STORAGE TANK SPECIFICATION                                                                               Sheet   1 of 1
(English Units)
                                                                                                                                                                                           Rev. No.
                                                                                                                                    Project No.
 1 Service :                                                                                                                      Equipment No. :
 2 Location :                                                                       Unit :                                        Design Engineer :
 3 Manufacturer :                               Model :                                                    Mfr Ref. No. :                                   No. Req'd :
 4 P&ID No.                                                   Plot Plan No. :                                                Other Ref. Dwg No. :
 5
 6
 7
 8
 9                                                                            M
                                                 A             P                                           G
10
11
12
13                                                                                 50.00 Ft
                                                                          48" X 48"
                                                                                                                             H
14
                                                                           FLUSH
15               32.00 Ft          E                                      CLEANOU
                                                                                               K                             E
16                                                                            T
17                                 L                          F                                                              D
18
19                                                                   N       N
                                                                                           J           I
20                                                                   1        2
21
22
23
24 Shell Diameter :      50.00         Feet                        Shell Height :          32.00 Feet              Nominal Volume :             11,191               Barrels
25 Roof Type :          Cone                                                                   Bottom Floor Type:                Sloped
26                       OPERATING/DESIGN DATA                                                                                   NOZZLES/CONNECTIONS
27 Fluid Stored :              CRUDE OIL                       Sp. Gr. :          0.7900        Mark                    Service                Qty       Size         Rating       Face
28 This Tank Service is considered:                         Cyclic                                 A              Roof Manway                  2         24"          150#         F. F.
29 Vapor Pressure @ Max. Operating Temperature                             5.5       psia          E              Shell Manway                 2         24"          125#         R. F.
30 Flash Point (Closed Cup) :                          ºF     Operating           Design           F            Flush Cleanout MW              1       48"x48"        125#         R. F.
31 Negative Pressure                             oz/in.2          0.00             0.50            G               Stilling Vent               1          6"          125#         F. F.
32 Positive Pressure                                 psig         1.00             2.00            H           Temperature Indicator           1          1"          150#         L. J.
33 (Hydro)test Pressure expressed in Psig                          ----                            I               Outlet Nozzle               1          8"          150#          API
34 Minimum Fluid Temperature                           ºF                          -25             J                Fill Nozzle                1         10"          150#         L. J.
35 Maximum Fluid Temperature                           ºF                          200             K              Mixer Manway                 1         30"          150#         F. F.
36 Emergency Vacuum Design ?                  Yes            Set @        0.0.3    oz/in.2         L            Water Draw Nozzle              1          4"          150#         R. F.
37                                 METALLURGY                                                      M             Top Center Vent               1          8"          150#          API
38         Component               Material            CA, in.              Remarks              N1                Sample Tap                  1         3/4"         150#         R. F.
39 Shell & Bottom                   57370              0.1250              Normalized            N2                Sample Tap                  1         3/4"         150#         F. F.
40 Roof                       516 Grade 55             0.1250              Normalized              P               Roof Nozzle                 1          4"          150#         L. J.
41 Lining/Coating                                                                                  D                    Spare                  1          2"          150#          API
42                                                                                                                                                                    150#          API
43 Stress Relieve ?            Yes            for:                                                                                                                    150#          API
44                      CONSTRUCTION/FABRICATION
45 Code (as appl.):                    API 650 LATEST EDITION                                  Internals (attach separate sheet, as req'd):                            Others:
46 Design Specifications:                                                                                                                 Sump
47 Tank Insulation ?          No                Thickness :                          in.       Seismic Zone                  3        Design Wind Velocity                   100     mph
48 Insulation Type:                  Hot                                                       Radiograph               85        % Inspection Req'd ?                   Yes
49 Fireproofing ?       Yes                     Paint Spec.                                    EmptyTank Weight                           lb         Full of Water                     lb
50 Remarks
51        1. Items marked with an asterisk (*) to be completed by Vendor/Fabricator.
52        2. Fixed cone roof with internal floating roof.
                                                                                      Approvals
     Rev         Date              Description                 By          Chk.     Appr.       Rev              Date               Description                 By       Chk.      Appr.
      0                            For Inquiry
                                                                                                         March 12, 2002
Art Montemayor                                     API 650 Storage Tank
                                                                                                                 Rev: 0
                                             API 650 Design Calculations
                        D = Normal tank diameter , in feet             50.00
                                  H = depth of tank , in feet          32.00
   Shell Design :        FROM ( BOTTOM COURSE) PLATE TO (TOP COURSE) PLATE
                                   td = 2.6(D)(H -1)(G)/Sd=            0.174 in. Wall Thickness
Miniumum shell thickness, in inches, td = td / tt = 2.6(D)(H-1)/(St)
                                                          td =         0.224 in. (Includes Corrosion Allowance)
                     G = design Specific gravity of liquid              1
              Sd = allowable Stress for Design condition          23,200
                                     E = joint efficiency          0.85%
                St = allowable stress 516-60 Hydro Test            24,900
                              CA = Corrosion Allowance             0.0625
            For First Course (Bottom) 516-60 Plate                     0.236
                                   td = 2.6(D)(H -1)(G)/Sd =           0.189
                               td =td / tt = 2.6(D)(H-1)/(St) =
              td = Miniumum shell thickness, in inches =               0.230
                    D = Normal tank diameter , in feet =            50.00
                              H = depth of tank , in feet =         32.00
                   G = design Specific gravity of liquid =              1
            Sd = allowable Stress for Design condition            21,300
            E = joint efficiency                                   0.85%
            St = allowable stress516-60 Hydro Test                 24,000
            CA = Corrosion Allowance                               0.0625
            For Second Course 516-60 Plate                         0.5000
            td = 2.6(D)(H -1)(G)/Sd=                                   0.165
            td =td / tt = 2.6(D)(H-1)/(St)
            td = Miniumum shell thickness, in inches                   0.209
            D = Normal tank diameter , in feet                      50.00
            H = depth of tank , in feet                                28
            G = design Specific gravity of liquid                       1
            Sd = allowable Stress for Design condition            21,300
            E = joint efficiency                                   0.85%
            St = allowable stress 516-60 Hydro Test                24,000
            CA = Corrosion Allowance                               0.0625
            For Third Course 516-60 Plate                          0.3750
                                                                                               FileName: 863330215.xls
                                                         Page 2 of 8
                                                                                               WorkSheet: Steel Design
                                                                                                          March 12, 2002
Art Montemayor                                  API 650 Storage Tank
                                                                                                                  Rev: 0
                                           API 650 Design Calculations
Shell Design :
                                 td = 2.6(D)(H -1)(G)/Sd=            0.196
                             td =td / tt = 2.6(D)(H-1)/(St) =
                        td = Miniumum shell thickness =          0.2365 inches
          D = Normal tank diameter , in feet                       94.5
          H = depth of tank , in feet                                18
          G = design Specific gravity of liquid                       1
          Sd = allowable Stress for Design condition            21,300
          E = joint efficiency                                   0.85%
          St = allowable stress 516-60 Hydro Test                24,000
          CA = Corrosion Allowance                               0.0625
          For Fourth Course 516-60 Plate                         0.2500
          td = 2.6(D)(H -1)(G)/Sd=                                   0.081
          td =td / tt = 2.6(D)(H-1)/(St)
          td = Miniumum shell thickness, in inches               0.1342
          D = Normal tank diameter , in feet                       94.5
          H = depth of tank , in feet                                 8
          G = design Specific gravity of liquid                       1
          Sd = allowable Stress for Design condition            21,300
          E = joint efficiency                                   0.85%
          St = allowable stress 516-60 Hydro Test                24,000
          CA = Corrosion Allowance                               0.0625
          For Fifth Course 516-60 Plate                          0.2500
Annular Bottom Plate Thickness                                   0.3750
          D = Diameter in Feet                        50.00
          H = Height in Feet                          32.00
          V = Volume in Cubic Feet
                       Tank Shell surface =        p*D*H =           5,027 Ft2 of Shell surface area
                        Tank Roof surface =       p*D2/4 =           1,963 Ft2 of Roof Area (estimated)
                        Tank Floor surface =      p*D2/4 =           1,963 Ft2 of Bottom Floor area
                                                                                              FileName: 863330215.xls
                                                       Page 3 of 8
                                                                                              WorkSheet: Steel Design
                                                                                                    March 12, 2002
Art Montemayor                               API 650 Storage Tank
                                                                                                            Rev: 0
FOUNDATION DESIGN:
      Per API 650 (Appendix E)
      Tank is unanchored, use equations pertaining to unanchored tanks,
      for seismic loading.
      DATA GIVEN:
      Seismic Zone;                                                                          3
      Zone Coefficient                                                   Z=                0.3
      Importance Factor                                                  I =               1.0
      Diameter of Tank                                                   D=               94.5
      Height of Liquid Content (Design)                                  H=               44.5
      Shell Height                                                      Hs =                48
      Design Specific Gravity                                            G=               0.79
      Thickness of Bottom PL Under Shell                                 tb =           0.3750
      Yeild Strength of Bottom PL                                       Fby =           36,000   PSI
      Weight of Shell                                                  Ws =                221   Kips
      Weight of Roof + Live Load = 107.4 + 210.4                       Wy =              317.8   Kips
      Weight of Product      PI()/4(94.5)2 (44.5)(.79)(62.4)            Wt =            15,386   Kips
      CALCULATIONS:
      Seismic Coefficients:
                                                                       Xs =             19.685 Ft
                                                                        C1 =              0.60
                                                                       D/H =              2.12
      Per Fig. E-2
      W1 / Wt =         0.535                                          W1 =              8,231
      W2 / Wt =          0.45                                          W2 =              6,924
      Per Fig. E-3
      X1 /H =           0.375                                           X1 =              16.7
      X2 /H =            0.59                                           X2 =              26.3
      Per Fig. E-4
      K = 0.6
      Lateral Force Coefficients:           E-3.3
      T =K (D 0.5 ) =.6 *(94.5 0.5) =                                                     5.83 Seconds
      If Greater Than 4.5 seconds           3.375 (s/T2) = 3.375*1.5/5.832 =             0.149 Seconds
                                                                                       FileName: 863330215.xls
                                                    Page 4 of 8
                                                                                WorkSheet: Foundation Design - 1
                                                                                                  March 12, 2002
  Art Montemayor                                  API 650 Storage Tank
                                                                                                          Rev: 0
FOUNDATION DESIGN:
        Seismic Loads:
        M = (Z)(I) { (C1)(Ws)(Xs)+(C1)(Wr)(Ht)+(C1)(W)(X)+(C2)(W2)(X2)}
        (0.3)*(1.0)[ 0.6(221)(19.685)+ 0.6(317.8)(48.0)+ 0.6(8232)(16.7)+ 0.149(6924)(26.3)]
                0.3       2610          9155            82485           27133           36415 Ft-Kips
        V = (Z)(I) {(C1)(Ws)+(C1)(Wr)(Ht)+(C1)(W)(X)+(C2)(W2)(X2)}
        (0.3)*(1.0)[ 0.6(221)+ 0.6(317.8)+ 0.6(8232)+ 0.149(6924)]
                0.3       132.6       190.68           4939.2      1031.676                1888 kips
        Reistance to Overturning:( E.4.1) API 650
        WL = 7.9tb Ö Fby G H      (G18)*(G16)*(G14)/(G13)2 )                              3,333    # / ft
                                                         1265580          1125
                     Constant =                               7.9
             3,333      # / ft    Not to exceed 1.25*GHD                                   4153    # / ft
                                                                          USE              4153    # / ft
        Shell Compression: Per E-5
        M=               36415 ft-kips
        Wt + WL = 583.8 / (PI()*94.5) + 4.153                                                 6 Kips
        M / D2 (Wt + WL)          (G76)/(G13)2(6.12)
                                         36415                 54653                      0.666 > 0.785
                     b = 1.815+1.273*36415/94.5^2                         b =               7.0
        Max. Longitudinal Compressive Force                                                 7.0
        UnAnchored Longitudinal Compressive Stress
                           7000 / 6                                                        1167
        Allowable Longitudinal Compressive Stress
                  GHD2/t2  1.255 * 106 = Fa=106 (t) / D =                                  5.29 Kips
                                           Anchorage Not Required
                                                                                        FileName: 863330215.xls
                                                        Page 5 of 8
                                                                                 WorkSheet: Foundation Design - 1
                                                                                                       March 12, 2002
Art Montemayor                              API 650 Storage Tank
                                                                                                               Rev: 0
     FOUNDATION DESIGN:
                 Max. Overturning Moment Due To Seismic Loads.                    36,415 Kips
                 Compression or Tension Due To Moment:                              5.19 kpf
                 Seismic Base Shear:                                                0.27 kips
                 RINGWALL DESIGN:
                 Use Following Weight Values for Materials
                 Wt. of Steel                                   490lb/ft3
                 Wt. Of Compacted Soil                          110 lb/ft3
                 Wt. Of Concrete Wall                           150 lb/ft3
                 Wt. Of Product in Tank                         50 lb/ft3
                 Horizontal Pressure on Ring Wall:
                           F=Kah(g*p*H+1/2 soh)+270
                           0.3*6.0[(50*44.5+0.5*110*6.0)]+270                      4,869 kips
                 Hoop Tension:
                           1/2FD= 1/2(4869)(94.5)                                    230 kips
                           As= 231/24.0                                               10 in.
                           USE - 6 # 9 Bars Ea. Face
                           USE - # 4 Bars at 12" on Center
                 Minimum RingWall Thickness:
                           T = 2W / g *p*h - 2h ( gc - gso)     W = 1100
                           (2)(1100)/50(44.5)-2(6.0)(150-110)                   1.26
                                                                       Use 16" Thick Concrete Wall
                                                          12"
                                                                             Top of Ground Elevation
                               16"
                                                          48"
                                                          12"
                                                                                          FileName: 863330215.xls
                                                  Page 6 of 8
                                                                                   WorkSheet: Foundation Design - 2
                                                                                             March 12, 2002
Art Montemayor                              API 650 Storage Tank
                                                                                                     Rev: 0
                 Concrete Tensile Stress:
                           fct = c(Es)(As)+T / Ac + n (As)
                 .0003(29*106)(10)+231000/(16*72)+(9*10)
                               318000                    1242                 256 psi
                           .15(3000)                                          450 psi
                                                                              OK
                 Soil Bearing:
                            Try 3'- 6" Footing
                            Weight. of Wall = 1.33*5.0*.150                    1.0   kips
                            Weight of Footing = 3.5*1.0*.150                0.525    kips
                            Weight of Fill = 2.17*4.0*.110                   0.95    kips
                                                                             2.48    kips
                            Case 1
                            Load from Shell + Roof + Live Load =              1.1 kips
                            Weight of Wall +Footing + Fill =                 2.48 kips
                                       Bearing Pressure =       3.58/3.50     1.0 kips
                            Case 2
                            Dead + Live Load + Earthquake Load =
                            P = 3.58 + 5.19 =                                8.77 kips
                            H=                                              0.270 kips
                            Moment at Base of Footing =         .270(6.0)    1.62 kips
                            Bearing Pressure Under Footing =
                            8.77/3.5*1                                       2.51 kips
                                                          2.51+.79           3.30 kips
                            Allowable Pressure = 3.0*1.33                    3.99
                                                                              OK
                            USE -4 # 9 Bars in Footing
                            USE - # 4 Bars at 12" Horizontal
                                                                                   FileName: 863330215.xls
                                                  Page 7 of 8
                                                                            WorkSheet: Foundation Design - 2
                                                                                                                           March 12, 2002
Art Montemayor                                                       API 650 Storage Tank
                                                                                                                                   Rev: 0
  DETAILED FOUNDATION DESIGN:
                                                                                       47" - 3"
                                                                                                                      Center Line of Tank
                                                                                                   Slope 1" per ft.
     12"
                         6 # 9 Bars Each Face Eq. Spaced
                                                                                    10" Pad of Sand                       10"
                                                                                   Well-Compacted Gravel
                                                                                   95% Compacted
                                                                                   50 / 100 % Passing # 4 Sieve
                                                                      # 4 Bars 12" O/C Each Face
     4'-0"
                                                                       95 % Compacted Subgrade or fill Material
                                                                      1'-4" Wall
    12"
                       (4) # 9 Bars Eq. Spaced
                                                           3' - 6"
  NOTES:
  1. Oiled sand to be mixture of sand and liquid asphalt (mc70):
  2. Use 10 gallons of asphalt per cubic yard of sand:
  3. Top of concrete to be smooth and level with 1/8" +/- in any 30 feet of circumferential length:
  4. Maximum Deiation to be less than 1/4" overall:
                                                                                                             FileName: 863330215.xls
                                                                         Page 8 of 8
                                                                                                      WorkSheet: Foundation Design - 3