0% found this document useful (0 votes)
62 views6 pages

Tapcon240 6 Pages

The TAPCON® 240 is a next-generation voltage regulator designed for regulating transformers, featuring a user-friendly interface and advanced functionalities for both simple and complex control tasks. It offers plug-and-play installation with a clear display, programmable inputs and outputs, and options for parallel control of transformers. Additional features include monitoring capabilities, measured value memory, and condition-based maintenance support for on-load tap-changers.

Uploaded by

Jean-Luc Masabo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views6 pages

Tapcon240 6 Pages

The TAPCON® 240 is a next-generation voltage regulator designed for regulating transformers, featuring a user-friendly interface and advanced functionalities for both simple and complex control tasks. It offers plug-and-play installation with a clear display, programmable inputs and outputs, and options for parallel control of transformers. Additional features include monitoring capabilities, measured value memory, and condition-based maintenance support for on-load tap-changers.

Uploaded by

Jean-Luc Masabo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

TAPCON® 240

www.reinhausen.com
Voltage Regulator
for Regulating Transformers
TAPCON® – The next generation of voltage regulators

TAPCON®: a name which is synonymous for an entirely new and


ground-breaking series of voltage regulators uniquely designed by
Maschinenfabrik Reinhausen (MR). Be it simple control tasks or com-
plex and sophisticated control systems (e. g. for phase-shifter trans-
formers) – the voltage regulators of the TAPCON® series are suitable
for all applications. Their chief caracteristic is ease of operation,
coupled with the degree of reliability typical of all MR products. The
development of this new product is based both on experiences gained
from the previous generation and on specific user requests. The prod-
uct’s elegant BLUE Line design will be an optical enhancement to
every control room.

Plug-and-play with NORMset

TAPCON® 240 is the 19” version of the new product family. Its clear,
well-arranged and large display (128 x 128 dot) makes commissioning
very easy. Thanks to the new standard function called NORMset, the
only thing to do for the user is to enter the voltage level and the volt-
age transformer ratio. The device takes care of all the rest. Needless to
say, parameterization can also be performed manually or via the
Windows based P.C. visualization software. Should input errors occur,
the reset-function shortly gives the factory preset parameter values.
The scope of equipment delivered

• Clear and well-arranged display • Freely programmable inputs and outputs


At a single glance: indication of mains voltage and on-load Certain inputs and outputs can be connected and/or assigned for
tapchanger position. No need for additorial displays in the switch- further processing by the customer, which saves wiring work.
ing cabinet.
• Easy extensions
• Rapid installation All modules are connected by a bus connection. This allows for
All cable leads are outfitted with plug connectors, which are simple retrofit and extension of additional functionalities.
directly connected to terminals inside the switching cabinet. Software updates are performed via parametering interfaces and
flash programming.
• Parallel control of transformers
– Parallel operation according to the principle of minimum circu-
lating reactive current or Master/Follower method.
– The implementation of a CAN-bus system allows parallel control,
in standard cases, of two groups featuring n participants without
an additional control device.
– One of the options available is system topology detection in a
mulitple bus bar system. In that case, the regulators will detect
automatically which of the transformers are engaged in parallel
operation. There is no need for an additional control device, too.
ACHTUNG !! Seite wird um 2cm auf 19cm verkürzt !!
Measured value memory (optional) Edit menue (with help text) TAPGUARD™ (optional)

The options

• (Cross) monitoring of a voltage regulator


By another voltage measuring input it will also be possible to
autonomously monitor a further voltage regulator.

• Serial interfaces to operation control system


In addition to communication protocols to all renowned manufac-
turers of operation control systems, we also provide protocols cor-
responding to IEC 60870-5-101 and IEC 60870-5-103.

• Measured value memory, record function


The time characteristic of a measuring-circuit voltage is recorded
in a separate measured value memory and can be recalled either
via display, or via P.C. using the visualization software.

• Second measurement input


For special applications, e. g. the regulation of three-winding
transformers, a second, electrically insulated measurement input
for power and voltage is available.

• TAPGUARD™
Condition-based maintenance of your MR on-load tap-changer
OILTAP®. Based on the variables, current and tap position present
in the voltage regulator, the equipment will calculate all the rele-
vant maintenance deadlines for your OLTC, thus helping to save
considerable maintenance costs for your OLTC.
TAPCON® 240: Setting ranges

Range

Desired voltage level 1 … 3 60 … 160 V


Bandwidth ±0.5 … ±9 %
Delay time T1 1 … 600 s
ACHTUNG !! Seite wird um 2cm auf 19cm verkürzt !!

Delay time T2 1 … 10 s
Switching pulse duration 1.5 s
LDC Ur = 0 … ±25 V
Ux = 0 … ±25 V
Z compensation selection Voltage rise 0 … 15 % of desired voltage level
Limitation 0 … 15 % of desired voltage level
Undervoltage blocking 60 … 100 % of desired voltage level
Overvoltage detection with 100 … 140 % of desired voltage level
high speed return control
(interruptible) Pulse signal 1.5 / 1.5 s
Overcurrent blocking 50 … 210 %
Voltage transformer 0.1 … 999.0 kV / 100 V
Current transformer 100 … 10.000 A / 5 / 1 / 0.2 A

TAPCON® 240: Operation elements, display

Function keys Manual / Automatic


Raise / Lower
Menu keys
Display Monochromatic display with graphics capabilities, 128 x 128 dot
1 LED lamp (green) for operating status
1 LED lamp (yellow) for signalling, ”parallel operation active“ status
1 LED lamp (red) each for signalling U<, U>, I>
1 LED lamp (green) for signalling ”NORMset active“ status
3 LED lamps (yellow) for random assignment
1 LED lamp (yellow / green / red) for random assignment

Power supply DC 36 … 72 V, 18 … 32 V on demand


AC/DC 88 … 265 V
Power consumption approx. 25 VA
Protective housing 19” rack
483 x 133 x 178 mm (W x H x D)
Degree of protection: IP OO according to IEC 60529
Weight approx. 5 kgs
Operating temperature - 25 … +70o C
Storage temperature - 35 … +80o C
© Maschinenfabrik Reinhausen GmbH Phone (+49) 9 41/40 90-0
www.reinhausen.com Falkensteinstrasse 8 Fax (+49) 9 41/40 90-600
93059 Regensburg, Germany E-mail: sales@reinhausen.com

Please note: The data in our publications may differ from the data of the devices delivered.
We reserve the right to make changes without notice.
IN215/05en – 0105/2000 – 215/05/01/0 – F0086204 · dp · Printed in Germany