Safety technology
Simply reliable:
fail-safe sensors for
mobile machines
Fail-safe inductive sensors
Safety sensor enters the safe
state, logic “0”, as soon as the
sensor is damped
Installation costs and time
reduced as the target is only
required in the end position
Comprehensive self-diagnostics
for maintenance-free continuous
operation
Designed for use in harsh
environments
Target activates safe state
The fail-safe sensors switch into the safe state as soon as the target is
detected inside the safe switch-off distance. The safety-related function
is inverted when compared to the previous fail-safe sensors. This function is
ideal in applications such as the protection of crane installations or industrial
robots because the targets only need to be mounted at the end positions.
Both the number of metallic targets and the installation complexity are
considerably reduced.
Perfectly equipped for mobile use
Thanks to the robust design the sensor is perfectly suited for use in mobile
machines. Applications on mobile machines such as monitoring whether
supports are fully extended or waste bins gripped in the right way.
Neither strong vibration nor extreme temperatures and cleaning processes
affect the function of the fail-safe sensor in any way.
Design Housing length Installation Enable zone Safe Order
switch-off distance no.
[mm] [mm] [mm]
M12 connector · 4 poles
M12 x 1 60 non flush > 6.0 < 3.0 GF854S
M18 x 1 60 flush > 7.5 < 4.0 GG855S
M18 x 1 60 non flush > 11.5 < 6.5 GG854S
M30 x 1.5 65 flush > 14.5 < 8.0 GI855S
M30 x 1.5 65 non flush > 21.5 < 12.0 GI854S
Connection technology Further technical data
Design Description Order
no. Safe state when properly
Safety-related function
damped
Operating mode Permanent operation
Socket, M12,
EVM001
2 m, PUR cable, halogen-free, black ISO 13849-1 Category 2 PL d
Socket, M12, IEC 61508 SIL 2
EVM002
5 m, PUR cable, halogen-free, black
IEC 62061 SIL 2 cl 2
Socket, M12,
EVM003
10 m, PUR cable, halogen-free, black
Use in mobile and harsh
Applications
Socket, M12, applications
EVM004
2 m, PUR cable, halogen-free, black Operating voltage [V DC] 8...32
Socket, M12, IP 65, IP 66, IP 67, IP 68,
EVM005 Protection rating
5 m, PUR cable, halogen-free, black IP 69K
Socket, M12, Protection class III
EVM006
10 m, PUR cable, halogen-free, black
Electrical design PNP
2 x OSSD,
Dimensions Output function
CB 24 I / C 1
60 Switching status indication [LED] yellow (4 x 90°)
49
40 5
Permanent current rating [mA] 50
Ambient temperature [°C] -40...85
M12 x1
M12x1
4
Threaded sleeve,
LED 4 x 90° 17 fixing nuts:
Brass
GF854S Materials plated with white bronze
60 60
Sensing face: LCP yellow
49 49 Connector housing: PEI
45 35 10
M18 x1
M12 x1
M18 x1
Reliable operation without interruptions
M12 x1
4 4 The sensor is equipped with sophisticated internal
LED 4 x 90° 24 LED 4 x 90° 24 diagnostic functions. Among others, they detect
GG855S GG854S component defects, short circuits or cross faults
reliably and disconnect the outputs in case of a fault.
We reserve the right to make technical alterations without prior notice. · 11.2020
65
65
53
54
50
52 When used as intended, maintenance of the sensor
34 15
is no longer necessary.
M30x1,5
M12x1
M30x1,5
M12 x1
5
LED 4 x 90° 36 5
LED 4 x 90° 36
GI855S GI854S
Wiring diagram
1 L+
+24 V
2 A2
IN2
3 L 1
GND
4 A1
IN1
1) safety-related logic unit
For further technical details please visit: ifm.com