to ISO8528, ISO3046,NEMA MG­1.22, IEC 60034­1, BS 4999­5000, VDE 0530 standards.
­ Producing with ISO9001, ISO14001, OHSAS18001, TSE, CE standards.
­ All information given in this leaflet is intended for general purposes only. Due to a policy continuous improvement Teksan reserves the right to amend
details and specifications without notice and all information given is subject to the Teksan's current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Avaliable N/A: Not Applicable TTD695DW5A0510­EN
www.teksangenerator.com

27.07.2010 10:25