LT Exp 3
LT Exp 3
Front Interface of the Relay Conn. Diagram (TCS Model) * In TCS model : Remote Trip & Remote Block DI will not be available.
E10 B8
B7 B RS 485
u Circuit breaker failure protection B6
USB port for PC/ Battery Cover (Remove battery cover
Fault Reset Key
u Harmonic blocking (via DFT Filter) to avoid any unwanted tripping Laptop communication
(Manual Reset on
to change the appropriate battery)
pressing for 2 sec)
CSDPR-V2-30 u Last 5 Fault and 10 Event record with Time stamp
0-C2 Description A : This key is used to ON the LCD when available source is Aux Supply, CT current or USB port) Conn. Diagram (Standard Model without TCS)
u Wide operating ranges of the auxiliary supply voltage (AC/DC) Description B : This key is used to ON the LCD when available source is only Battery.
In TCS model : Remote Trip & Remote Block DI will not be available.
CSDPR-V2-300-C2
A13
u USB port for PC / Laptop interface L3
L1 L2 L3 E PICKUP TRIP* BLOCK CBFP A1 COM
DO-4
A2 NO
Latch
Aux Supply A3 COM
DO-3
current Protection Relay Design
P1 S1 E1
IL1
A4 NO
E2 A5
P2 S2 COM
DO-2
Relay will get energized from any of the following available sources:
Q RG
01 02 03 04
Battery changing Procedure (Photographs shown here for have an idea only)
Dimension Details (All the dim. are in mm, Gen. Tol.: + 1.0 mm) Back Terminal view CSDPR-V2 Series
Specification Table of the Relay
(TCS model)
Front View Side View Function ANSI CSDPR-V2-300-C2
3 Phase Over current protection 51 ü
136.75 104.0
14.0 E1
3 Phase Instantaneous protection 50 ü
A1 Latch IL1 Open the screw of Battery
A2 DO-4 E2 holder by using the appropriate Earth time Over Current 51 ü
Digital Output
CSDPR-V2-300-C2
A3 Latch
DO-3 screw driver Earth time Instantaneous Over Current 50 ü
A4 E3
A5 DO-2
IL2
Circuit Breaker Failure protection 50BF ü
With Aux
A6 supply
E4 Switch onto fault SOTF ü
A7 DO-1
A8
With Aux
supply
Trip circuit supervision * 74TC ü
Digital Input
E5
A9 DI-2
IL3
Fault Record -- 05
A10 DI-COM
A11 DI-1 E6 Event Record -- 10
A12
LCD Display -- 16x2 Alpha Numeric
186.5
158.0
Supply
A13 + E7
Aux
RS-485 COMM
TC-
TF-
E9
B A Digital Output -- ü
E10
Pulse Output -- ü
Powered Nature -- CT powered
B1 B2 B3 B4 B5 B6 B7
CSDPR-V2-300-C2
-- Aux. powered
Front Communication -- ü
R34STK000445
with Battery.
110.0 Panel cut out Dimension: HeightxWidth=160x112 without TCS)
Technical Data
100.0 E1
A1 IL1
General Data
Latch
Latch
DO-4
DO-4
A2 E2
Rated auxiliary Universal L: (18V - 60V DC)
Output
A3
DigitalOutput
Latch
Latch
DO-3
DO-3
CSDPR-V2 Series
A4 E3
A5 DO-2
DO-2 voltage UH H: (85V - 260V AC /
Digital
IL2
3.5
With
WithAux
Aux
A6 supply
supply
E4 Replace the prescribed 110V to 300V DC)
dia
E1
A7 DO-1
DO-1
A1
A2
Latch
DO-4 E2
I L1
A8
With
WithAux
supply
supply
Aux
1/2 AA size suitable battery Rated supply for Normal voltage U N L: (18V - 60V DC)
E5
Digital Input
Digital Input
A3 Latch A9 Remote
RemoteBlock
Block (DI-2)
(DI-2)
A4
DO-3
E3
A10 DI-COM
DI-Common
IL3 DI input H: (85V - 260V AC /
A5 DO-2 I L2 Relay E6
With Aux
A11 Remote Trip
Remote Trip (DI-1)
(DI-1)
110V to 300V DC)
160.00
A6 supply
E4
75.50
A8 supply
186.5
Supply
E5
A13 + E7 Power consumption
Digital Input
Aux
A9 DI-2 BLOCK
A10
I L3 Hole dia = 3.5mm A14 -
DI-COM
IE
A11
A12
DI-1 TRIP
E6
E8
of Aux supply Quiescent approx. 3W Operating approx. 6W
E7
Supply
A13 +
Dropout pickup ratio > 95 %
Aux
IE FLAG
FLAGTRIP COIL
42.25
A14 -
TC+
TF+
RS-485COMM
RS-485 COMM
TC-
TF-
E8 E9
B A
B A
FLAG TRIP COIL
RS-485 COMM E9 Close the Battery cover by
TC+
TF+
TC-
TF-
E10
B A
E10
twisting it on the right side
112.0 as shown in the Left image.
B1 B2 B3 B4 B5 B6 B7 B8
B1 B2 B3 B4 B5 B6 B7 Front (USB) Communication
120.0
R34STK000445
Front Port : CSE protocol with CSE LIVELINK on mini USB cable type A/A
05 06 07 08
Rear (RS-485) Communication Setting Inverse Graph Representation How to do Settings From Menu-1:
Inverse Time characteristics Two group of Protection Setting are available in CSDPR-V2 relay. User can select One On selecting GROUP SELECT by pressing ENTER
Parameter Display Setting Range Group as Active Group. For setting below are simple steps for configuration: key, user can change the active group by using # GROUP SELECT #
Slave Address SLV Add 1-32 ENTER and then scroll key.
Baud Rate BD Rate 9600/19200 Default Password for settings : “ 4-Times Enter Key” ACTIVE-GRP : GRP1
Parity Parity NONE/EVEN/ODD Default First Screen Press Enter and If the user selects the YES option ←BACK
MAIN DEFAULT SCREEN PAGE: then it will ask to enter the correct password or else to
The very first Screen of the HMI shows the Measured Primary Current for all the phases go to the previous menu by selecting the other
Measuring Input options by pressing ENTER key.
based on CT ratio.
Rated data Rated current I N (1A)
Frequency F N: 50/60 Hz L1 : 0000.0 A
VA Burden : (2.5VA @ Rated Current) L2 : 0000.0 A
From Menu-1:
<Menu 1> O n s e l e c t i n g # PROTECTION #
Thermal Withstand Capacity
(EDIT/VIEW PARAMETERS) PROTECTION by CTRatio : 0001 : CT Ratio for primary current display
Thermal withstand Continuously 2.5A pressing ENTER key.
Frequency : 50Hz : Frequency characteristic
capacity 10s 15A # EDIT/VIEW # User can see the list of
<GROUP SELECT > : For Active Group Selection of Parameter all the protection PhaseCh : DEFT : Phase over-current trip characteristic
for In=1A 1s 80A Press Key setting parameter by EarthCh : DEFT : Earth over-current trip characteristic
<PROTECTION > : Protection Related Parameter Menu using the scroll keys.
Accuracy <COLDLOAD PRT > : Cold Load Protection Menu l> : 0.20xIn : Over-current Pickup
Tripping times DMT : + 5% of the setting value or +40 mSec <FAULT RECORD > : Fault Record Menu Press ENTER to ti> : 0.01 : TMS Over-current Setting
with pre-fault IDMT : Accuracy as per IEC-255-3 (2xIs to 20xIs) <EVENT RECORD > : Event Record Menu select the desired t> : 0.1s : DEFT Trip Time
For VINV / NINV/RI : + 5% or + 40 mSec Parameter & use
<DO ASSGNMNT > : Programmable Relay Assignment Menu SCROLL keys to Edit l>> : 0.5xIn : Short Circuit Protection
For LINV/EINV/HV-Fuse : + 7.5% or + 60 mSec <DO RESET > : Programmable Relay Reset Menu the selected one.
By using t>> : 0.03 : DEFT Trip timing for SC Protection
Pickup accuracy +5% or +10mA <TRIP TYPE > : Trip Type
the Ie> : 0.05xIn : Earth Over-current Pickup
Boot-up time in < 100 mSec; (Event recorder enabled : 20mSec extra) If the user change any
scroll keys <RST TRIP CNT > : Reset Trip count Menu tie> : 0.01 : Inverse Trip Time
self powered mode of the setting, It is
select the <DISPLAY OPTN > : Display Options Menu
required to save the te> : 0.05s : DEFT Trip Time
Output Contact (Relay Specs) desired <BATTRY STATS > : Battery Status Menu changes by pressing Ie>> : 0.01xIn : Earth High-set Pickup
<TRIP TEST > : Output Trip Test Menu ENTER key and than
Number of relays 4 menu and selecting YES option, te>> : 0.05 : DEFT Trip timing Earth High
<COMMN SETTNG > : Communication RS485 Menu
DO contacts (DO: 1, 2) DO1 & DO2 are user programmable press after that entering the SOFTpk : DISABLE : SOTF pickup setting
configurable & available for I>, I>>, le> & Ie>>, CBFP, <LOAD DEFAULT > : Load Default Menu correct password to
ENTER. Unbalnc : 5% : Unbalance
only with Auxiliary supply Unbalance (U0>), Remote DI, all faults <DI BLOCKING * > : DI Blocking Menu save the setting or else
to go to the previous tUnblnc : 0.50s : Unbalance DEFT Trip Time
Relay contacts: 3, 4 Latch type of DO common for all <EDIT RTC > : Clock Setting Menu menu by selecting the
(available in all models) protection trip <CHNGE PSWORD > : Password Change Menu other options & by CBFP : YES : CBFP Supervision Time
Max. breaking capacity 1250VA / 150W resistive < FACTORY MODE > : Factory Setting Menu pressing ENTER key. tCBFP : 0.15s : CBFP Supervision Time
500VA / 90W inductive <RELAY VERSON > : Relay Version Menu td_TCS** : 2.00s : TCS Trip Time
Max. breaking voltage 400V AC, 125 VDC ←BACK
← BACK
Max. continuous AC current 5A
** For T model tdTCS, SOTFpk both will present and in S model instead of tdTCS will not present
Note : - * Menu Model Dependent FACTORY MODE Setting are not for the users.
09 10 11 12
13 14 15 16