0% found this document useful (0 votes)
52 views2 pages

IDP Monitor 2 Datasheet

The IDP-Monitor-2 is an addressable dual monitor module designed for Honeywell Farenhyt Series fire alarm control panels, capable of monitoring two separate Class B circuits for devices like waterflow switches and pull stations. It features supervised wiring, rotary address switches for installation, and is UL, CSFM, and MEA listed. The module requires a 4” square electrical box for installation and operates within a temperature range of 32º-120ºF.

Uploaded by

Aya Agiba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

IDP Monitor 2 Datasheet

The IDP-Monitor-2 is an addressable dual monitor module designed for Honeywell Farenhyt Series fire alarm control panels, capable of monitoring two separate Class B circuits for devices like waterflow switches and pull stations. It features supervised wiring, rotary address switches for installation, and is UL, CSFM, and MEA listed. The module requires a 4” square electrical box for installation and operates within a temperature range of 32º-120ºF.

Uploaded by

Aya Agiba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Addressable Dual Monitor

Module
IDP-Monitor-2
The IDP-Monitor-2 is an addressable monitor module with two
initiating circuits for use with Honeywell Farenhyt Series fire alarm
control panels (FACPs). The IDP-Monitor-2 acts as an interface to
contact devices, such as waterflow switches and pull stations.
IDP-MONITOR-2
The IDP-Monitor-2 supports Class B supervised wiring
to the load device. Conventional 4-wire smoke detectors Compatibility
can be monitored for alarm and trouble conditions.
The IDP-Monitor-2 is compatible with
Because the IDP-Monitor-2 is capable of monitoring two separate Class B the following Farenhyt Series FACPs:
circuits, it is ideal for waterflow tamper switch and flow switch monitoring. • IFP-2100 / IFP-2100ECS / RFP-2100
• IFP-2000 / IFP-2000ECS / RPS-2000
Installation • IFP-1000 / IFP-1000ECS
The IDP-Monitor-2 mounts directly into a 4” square electrical box. The • IFP-300 / IFP-300ECS
box must have a minimum depth of 2-1/8”. A surface mount electrical • IFP-100 / IFP-100ECS
box (System Sensor® PN SMB500) is available from Honeywell. • IFP-75
• IFP-50

F E AT U R E S & B E N E F I T S
• Monitor two circuits, • Attractive ivory cover
with unique plate
addresses,
• Rotary address
simultaneously
switches for fast
• Support for Class B installation
wiring
• SEMS screws for easy
• Fully supervised wiring
• Panel controlled • UL Listed
status LED that
• CSFM Listed
fl ashes green in
normal state and is • MEA Listed 457-99-E
solid red in alarm Vol. V
IDP-Monitor-2 Technical Specifications
For a complete listing of all
compliance approvals and
certifications, please visit
www.farenhyt.com.

Microsoft, Windows, and


the Windows Logo are
registered trademarks
or trademarks of
Microsoft Corporation.

Honeywell® and
System Sensor® are
registered trademarks
of and Farenhyt™ is a
trademark of Honeywell
International, Inc.

This document is not


intended to be used for
installation purposes. We
try to keep our product
information up-to
date and accurate. We
cannot cover all specific
applications or anticipate
Typical Wiring for IDP-Monior-2 Module, NFPA Style B all requirements. All
specifications are subject
to change without notice.

For Technical
Support, Please call
SPECIFICATIONS* ORDERING INFORMATION 800-446-6444.
Physical: 4.5" H x 4" W x 1.3 D ( 11.4 x 10.2 x 3.2cm) IDP-Monitor-2: Dual Monitoring Module
Shipping Weight: 6.3oz (196g)
ACCESSORIES
ELECTRICAL RATINGS SMB500: 4” Square Surface Mount Electrical Box
Operating Voltage: 15 – 32VDC
Maximum Current Draw: 6.4mA (LED on)
SLC Standby & Alarm Current: 750μA max @ 24
VDC (one communication every sec with 47k EOL)
End of Line Resistance: 47kW

ENVIRONMENTAL
Operating Temperature: 32º-120ºF (0ºC – 49ºC)
Humidity: 10 to 93% non-condensing)

For more information


Learn more about Honeywell’s Farenhyt Series
and other products available by visiting
www.farenhyt.com

Honeywell Security & Fire


12 Clintonville Road
Northford, CT 06472 Doc 350289 | Rev G| 09/17
800-328-0103 © 2017 Honeywell International Inc.