Oil Free Screw: Single Stage / Two Stage
Oil Free Screw: Single Stage / Two Stage
15-55 kW Single-Stage
Vtype
Fixed Speed
Air-Cooled
Without Dryer
22-120kW Two-Stage
Vtype
Fixed Speed
Air-Cooled
MPa: 0.70/0.88/0.93/1.0 Water-Cooled
Without Dryer
132-240kW Two-Stage
Vtype
Fixed Speed
Air-Cooled
MPa: 0.75/0.93/1.0 Water-Cooled
m3/min: 19.0 - 40.5 Without Dryer
1
OIL FREE SCREW (DSP) Model List
Fixed Speed Type
Nominal Output (kW)
Model
15 22 30 37 45 55 75 90 100 120 132 145 160 200 240
Built-in Dryer
Air-Cooled
Single-Stage Without Dryer
Built-in Dryer
Air-Cooled
Without Dryer
Two-Stage
Built-in Dryer
Water-Cooled
Without Dryer
Vtype
Nominal Output (kW)
Model
15 22 30 37 45 55 75 90 100 120 132 145 160 200 240
Built-in Dryer
Air-Cooled
Single-Stage Without Dryer
Water-Cooled Without Dryer
Built-in Dryer
Air-Cooled
Without Dryer
Two-Stage
Built-in Dryer
Water-Cooled
Without Dryer
2
DSP Common Features
Reliability at
45°C PQ
Vtype Vtype
Condition: 0.60
• Model:DSP-37VATN2 98 Air consumption
• Control pressure: @60% Constant pressure
0.70MPa 96
control range
• Use point pressure at full 94 7.2 %
load: 0.55MPa energy saving General variable speed model Pressure drop
0
ECO-MODE
IPC-OFF IPC-ON
(Energy-saving operation control) Fixed Speed
*Use point pressure is changed according to working condition because of predicted
control. Automatically reduces the cut-out pressure according to the load ratio.
This eliminates wasteful pressure boosting and realizes energy-saving
operation.
(Starting unload)
Cut-in pressure
(Starting load) Load Unload time
3
Vtype
User-friendly operation interface Fixed Speed
USB Flash Memory Possible for Data Logging USB flash memory (data retrieving)
(Standard) pressure/temperature/current/history/time
*Necessary to prepare a USB flash memory device (5.5cm or smaller) on user’s side.
*Operation data for one day is approximately 400kB. (For reference)
Modbus® Communication
Bluetooth® Dongle Tablet terminal device
Open network serial communication
Modbus®/RTU is
supported as standard Color Touch Screen
*Modbus®/TCP support is optional. USB connector
LAN (Modbus®/TCP
Bluetooth is the registered trademark of Bluetooth SIG, Inc (US).
Modbus is the registered trademark of Schneider Automation Inc. (The image is modified)
4
Single-Stage (15-55kW)
Operation Interface
Airend
Inverter
Gear Case
Main Motor
Control Panel
100 100
Cut Down Overhaul and Initial Cost
DSP single-stage has only one airend inside. It makes its
50 50
initial cost much lower than two-stage model.
The overhaul cost, which covers the most of maintenance
cost, is about 60% of Two-Stage for the same reason. 0 0
Single-Stage Two-Stage Single-Stage Two-Stage
Comparison of Comparison of
Overhaul Cost (%) Initial Cost (%)
Example of Hitachi 55kW (Single-Stage) and 45kW (Two-Stage), Without Dryer model
(Calculated value)
5
Specifications
Air-Cooled, Fixed Speed Model (15−55kW) : Indicates model with Dryer integrated.
Model DSP-15A R 5N2 DSP-22A R 5N2 DSP-37A R 5N2 DSP-55A R 5N2
Item Unit DSP-15A R 6N2 DSP-22A R 6N2 DSP-37A R 6N2 DSP-55A R 6N2
Discharge Pressure MPa 0.70 0.40 0.70 0.40 0.70 0.40 0.70 0.40
Discharge Air Capacity m3/min 2.0 2.5 3.4 4.0 5.0 5.9 6.4 8.0
Nominal Output kW 15 22 37 55
Intake Air Pressure / Temperature - Atmospheric Pressure / 0 – 45˚C2 – 45˚C
Discharge Air Temperature ˚C Ambient Temperature +15 or below
Discharge Pipe Diameter - Rc1 Rc1-1/2
Starting Method - Direct On-Line Star-Delta (3 contactors)
Driving Method - 4-Pole TEFC Motor with V-Belt + Gear Driving
Lubricating Oil Capacity L 12 (Not filled) 18 (Not filled)
Cooling Fan Motor Output kW 0.4 0.65 0.9
Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3
P.D.P ˚C 10 (Under Pressure) − 10 (Under Pressure) − 10 (Under Pressure) − 10 (Under Pressure) −
Dryer Refrigerator Nominal Output kW 0.5 − 1.2 − 1.45 − 1.45 −
Refrigerant - R407C − R410A − R410A − R410A −
Weight kg 770800 850910 1,0801,230 1,3301,480
Dimensions (W×D×H) mm 1,400×970×1,400 1,830×980×1,5802,230×980×1,580
Noise Level (1.5m from front side) dB(A) 62 63 63 64 66 68 68 70
Air-Cooled / Water-Cooled, Vtype Model (22−55kW) : Indicates model with Dryer integrated.
Model DSP-22VA R 5N2 DSP-37VA R 5N2 DSP-55VA R 5N2
DSP-37VWN2 DSP-55VWN2
Item Unit DSP-22VA R 6N2 DSP-37VA R 6N2 DSP-55VA R 6N2
Cooling Method - Air-Cooled Water-Cooled
Discharge Pressure MPa 0.70 0.30 0.70 0.30 0.70 0.30 0.70 0.30 0.70 0.30
Discharge Air Capacity m /min
3
3.4 4.6 5.0 6.7 6.4 8.5 5.0 6.7 6.4 8.5
Discharge Pressure MPa 0.60 − 0.60 − 0.60 − 0.60 − 0.60 −
PQ Discharge Air Capacity m3/min 3.7 − 5.5 − 7.0 − 5.5 − 7.0 −
WIDEMODE Discharge Pressure MPa 0.400.50 − 0.400.50 − 0.400.50 − 0.40 − 0.40 −
Discharge Air Capacity m3/min 4.34.0 − 6.46.0 − 8.27.6 − 6.4 − 8.2 −
0.40 – 0.70 0.40 – 0.70 0.40 – 0.70
PQ WIDEMODE Range MPa − − − 0.40 – 0.70 – 0.40 – 0.70 –
0.50 – 0.70 0.50 – 0.70 0.50 – 0.70
Nominal Output kW 22 37 55 37 55
Intake Air Pressure / Temperature - Atmospheric Pressure / 0 – 45˚C2 – 45˚C Atmospheric Pressure / 0 – 45˚C
Discharge Air Temperature ˚C Ambient Temperature +15 or below Cooling Water Temperature +13 or below
Discharge Pipe Diameter - Rc1-1/2 Rc1-1/2
Starting Method - Inverter Inverter
Driving Method - 4-Pole TEFC Motor with V-Belt + Gear Driving 4-Pole TEFC Motor with V-Belt + Gear Driving
Lubricating Oil Capacity L 12 (Not filled) 18 (Not filled) 14 (Not filled)
Cooling Fan Motor Output kW 0.65 0.9 0.2
Cooling Water Flow Rate L/min − 80
Cooling Water Temperature ˚C − 32 or below
Cooling Water Pipe Diameter - − Rc1
Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3 −
10 (Under 10 (Under 10 (Under
P.D.P ˚C − − − −
Pressure) Pressure) Pressure)
Dryer
Refrigerator Nominal Output kW 1.2 − 1.45 − 1.45 − −
Refrigerant - R410A − R410A − R410A − −
Weight kg 900960 1,1401,290 1,2701,420 1,110 1,240
Dimensions (W×D×H) mm 1,650×970×1,400 1,830×980×1,5802,230×980×1,580 1,830×980×1,580
Noise Level (1.5m from front side) dB(A) 63 64 66 68 68 70 64 66 64 66
6
Two-Stage (22–120kW)
Specifications
Water-Cooled, Fixed Speed / Vtype Model (45-75kW) : Indicates model with Dryer integrated.
NOTE: 7. Earth leakage breaker is not built in the compressor. Prepare by customer.
1. Capacity is measured according to ISO 1217, Annex C. 8. Do not use the respiratory equipment to suck the compressed air directly.
2. Nominal output is a numerical value for the rough compressor capacity. Refer to installation 9. Discharge pressure is gauge pressure.
drawings when you plan the compressor shaft power, installed motor output, and power 10. Install the air compressor indoors and avoid flammable and corrosive environment, moisture
supply equipment. and dust.
3. Noise level is the converted value in an anechoic room measured under the condition that at 11. Dimensions do not include the pipes and protruding parts. Refer to the drawing for more
full load running operation at 1.5m in front and 1m in height, the timing of the closure of cooler details.
drain automatic discharge valve. It could be larger depending on the actual installation and its 12. Appearance and specifications are subject to change without notice.
environment.It is not a guaranteed value. It could increase by approx. 2dB when PQ
WIDEMODE is ON.
4. P. D. P (Pressure Dew Point) of a built-in dryer model is measured in ambient temperature 30
˚C, inlet temperature 45 ˚C, and under the rated pressure. For the built-in dryer model, P. D. P D S P - 75 V A T R 5 N2
drops at lower operating pressure. When the PQ wide mode is ON and the pressure is 0.7 MPa
Dry DSP
or less, the outlet P. D. P increases by approx. 3°C at 0.6MPa.
Screw Frequency (5:50Hz, 6:60Hz)
5. Discharged air capacity of a built-in dryer model decreases by approximately 3% when drain
Package R:Built-in Dryer (Without R:Without Dryer type)
condenses.
Nominal Output (kW) Two-stage (Without “T” description for 90-120kW)
6. In case of dust-proof or package filter option, maximum ambient temperature is limited up to
V:Vtype (Without V:Fixed Speed Model) A:Air-Cooled, W:Water-Cooled
40˚C.
7
Specifications
Air-Cooled, Fixed Speed / Vtype Model (22-37kW) : Indicates model with Dryer integrated.
Air-Cooled, Fixed Speed / Vtype Model (45-75kW) : Indicates model with Dryer integrated.
NOTE: 5. Discharged air capacity of a built-in dryer model decreases by approximately 3% when drain
1. Capacity is measured according to ISO 1217, Annex C. condenses.
2. Nominal output is a numerical value for the rough compressor capacity. Refer to installation 6. In case of dust-proof or package filter option, maximum ambient temperature is limited up to
drawings when you plan the compressor shaft power, installed motor output, and power 40˚C.
supply equipment. 7. Earth leakage breaker is not built in the compressor. Prepare by customer.
3. Noise level is the converted value in an anechoic room measured under the condition that at 8. Do not use the respiratory equipment to suck the compressed air directly.
full load running operation at 1.5m in front and 1m in height, the timing of the closure of cooler 9. Discharge pressure is gauge pressure.
drain automatic discharge valve. It could be larger depending on the actual installation and its 10. Install the air compressor indoors and avoid flammable and corrosive environment, moisture
environment.It is not a guaranteed value. It could increase by approx. 2dB when PQ and dust.
WIDEMODE is ON. 11. Dimensions do not include the pipes and protruding parts. Refer to the drawing for more
4. P. D. P (Pressure Dew Point) of a built-in dryer model is measured in ambient temperature 30 details.
˚C, inlet temperature 45 ˚C, and under the rated pressure. For the built-in dryer model, P. D. P 12. Appearance and specifications are subject to change without notice.
drops at lower operating pressure. When the PQ wide mode is ON and the pressure is 0.7
MPa or less, the outlet P. D. P increases by approx. 3°C at 0.6MPa.
8
Two-Stage (132-240kW)
Aftercooler
Air Intake Filter
Starter Panel
Inverter
Airend (1st Stage)
Airend
(2nd Stage)
Gear Case
TEFC Motor
Oil Cooler
The above picture shows the internal structure of
240kW Water-Cooled model (Vtype).
(up to 1.0MPa) Compared to conventional Load/Unload Control Type, lower pressure setting is possible
due to the stable pressure control. (Calculated value)
Hi-precooler system (Air-Cooled models) Ventilating fan Air exhaust Hi-precooler cool down the
internal temperature between
Hi-precooler system reduces temperature of extremely hot air to 160˚C—180˚C
aftercooler and Two-Stage cooling structure improves reliability.
1st Stage Hi-precooler
High Discharge Pressure Available Airend Two-Stage
cooling
structure
1.0MPa is available with high reliability. Intercooler
Aftercooler
9
Specifications
Air-Cooled, Fixed Speed Model (132-240kW)
Model DSP-132A5N2 DSP-145A5N2 DSP-160A5N2 DSP-200A5N2 DSP-240A5N2
Item Unit DSP-132A6N2 DSP-145A6N2 DSP-160A6N2 DSP-200A6N2 DSP-240A6N2
Discharge Pressure MPa 0.75 0.93 1.0 0.75 0.93 1.0 0.75 0.93 1.0 0.75 0.93 1.0 0.75 0.93 1.0
Discharge Air Capacity m3/min 22.5 20.0 19.0 25.0 21.4 20.0 27.5 23.9 22.5 37.0 32.2 30.0 40.0 35.0 32.5
Nominal Output kW 132 145 160 200 240
Intake Air Pressure / Temperature - Atmospheric Pressure / 0 - 45˚C
Discharge Air Temperature ˚C Ambient Temperature 15 or below
Discharge Air Pipe Diameter - 2-1/2 in (Flange) 3 in (Flange)
Starting Method - Star-Delta (3 contactors)
Driving Method - 4-Pole TEFC motor with Direct Connection + Gear Driving
Lubricating Oil Capacity L 50 (Not filled) 60 (Not filled)
Cooling Fan Motor Output kW 4.4 1.1×4 6.0 1.5×4
Weight kg 3,860 3,960 5,000
Dimensions (W×D×H) mm 2,900×1,700×1,925 3,200×1,890×1,950
Noise Level (1.5m from front side) dB(A) 73 74 74 75 74 75 76 77 77 78
NOTE:
1. Capacity is measured according to ISO 1217, Annex C. 5. Do not use the respiratory equipment to suck the compressed air directly.
2. Nominal output is a numerical value for the rough compressor capacity. Refer to installation 6. Discharge pressure is gauge pressure.
drawings when you plan the compressor shaft power, installed motor output, and power 7. Install the air compressor indoors and avoid flammable and corrosive environment, moisture
supply equipment. and dust.
3. Noise level is the converted value in an anechoic room measured under the condition that at 8. Dimensions do not include the pipes and protruding parts. Refer to the drawing for more
full load running operation at 1.5m in front and 1m in height, the timing of the closure of cooler details.
drain automatic discharge valve. It could be larger depending on the actual installation and its 9. Appearance and specifications are subject to change without notice.
environment.It is not a guaranteed value. 10. The inverter panel for air-cooled Vtype is placed separately.
4. Earth leakage breaker is not built in the compressor. Prepare by customer.
10
Auxiliary Equipment
Air Dryer
HDR series
Specifications
Model HDR-75AX
HDR-7.5AX2 HDR-15AG1 HDR-22AG1 HDR-37AG1 HDR-55AX HDR-100AX
Item Unit
Capacity (Note 1) 50/60Hz m3/min 1.3/1.4 3.0/3.4 4.9/5.4 7.9/8.4 10.8/11.3 15.0/15.7 19.0/20.0
Max. Inlet Pressure of Compressed Air MPa 0.3 – 0.97 0.3 – 1.0 0.4 – 0.97
Max. Inlet Temperature of Compressed Air 80
Ambient Temperature 5 – 40 2 – 45 5 – 40
Dew Point of Outlet Air 10 Under Pressure
Cooling Method of Condenser - Air-Cooled
Refrigerant Control Device - Capillary Tube Ejector
Capacity Control Device - Hot Gas Bypass Valve
Refrigerant Used - R407C R410A R407C
Charged Quantity 250 450 680 1,000 1,650 2,000
Finish Color - Ivory Gray Ivory
Pipe Diameter - Rc 1 Rc 11/2 Rc 2 Rc 21/2
Dimensions (W×D×H) mm 303×603×720 303×633×840 356×543×1,067 356×543×1,274 356×903×1,274 356×903×1,489 406×1,400×1,380
Weight kg 43 60 84 107 135 170 280
Accessories - Auto Drain Trap, Drain Valve, Foundation Bolts
NOTE:
1. The capacity values above are measured at an ambient temperature of 30˚C, inlet temperature of 45˚C, inlet pressure of 0.70MPa.
2. Dew point gets worse if operated at pressure below the range of operation pressure.
3. Dimensions do not include the pipes and protruding parts. Refer to the drawing for more details.
4. In case of having solid objects such as rust in the inlet air flow, install a pre-filter on the inlet of dryer.
Model
Item Unit HDR-120WX HDR-150WX HDR-190WX HDR-240WX HDR-300WX HDR-380WX HDR-120AX HDR-150AX HDR-190AX HDR-240AX HDR-300AX HDR-380AX
Capacity (Note 1) 50/60Hz m3/min
Max. Inlet Pressure of Compressed Air MPa – – – –
Max. Inlet Temperature of Compressed Air
Ambient Temperature –
Dew Point of Outlet Air
Cooling Method of Condenser -
Refrigerant Control Device -
Capacity Control Device -
Refrigerant Used -
Charged Quantity
Finish Color -
Cooling Water Quantity m3/h
Cooling Water Pipe Diameter -
Pipe Diameter -
Dimensions (W×D×H) mm
Weight kg
Accessories -
NOTE:
1. The capacity values above are measured at an ambient temperature of 32˚C, inlet temperature of 40˚C, inlet pressure of 0.69MPa.
2. Dew point gets worse if operated at pressure below the range of operation pressure.
3. Dimensions do not include the pipes and protruding parts. Refer to the drawing for more details.
4. In case of having solid objects such as rust in the inlet air flow, install a pre-filter on the inlet of dryer.
Air Filter 1
Micron Mist Filter 2
Activated Carbon Filter 3
Specifications
Item Model 7.5BX 11BX 15G1 22G1 37G1 55B 75B 100B 125C 160C 200C 240B
m /min
3
1.2 1.8 2.7 5.2 8.6 10.6 13.8 20 27.6 32 40 50
32
MPa 0.69 0.7 0.69
-
MPa 1.57 1.0 0.97
- Rc3/4 Rc1 Rc1-1/2 Rc2 2-1/2 in FF (Flange) 3 in FF (Flange) 4 in FF (Flange)
Item Model HAF-7.5BX HAF-11BX HAF-15G1 HAF-22G1 HAF-37G1 HAF-55B HAF-75B HAF-100B HAF-125C HAF-160C HAF-200C HAF-240B
5 – 60
2 – 60
μm 1
99.999
Pressure MPa 0.005
Drop (Loss) MPa 0.07
mm 92×237 130×290.5 170×588 170×673 170x718 173x811 173x968 590×1,511 590×1,511 590×1,511 640×1,735
- Rc1/4 Hose nipple for Φ5.7 6.0 inner diameter tube
kg 1 2 2.1 3.2 3.5 3.7 4.3 6 41 43 43 73
Item Model HMF-7.5BX HMF-11BX HMF-15G1 HMF-22G1 HMF-37G1 HMF-55B HMF-75B HMF-100B HMF-125C HMF-160C HMF-200C HMF-240B
Use 5 – 60
Condition 2 – 60
wtppm 0.01
Pressure MPa 0.01
Drop (Loss) MPa 0.07
mm 92×237 130×364 170x660 170x745 170x791 173x884 173x1,041 590×1,511 590×1,511 590×1,511 640×1,735
- Rc1/4 Hose nipple for Φ5.7 6.0 inner diameter tube
kg 1 2 2.1 3.2 3.5 3.7 4.3 6 41 43 43 73
Item Model HKF-7.5BX HKF-11BX HKF-15G1 HKF-22G1 HKF-37G1 HKF-55B HKF-75B HKF-100B HKF-125C HKF-160C HKF-200C HKF-240B
Use 5 – 60
Condition 2 – 60
wtppm 0.003
MPa 0.009
mm 92×232 130×281.5 160×362 170×447 170×498 173×591 173×748 590×1,511 590×1,511 590×1,511 640×1,735
kg 1 2 3.2 3.5 3.7 4.3 6 41 43 43 73
Make sure to install an air dryer before the filter.
1 The density of oil in the inlet air is 3wtppm.
2 According to "Test methods for oil aerosol content" of ISO8573-2, the density of oil in the inlet air is 3wtppm.
3 According to "Test methods for oil aerosol content" of ISO8573-2, the density of oil in the inlet air is 0.01wtppm.
4
HITACHI ROTARY COMPRESSOR OIL HITACHI FOOD GRADE ROTARY COMPRESSOR OIL
Specifications Specifications
Item Unit Content Item Unit Content
ISO Viscosity Grade - 32 ISO Viscosity Grade - 32
Density @15˚C kg/L 0.86 Color Phase - Colorless and Transparent
Viscosity @40˚C mm2/s 32.6 Density @15˚C kg/L 0.84
Viscosity Index - 102 Viscosity @40˚C mm2/s 32.8
Flash Point ˚C 200 Flash Point ˚C 200 or higher
Content L 20 Pour Point ˚C -50 or lower
Package - Plastic Container Tank Content L 20
Weight kg About 18 Exchange Cycle - 8,000 operating hours or 1 year which comes earlier
Exchange Cycle - Every half year Flushing running operation with the exclusive flushing use oil
Retrofit -
NOTE: Do NOT use this oil on the compressor which requires synthetic lubricating oil. (new oil 20L can) for 30 minutes × twice then refill with new oil
Package - Plastic Container Tank
Weight kg About 18
NOTE:
1. Compliance Standard / Law: NSF H1 registration No. 150658 and FDA21 CFR178.3570
2. For retrofitting from conventional mineral oil to HITACHI FOOD GRADE DSP OIL,
contact your nearest Hitachi sales representative.
12
Systems and Options
Energy-saving Combinations
3 ways to maximize energy-saving effect
Energy saving operation without Energy saving operation with Energy saving operation with multiple
external controller external controller Vtype model and external controller
Single-V / Multi-V
Example of Multi-Unit Control System
Fixed Speed
Model
Fixed Speed
DSP + type Model Full load lock
DSP Fixed Speed Models Fixed Speed
Model
type Start/Stop
400
Explanation
Power Consumption Ratio (%)
V
300
type
V F
200 Always running, follow the fluctuation of air consumption
V F F
100
F F F Fixed speed type or type
V
Full load or stop
0 100 200 300 400
Air Consumption Ratio (%) F indicates Fixed Speed Model.
13
Options
DSP
Single-Stage Two-Stage Two-Stage
Vtype Fixed Speed Model Vtype Fixed Speed Model Vtype Fixed Speed Model
Oil Mist Remover (OMR) Standard Standard Standard Standard Standard Standard
Instantaneous Power
Standard Standard Standard Standard Standard Standard
Interruption (IPI) Restart
Multi-unit Control
(with )
Alternate Operation
(with )
Alternate Operation
V-M Combination 2 2 2
Modbus®/TCP
Package Filter
Dust Filter
Specified Color of
Sound-Proof Cover
NOTE:
1 Alternate Operation is possible between same models or models of the same series.
In case of alternate operation between models of different series, connection and control by is necessary.
2 In case of V-M Combination, modification on the Fixed Speed Model is not necessary.
∙ For other options, contact your nearest dealer or Hitachi local representative office.
Installation location
- Install the compressors indoors. Do not use the compressors in a place where it is exposed to moisture such as rain or steam.
Doing so may cause fire, electric shock, rusting, or decrease in product life.
- Use the products in a location where there are no explosive or flammable gases (acetylene, propane gas, etc.), organic solvents,
explosive dust, or fire nearby. Failure to do so may result in fire or accident.
- Do not use the products in locations where corrosive gases such as ammonia, acid, iron, sulfurous acid gas, etc. are present.
It may cause rusting, decrease in product life, or damage.
Terms of use
- Please read the "Instruction Manual" carefully before use and use the products correctly.
- Never modify the products or its parts. Doing so may cause damage or malfunction.
14
India
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
Registered Office
B-62, 6th Floor, Corporate House,
Judges Bungalow Road, Bodakdev,
Room2201, Rui Jin Building, No.205
Ahmedabad, Gujarat, 380054, India
TEL : +91 (79) 66046200
FAX : +91 (79) 66046243
Sanand Works
Plot No. SM 3 & 4, Sanand - II GIDC, Thailand
Industrial Estate, Bol Village, Sanand, Hitachi Asia (Thailand) Co., Ltd.
Gujarat, 382110, India 12th Floor, Ramaland Bldg., No.952,
TEL : +91-2717-678777 Rama IV Road, Suriyawongse, Bangrak,
FAX : +91-2717-678700 Bangkok 10500, Thailand
ISO14001 ISO9001
EC97J1107 JQA-QM3443
Hitachi Screw Compressor is manufactured at a factory approved by Environmental Standard
(ISO 14001) and Quality Standard (ISO9001) of International Organization for Standardization.
E208 0224