FORM NO.
: 10
                                      (Prescribed under rule 60)
           Prescribed for report Examination of the lifting machines, ropes and lifting tackles.
Report No.: RCIPL/AMNS/MECPL/DEC-24/001                                                      Date : 06/12/2024
1. Name of occupier of factory                       :   Mesuka Eng. Co. Pvt Ltd.
2. Address of factory                                :   Site : 27 KM Surat-Hazira Road, Hazira, Surat.
3. Distinguishing number of mark (if any) and        :   Lifting Hook
   description sufficient to identify the lifting        Id No.: LH/15
   machine, chain, rope or the lifting tackle.           SWL Capacity: 6 Ton
                                                         Length of Plate : 555mm, Hook Eye Inside Dia :
                                                         54mm, Hook Thickness : 32mm, Height : 300mm,
                                                         Plate Eye Inside Dia : 40mm
                                                         Location: CRM-2 (AM / NS)
4. Date when the lifting machine, chain, rope or     :   Not Known
   lifting tackle was first used in the factory.
5. Date of each examination made under section :         Thorough inspection carried out on 06/12/2024 by
   29(1)(a)(iii) and by whom it was carried out.         BRIJESH NAIK Competent Person. (Load test at
                                                         1.25 Times of SWL)
6. Date and number of the certificate relating to :      Not Available
   any test examination made under sub- rule (1)
   of Rule 60 together with the name of the
   person who issued the certificate.
7. Date of annealing or other heat treatment if the : Not Applicable as per sub rule 6 of rule 60.
   chain and lifing tackle carried out under
   sub-rule(5) of Rule 60 and by whom it was
   carried out.
8. Particulars of any defect found at any such       : No defects noticed. Safe to use at SWL Capacity.
   examination or after annealing and affecting
   the safe working load and the steps taken to
   remady such defect.
I certify that on 06/12/2024 , I have thoroughly examined the above mentioned lifting Machine/Chain/
Rope/Lifting tackle and that the above is correct report of the result.
Signature                               __________________
Name of the Competent Person          : BRIJESH NAIK
Qualification                         : BE MECHANICAL
                                        ANST LEVEL II IN UT, RT, PT, MPT
Competency Certificate No.            : GUJ/DISH/CPT/A/1166/2023 VALID UP TO 28/04/2025.
Issued By                             : Director, Industrial Safety & Health, Gujarat State, Ahmedabad
Next Inspection Due on : 05/12/2025
                                            FORM NO. : 10
                                      (Prescribed under rule 60)
           Prescribed for report Examination of the lifting machines, ropes and lifting tackles.
Report No.: RCIPL/AMNS/MECPL/DEC-24/002                                                      Date : 06/12/2024
1. Name of occupier of factory                       :   Mesuka Eng. Co. Pvt Ltd.
2. Address of factory                                :   Site : 27 KM Surat-Hazira Road, Hazira, Surat.
3. Distinguishing number of mark (if any) and        :   Lifting Hook
   description sufficient to identify the lifting        Id No.: LH/16
   machine, chain, rope or the lifting tackle.           SWL Capacity: 6 Ton
                                                         Length of Plate : 555mm, Hook Eye Inside Dia :
                                                         54mm, Hook Thickness : 32mm, Height : 300mm,
                                                         Plate Eye Inside Dia : 40mm
                                                         Location: CRM-2 (AM / NS)
4. Date when the lifting machine, chain, rope or     :   Not Known
   lifting tackle was first used in the factory.
5. Date of each examination made under section :         Thorough inspection carried out on 06/12/2024 by
   29(1)(a)(iii) and by whom it was carried out.         BRIJESH NAIK Competent Person. (Load test at
                                                         1.25 Times of SWL)
6. Date and number of the certificate relating to :      Not Available
   any test examination made under sub- rule (1)
   of Rule 60 together with the name of the
   person who issued the certificate.
7. Date of annealing or other heat treatment if the : Not Applicable as per sub rule 6 of rule 60.
   chain and lifing tackle carried out under
   sub-rule(5) of Rule 60 and by whom it was
   carried out.
8. Particulars of any defect found at any such       : No defects noticed. Safe to use at SWL Capacity.
   examination or after annealing and affecting
   the safe working load and the steps taken to
   remady such defect.
I certify that on 06/12/2024 , I have thoroughly examined the above mentioned lifting Machine/Chain/
Rope/Lifting tackle and that the above is correct report of the result.
Signature                               __________________
Name of the Competent Person          : BRIJESH NAIK
Qualification                         : BE MECHANICAL
                                        ANST LEVEL II IN UT, RT, PT, MPT
Competency Certificate No.            : GUJ/DISH/CPT/A/1166/2023 VALID UP TO 28/04/2025.
Issued By                             : Director, Industrial Safety & Health, Gujarat State, Ahmedabad
Next Inspection Due on : 05/12/2025