0% found this document useful (0 votes)
25 views8 pages

Panel de Control

This document provides detailed information about replacement parts for Rotary Screw Liquid Chillers with microcomputer control centers, including part numbers and descriptions for various components. It outlines specific models and their applications, including both electro-mechanical and solid-state starter applications. Additionally, it includes notes on selecting replacement micro boards and EPROMs, as well as information on Chinese language display components.

Uploaded by

jairosopo1968
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views8 pages

Panel de Control

This document provides detailed information about replacement parts for Rotary Screw Liquid Chillers with microcomputer control centers, including part numbers and descriptions for various components. It outlines specific models and their applications, including both electro-mechanical and solid-state starter applications. Additionally, it includes notes on selecting replacement micro boards and EPROMs, as well as information on Chinese language display components.

Uploaded by

jairosopo1968
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

ROTARY SCREW LIQUID CHILLERS

RENEWAL PARTS Supersedes: 160.47-RP3 (292) Form 160.47-RP3 (599)

MICROCOMPUTER CONTROL CENTER

MODELS YS BA BA SO THRU YS FA FB S5 (STYLE A THRU D)


100 - 675 TONS

ELECTRO-MECHANICAL STARTER, SOLID STATE STARTER APPLICATIONS

25166A

26878A

PART NUMBERS
Style A English Display 371-01200-001
Style C English Display 371-01200-003
Style C English & Simplified Chinese 371-01200-006
Style C English & Traditional Chinese 371-01200-013
Style D English Display 371-01200-019
Style D English & Simplified Chinese 371-01200-020
Style D English & Traditional Chinese 371-01200-021
ITEM DESCRIPTION FIG. QTY. PART NUMBER
NO.
1 RELAY 1 1 024-23962-000
2 TRANSFORMER 1 1 025-27911-000
3 FUSE, 5 AMP 1 1 025-14019-000
4 FUSE, 15 AMP 1 1 025-14384-000
5 FUSE HOLDER 1 2 025-13991-000
6 CONTROL, MICRO BOARD 1 1 TABLE 1
7 CONTROL, POWER SUPPLY 1 1 031-01080-000
8 CONTROL, DIGITAL INPUT 1 1 031-00935-000
9 CONTROL, RELAY BOARD 1 1 031-00932-002
10 FASTENER, PAWL ADJ. 2 1 021-17252-000
11 KEYPAD (STANDARD) 2 1 024-25258-000
(Simplified Chinese Language) 5 1 024-27239-000
(Traditional Chinese Language) 5 1 024-27240-000
12 DISPLAY
CONTROL CENTER 371-01112-001 3, 4 1 031-00775-000(1)
CONTROL CENTER 371-01200-003 3, 4 1 031-00775-001(2)
13 SWITCH, ROCKER 2 1 024-23143-000
14 SUPPRESSOR 1 1 031-00808-000
15 NOT USED – – –––
16 NOT USED – – –––
17 NOT USED – – –––
18 CONTROL, CURRENT MODULE CM-2 3 1 031-00947-000
(Electro-Mechanical Starter Application Only)
19 DIODE BRIDGE 3 1 031-00210-000
(Electro-Mechanical Starter Application Only)
20 RESISTOR, VARIABLE 3 2 025-20789-000
(Electro-Mechanical Starter Application Only)
21 CONTROL, LOGIC - 7L (Solid State Starter Application Only) 4 1 031-00936-002
22 CONTROL, LOGIC - 14L (Solid State Starter Application Only) 4 1 031-00936-003
23 CONTROL, LOGIC - 26L (Solid State Starter Application Only) 4 1 031-00936-004
24 CONTROL, LOGIC - 33L (Solid State Starter Application Only) 4 1 031-00936-005
25 CONTROL, REMOTE RESET (Customer Option) 1 – 031-00814-000(3)
26 CARD FILE (Customer Option) 1 1 031-00827-000
27 IC, REAL TIME CLOCK - U16 1 1 031-00955-000
28 EPROM - U17 1 1 TABLE 2
29 SENSOR, WATER TEMP - 3K OHM – 2 025-29964-000
30 SENSOR, OIL & DISCHARGE TEMP - 50K OHM – 2 025-32328-000
31 PRESSURE TRANSDUCERS – – TABLE 3
32 CABLE, RIBBON - MICRO BOARD J4 1 1 031-00950-000
33 CABLE, RIBBON - RELAY BOARD J1 1 1 031-00951-000
34 CABLE, RIBBON - DISPLAY 1 1 031-00952-000
35 CABLE, RIBBON - DIGITAL INPUT BOARD J1 1 1 031-00953-000
36 CABLE, RIBBON - MICRO BOARD J2 1 1 031-00985-000
37 VOLTAGE TRANSIENT PROTECTION 1 1 031-01586-000
Module* for Micro Board RS-485 Serial Port (only used in units equipped
with ISN FAX-4500 BAS connected to RS-485 Serial Port TB-7)
* If this module is being installed for the first time, order kit #371-01477-000.
Kit includes module and Installation Instructions.
KIT, RETROFIT - SIMPLIFIED (Chinese Language Display) (also see Fig. 5) – – 371-01708-002
KIT, RETROFIT - TRADITIONAL (Chinese Language Display) (also see Fig. 5) – – 371-01708-005

For Notes, refer to page 3.

2 YORK INTERNATIONAL
FORM 160.47-RP3

NOTES:
1. BABCOCK VF-140-04. If not available, Kit 331-00775-600 will be supplied. Kit consists of Display 031-00775-001, Display Reset Board
031-01305-000 and Installation Instructions.
2. BABCOCK VF-140-02 or IEE 33383-01.
3. If it is desired to remotely reset both chilled water setpoint and current limit setpoint, two each are required. If it desired to remotely reset
only one of these setpoints, one each are required.
4. If Control Center is equipped with Micro Board 031-00940-001, transducer 025-28678-002 / -007 is used for both water and brine R22
applications and 025-28678-005 / -008 is not applicable.
5. Style “C” and later chillers use straight cut threads.

Replacement Micro Boards are supplied without Refer to Table 1 and order a replacement Micro Board
EPROMs. In some circumstances it will be necessary as follows:
to remove the EPROM from the defective board and
use it in the replacement board. In other circumstances,
1. In the left hand column of Table 1, locate the part
the available replacement board will not be compatible
number of the defective Micro Board and the part
with the existing EPROM and therefore, both board and
number of the EPROM installed in that board. In some
EPROM would have to be ordered.
cases, no EPROM part number is listed because the
EPROM will be removed from the defective board
Therefore, to select a replacement Micro Board that will
and used in the replacement board.
provide proper operation, it is essential that the part
number of the defective board and the part number of
the EPROM installed in that board are known prior to 2. Place an order for selection in right hand column. If
placing an order. The board part number is printed on an EPROM part number is listed in the right hand
the front surface of the board. The EPROM is component column, both the Micro Board part number and the
U17 on the Micro Board. Its part number is printed on a EPROM part number must be ordered. In other cases
label attached to the top surface of the EPROM. it is necessary to order only the Micro Board.

TABLE 1 –
IF EQUIPPED WITH SELECTION REPLACE WITH
MICRO BOARD / EPROM MICRO BOARD / EPROM
031-00940-001 / 031-01051-001 031-01065-002 / 031-01102-001 / NOTE 2
031-00940-001 / 031-01051-002 (1) 031-00940-001 / NOTE 1
031-01065-000, -001, -002 (1) 031-01065-002 / NOTE 1
NOTES:
1. Servicemen, in the field, must remove the EPROM from the defective Micro Board and re-use in the replacement board.
2. If brine cooling application, transducer 025-28678-003 / -009 must also be ordered to replace existing 025-28678-002 transducer.

TABLE 2 –
EPROM
APPLICATION APPLICABLE MICRO BOARD
PART NO. VERSION
031-01051-001 4.E STANDARD CHILLER 031-00940-001
031-01051-002 4.EF YORK FAX-4000 031-00940-001
031-01102-002 S.01F.17 YORK FAX-4500 AND STANDARD 031-01065-000; -001; -002

TABLE 3 –
PART NUMBER
PRESSURE TRANSDUCERS THREAD TYPE
NPTF STRAIGHT CUT(5)
CONDENSER, OIL, FILTER OIL & SEAL OIL 025-28678-001 025-28678-006
EVAPORATOR - R22, WATER 025-28678-002(4) 025-28678-007(4)
R22, BRINE 025-28678-003 025-28678-009
R134a, WATER & BRINE 025-28678-005 025-28678-008
(4), (5) Refer to notes above.

YORK INTERNATIONAL 3
26 (LOCATION OF
36 27 28 37 25 (OPTIONAL) OPTIONAL CARD FILE)

32
7

34

3, 5

4, 5

25169A

35 8 33 9 14 1

FIG. 1 – MICROCOMPUTER CONTROL CENTER – DOOR AND HINGED PANEL OPEN

11

10

13

25167A

FIG. 2 – MICROCOMPUTER CONTROL CENTER EXTERIOR

4 YORK INTERNATIONAL
FORM 160.47-RP3

12 18

24676A

19 20

FIG. 3 – MICROCOMPUTER CONTROL CENTER – DOOR OPEN


ELECTRO-MECHANICAL STARTER APPLICATIONS

21 - MODEL - 7L
22 - MODEL - 14L
23 - MODEL - 28L
12 24 - MODEL - 33L

24670A

FIG. 4 – MICROCOMPUTER CONTROL CENTER – DOOR OPEN


ELECTRO-SOLID STATE STARTER APPLICATIONS

YORK INTERNATIONAL 5
2

28498AC

6 7 1 4

28499A

3 (Not Shown)

FIG. 5 – CHINESE LANGUAGE DISPLAY COMPONENTS

6 YORK INTERNATIONAL
FORM 160.47-RP3

ITEM DESCRIPTION PART NO.


1 PC BOARD, CHINESE LANGUAGE DISPLAY 031-01616-000
2 DISPLAY, CHINESE LANGUAGE LCD GRAPHIC 031-01653-000
3 TRANSFORMER, CHINESE LANGUAGE DISPLAY 115VAC / 24VAC 025-27911-000
4 CABLE, RIBBON – MICRO BOARD TO CHINESE LANGUAGE DISPLAY 031-01647-000
5 CABLE, RIBBON – CHINESE DISPLAY BOARD TO VACUUM FLUORESCENT DISPLAY 031-01646-000
6 CABLE, RIBBON – CHINESE DISPLAY BOARD TO CHINESE LANGUAGE LCD DISPLAY 031-01645-000
7 EPROM – CS.01F.00 (IC-U13) YS – SIMPLIFIED CHINESE LANGUAGE 031-01639-001*
8 EPROM – CS.01F.00 (IC-U14) YS – TRADITIONAL CHINESE LANGUAGE 031-01639-002*
* See Notes below.

NOTES FOR FIGURE 5

Beginning on / about April 1997, Chinese language displays will be supplied with either: two Simplified translation
EPROMs or two Traditional translation EPROMs. If Simplified translation is desired, both of the Simplified EPROMs
below are required. If Traditional translation is desired, both of the Traditional EPROMs below are required. The
EPROM part numbers and on-board socket locations are as follows:

EPROM TRANSLATION SOCKET LOCATION


031-01699-001 Simplified U13
031-01699-002 Simplified U14
031-01699-003 Traditional U13
031-01699-004 Traditional U14

Chinese Language displays contained one EPROM (031-01639-001) (socket location U13) that translated to Sim-
plified Chinese and one EPROM (031-01639-002) (socket location U14) that translated to Traditional Chinese. The
desired translation was then selected by Program Jumper PT0, located on the Chinese language display board.
Due to the addition of messages, two EPROMs are now required for each translation as described above. When
equipped with these new EPROMs, Program Jumper PT0 can no longer be used to select between Simplified or
Traditional translation. If one of these earlier version EPROMs listed in Fig. 5 fails, it must be replaced with two
EPROMs as follows:

IF THIS EPROM FAILS: REPLACE WITH:


PART NO. LOCATION TRANSLATION PART NO. LOCATION
031-01699-001 U13
031-01639-001 U13 SIMPLIFIED - and -
031-01699-002 U14
031-01699-003 U13
031-01639-002 U14 TRADITIONAL - and -
031-01699-004 U14

YORK INTERNATIONAL 7
P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA
Copyright © by York International Corporation 1999 ALL RIGHTS RESERVED