KD600 Series Catalogue
KD600 Series Catalogue
Company Introduction
Shenzhen K-Easy Automation Co.,Limited is a professional manufacturer, specialize in R&D And production
of AC drives. We have built up a comprehensive product family. Frequency inverters' power covers the range
from 0.4 to 630kW, and voltage range is between 220V and 480V. More than inverters are running smoothly
300, 000 units at different industrial sites
WHY US
We believe “ quality is life ”,so we will test all products before shipment,All Module of our VFD will be used quality is life with
Infenion only,With years of persistence, the total failure ratio of Our frequency inverters has been controlled below 1%. We never lose
a customer because of the quality problem.
With Strong R&D and Engineer Team, makes our after-service very easy, For all doubts and requesting for technologies supporting,
We can offer detailed Solution without delay, so for us,“Not Only Products,But also solutions”
All our products will be offered with 24 months Warranty Period instead of 18 months
Voltage
2 Voltage level 2S: Single-phase 220V Range:-15%~20% Can be always offered within 2 hours
level 4T: Three-phase 380V Range:-15%~20%
Version: A01
General Pupose Seires Adaptable
power 3
Adaptable motor
power(KW) 0.4KW~630KW
Version: A01
1
www.keasyautomation.com KD600M
X4
S1
I
S2
(near the inverter ground)
5
_V
Note3
10
0
For Small Motors OFF OFF
AO
+ -
I
GND
S4
Note: AO port as voltage type When
U the signal is output, the
maximum output is 2mA
GND
A B TA TB TC Y GND
3
www.keasyautomation.com KD600
The electrical part is separated from the cooling air duct layer
by layer, and each part is independent, which can effectively
deal with the dust problem of circuit boards and sensitive
The machine has the characteristics of high temperature devices.
resistance: scientific air duct design, rapid heat dissipation, low
temperature rise of the machine, and no need to reduce the
capacity under the ambient temperature of 50 ℃.
Top cover
Description of
dial switch
Control
circuit terminal Dial switch
Control terminal
Main
Terminal
circuit terminal
identification
Machine name plate Main circuit
terminal
Fan hood
www.keasyautomation.com KD600
High Performance
Open-loop steady
speed accuracy
KD600 Series
Based on many years of research and development technology 3. Instant Power Failure Without 4. Fast Rotary Speed Tracking
Stopping The Drive completes the speed tracking of the
achievements and market feedback, KD600 series AC Drive When the power failure instantly, the Drive shaft of the high-speed rotating motor within
realizes generation feedback by reducing the 300ms, realizing fast and smooth start.
have been fully upgraded in terms of structure, hardware and operating frequency and maintains the stability
of the bus voltage. When the grid input is
software on the basis of the excellent previous work. normal, it returns to normal operation.
High Performance:
acceleration caused by excessive load, which may cause a large overcurrent of the and the braking protection is more
comprehensive and intelligent. General model: 0.75-30KW built-in brake unit
i n v e r t e r.
KD600 series: 0.75-75KW built-in brake unit
Function code display PID FDT S curve Power down and restart V/F separation control
hidden function R
(-)fuse
Overexcitation
braking DC braking
Current limit
protection Stalled protection Motor thermal protection Counting function ...... S
fuse fuse fuse fuse
(-) (+) (-) (+) PC PLC
U V W U V W U V W
www.keasyautomation.com KD600
Rich Scalability
Reasonable Structural Design
Va r i o u s f u n c t i o n e x p a n s i o n c a r d s , I O c a r d s , r e l a y o u t p u t c a r d s , a n d v a r i o u s P G
cards can be selected according to requirements to match various encoders,
communication expansion cards, etc. Can be customized according to demand.
Using the new high performance current vector Independent grounding system selection
algorithm, it can easily drive asynchronous switch (through the screw access or not to
High-Performance Keypad motor and permanent magnet synchronous choose), easy to solve the problem of
motor. EMC interference and leakage current.
Opening size of
keyboard pocket Over current Output phase loss PID feedback fault
Speed control Starting
control mode range
Main contactor torque
Overheated Under voltage
abnormal
No PG vector
(synchronous motor)
motor overload Rapid protection Unbalanced output
No PG vector
Dual display keyboard (asynchronous motor)
Abnormal motor
Inverter overload System exception With PG vector (synchronous
detection
and asynchronous motor)
Control panel power
Output phase loss Input phase loss short circuit protection
Opening size of
keyboard pocket
Comprehensive protection Excellent control
Comprehensive protection of the inverter and Powerful torque output ensures stable and
motor safety, save trouble and worry. smooth load starting.
www.keasyautomation.com KD600
Installation
Aperture
Installation
Aperture Support network cable introduction
KD600-4T-22G Power Capacity Input Current Output Current Adaptable Output Adaptable Motor
Power Capacity Input Current
Model (KVA) (A) (A) Model Current (KW)
Motor(KW) (KVA) (A) (A)
KD600-2S: 0.7KW-2.2KW 1 phase 220V 50/60Hz KD600-4T: 0.7KW-500KW 3 phase 380V 50/60Hz
KD600-4T-30G KD600-2S-0.7G 1.5 8.2 4.7 0.75 KD600-4T-30G 40 62.5 60 30
KD600-4T-37G KD600-2S-1.5G 3.0 14.0 7.5 1.5 KD600-4T-37G 57 76 75 37
KD600-4T-45G KD600-2S-2.2G 4.0 23.0 10.0 2.2 KD600-4T-45G 69 92 91 45
KD600-4T-132G KD600-4T: 0.7KW-500KW 3 phase 380V 50/60Hz KD600-4T-160G 231 307 304 160
KD600-4T-0.7G 1.5 3.4 2.3 0.75 KD600-4T-185G 255 333 330 185
KD600-4T-160G
KD600-4T-1.5G 3.0 5.0 3.7 1.5 KD600-4T-200G 287 380 377 200
KD600-4T-185G
KD600-4T-2.2G 4.0 5.8 5.1 2.2 KD600-4T-220G 311 429 426 220
KD600-4T-200G KD600-4T-4.0G 5.9 10.5 8.5 4.0 KD600-4T-250G 355 470 465 250
KD600-4T-220G KD600-4T-5.5G 8.9 14.6 13 5.5 KD600-4T-280G 396 525 520 280
KD600-4T-250G KD600-4T-7.5G 11 20.5 17 7.5 KD600-4T-315G 439 605 600 315
KD600-4T-11G 17 26 25 11 KD600-4T-350G 479 665 660 355
KD600-4T-280G
KD600-4T-15G 21 35 32 15 KD600-4T-400G 530 730 725 400
KD600-4T-315G KD600-4T-18.5G 24 38.5 37 18.5 KD600-4T-450G 600 825 820 450
KD600-4T-350G 400 KD600-4T-22G 30 46.5 45 22 KD600-4T-500G 660 910 900 500
KD600-4T-400G
www.keasyautomation.com KD600
P + P- PB R S T U V W
X1~X5: PB P+ P-
MCCB 0.7~11kw main circuit and loop terminal schematic diagram
Frequency:0~200Hz
R R U
(DI5:0~100KHz) V M
Voltage range:10~30V J7: Digital input power selection jumper S S 0.75~18.5KW
DISP1 Keypad external interface T T W
+24V PE P+ P- R S T PB U V W
3 phase 380V input
OPEN CN2 Keypad interface Frequency: 50/60Hz
15~18.5kw main circuit and loop terminal schematic diagram
digital input 1
X1 CN4 Expansion card interface
digital input 2
X2
digital input 3 RS485 terminal
X3 resistance
digital input 4 A P+ P P- R S T PB U V W
X4 J1 485 COMMUNICATION INTERFACE Braking Resistor (self-matched)
digital input 5 6 B
DC reactor (optional) 22~37kw main circuit and loop terminal schematic diagram
X5
High Speed Pulse Input
PB P P+ P-
Analog output MCCB
GND AO R R U
0V-10V:
J1 S S 22~75KW V M
Impedance requirement>10KΩ
3 4 5 GND 0mA-20mA: T T W
Impedance requirement 200Ω~500Ω 3 phase 380V input PE
Frequency: 50/60Hz 45~75kw main circuit and loop terminal schematic diagram
1kΩ~5kΩ Analog input
+10V
reference voltage Open collector output
HDO
Maximum output current 25mA (Pulse output 0~50KHZ)
CME
AI1 J1 Braking Resistor (self-matched)
0~10V: input resistance100kΩ 8
0~20mA:input resistance 500Ω
J1 24V Open collector output 90~110kw main circuit and loop terminal schematic diagram
Braking Unit (optional)
AI2 7 Y
P+ P-
MCCB
COM U
R R
GND 90~350KW V M
S S
W
T T
3 phase 380V input
PE
T1C Electric relay output 1 Frequency: 50/60Hz
132~250kw main circuit and loop terminal schematic diagram
T1B
T1A
PE (connect to the chassis)
Braking Resistor (self-matched) MOTOR(电机)
Products Advantage
Items Specification
Maximum Frequency Vector control:0.00~500.00Hz; V/F control: 0.00~500.00Hz
Carrier frequency 0.5kHz~16kHz ;the carrier frequency is automatically adjusted based on the load features.
Input frequency resolution Digital setting:0.01Hz; Analog setting: Max frequency×0.025%
Control Mode V/F control; Open loop vector control (SVC) Closed loop vector control(FVC)
Start Torque 0.25Hz/150%(SVC); 0Hz/180%(FVC)
Speed range 1~200(SVC); 1:1000(FVC)
Stable speed accuracy ±0.5%(SVC); ±0.02%(FVC)
Torque control accuracy ±5%(SVC)(5Hz以上); ±3%(FVC)
Overload capacity G type:150% rated current for 60s
Torque boost Auto torque boost; Manual torque boost: 0.1%~30.0%
Functions V/F control 4 ways:Line、multi-point、Square V/F curve、V/F separation
Line or S-curve Acc/Dec mode, four kinds of Acc/Dce time,;
Accelerate/Decelerate curve
Ranges of Acc/Dec time is 0.0s~6500.0s
DC braking frequency:0.00Hz~Maximum frequency
DC braking Braking current:0.0%~100.0%(rated current)
Braking time:0.0s~1000.0s
Jog control Jog frequency range:0.00Hz~Maximum frequency; Jog Accelerate time:0.0s~6500.0s
Simple PLC、Multi-speed Realize up to 16-speed operation through built-in PLC or control terminal
Inbuilt PID It is convenient to realize the process control closed-loop control system
Auto voltage regulation(AVR) When the grid voltage changes, it can automatically keep the output voltage constant
Overvoltage/over- Automatically limit current and voltage during operation to prevent frequent over-current and C3 EMC Filter Built-In
currentstall control
Rapid current limit Fast software and hardware current limiting technology to avoid frequent over-current faults of the inverter
Virtual IO Five virtual DO, five virtual DI, can realize simple logic control
Features
Timing Control Timing control function: setting time ranges:0.0Min~6500.0Min
Multi-motor switch Two groups of independent motor parameters can realize switching control of two motors
Applications
Bus support One independent MODBUS communication, one CAN communication, one Profibus-DP
Multi-encoder support Support differential, open-collector photoelectric encoder, resolver and other position sensors
Command Source Operation panel setting, control terminal setting, serial communication port setting. Can
be switched in many ways
10 kinds of frequency sources: no binding, digital setting, analog current setting (AI1/AI2),
Frequency source pulse setting (DI5),Multi-speed, simple PLC, PID, communication setting;
Can be switched in many ways
Running Auxiliary Frequency 10 kinds of auxiliary frequency sources. Flexible realization of auxiliary frequency fine-tuning and
source frequency synthesis
Standard configuration: 6 digital input terminals, one of which supports high-speed pulse input;
Input terminal 2 analog input terminals.Expansion capacity: 4 digital input terminals; 1 analog input terminal.
Standard configuration: 1 high-speed pulse output terminal; 1 digital output terminal; 2 relay output
Output terminal
terminals; 2 analog output terminals.Expansion capacity: 1 relay output terminal; 1 analog output terminal.
LED display Double LED display keyboard, more convenient to monitor parameters
Display and LCD display Optional, Chinese/English/Russian display function parameters and status information
Keypad Operation
Specification Copy The parameters can be quickly copied through the standard operation panel and optional LCD
The key lock and Realize partial or full lock of keys, define the scope of action of some keys, to prevent misoperation
function selection operation panel options
Protection Motor to ground short circuit detection, input and output phase loss protection, overcurrent protection,
Function Protection function overvoltage protection, undervoltage protection, overheating protection,Overload protection, etc.
Accessories Accessories Brake components, simple IO expansion card, multi-function IO expansion card, CAN communication
expansion card, differential input PG card,Resolver PG card