OssBuilder & Kit
3D Pre-Formed Titanium Membrane
• The 3D design eliminates the need for trimming or bending,
 enhancing surgical convenience
• It minimizes membrane exposure during the bone healing period
• It requires only a minimal gingiva incision for membrane removal,
 resulting in a shorter recovery period
| Anchor                                            ØD                     | Healing/Cover Cap                                       D
• Prevents the inflow of foreign                                           • Used for securing OB, Anchor, or                                   H
  materials into the implant and                                             Tenting screws, which are placed on
  secures space for bone grafting                                            top of the anchor or tenting screw                          Healing
• Available in Ø3.5 mini and Ø4.0 regular                                  • Healing cap is for a non-submerged                          Cap
  (H: 0, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0mm)                                  procedure for patients with
                                                                                                                                                0.3mm
※ Disposable, Sold separately                                                insufficient soft tissues
  (not included in the kit)                                                • Cover cap is for a submerged                                Cover
                                                                             procedure for patients with                                 Cap
| Tenting Screw Drill + Stopper/                                             sufficient soft tissue
                                                                           • Available in:
| Tenting Screw                                                              - Healing Cap: Ø4.0 and Ø5.0 (H: 3mm, 4mm)
• Serves as a support in situations where implant                            - Cover Cap: 1 type only - Ø4.0 (H: 1.5mm)
  placement is difficult
• For soft & normal bone, drill 3mm
• For hard bone, drill 5mm, then place the                                 | AutoBone Collector
  Tenting screw                                                            •   Used for autogenous bone collection
• Available in size:                                                       •   Capable of collecting up to 4mm in depth
  - Tenting Screw Drill: Ø1.0, Ø1.5                                        •   Ø4.0 is included in the kit
  - Stopper: 3mm, 5mm, 7mm                                                 •   Recommended speed: 500 rpm
  - Tenting Screw: L: 8.5, 10, 11.5, 13mm                                  ※ Ø3.0, Ø5.0 and Ø6.0 AutoBone Collectors
※ Tenting screws are sold separately, not included in the kit                are sold separately
                                                                                                                                    ØD
                                                                           | Bone Ejector/Defect Gauge
                                                                           • Tool to remove autogenous bone from the
   Soft/Normal bone Ø1.0                                                     bone collector
          Hard bone Ø1.5
| 0.9 Hex Hand Driver
• Enables connection to all                                                              • Tool to measure the length of bone
  components                                                                               defects
| OssBuilder Selections
                         OB2 Small horizontal or                                                 OB3 Large (>10 mm) horizontal or
                       vertical bone augmentation                                                  vertical bone augmentation
     Buccal damage       Buccal + Proximal damage    Buccal + Proximal +
                                                                                           For larger defects up to 20mm in horizontal length
                                                      Lingual damage
| 3D design eliminates the need for trimming or bending
• 3D Pre-formed design improves procedure convenience
• Available in a range of options to accommodate various clinical cases
     3D Titanium Membrance OB2                                                                                            3D Titanium Membrance OB3
| Minimal exposure of membrane during bone healing period
• Suturing with Cover Cap H: 0.3mm minimizes the possibility of exposure
• Healing Caps for non-submerged procedure for patients with insufficient soft tissues
Cover cap is used                                                                                                                      Healing cap is used
Thickness: 0.3mm                                       Cover Cap                Healing Cap                                            Thickness: 3.4 mm
                                                               OB2                OB3
                                                            3D Bending   3D Bending
                                                                         Anchor
                                                                         ET Implant
           Patients with sufficient soft tissue                                                                    Patients with insufficient soft tissue
| A minimal gingiva incision for membrane removal shortens the recovery period
                                                                            • The round design and strong rigidity maintain
                                                                              the shape securely without  fixation screws
                                                                            • Second surgery can be performed with
                                                                              minimal incision
Copyright © 2024 Hiossen Inc. All rights reserved.                       The President's
270 Sylvan Avenue. Suite 1130, Englewood Cliffs, NJ 07632                “E” Award
888.678.0001 | www.hiossen.com PB24OBKLTR1.0                                 Recognizing Excellence in Exporting             Smiles that last a lifetime