P012... B P016... B P020... B: Strawinskylaan 1105 1077 XX Amsterdam, The Netherlands
P012... B P016... B P020... B: Strawinskylaan 1105 1077 XX Amsterdam, The Netherlands
2021
Rev. 1
Strawinskylaan 1105 EN
1077 XX Amsterdam, The Netherlands instruction manual
P012...B
P016...B
P020...B
PHOENIX CAM SWITCHES WITH TYPE “B” BASE
MOUNTING (12 A / 16 A / 20 A)
CODE READING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Before use, read this booklet carefully to
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 acquaint yourself with the features of the
product. This booklet is an integral part of
OVERALL DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
the product and therefore must be kept until
ELECTRICAL SCHEMES . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 the product is dismissed.
ACTUATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Giovenzana International B.V. reserves the
MOUNTING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . 8 right to change the features and data shown
in this document at any time and without
notice. This document cannot therefore be
considered a contract with third parties.
P0 and PX series cam switches are
ATTENTION
Before any installation or maintenance operation, designed and manufactured according to
disconnect the power supply to the system. IEC international standard and EN European
Before restoring the power supply, make sure that regulations.
all connections to the device have been made
correctly. Giovenzana International B.V. disclaims
Any improper installation or any tampering
any responsibility for any damage to things and of the device may cause serious personnel
people caused by non-compliance with the rules injury or property damage, therefore, the
described here. installation and maintenance must be
performed by specialized and authorized
personnel.
The use of this device is not allowed in
environment with a potentially explosive
atmosphere or in presence of corrosive
substances and in salt spray.
P012...B 12 A 10 A
P016...B Base IP20 16 A 14 A
P020...B 20 A 16 A
Read the page with the code reading for further useful information on the product in your possession. This instruction
manual illustrates features and procedures relating to the products in the Giovenzana catalog. The specifications on
p.2 and the mounting instructions on p.8, and following, are also valid for custom products derived from one of
the series illustrated in this manual.
1 / 16
CODE READING
SPECIFICATIONS
General characteristics
Protection class control EN 60529 IP65
UL50 / NEMA Type 1 - 4 - 4X
terminals IP20
Connectable section flexible conductors 1 × 0.75 ... 4 mm² or 2 × 0.75 ... 2.5 mm²
AWG 18 ... 10
Alternate current
Rated operating current Ie P012... P016... P020...
Direct current
Rated operating current Ie P012... P016... P020...
Rated short-time short circuit withstand current (1 s) lcw 300 A 300 A 300 A
UL 508 characteristics
P012... P016... P020...
Standard motor load 1 phase - 2 poles 120 V AC 0.5 HP 9.8 FLA 1 HP 16 FLA 1.5 HP 20 FLA
240 V AC 1 HP 8 FLA 1.5 HP 10 FLA 2 HP 12 FLA
3 phases - 3 poles 200 V AC 1.5 HP 6.9 FLA 3 HP 11.04 FLA 5 HP 17.5 FLA
240 V AC 3 HP 9.6 FLA 5 HP 15.2 FLA 5 HP 15.2 FLA
480 V AC 5 HP 7.6 FLA 7.5 HP 11 FLA 10 HP 14 FLA
600 V AC 5 HP 6.1 FLA 7.5 HP 9 FLA 10 HP 11 FLA
Marking
Approved
Ø 4.5
57
69
(E)
(A)
28 10 12.7 14.7 26.5 44
(E)
Terminal
protection class
IP20 Dimensions in mm
1.5 L1
Illustrations NOT in scale
L2
Examples:
N. of wafers 1 2 3 4 5 6
L1 [mm] 37.4 50.1 62.8 75.5 88.2 100.9
L2 [mm] 63.9 76.6 89.3 102 114.7 127.4
Please note
1 3 1 3 5 2 4 2 4 6 8
2 4 2 4 6 1 1 5
2
5-6 ×
3-4 × 3-4 × 7-8 ×
1 1 2
1-2 × 1-2 × 5-6 ×
1 3 5 7 1 3 5 7 9 11 2 4 6 8 10 12 2 4 6 8 10 12 14 16
2 4 6 8 2 4 6 8 10 12 1 5 9 1 5 9 13
11-12 × 15-16 ×
3 4
9-10 × 13-14 ×
W Wafers
CNT Contacts
Grey/Black Yellow/Red
48×48
48×48 padlock in 0
48
components (A2 - B2).
The reference pins orientation
(A3 - B3) and the orientation
48 30.2 of the shaft (A4 - B4), change
accordingly.
panel
thickness:
1 ... 4 mm
Ø 17
3.2 × 13
Ø 3.5
Ø 17
Ø 3.5
(A3) reference (B3)
(B2) pins
(B1) distance
orientation
32 between fixing
holes: 32 mm
CLICK!
48
orientation (A3 - B3) and the
orientation of the shaft (A4 - B4),
change accordingly.
48 35.2 Padlocking is possible only with
the cam-switch in OFF position
(A4 - B4) with the door unlocked.
panel ATTENTION: padlocking does not
thickness: lock the door but prevents any
1 ... 4 mm operation on the handle.
Ø 17
3.2 × 13
Ø 3.5
(A1)
(A2) distance shackle:
between fixing 3 × 9.5
28 6 mm max
holes: 28 mm
Ø 17
Ø 3.5
(A3) reference (B3)
(B1)
pins
(B2) distance
orientation
32 between fixing
holes: 32 mm
CLICK!
48
48 30.2
panel
thickness:
1 ... 4 mm
3.2
24
22.5
cam-switch
OFF ON
door door
unlocked locked
CLICK!
48
48 35.2
panel
thickness:
1 ... 4 mm
3.2
shackle:
24
6 mm max
22.5
cam-switch
OFF ON
Padlocking is possible only with the cam-switch in OFF
position with the door unlocked.
ATTENTION: padlocking does not lock the door but
prevents any operation on the handle.
door door
unlocked locked
Mounting
CLICK!
67
B2). The reference pins orientation
(A3 - B3) and the orientation
of the shaft (A4 - B4), change
accordingly.
67 29.9 Padlocking is possible only with
the cam-switch in OFF position
panel (A4 - B4) with the door unlocked.
thickness: ATTENTION: padlocking does not
1 ... 4 mm lock the door but prevents any
operation on the handle.
Ø 17
up to 3
M3 × 12
padlocks
Ø 3.5
shackle:
8 mm max
(A1) distance (A2)
28 between fixing
holes: 28 mm
Ø 17
reference pins
Ø 3.5 orientation 3 × 9.5
CLICK!
67
67 29.9
panel
thickness:
1 ... 4 mm
Padlocking is possible
3.2 only in OFF position
up to 3 padlocks
24
shackle: 8 mm max
22.5
cam-switch
OFF ON
Padlocking is possible only with the cam-switch in OFF
position with the door unlocked.
ATTENTION: padlocking does not lock the door but
prevents any operation on the handle.
door door
unlocked locked
CLICK!