0% found this document useful (0 votes)
126 views24 pages

Simple

The document provides an overview of Leading Solution's SimpleView cable management system. It describes the system's hardware components including masters, scanners, patch panels, and accessories. It also outlines the SimpleView management software for monitoring and configuring the system. Key features of the software like site mapping and remote access are highlighted. Minimum and recommended server requirements to run the management software are listed.

Uploaded by

Wonbae Choi
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views24 pages

Simple

The document provides an overview of Leading Solution's SimpleView cable management system. It describes the system's hardware components including masters, scanners, patch panels, and accessories. It also outlines the SimpleView management software for monitoring and configuring the system. Key features of the software like site mapping and remote access are highlighted. Minimum and recommended server requirements to run the management software are listed.

Uploaded by

Wonbae Choi
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Leading Solution

Leading Solution

Electric Power Business Human communication connecting minds

Main energy artery lighting the world

Telecommunication Business

Awakening and changing prime power

Research & Development

Simple View

TM

From the beginning to the end. We leave nothing out when it comes to your satisfaction. We are currently developing eco-friendly and high-quality products to meet the respective needs of our various markets and to grow our capacity as a global player. We will try to increase the number of contracts for domestic and overseas cable management system projects with the objective of diversifying our products.

CONTENTS
Cable Management System Hardware Copper Patch Panel Fiber Optic Patch Panel Fiber MPO Patch Panel Patch Cord (Copper & Fiber) Accessories Management Software SitePro Global Network
07 08 11 14 15 18 19 20 21 22

Simple View
Providing high-speed, highly functional, and highly reliable products through leading technology.

TM

SimpleView

TM

Cable Management System

Description

Features

Benefits

Structure
SimpleView Management Software

LAN

Client Sever

Master

Scanner

Panel -Switch

Panel -Outlet

IP Phone

LS SimpleViewTM

- Cable Management System

SimpleView

TM

Hardware

Description

Products

Master

Expander

Master Expander

Scanner

Mini Scanner

Indicator Controller

LS SimpleViewTM

- Hardware

Products
Security Controller

Local Master

Local Scanner

Inter-Connection

Part Numbers & Physical Chracteristic


Description
SimpleViewTM Master (4 port) SimpleViewTM Expander SimpleViewTM Master Expander SimpleViewTM Scanner SimpleViewTM Mini Scanner SimpleViewTM Indicator Controller SimpleViewTM Security Controller SimpleViewTM Local Master SimpleViewTM Local Scanner SimpleViewTM Inter-Connection Solution

Dimensions (mm)
44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 191.7(D) 44.4(H) x 482.6(W) x 191.7(D) 44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 159.3(D) 44.4(H) x 482.6(W) x 191.7(D) 88.0(H) x 482.6(W) x 159.3(D)

Part Number
LS-Master-4Port LS-Expander LS-Master Expander LS-Scanner LS-Mini Scanner LS-Indicator Controller LS-Security Controller LS-Local Master LS-Local Scanner LS-Inter-Connection

LS SimpleViewTM

- Hardware

Specifications(Excludes 6527 1736-00)


Panel rack mounting
Product weight

1U 19 (IEC 60297)
2.0 Kg / 4.4 lb

Interfaces
Up/down links Serial Standard RS-485, Full-duplex connector shielded RJ-45 socket Data rate up to 115.2 Kbps RS-232 Connector 9-pin D-type male Data rate up to 115.2 Kbps Protocol UART, start bit 1, Stop bit 1, non-parity 100BASE-Tx RJ-45 socket, Ethernet IEEE 802.3, 100BASE-Tx / 10BASE-T, 100/10 Mbps industry standard for connection to local area network Control pad Connector RJ-45 socket, 8 pins

LED Indicators (Where used)


Patch panel connections PWR CPU DOWN LINKYELLOW DOWN LINKGREEN 100BASE-Tx - Rx 100BASE-Tx - Tx Connectors 6 or 12 headers, 26-pin On when scanner is powered Blinking to indicate master heartbeat On during transmission of each of the DOWN LINK ports On during reception of each of the DOWN LINK ports On during reception from local area network On during transmission to local area network

Environmental and Safety


100BASE-Tx LINK Operating temperature range Operating humidity range Safety EMC Power On when link is active 0 - +50 90% relative humidity non-condensing UL 60950, EN 60950 EN 55022, FCC part 15 Class A, EN 55024 100 ~ 240 VAC, 47 ~ 63 Hz, 30W maximum

10

LS SimpleViewTM

- Hardware

SimpleView

TM

Copper Patch Panel

Description

Products
Category 6A Patch Panel

Category 6 Patch Panel with Switch Port

Category 6(High-Density)

LS SimpleViewTM

- Copper Patch Panel

11

Products

Category 6 Patch Panel

Category 6 Modular Jack Panel

UTP & STP RJ to RJ Patch Panel

12

LS SimpleViewTM

- Copper Patch Panel

Part Numbers & Physical Chracteristic


Description
SimpleViewTM 10G Category 6A Unshielded Patch Panel SimpleViewTM 10G Category 6A Shielded Patch Panel SimpleViewTM Category 6 Unshielded Patch Panel(With Switch Ports) SimpleViewTM Category 6 Unshielded Patch Panel SimpleViewTM Category 6 Shielded Patch Panel SimpleViewTM UTP & STP RJ to RJ Patch Panel
XX Denotes Ports : 24=24Ports, 48=48Ports

Dimensions (mm)
44.0(H) x 482.6(W) x 35.0(D) 44.0(H) x 482.6(W) x 35.0(D) 88.0(H) x 482.6(W) x 35.0(D) 44.0(H) x 482.6(W) x 35.0(D) 44.0(H) x 482.6(W) x 35.0(D) 44.0(H) x 482.6(W) x 35.0(D)

Part Number
LS-IPP-UC6A-XX LS-IPP-SC6A-XX LS-IPP-UC6-48P-W/S LS-IPP-UC6-XX LS-IPP-SC6-XX LS-IPP-RJ-XX

Specifications
Panel rack mounting
Plug / jack mating cycles Plug / jack insertion / withdrawal force Product weight

1U 19 (IEC 60297)
750 (IEC / EN 60603-7 Series) 20N(UTP), 30N(STP) (IEC / EN 60603-7 Series) 0.9 Kg / 1.9 lb including jacks (UTP), 2.2 Kg / 4.8 lb (S/FTP)

Electrical
Insulation resistance Dielectric strength Current carrying capacity Typical plug / jack resistance Conductor terminations of LSA-PLUS contacts Conductor diameter 500M Contact / contact 1.0 kV 1A / contact 20m 30 0.5 - 0.65 mm (AWG 22-24)

Panel
Signal voltage Signal current Testing requirements of connection technology according to ISO / IEC 11801 2nd edition 5V dc 2 mA max (EN60950:2000) ANSI/TIA-568-B.2.1 and EN50173-1:2002

Environmental and Safety


Operating temperature range Operating humidity range -10 - +60
95% relative humidity non-condensing

LS SimpleViewTM

- Copper Patch Panel

13

SimpleView

TM

Fiber Optic Patch Panel

Description

Products
Fiber Patch Panel(LC)

Fiber Patch Panel(SC)

Fiber Patch Panel-LC 8 x 8

14

LS SimpleViewTM

- Fiber Optic Patch Panel

SimpleView

TM

Fiber MPO Patch Panel

Description

Products
Fiber Patch Panel - LC MPO 96(High Density)

Fiber Patch Panel - LC MPO 48

LS SimpleViewTM

- Fiber MPO Patch Panel

15

Part Numbers & Physical Chracteristic


Description
SimpleViewTM LC Fiber Patch Panel SimpleViewTM SC Fiber Patch Panel SimpleViewTM LC 8 x 8 Fiber Patch Panel SimpleViewTM LC MPO Fiber Patch Panel

Dimensions (mm)
44.0(H) x 482.6(W) x 240.0(D) 88.0(H) x 482.6(W) x 320.0(D) 44.0(H) x 482.6(W) x 240.0(D) 44.0(H) x 482.6(W) x 240.0(D)

Part Number
LS-IFPP-LC-XXX-YY LS-IFPP-SC-XXX-YY LS-IFPP-LC 8 x 8-XXX LS-IFPP-LC-MPO-XXX-YY

XXX Denotes SM(Single Mode), MM1(Multi Mode OM1), MM3(Multi Mode OM3) YY Denotes Cores : 24=24cores, 48=48cores, 96=96cores

Specifications
Panel rack mounting
Product weight Materials Number of trays Capacity Connector system Cable management Signal voltage Signal current 3.7 Kg / 8.1 lb Zintec - powder coated black RAL 9011 2 discrete (1U total height) 48 fibers max (LC) LC, MT-RJ, SC Internal 5V dc 2 mA max (EN60950:2000)

1U 19 (IEC 60297)

Connector Specification
Sleeve material Typical insertion loss, dB Singlemode - ceramic / Multimode-phosphor bronze Singlemode-0.2 / Multimode-0.3

Environmental
Operating temperature range Operating humidity range Standards -10 - +60 95% relative humidity non-condensing EN 6008-2-2, IEC 68-2-27, IEC 68-2-6, IEC 68-2-14, IEC 68-2-3, ISO/ IEC11801:2002

16

LS SimpleViewTM

- Fiber MPO Patch Panel

Simple View

TM

Making the huge world through the smaller, lighter and more convenient one

SimpleView

TM

Patch Cord (Copper & Fiber)

Products
Fiber MPO Patch Panel

Fiber Patch Cord(LC) / Fiber Patch Cord(SC)

Part Numbers
Description
SimpleViewTM Unshielded Patch Code SimpleViewTM Shielded Patch Code SimpleViewTM LC Fiber Patch Code SimpleViewTM SC Fiber Patch Code SimpleViewTM MT-RJ Fiber Patch Code

Part Numbers
LS-IPC-UCXX-ZZZ LS-IPC-SCXX-ZZZ LS-IFPC-LC-YYY-ZZZ LS-IFPC-SC-YYY-ZZZ LS-IFPC-MTRJ-YYY-ZZZ

XX Denotes 5e(Cat.5e), 6(Cat.6), 6A(Cat.6A) / YYY Donotes SM(Single Mode), MM1(Multi Mode OM1), MM3(Multi Mode OM3) / ZZZ Denotes 005(0.5m), 030(3m), 050(5m), 100(10m) etc

Technical Details-Copper

Environmental-Fiber
Cable Dimensions Cable Weight Min Bending Radius - Short Team Maximum Tensile Strength Maximum Compressive Load Flexing Operating Temperature Storage Temperature 2.6 3.7 mm ( +0/0.1) mm 14.8 kg/km Loaded : 45mm Installed : 35mm 300 N 100 N/cm 1,000 cycles -25 -25 to +75 to +75

18

LS SimpleViewTM

- Patch Cord(Copper & Fiber)

SimpleView

TM

Accessories

Products
Scanner Attachment Cords

Control Pad

Part Numbers
Description
Scanner Attachment Cords - Round Type Scanner Attachment Cords - Flat Type SimpleViewTM Control Pad
XXX Denotes 010(1m), 025(2.5m), 050(5m) etc

Part Numbers
LS-AC-Round-XXX LS-AC-Flat-XXX LS-Control Pad

Technical Details
Standards compliance Safety EMC Scanner Interface UL 60950, EN 60950 EN-55022, FCC Part 15 Class A, EN-55024 Connector RJ-45 socket Cable with two RJ-45 connectors on either side. One connects to the Control Pad and one to the CONTROL PAD PORT on the Front Panel of the Scanner LEDs LED SCAN RECONFIG ON / PENDING MANUAL SCAN Stays lit while Automatic Scan is in process Blinks when Reconfig. Is pending. Stays lit while work is in progress Stays lit while Manual Scan is in process

LS SimpleViewTM

- Accessories

19

SimpleView

TM

Management Software

Description

Structure

Technical Details

Technical Details

Part Numbers
Description
SimpleViewTM Software SimpleViewTM Software + SQL SimpleViewTM Software Additional SimpleViewTM Software CAD Module (Without MapGuide)*
XXXXX Denotes 01000 (1,000Port), 05000(5,000port), 10000(10,000Port) etc * CAD Module requires Autodesk MapGuide

Part Number
LS-CMS-XXXXX LS-CMS-SQL-XXXXX LS-CMS-ADD-XXXXX LS-CMS-CAD-MapGuide

20

LS SimpleViewTM

- Management Software

SimpleView

TM

Site Pro

Description

Application

Features

Server Requirements
Minimum Hardware Pentium processor running at least 800 MHz 1000 MB + RAM 20 GB hard disk space Recommended Hardware Dual Pentium 4 processor running at 2600 MHz 1024 MB RAM(or more) 40 GB+ hared disk space Software Windows 2000 family(Windows 2003 server family recommended) (Microsoft Internet Explorer 6 recommended) Microsoft SQL 2000(standard/Enterprise edition recommended) IIS 5(or higher) MSMQ - Microsoft message queing system Client Minimum Requirements - Software Any Microsoft based system(Win 95, 98, ME, NT, 2000, XP etc.) Microsoft Internet Explorer 5.5 with service pack1 (with signed ActiveX and cookie support)