The CETUS x12 Patient Monitor features a 12.1” color TFT LCD screen with capabilities for 8 waveform display and up to 12-lead ECG analysis. It includes various monitoring functionalities such as SpO2, NIBP, and respiratory measurements, along with optional enhancements like touch-screen and multi-gas analysis. The device supports wired/wireless CMS and HL7 protocol, making it suitable for diverse clinical environments.

Uploaded by

MOHAMED MATOUGH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views3 pages

9 Axcent Cetus 12

The CETUS x12 Patient Monitor features a 12.1” color TFT LCD screen with capabilities for 8 waveform display and up to 12-lead ECG analysis. It includes various monitoring functionalities such as SpO2, NIBP, and respiratory measurements, along with optional enhancements like touch-screen and multi-gas analysis. The device supports wired/wireless CMS and HL7 protocol, making it suitable for diverse clinical environments.

Uploaded by

MOHAMED MATOUGH
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CETUS x12 Patient Monitor

Features
• 12.1” color TFT LCD screen
• 8 waveform display, up to 12-lead ECG analysis
• Useful calculation
(Hemodynamic, Drug Dose, Oxygenation, Ventilation)
• Pacemaker detection
• ST & arrhythmia analysis
• OxyCRGs screen
• Wired/Wireless CMS, support HL7 protocol to HIS
• SpO2 pulse-tone modulation (Pitch Tone)
• MEWS (Modified Early Warning Score)
• Graphical & tabular trend review (120 hours)
• Rechargeable Lithium-Ion Battery (2600 mAh)
12.1”color TFT LCD screen, wide and flat screen design,ecnomic and reliable

Configuration: ECG+SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery


Optional: Touch-Screen, 12-lead ECG, Masimo SpO2, 2/4/6 IBP, C.O., EtCO2, Multi-Gas, BIS, NMT,
VGA, Thermal Recorder, Wired/Wireless CMS

Technical Specifications

Display RESP
12.1” TFT (touch screen optional) Measurement method: Thoracic electrical
Resolution: 800 x 600 bioimpedance
Number of traces: 8 waveforms Rate: 0 – 150 bpm
Measuring lead: Lead I, II
ECG Wave gain: ×0.25, ×0.5, ×1, ×2
Lead type: 3-lead, 5-lead, 12-lead Respiratory impedance range: 0.5-5Ω
ECG waveform: 2 channels, 7 channels, Baseline impedance: 500-4000Ω
12 channels Gain: 10 grades
Display sensitivity: 2.5 mm/mV (×0.25), Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
5 mm/mV (×0.5), 10 mm/mV (×1.0),
20 mm/mV (×2.0) Pulse Rate
Wave sweep speed: 6.25 mm/s, 12.5 mm/s, Range: 30~254 bpm
25 mm/s, 50 mm/s Resolution: 1bpm
Bandwidth Accuracy: ±2bpm (non-motion)
Diagnostic mode: 0.05 Hz~100 Hz ±5bpm (motion)
Monitor mode: 0.5 Hz~40 Hz Refreshing rate: 1s
Surgery mode: 1Hz~20Hz
Strong filter mode: 5 Hz~20 Hz TEMP
CMRR >100 dB Accuracy: ±0.1 °C or ±0.2 °C °F (without probe)
Notch: 50/60 Hz notch filter can be set to Measurement range: 5~50 °C (41~122 °F)
on or off Channel: Two channels
Differential input impedance >5MΩ Resolution: 0.1 °C
Electrode polarization voltage range: ±400 mV Parameters: T1,T2 and TD
Baseline recovery time <3s after defibrillation
(in monitor and surgery mode)
Calibration signal: 1mV (peak - peak),
accuracy ±3%

7-lead ECG

www.axcentmedical.com
CETUS x12 Patient Monitor
Technical Specifications

NIBP SpO2
Measurement method: Automatic oscillome- Measurement range: 0-100%
tric method Resolution: 1%
Operating mode: Manual, automatic, Accuracy: ±2% (70-100%, Adult/Pediatric);
continuous ±3% (70-100%, Neonate);
Measurement unit: mmHg/kPa selectable 0-69%, unspecified
Typical measurement time: 20~40 s Refreshing Rate: 1s
Measurement type: Systolic, Diastolic, Mean
Measurement range (mmHg) Masimo SET® SpO2 (Optional)
Range of Systolic pressure: Adult 40-270 Measurement range: 0-100%
Pediatric 40-200 Resolution: 1%
Neonatal 40-135 Accuracy: ±2% (70-100%, Adult/Pediatric,
Range of Diastolic pressure: Adult 10-210 non-motion, low prefusion);
Pediatric 10-150 ±3% (70-100%, Neonate,
Neonatal 10-95 non-motion);
Range of Mean pressure: Adult 20-230 ±3% (70-100%, motion);
Pediatric 20-165 0-69%, unspecified
Neonatal 20-105 Refreshing Rate: 1s
Measurement accuracy
Recorder (Optional)
Maximum average error: ±5 mmHg
Built-in, Thermal dot array
Maximum standard deviation: 8 mmHg
Horizontal resolution: 16 dots/mm (25 mm/s
Resolution: 1 mmHg
paper speed)
Interval: 1, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180,
Vertical resolution: 8 dots/mm
240, 480 minutes
Paper speed: 25 mm/s, 50 mm/s
Overpressure protection: Software and
Number of waveform channels: 3
hardware, double safety protection
Cuff pressure range: 0-280 mmHg
Operation Environment
Power: AC 100-250V, 50/60Hz
Temperature: 5-40 °C
Humidity: <80%
Patient Range: Adult, Pediatric, Neonate
Battery backup: Standard 2-3 hrs (2.600 mAh),
optional 3-5 hrs (4.800 mAh)