3369F091G PT

The document outlines the test plan for the Perkins Q20 T6.60 MTR pump, detailing specifications such as rotation, governor type, and various OEM codes. It includes ISO test conditions and procedures for evaluating pump performance under specified parameters. Pre-test notes and operational requirements for various test operations are also provided to ensure accurate testing and compliance.

Uploaded by

Alysson Campos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views2 pages

3369F091G PT

The document outlines the test plan for the Perkins Q20 T6.60 MTR pump, detailing specifications such as rotation, governor type, and various OEM codes. It includes ISO test conditions and procedures for evaluating pump performance under specified parameters. Pre-test notes and operational requirements for various test operations are also provided to ensure accurate testing and compliance.

Uploaded by

Alysson Campos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Test Plan: 3369090

Código: 3369090 Edição: 6


Aplicação: Perkins Q20 T6.60 MTR(DSA 9 Data de publicação:

PUMP SPECIFICATION.
Rotation: Clockwise.
Governor type: Mechanical all-speed.
Gov.Link Length: 52.5 ± 0.3 mm.
Governor spring
See nameplate code.
position:
Plunger diameter: 7.0 mm (4 off).
Drive type: Uprated with supported shaft.
Advance type: Automatic speed.
Solenoid shut-off device. 12 volts.
Transfer pressure adjuster in end plate.
2643D802 ISO
OEM Code: MK75L1100/6/2310
Code:
2643D822 ISO
OEM Code: MK75L1100/6/2310
Code:
MK56L800/2/2310
OEM Code: ISO Code: V3369F091G
Pump:

ISO TEST CONDITIONS.


This data is only valid for the test conditions specified and the
following test benches: HA3000/HA2500/HA1150/HA1100MkII/HA875
HA700/HA400/AVM/PGM
Test fluid: ISO 4113 at 40 ± 2 °C
Feed pressure: 0.1 bar
Nozzle opening pressure: 172 + 3 - 0 bar.
Nozzles: ISO 4010.
H.P. pipes: 6 x 2 x 845 mm (ISO 4093.2).

PRE-TEST NOTES.
Screw transfer pressure adjuster fully out then 3 turns in.
Minimum piston spring cap shim thickness 2.5 mm .
No additional shimming is required.

ISO TEST PROCEDURE.


Test Operation S/C RPM Requirement
1. Priming (C) 100 Obtain delivery from all injectors.
No air in pump back leak.
2. Transfer Press (C) 100 Minimum 0.69 bar ( 10 psi).
3. Transfer Press (S) 900 4.49 bar (65 psi)
4. Transfer Press (C) 1100 5.16 to 5.87 bar(75 to 85 psi)
5. Advance (C) 650 0° to 0.25°.
6. Advance (C) 1000 2.75° to 3.25°.
7. Backleakage 1100 10 to 100 cm3 per 100 strokes.
(Flow rate 110 to 1100cm3/min.)
8. Max. Delivery (S)* See Coded value ± 0.7 mm3/st.
(Coded Pumps) code Maximum spread 7.0 mm3/st.
9. Delivery (C) 1100 Record delivery cm3.
10. Governor (S) 1180 2.0 cm3. Maximum Line 3.0 cm3.
11. Delivery (C) 1100 Throttle as test(10),
Minimum as test(9 ) - 0.4 cm3.
12. Shut-off lever (C) 200 Max. 1.0cm3. Shut-off lever closed
13. Delivery - S/C 200 Maximum 1.5cm3.
Low load Throttle lever closed.
14. Stop solenoid (C) 325 Max. 0.5cm3. De-energise solenoid.
15. Governor (S) See 2.0cm3.
(Coded Pumps) code (Pump speed is half engine speed).
16. Delivery (C) 100 Minimum as test(8 ) - 3.6 cm3.
17. Timing S/C Outlet 'Y ', Pressure 55 bar
Indexing tool at 336°, Scribe line.
REFER TO STATEMENT AT END OF EXPLANATORY NOTES REGARDING
MAXIMUM
FUEL AND SPEED SETTING AND VARIATIONS IN ENGINE PERFORMANCE.
Todos os nomes de marcas comerciais aqui mencionados são exclusivamente
usados como referência. Todas as marcas comerciais são propriedade dos seus
respectivos donos.
© BorgWarner Inc.
Delphi Technologies is a brand of BorgWarner inc.
Privacy Policy
2.7.10