L9 MiniCircuitBreakers

The Series L9 Miniature Circuit Breakers by Sprecher+Schuh are UL489 and CSA 22.2 No. 5.1 approved devices designed for branch circuit protection, offering current ranges from 0.5A to 63A and voltage options of 240V AC and 480Y/277V AC. These breakers feature a trip-free mechanism, color-coded indicators for device status, and are suitable for various applications including control circuits with additional options for auxiliary contacts and shunt trip modules. With a compact design and finger-safe protection, the L9 series is ideal for industrial equipment worldwide.

Uploaded by

sana555agha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views13 pages

L9 MiniCircuitBreakers

The Series L9 Miniature Circuit Breakers by Sprecher+Schuh are UL489 and CSA 22.2 No. 5.1 approved devices designed for branch circuit protection, offering current ranges from 0.5A to 63A and voltage options of 240V AC and 480Y/277V AC. These breakers feature a trip-free mechanism, color-coded indicators for device status, and are suitable for various applications including control circuits with additional options for auxiliary contacts and shunt trip modules. With a compact design and finger-safe protection, the L9 series is ideal for industrial equipment worldwide.

Uploaded by

sana555agha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Series L9 Sprecher+Schuh includes a line of

circuit breakers approved for branch


To aid troubleshooting, a color-coded
indicator provides positive visual
UL489 Miniature circuit applications in the United
States and Canada and certified as a
indication of the device status (green
for OFF, red for ON and isolation
Miniature Circuit Breaker for IEC function).
Circuit Breakers applications.
The Series L9 also incorporate a trip
Broad product range & free mechanism - ensuring that the
device operation cannot be defeated
flexibility by holding the operator in the ON
Industrial Circuit The Sprecher + Schuh L9 Miniature
position.
Breakers for Branch Circuit Breakers provide a variety of
product configurations by offering cur- Easy installation
Circuit Protection rent ranges of 0.5A to 63A with voltage
The Series L9 Miniature Circuit Break-
ranges of 240V AC and 480Y/277V
up to 63 Amps AC. The Series L9 DIN Rail-mounted ers mount on a standard 35mm DIN-
circuit breakers are similar in width rail. Wire terminals accept multiple
and current range to supplementary conductors. In addition, power to the
protectors with the added benefit of circuit breakers can be fed from the
providing listed branch circuit protec- line or load side.
tion for US/Canada applications.
Global approvals for
Also available for control circuit
applications are add-on auxiliary and worldwide acceptance
signal contacts plus shunt trip modules
® to provide modern control circuit The Sprecher + Schuh L9 Circuit
applications. A lock-off attachment is Breakers are UL489 listed, CSA 22.2
available for applications requiring that No. 5.1 approved and meets IEC
feature. 60 947-2. The Series L9 also have
an HACR rating (heating and air
conditioning) as well as a “Switching
Safety features provide Duty” (SWD) rating from 0.5 to 20A.
Switching Duty ratings are related to
enhanced protection fluorescent light applications only, not
High intensity discharge (HID) lights
The series L9 Miniature Circuit Break- or any other types of loads. Advanced
ers feature finger-safe IP20 from the features and global approvals make
front of the circuit breaker to guard the Series L9 an ideal product for
against accidental contact with live use in industrial equipment installed
parts. throughout the world.

M
L9 Circiut Breakers

See online white paper

Methods of Applying

Circuit
Protection
17.6mm 35mm 52.4mm
(≈11/16˝) (≈1-3/8˝) (≈2-1/8˝)

M20 One Pole Two Pole Three Pole


visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
Product Design & 489 and CSA 22.2 No. 5.1). For IEC
applications, the products are rated
Application 415V AC 0.5 to 40A.
The Series L9 products are thermal-
magnetic (inverse time) circuit break-
ers offering the benefits of a modern
Continuous Current Rating
circuit breaker design in a compact Standard current ratings are: 0.5A, 1A,
size. The L9 is used mainly in con- 1.6A, 2A, 3A, 4A, 5A, 6A, 7A, 8A,
trol circuit applications where branch 10A, 15A, 16A, 20A, 25A, 30A, 32A,
circuit approved circuit breakers are 35A, 40A, 50A, 60A and 63A.
required. by UL. For a specific current at 40°C
The L9 circuit breakers are rated (104°F), a circuit breaker will open
Because of its range of protection in RMS amperes at 40°C (104°F) (“clear the circuit”) automatically at
(from 0.5 to 63A) many customers may ambient temperature per the UL some total time that will be within the
use this product for protection of load 489 (CSA 22.2 No. 5.1) standard. “Minimum” and “Maximum” time
devices where fuses or other supple- This temperature is generally used as shown on the curves.
mentary protector devices previously the average temperature within an
were used in the U.S. and Canada. industrial enclosure. If a circuit breaker Example: The L9 time-current graph
is applied in a temperature that exceeds on page M28 shows that a one-pole,
Protection of PLC I/O, solenoids, 40°C (104°F) ambient, then the 15 A, L9 circuit breaker trips in not less
power supplies and control transform- circuit breaker should be derated. For than 10 sec, and not more than 120
ers along with providing the listed IEC 60 947-2 standard, the products sec. on a 30 A current. Because the UL
branch circuit protection is available in carry an ambient rating of 30° C. standard defines this time spread, users
one device. Follow standard IEC application should not specify exact tripping time.
considerations for temperature rating The lower current portion of the curves
in different ambient temperatures. (upper left) depict the time to trip due
Description to thermal action and reflect overload
Detailed characteristic trip curves protection of the wire and connect
L9 Circuit Breakers for Branch Circuit are shown in our online white load. The higher current portion of the
protection are available in one (1)-, two paper, Methods of Applying Circuit curves (lower right) depicts the trip due
(2-), and three (3-) pole construction Protection. The trip bands shown to the magnetic action of the circuit
and are rated 0.5 to 63A at 240VC for each breaker represent current breaker and reflects protection due to
AC and 0.5 to 40A at 480Y/277V AC tripping limits for a circuit breaker short circuit level currents.
for North American applications (UL and are within the limits established

Compare these advanced features


Line and load side terminals
designed with dual terminals which
allows the connection of two wires,
or both a wire and a bus bar.
Box lug terminals accept #18…#4
AWG wire as standard

M
Guarded No.2 pozidrive terminal
screws with finger-safe IP20
protection
Current limiting and interrupting

L9 Circiut Breakers
capacity of 10kA at 480Y/277V AC.
Accepts right-mounted shunt trips,
auxiliary and signal contacts.

Amp rating and trip curve


characteristic clearly marked on the Devices install on standard 35mm
device for easy identification. DIN-rail (EN 50022)

Trip-free mechanism; device Color coded indicator provides


operation cannot be defeated by visual indication of the device status
holding the operator in the ON and isolation function
position
Magnetic trip elements provide Type
Available in one, two and three pole C and D trip characteristics (IEC
and EN 60947-2), while bimetallic
elements protect against slight
overloads.

M21
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
L9 UL489 Miniature Circuit Breakers
Trip Characteristic C

Trip Characteristic C (5~10 x IN) – Inductive loads


1 Pole ➋ 2 Pole ➌ 3 Pole

➊ Interrupt Rated
UL/CSA Rating Current Std. Std. Std.
Max. Volt. (kA) (A) Catalog Number Pkg. Catalog Number Pkg. Catalog Number Pkg.
0.5 L9-0.5/1/C 2 L9-0.5/2/C 1 L9-0.5/3/C 1
1 L9-1/1/C 2 L9-1/2/C 1 L9-1/3/C 1
1.6 L9-1.6/1/C 2 L9-1.6/2/C 1 L9-1.6/3/C 1
2 L9-2/1/C 2 L9-2/2/C 1 L9-2/3/C 1
3 L9-3/1/C 2 L9-3/2/C 1 L9-3/3/C 1
4 L9-4/1/C 2 L9-4/2/C 1 L9-4/3/C 1
5 L9-5/1/C 2 L9-5/2/C 1 L9-5/3/C 1
6 L9-6/1/C 2 L9-6/2/C 1 L9-6/3/C 1
7 L9-7/1/C 2 L9-7/2/C 1 L9-7/3/C 1
8 L9-8/1/C 2 L9-8/2/C 1 L9-8/3/C 1
480Y/277 10
10 L9-10/1/C 2 L9-10/2/C 1 L9-10/3/C 1
13 L9-13/1/C 2 L9-13/2/C 1 L9-13/3/C 1
15 L9-15/1/C 2 L9-15/2/C 1 L9-15/3/C 1
16 L9-16/1/C 2 L9-16/2/C 1 L9-16/3/C 1
20 L9-20/1/C 2 L9-20/2/C 1 L9-20/3/C 1
25 L9-25/1/C 2 L9-25/2/C 1 L9-25/3/C 1
30 L9-30/1/C 2 L9-30/2/C 1 L9-30/3/C 1
32 L9-32/1/C 2 L9-32/2/C 1 L9-32/3/C 1
35 L9-35/1/C ➍ 2 L9-35/2/C ➍ 1 L9-35/3/C ➍ 1
40 L9-40/1/C ➍ 2 L9-40/2/C ➍ 1 L9-40/3/C ➍ 1

M 240 10
50
60
L9-50/1/C
L9-60/1/C
2
2
L9-50/2/C
L9-60/2/C
1
1
L9-50/3/C
L9-60/3/C
1
1
L9 Circiut Breakers

63 L9-63/1/C 2 L9-63/2/C 1 L9-63/3/C 1

L9 Miniature Circuit Breaker Features:


•UL-489 listed for Branch Circuit protection and CSA 22.2 No. 5.1 Approved
•Thermal magnetic protection
•Trip characteristic based on 40°C ambient for UL/CSA
•All ratings are HACR rated (SWD rated up to 20 A)
•Finger safe design (front)
•DIN rail mounting

➊ See page M26 for IEC 60947-2 miniature circuit breaker ratings.
➋ 1-Pole 277V AC 0.5…40A; 240V AC 50…63A, 48V DC 0.5…63A
➌ 2-Pole (series) 96V DC 0.5…63A
➍ Rated 480Y/277VAC.

M22
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
L9 UL489 Miniature Circuit Breakers
Trip Characteristic D

Trip Characteristic D (10~20 x IN) – Highly inductive loads


1 Pole ➋ 2 Pole ➌ 3 Pole

➊ Interrupt Rated
UL/CSA Rating Current Std. Std. Std.
Max. Volt. (kA) (A) Catalog Number Pkg. Catalog Number Pkg. Catalog Number Pkg.
0.5 L9-0.5/1/D 2 L9-0.5/2/D 1 L9-0.5/3/D 1
1 L9-1/1/D 2 L9-1/2/D 1 L9-1/3/D 1
1.6 L9-1.6/1/D 2 L9-1.6/2/D 1 L9-1.6/3/D 1
2 L9-2/1/D 2 L9-2/2/D 1 L9-2/3/D 1
3 L9-3/1/D 2 L9-3/2/D 1 L9-3/3/D 1
4 L9-4/1/D 2 L9-4/2/D 1 L9-4/3/D 1
5 L9-5/1/D 2 L9-5/2/D 1 L9-5/3/D 1
6 L9-6/1/D 2 L9-6/2/D 1 L9-6/3/D 1
7 L9-7/1/D 2 L9-7/2/D 1 L9-7/3/D 1
480Y/277 10 8 L9-8/1/D 2 L9-8/2/D 1 L9-8/3/D 1
10 L9-10/1/D 2 L9-10/2/D 1 L9-10/3/D 1
13 L9-13/1/D 2 L9-13/2/D 1 L9-13/3/D 1
15 L9-15/1/D 2 L9-15/2/D 1 L9-15/3/D 1
16 L9-16/1/D 2 L9-16/2/D 1 L9-16/3/D 1
20 L9-20/1/D 2 L9-20/2/D 1 L9-20/3/D 1
25 L9-25/1/D 2 L9-25/2/D 1 L9-25/3/D 1
30 L9-30/1/D 2 L9-30/2/D 1 L9-30/3/D 1
32 L9-32/1/D 2 L9-32/2/D 1 L9-32/3/D 1
35 L9-35/1/D ➍ 2 L9-35/2/D ➍ 1 L9-35/3/D ➍ 1
40 L9-40/1/D 2 L9-40/2/D 1 L9-40/3/D 1
50 L9-50/1/D 2 L9-50/2/D 1 L9-50/3/D 1
240 10

M
60 L9-60/1/D 2 L9-60/2/D 1 L9-60/3/D 1
63 L9-63/1/D 2 L9-63/2/D 1 L9-63/3/D 1

L9 Miniature Circuit Breaker Features:

L9 Circiut Breakers
•UL-489 listed for Branch Circuit protection and CSA 22.2 No. 5.1 Approved
•Thermal magnetic protection
•Trip characteristic based on 40°C ambient for UL/CSA
•All ratings are HACR rated (SWD rated up to 20 A)
•Finger safe design (front)
•DIN rail mounting

➊ See page M26 for IEC 60947-2 miniature circuit breaker ratings.
➋ 1-Pole 277V AC 0.5…35A; 240V AC 40…63A, 48V DC 0.5…63A
➌ 2-Pole (series) 96V DC 0.5…63A
➍ Rated 480Y/277VAC.

M23
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
Accessories
Series L9 UL489 Miniature Circuit Breakers

Accessories ➊➋
UL/CSA Max. IEC Ratings Connection Catalog
Module Description For use with… Current/Voltage Current/Voltage Diagrams Number

2A @ 230V (AC-14)
Signal Contact
1A @ 480V AC 1A @ 400V (AC-14) 98 96
• Mounts on right side of
2A @ 277V AC 1.5A @ 110V
L9 (series B only) All L9 Series B &
• Contacts change state Shunt Trips
1.5A @ 125V DC (DC-12) 95 L9-AMRS3
2A @ 60V DC 1A @ 220V (DC-12)
only during an electrical
4A @ 24V DC 4A @ 24V (DC-13)
1NO/NC
(or tripped) operation. (1CO)
2A @ 60V (DC-13)

Auxiliary Contact 2A @ 230V (AC-14)


• Mounts on right side of 1A @ 480V AC 1A @ 400V (AC-14) 14 12
L9 (series B only) 2A @ 277V AC 1.5A @ 110V
All L9 Series B & 11
• Contacts change state 1.5A @ 125V DC (DC-12) L9-AMRA3
Shunt Trips
when L9 breaker is 2A @ 60V DC 1A @ 220V (DC-12) 1NO/NC
operated either manually 4A @ 24V DC 4A @ 24V (DC-13) (1CO)
or electrically. 2A @ 60V (DC-13)

Shunt Trip –
110…415V AC
• Remotely trips the ~ C1 L9-AMST1
110...250V DC
device All L9 Series B
• Installs on right side of C2
L9 (Series B only)
12...60V AC/DC ~ L9-AMST2

Lock Out Toggle Mount –


• Fits securely over switch toggle. Prevents unauthorized activation of L8 or L9 (series B) L8 or L9 1-pole L8-ALOA1
during maintenance L8 or L9 Multi-pole L8-ALOA2
(Series B only)
1-pole multi-pole

M
L9 Circiut Breakers

➊ A maximum of one shunt trip, two signal contacts, or two auxiliary contacts may be installed per L9 Circuit Breaker.
➋ A maximum of three accessories may be installed per L9 Circuit Breaker. The shunt trip must be mounted closest to the L9, then the signal contact, then the auxiliary
contact(s). For allowed combinations, and installation instructions please contact your local Sprecher + Schuh representative.

M24
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
Accessories
Series L9 UL489 Miniature Circuit Breakers

L9 Bus Bars ➊➌➍➎


UL Max.
No. of Length Amps @ No. of Circuit
Description No. of Poles Phases ➋ 40°C Breakers Catalog Number Pkg Qty
Bus Bar 6 106 mm 6 L9-AMCL106
12 1 212 mm 12 L9-AMCL112
18 318 mm 18 L9-AMCL118
6 106 mm 3 L9-AMCL206
12 2 212 mm 80 6 L9-AMCL212 10
18 318 mm 9 L9-AMCL218
6 106 mm 2 L9-AMCL306
12 3 212 mm 4 L9-AMCL312
18 318 mm 6 L9-AMCL318

L9 Bus Bar Accessories ➊➎


Accessory Description Wire Range Catalog Number Pkg Qty
Terminal Lug

Terminal Lug #14 ... #2 AWG


• 1-pole for circuit breaker termina- L9-AMCLT35 10
tion 2.5 ... 35mm2

#14 ... #1 AWG


Dedicated Power Feed L9-AMCLT50D 10
2.5 ... 50mm2

Protective Cover
• For covering unused terminations ~ L9-AMCLPS 10
• 3 pole set (May be separated)

Other Accessories
Accessory Description Catalog Number M
DIN-rail - 2 meter lengths (6' 6")

L9 Circiut Breakers
Top Hat, low profile (price per rail) 3F
Top Hat, high profile (price per rail) 3AF
c

➊ cULus, UL508 E56639, EN60947-2, CE Marked.


➋ Total length from Circuit Breaker to Circuit Breaker when mounted on bus bars (not measurement of bus bar length).
➌ Bus bar can not be cut.
➍ Use of multiple bus bars permitted with overlap joint. Maximum of two joints permitted.
➎ Sold in complete package only. Order minimum quantity of 10 to receive one package of 10.

M25
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
Technical Information
Series L9 UL489 Miniature Circuit Breakers

Technical Information
Electrical Ratings Mechanical Data
Number of Poles 1, 2, or 3 Housing Insulation group II, RAL 7035
Tripping Characteristics C, D Indicator window red ON/green OFF
Rated Current In 0.5…63A Protection degree per EN 60529 IP20, IP40 in enclosure with
Rated Frequency f 50/60 Hz cover
Phase-to- Mechanical endurance 20,000 operations
Rated Insulation voltage 250V AC
ground Shock resistance per IEC/EN 60068-2-27 25 g - 2 shocks - 13 ms
Ui acc. to IEC/EN 60664-1
Phase-to-phase 440V AC Vibration resistance per IEC/EN 60068-2-6 5g - 20 cycles at 5…150…5
Overvoltage Category III Hz with load 0.8 In
Pollution Degree 3 Environmental conditions
28 cycles with 55°C/90-96%
(damp heat) per IEC/EN °C/RH
and 25°C/95-100%
60068-2-30
Data acc. to UL/CSA ➍ Ambient temperature ➌ -25…+55ºC
0.5...40 A 277V AC
C Curve Storage temperature -40…+70ºC
50...63 A 240V AC
1-pole
0.5...35 A 277V AC
D Curve
AC
40...63 A 240V AC Installation
Rated 0.5...40 A 480Y/277V AC Housing Terminal Dual terminal
C Curve
voltage 2-pole 50...63 A 240V AC Cross-section of wire solid, stranded 35/35 mm2
3-pole 0.5...35 A 480Y/277V AC
D Curve (front/back terminal slot) ➋ 18…4/18…10 AWG
40...63 A 240V AC
1-pole 48V DC Flexible (front/back terminal slot) 25/10 mm2
DC
2-pole 96V DC (2-pole in series) 1 wire; 18…4 AWG
Multi-wire rating per UL/CSA
Rated interrupting capacity per UL 489 10 kA 2-4 wires ➎; 18…10 AWG
Reference temperature for tripping Cross-section of bus bars (back terminal slot) 10 mm2
40 °C
characteristics
IEC 2.8 N•m
Electrical endurance 6,000 operations
(AC and DC) AWG 18...16: 13.3 in•lb
1 cycle (1s - ON, 9s -OFF) Tightening torque
UL/CSA AWG 14...10: 17.7 in•lb
AWG 8...4: 39.8 in•lb
Data acc. to IEC/EN 60947-2 Screwdriver No. 2 Pozidrive
1-pole 230V AC DIN Rail (EN 60715, 35 mm)
Rated operational voltage Ue Mounting
2-, 3-pole 400V AC with fast clip
1-pole 253/440V AC
AC Mounting position Any
Highest supply or 2-, 3-pole 440V AC
utilization voltage Umax 1-pole 48V DC Supply Optional
DC ➊
2-, 3-pole 96V DC
Min. operating voltage 12V AC, 12V DC Approximate Dimensions/Weight
Rated ultimate short-circuit breaking capacity Icu 15 kA 111 x 69 x 17.5 mm
≤40 A: 11.25 kA Pole dimensions HxDXW

M
Rated service short-circuit breaking capacity Ics (4.37" x 2.72" x 0.69")
>40 A: 7.5 kA
Pole weight 125 g (4.4 oz)
(1.2/50μs) 4 kV (test
Rated impulse withstand voltage Uimp. voltage 6.2kV at sea
Combination with Auxiliary Elements
L9 Circiut Breakers

level, 5kV at 2,000m)


Dielectric test voltage 2 kV (50/60Hz, 1 min.) Auxiliary contact Yes
Reference temperature for tripping characteristics 30 °C Signal contact Yes
Electrical endurance
Shunt trip Yes
1 cycle (2s - ON, 13s - OFF, In ≤
In < 30A: 20,000 operations (AC)
32A)
1 cycle (2s - ON, 28s - OFF, In > 10,000 ops. (AC);
In ≥30A:
32A) 1,000 ops. (DC)

➊ Self-declared IEC DC ratings.


➋ 35mm self-declared. Not included in IEC/EN approval.
➌ Refer to Ambient Temperature tables.
➍ UL file E197878.
➎ Wires must be of like size and stranding. Up to two wires
per terminal slot.

M26
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
Technical Information
Series L9 UL489 Miniature Circuit Breakers

Applying L9 UL489 Miniature Circuit Breakers in accordance with UL & NEC Guidelines
The L9 circuit breakers are rated in RMS amperes at a 40 °C (104 °F) ambient temperature per UL 489/CSA C22.2 No. 5. This temperature is used as the
ambient temperature external to an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the 40 °C (104 °F) ambient rating, then
the circuit breaker should be derated using the table below. For IEC 60947-2 standard, the products carry an ambient rating of 30 °C. Follow standard
IEC application considerations for temperature rating in different ambient temperatures.

Note: Application below 0º C is for non-condensing atmosphere. Care should be taken for applications below 0 °C. These devices are not certified to oper-
ate correctly in the presence of ice.

Temperature Derating, UL Temperature Derating, IEC


Reference temperature = 40 °C Reference temperature = 30 °C
Current Ambient temperature (°C) Current Ambient temperature (°C)
Rating Rating
[A] -25 -20 -10 0 10 20 30 40 50 55 [A] -25 -20 -10 0 10 20 30 40 50 55
0.5 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5
1 1.2 1.2 1.2 1.1 1.1 1.1 1.0 1 1.0 0.9 1 1.2 1.2 1.1 1.1 1.1 1.0 1 1.0 0.9 0.9
1.6 2.0 2.0 1.9 1.8 1.8 1.7 1.7 1.6 1.5 1.5 1.6 1.9 1.8 1.8 1.7 1.7 1.6 1.6 1.6 1.5 1.5
2 2.5 2.4 2.4 2.3 2.2 2.1 2.1 2 1.9 1.9 2 2.3 2.3 2.2 2.2 2.1 2.1 2 1.9 1.9 1.9
3 3.7 3.7 3.6 3.4 3.3 3.2 3.1 3 2.9 2.8 3 3.5 3.5 3.4 3.3 3.2 3.1 3 2.9 2.8 2.8
4 5.0 4.9 4.7 4.6 4.4 4.3 4.1 4 3.9 3.8 4 4.7 4.6 4.5 4.4 4.2 4.1 4 3.9 3.8 3.7
5 6.2 6.1 5.9 5.7 5.6 5.4 5.2 5 4.8 4.7 5 5.8 5.8 5.6 5.5 5.3 5.2 5 4.9 4.7 4.6
6 7.4 7.3 7.1 6.9 6.7 6.4 6.2 6 5.8 5.7 6 7.0 6.9 6.7 6.5 6.4 6.2 6 5.8 5.6 5.6
7 8.7 8.6 8.3 8.0 7.8 7.5 7.3 7 6.7 6.6 7 8.2 8.1 7.8 7.6 7.4 7.2 7 6.8 6.6 6.5
8 9.9 9.8 9.5 9.2 8.9 8.6 8.3 8 7.7 7.6 8 9.3 9.2 9.0 8.7 8.5 8.2 8 7.8 7.5 7.4
10 12.4 12.2 11.9 11.5 11.1 10.7 10.4 10 9.6 9.4 10 11.7 11.5 11.2 10.9 10.6 10.3 10 9.7 9.4 9.3
13 16.1 15.9 15.4 14.9 14.4 14.0 13.5 13 12.5 12.3 13 15.1 15.0 14.6 14.2 13.8 13.4 13 12.6 12.2 12.0
15 18.6 18.3 17.8 17.2 16.7 16.1 15.6 15 14.4 14.2 15 17.5 17.3 16.8 16.4 15.9 15.5 15 14.6 14.1 13.9
16 19.8 19.6 19.0 18.4 17.8 17.2 16.6 16 15.4 15.1 16 18.6 18.4 17.9 17.4 17.0 16.5 16 15.5 15.0 14.8
20 24.8 24.4 23.7 23.0 22.2 21.5 20.7 20 19.3 18.9 20 23.3 23.0 22.4 21.8 21.2 20.6 20 19.4 18.8 18.5
25 31.0 30.6 29.6 28.7 27.8 26.9 25.9 25 24.1 23.6 25 29.1 28.8 28.0 27.3 26.5 25.8 25 24.3 23.5 23.1
30 37.2 36.7 35.6 34.4 33.3 32.2 31.1 30 28.9 28.3 30 35.0 34.5 33.6 32.7 31.8 30.9 30 29.1 28.2 27.8
32 39.7 39.1 37.9 36.7 35.6 34.4 33.2 32 30.8 30.2 32 37.3 36.8 35.8 34.9 33.9 33.0 32 31.0 30.1 29.6
35 43.4 42.8 41.5 40.2 38.9 37.6 36.3 35 33.7 33.1 35 40.8 40.3 39.2 38.2 37.1 36.1 35 34.0 32.9 32.4
40 49.6 48.9 47.4 45.9 44.4 43.0 41.5 40 38.5 37.8 40 46.6 46.0 44.8 43.6 42.4 41.2 40 38.8 37.6 37.0
50 62.0 61.1 59.3 57.4 55.6 53.7 51.9 50 48.2 47.2 50 58.3 57.5 56.0 54.5 53.0 51.5 50 48.5 47.0 46.3
60 74.4 73.3 71.1 68.9 66.7 64.4 62.2 60 57.8 56.7 60 69.9 69.0 67.2 65.4 63.6 61.8 60 58.2 56.4 55.5
63 78.2 77.0 74.7 72.3 70.0 67.7 65.3 63 60.7 59.5 63 73.4 72.5 70.6 68.7 66.8 64.9 63 61.1 59.2 58.3

L9 Circiut Breakers

M27
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
Technical Information
Series L9 UL489 Miniature Circuit Breakers

Tripping Characteristics

C Curve D Curve

M
L9 Circiut Breakers

M28
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
Dimensions
Series L9 UL489 Miniature Circuit Breakers

L9 Miniature Circuit Breakers (Series B…Curve C & D)


Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

17.5 mm
(0.69”)

67 mm
(2.6”)
74 mm
(2.9”)

84.8 mm
(3.34”)
111 mm
1-Pole
(4.37”)

1-Pole

52.5 mm
35.0 mm (2.06”)
(1.38”)

69 mm
(2.7”)
75 mm
(3.0”)

84.8 mm
(3.34”)
111 mm 2-Pole 3-Pole
(4.37”)

2-, 3-Pole

Shunt Trip (L9-AMST1, -AMST2)


17.5 mm
M

L9 Circiut Breakers
99 mm (0.69”)
(3.90”)

74 mm
64.2 mm
(2.91”)
(2.53”)

M29
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
Dimensions
Series L9 UL489 Miniature Circuit Breakers

Signal Contact (L9-AMRS3) and Auxiliary Contact (L9-AMRA3)


Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

8.8 mm
(0.35”)
99 mm
(3.90”)

74 mm
(2.91”)

L9-AMCLT35 - Terminal Lug L9-AMCLT50D - Power Feed


6 3
14

31.2
28.8
72.1

17.6
4
6
17.75 51 12.6

16.2 31.1

L9-AMCLPS - Protective Cover

7 mm 3.6 mm

M
(0.28”) (0.14”)

24 mm
L9 Circiut Breakers

(0.94”)

13 mm 16 mm
(0.51”) 48.2 mm (0.63”)
(1.9”)

2 X 17.6 mm = 35.2 mm
(2 x 0.69” = 1.39”)
17.8 mm 17.6 mm
(0.70”) (0.69”)

M30
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018
Dimensions
Series L9 UL489 Miniature Circuit Breakers

L9 -AMCL_06 - 6 Pole Bus Bars


Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

99 15,5

32,5
46
5 1,5
17,6
5x17,6 = 88

L9-AMCL_12 - 12 Pole Bus Bars

204,6 15,5

32,5
46
5 1,5
17,6
11x17,6 = 193,6

L9-AMCL_18 - 18 Pole Bus Bars

310,2 15,5

M
32,5

L9 Circiut Breakers
46

5 1,5
17,6
17x17,6 = 299,2

M31
SSNA2018 visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information
Dimensions
Series L9 UL489 Miniature Circuit Breakers

Applying L9 Bus Bars & Accessories

M
L9 Circiut Breakers

NOTE: Do not cut bus bars. Maximum of 3 bus bars allowed in any combination
of the same phase configuration. Multiple bus bars must be installed back-
to-back.

M32
visit www.sprecherschuh.com/ecatalog for pricing and the most up to date information SSNA2018

You might also like