0% found this document useful (0 votes)
52 views1 page

BV Sports Club Data Center: Hardware Set 1

The document is a detailed door schedule for a construction project, listing various doors along with their specifications such as dimensions, materials, and hardware requirements. It includes information on door types, access control systems, and fire ratings, as well as notes on the architectural design and construction guidelines. Additionally, it emphasizes the importance of coordinating with structural and mechanical drawings and ensuring compliance with safety standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views1 page

BV Sports Club Data Center: Hardware Set 1

The document is a detailed door schedule for a construction project, listing various doors along with their specifications such as dimensions, materials, and hardware requirements. It includes information on door types, access control systems, and fire ratings, as well as notes on the architectural design and construction guidelines. Additionally, it emphasizes the importance of coordinating with structural and mechanical drawings and ensuring compliance with safety standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Client

QTY UNIT PRODUCT DESCRIPTIONS FIN


Door Schedule
No.Of From Room: From Room: Rough Rough Door Profil Saddle HARDWARE-SE FIRE-R HARDWARE SET #1
Level Mark Leaves Number Name Width Height Type Mark Material Type Frame Material e Type T-TYPE ATING Remark
EACH TO HAVE
01_GROUND 01 ENTRANCE 1750 2400 REFER TO CURTAIN WALL SYSTEM PODWER COATED ALUMINIUM - S02 HS1 -
FLOOR ARCH. FRAME 3 each Hinges 3 Knuckle Concealed Bearing Heavy Weight (.180) 4 1/2" x 4" (NRP on Outswinging Doors with Locks) (A156.1) 630
FACADE
each Lockset Storeroom (F07) Interchangeable Core x Keyed Construction Core x ANSI Grade 1 UL Listed x Free Wheeling x 2 Piece Anti Friction Stainless Steel Latch x 3/4"
PACKAGE - 1 630
Throw (Solid ADA Lever to Meet ID Design x Through Bolt) (A156.13)
01_GROUND 01 1 12 GENERATOR 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS1 90 MIN Consultant
FLOOR ROOM HOLLOW METAL DOOR COATED STEEL FRAME
DOOR OPERATED WITH ACCESS CONTROL SYSTEM
A
1 each Interchangeable Permanent Core x Keying to Suit Requirements x 6/7 Pin as Required x 3 Change Keys x Concealed Stamping x Restricted Keyway (A156.5) 619
01_GROUND 02 2 11 ELECTRICAL 1400 2200 D02 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS2 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM
FLOOR ROOM HOLLOW METAL DOOR A COATED STEEL FRAME
Door Closer Heavy Duty Cast Alum Body x ADA x ANSI A117.1 Grade 1 UL Listed x Reg/PA x Adjustable Spring Size 1-6 x 3 Valves x UL 10C Approved Cover x Double Heat 689
01_GROUND 03 1 02 SECURITY 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS1 45 MIN 1 each
FLOOR STORAGE HOLLOW METAL DOOR A COATED STEEL FRAME
DOOR OPERATED WITH ACCESS CONTROL SYSTEM Treated Steel Pinion/Forged Steel Piston (Adjust Spring After Install/Max Opening Degree) (A156.4)
01_GROUND 04 2 10 UPS ROOM 1400 2200 D02 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS2 90 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM 1 each Wall Stop Concave or Floor Stop High/Low to be Coordinated with Door Undercut/Overhead Stop Where Wall or Floor Stop is Not Useable (As Per Floor Plan Req't) (A156.16/A156.8) 630
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME
01_GROUND 05 1 03 LOST & 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS1 45 MIN 1 each Seal Self Adhesive Silicone UL Listed/Smoke/Sound Certified (Perimeter Size As Per Door Schedule) (A156.22) CH
FLOOR FOUND HOLLOW METAL DOOR A COATED STEEL FRAME
DOOR OPERATED WITH ACCESS CONTROL SYSTEM
01_GROUND 06 1 04 STORAGE 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS1 45 MIN 628
1 each Door Sweep x Brush UL Listed/Smoke Certified (Length As Per Door Schedule) (Coordinate With Sill Details) (A156.22)
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME Key Plan
01_GROUND 07 1 06 STAIR 1100 2200 D09 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 45 MIN
FLOOR HOLLOW METAL DOOR B COATED STEEL FRAME
DOOR OPERATED WITH PANIC DEVICE
HARDWARE SET 1
01_GROUND 08 1 08 CORRIDOR 1100 2200 D09 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 45 MIN 1
DOOR OPERATED WITH PANIC DEVICE 1 : 20
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME
01_GROUND 09 1 09 STORAGE 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS1 45 MIN
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME QTY UNIT PRODUCT DESCRIPTIONS
FIN
01_GROUND 10 1 08 CORRIDOR 1100 2200 D09 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 45 MIN DOOR OPERATED WITH PANIC DEVICE
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME HARDWARE SET #2
01_GROUND 11 1 07 INFRA ENTRY 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS1 45 MIN
FLOOR ROOM HOLLOW METAL DOOR COATED STEEL FRAME
DOOR OPERATED WITH ACCESS CONTROL SYSTEM
A EACH TO HAVE
01_GROUND 12 1 05 IT ROOM 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS1 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME 8 each Hinges 5 Knuckle Ball Bearing STD/HW (Qty/Weight/NRP/Confirm Size: All As Per Spec/Door Schedule) (A156.1) 630
01_GROUND 13 2 06 TRIPLE - 1600 2200 D02A ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS2 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM
FLOOR PLAY & HOLLOW METAL DOOR COATED STEEL FRAME
SMART / 1 set AUTOMATIC UL Listed Top Flush Bolt x Auxiliary Fire Bolt (To Suit Metal Door/Wood Door) (A156.3) 630
SCADA
SERVER Lockset Classroom (F05) Interchangeable Core x Keyed Construction Core x ANSI Grade 1 UL Listed x Free Wheeling x 2 Piece Anti Friction Stainless Steel Latch x 3/4" Throw 630 Notes:
ROOM A
1 each (Solid ADA Lever to Meet ID Design x Through Bolt) (A156.13) 1-THE DRAWINGS ARE A DEVELOPMENT OF DESIGN AND TECHNICAL INTENT.
2- THE DRAWINGS INDICATE THE SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL DESIGN CONCEPT,
THE GEOMETRY AND DIMENSIONS OF THE BUILDING AND SYSTEMS, THE MAJOR ARCHITECTURAL AND INTERIOR
01_GROUND 14 2 19 NOVEC 1500 2200 D05 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S02 HS4 45 MIN ELEMENTS AND THE CONCEPTS OF THE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS. THE

FLOOR CLOSET HOLLOW METAL DOOR A COATED STEEL FRAME 1 each Cores under GMK, Small format 7 pins 626 DRAWINGS DO NOT
NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE FINAL CONTRACT DOCUMENTS.
01_GROUND 15 1 20 NOVEC 555 2200 D06 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S02 HS4 45 MIN 3-ALL DRAWINGS IN THIS SCOPE ARE TO BE READ IN CONJUNCTION WITH EACH OTHER I.E. ARCHITECTURAL,

FLOOR CLOSET HOLLOW METAL DOOR A COATED STEEL FRAME 1 each Bar Coordinator (Mtg Brackets if Required) x UL Listed (Width As Per Door Schedule) (A156.3) pt. STRUCTURAL,ELECTRICAL, MECHANICAL DRAWINGS .
4--THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF BUILDINGS ON THE SITE.
5- ALL DIMENSIONS ARE IN MILLIMETERS, ALL LEVELS ARE IN METERS UNLESS OTHERWISE NOTED.
01_GROUND 16 2 21 NOVEC 1500 2200 D05A ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S02 HS4 90 MIN 6- DOOR OPENING SHALL BE LOCATED EITHER MIDWAY IN WALL OR 100 mm OF WALLEND AS SHOWN ON DWGS. UNO.

FLOOR CLOSET HOLLOW METAL DOOR A COATED STEEL FRAME 2 each Door Closer Cast Alum Body x ADA x ANSI A117.1 Grade 1 UL Listed x Heavy Duty x Adjustable Spring Size 1-6 x 3 Valves x UL 10C Approved Cover x Double Heat Treated Steel 689 7- CONCRETE PAD LOCATIONS AND DIMENSIONS ARE TO BE COORDINATED WITH MECHANICAL EQUIPMENT
DIMENSIONS AND REQUIREMENTS AND TO BE READ IN CONJUNCTION WITH STRUCTURAL DRAWINGS.
8- FOR STRUCTURAL ELEMENTS SETTING OUT REFER TO STRUC. DRAWINGS.
01_GROUND 17 2 22 NOVEC 1500 2200 D05 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S02 HS4 45 MIN Pinion/Forged Steel Piston (Adjust Spring After Install/Max Opening Degree) (A156.4) 9- ALL SLAB AND WALL OPENINGS TO BE CHECKED AGAINST ELECTRO-MECH. AND STRUCTURE DRAWINGS.
10- ANY DISCREPANCIES (IF ANY) ARE TO BE BROUGHT TO THE ENGINEER'S ATTENTION FOR CLARIFICATION BEFORE
FLOOR CLOSET HOLLOW METAL DOOR A COATED STEEL FRAME WORK IS CONTINUED.

02_FIRST 01 2 01 COC ROOM 1600 2200 D02A ELECTROSTATIC POWDER COATED HS2 2 each Wall Stop Concave or Floor Stop High/Low to be Coordinated with Door Undercut (As Per Floor Plan Req't) (A156.16) 630 11- ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE RELEVANT STRUCTURAL,
MECHANICAL,ELECTRICAL AND OTHER DISCIPLINES DRAWINGS.
DOOR OPERATED WITH ACCESS CONTROL SYSTEM 12- ALL SLAB OPENINGS TO BE SURROUNDED BY 150 mm HEIGHT UPSTAND FROM FINISH FLOOR LEVEL UNO
FLOOR HOLLOW METAL DOOR ENSURING WATER TIGHTNESS, FIRE AND ACOUSTICAL ISOLATION AS PER ARCH DETAILS.

02_FIRST 02 1 02 ELEC ROOM 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS1 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM
1 each Dust Proof Strike x Adjustable Face Plate (A156.16) 626 13- ALL STRUCTURAL OPENINGS IN SLABS FOR DUCT WORKS,PIPES, CABLE TRAYS ETC., TO BE COMPLETELY FIRE
SEALED WITH 2HRS FIRE PROOFING MATERIAL AFTER INSTALLATION OF SERVICES.
14- THE CONTRACTOR IS TO ENSURE THE STABILITY OF ALL BLOCK WALLS. ESPECIALLY THOSE SPANNING LARGE
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME DISTANCES OR HEIGHTS. REINFORCED MASONARY MAY BE USED, TOGETHER WITH THE APPROPRIATE DETAILING AT
2 each Door Sweep x Brush UL Listed/Smoke Certified (Length As Per Door Schedule) (Confirm Finish with ID Design) (A156.22),on pull side 628 CONNECTION WITH FLOOR, WALLS AND CEILING. DETAILED CALCULATION OF BLOCKWALL SYSTEM AND LOADS ON
02_FIRST 03 1 13 OPERATOR 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S03 HS1 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM STRUCTURAL SLAB SHALL BE SUBMITTED BY THE CONTRACTOR FOR APPROVAL. DESIGN SHALL BE IN ACCORDANCE

HARDWARE SET 2
TO THE I.B.C
FLOOR ROOM HOLLOW METAL DOOR A COATED STEEL FRAME 15-CONCRETE LEVELS ON ARCHITECTURAL DRAWINGS ARE FOR INFORMATION ONLY. FOR CONCRETE LEVELS,
REFER TO STRUCTURAL DRAWINGS. THE FINISH FLOOR LEVEL (F.F.L.) IN THE ARCHITECTURAL DRAWINGS IS THE
02_FIRST
FLOOR
04 1 12 NOC ROOM 1100 2200 D01 ELECTROSTATIC POWDER COATED
HOLLOW METAL DOOR A
ELECTROSTATIC POWDER
COATED STEEL FRAME
P1 S03 HS1 45 MIN DOOR OPERATED WITH ACCESS CONTROL SYSTEM 2 1 : 20
BASIS OF ALL LEVELS IN ALL OTHER TRADES (STRUCTURAL, ELECTRICAL, MECHANICAL) IF ANY DISCREPANCIES ARE
FOUND, THE CONTRACTOR SHALL INFORM THE ENGINEER AND PROPOSE SOLUTIONS.
16-DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR
DESIGN INTENTION CANNOT BE DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
02_FIRST 05 1 03 MALE 900 2200 D03A MDF WOOD DOOR WITH ROUTER BEECH PINE WOOD - DARK P3 S01 HS3 - 17-GENERAL CONTRACTOR TO COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR, ROOF AND WALL SLEEVES
AND ALL MECHANICAL SHAFTS WITH MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, STRUCTURAL AND
FLOOR TOILETS ENGRAVING - NATURAL OAK WOOD STAIN FINISH QTY UNIT PRODUCT DESCRIPTIONS FIN
ARCHITECTURAL DRAWINGS
18-ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE PROCEEDING WITH THE WORK. THE
VENEER C ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ANY CORRECTION.
19-ALLDIMENSIONS SHALL BE VERIFIED AND COORDINATED WITH ALL OF THE WORK OF ALL TRADES.
02_FIRST 06 1 03 MALE 700 2185 D04 CUBICAL HPL DOORS FOR DETAILS & - - - REFER TO BE - 20-CONTRACTOR SHALL COORDINATE ALL FLOOR / ROOF HATCH OPENINGS IN CONCRETE STRUCTURE ALONG WITH

FLOOR TOILETS HARDWARE TO BE PROVIDED BY PROVIDED BY


HARDWARE SET #3 THEIR RELATED DIMENSIONS AND DETAILS WITH THE SELECTED FLOOR / ROOF HATCH SUPPLIER.
21-ALL WALLS BETWEEN MECHANICAL OR ELECTRICAL SPACES AND ANY SPACE SHALL BE ACOUSTICALLY ISOLATED
FROM THE
MANUFACTURE - MANUFACTURE EACH TO HAVE TENANT SPACES AND SHALL MAINTAIN MINIMUM SPECIFIED STC RATING.
22-ALL ELEVATOR OPENINGS SHALL BE CERTIFIED BY THE ELEVATOR SUB-CONTRACTOR PRIOR TO FORMING.
02_FIRST 07 1 03 MALE 700 2185 D04 CUBICAL HPL DOORS FOR DETAILS & - - - REFER TO BE - REQUIRED MODIFICATIONS SHALL BE BROUGHT TO THE ATTENTIONOF THE ENGINEER AND GENERAL CONTRACTOR

FLOOR TOILETS HARDWARE TO BE PROVIDED BY PROVIDED BY 3 each Hinges 3 Knuckle Concealed Bearing Standard Weight (.134) 4 1/2" x 4" (NRP on Outswinging Doors with Locks) (A156.1) 630
FOR APPROVAL PRIOR TO FORMING.
23-COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL & ELECTRICAL TRADES AND INSTALLER.
WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND INSTALLATION, REVIEW WITH ARCHITECT/ENGINEER PRIOR
MANUFACTURE - MANUFACTURE TO PROCEEDING.

each Lockset Privacy x O/S Emergency Coin Release/Indicator x I/S ADA T.T. x ANSI Grade 1 UL Listed x Free Wheeling x 2 Piece Anti Friction Stainless Steel Latch x 3/4" Throw
24-ALL RECESSED CABINETS,PANELS, BOXES LOCATED IN FIRE- RATED WALLS SHALL BE INSTALLED AND TOMAINTAIN
02_FIRST 08 1 04 GUEST 1100 2200 D03 MDF WOOD DOOR WITH ROUTER BEECH PINE WOOD - DARK P3 S01 HS3 - 1 630 THE FIRE- RATED CONSTRUCTION.

FLOOR TOILET ENGRAVIN - NATURAL OAK WOOD STAIN FINISH (Solid ADA Lever to Meet ID Design x Through Bolt) (A156.13) 25- FOR WALL TYPES REFER TO WALL TYPES SCHEDULE .
26- FOR FLOOR, WALL, CEILING FINISHES, DETAILS IN B.O.H AREAS, REFER TO ARCHITECTURAL FINISH SCHEDULE .
VENEER C 1 each Wall Stop Concave or Floor Stop High/Low to be Coordinated with Door Undercut/Overhead Stop Where Wall or Floor Stop is Not Useable (As Per Floor Plan Req't) (A156.16/A156.8) 630
27-FIRE RATINGS: DESIGN AND DETAILING OF THE EXTERIOR ENCLOSURE TO MAINTAIN FIRE RATINGS REQUIRED BY
PROJECT BUILDING CODES, REGULATIONS AND RELEVANT
28-THE INDICATED INSULATION THICKNESS PRESENTS THE MINIMUM REQUIRED THICKNESS,THE CONTRACTOR IS TO
02_FIRST 09 1 05 PANTRY 900 2200 D03A MDF WOOD DOOR WITH ROUTER BEECH PINE WOOD - DARK P3 S01 HS3 - ENSURE THAT THE ENVELOPE OVER ALL COMPOSITIONS ARE MEETING THE INTENDED DESIGN THERMAL AND
FLOOR ENGRAVING AND - NATURAL OAK WOOD STAIN FINISH 1 each Seal Self Adhesive Silicone UL Listed/Smoke/Sound Certified (Perimeter Size As Per Door Schedule) (A156.22) CH ACOUSTICAL PERFORMANCE INDICATED IN THE SPECIFICATIONS AND REPORTS.

VENEER C
1 each Coat Hook (To Meet ID Design) 619
02_FIRST 10 1 17 STAIR 1100 2200 D09 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 45 MIN
DOOR OPERATED WITH PANIC DEVICE
FLOOR HOLLOW METAL DOOR B COATED STEEL FRAME
HARDWARE SET 3
02_FIRST 11 2 16 CORRIDIR 1600 2200 D08 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 -
DOOR OPERATED WITH PANIC DEVICE 3
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME 1 : 20
02_FIRST 12 2 16 CORRIDIR 1600 2200 D08 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 -
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME DOOR OPERATED WITH PANIC DEVICE
QTY UNIT PRODUCT DESCRIPTIONS FIN ARCHITECTURAL DRAWINGS
02_FIRST 13 2 08 SECURITY 1600 2200 D08 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS2 45 MIN
FLOOR CONTROL HOLLOW METAL DOOR COATED STEEL FRAME DOOR OPERATED WITH ACCESS CONTROL SYSTEM
ROOM A HARDWARE SET #4
02_FIRST 14 1 10 SECURITY 1100 2200 D01 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS2 - Project Info
FLOOR MANAGER HOLLOW METAL DOOR A COATED STEEL FRAME DOOR OPERATED WITH ACCESS CONTROL SYSTEM EACH TO HAVE
02_FIRST 15 2 23 NOVEC 1000 2200 D07 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S03 HS4 45 MIN
FLOOR CLOSET HOLLOW METAL DOOR A COATED STEEL FRAME 8 each Hinges 5 Knuckle Ball Bearing STD/HW (Qty/Weight/NRP/Confirm Size: All As Per Spec/Door Schedule) (A156.1) 630
02_FIRST 16 1 14 CORRIDOR 1100 2200 D09 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P1 S02 HS5 -
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME DOOR OPERATED WITH PANIC DEVICE
02_FIRST 17 2 01 COC ROOM 1000 2200 D07 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S03 HS4 45 MIN 1 set AUTOMATIC UL Listed Top Flush Bolt x Auxiliary Fire Bolt (To Suit Metal Door/Wood Door) (A156.3) 630
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME DOOR OPERATED WITH ACCESS CONTROL SYSTEM
02_FIRST 18 1 14 CORRIDOR 555 2200 D06 ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER P2 S02 HS4 45 MIN Lockset Mortise Classroom (F05) Interchangeable Core x Keyed Construction Core x ANSI Grade 1 UL Listed x Free Wheeling x 2 Piece Anti Friction
FLOOR HOLLOW METAL DOOR A COATED STEEL FRAME 1 each 630
Stainless Steel Latch x 3/4" Throw (Solid ADA Lever to Meet ID Design x Through Bolt) (A156.13)
1 each Cores under GMK, Small format 7 pins 626

1 each Bar Coordinator (Mtg Brackets if Required) x UL Listed (Width As Per Door Schedule) (A156.3) pt.

2 each Door Closer Cast Alum Body x ADA x ANSI A117.1 Grade 1 UL Listed x Heavy Duty x Adjustable Spring Size 1-6 x 3 689 3 27-01-2025 I.F.C
2 22-05-2024 I.F.C
Valves x UL 10C Approved Cover x Double Heat Treated Steel Pinion/Forged Steel Piston (Adjust Spring After Install/Max Opening Degree) (A156.4)

01
1 16-05-2024 I.F.C

03 630
2 each Wall Stop Concave or Floor Stop High/Low to be Coordinated with Door Undercut (As Per Floor Plan Req't) (A156.16) 0 14-03-2024 I.F.C
Rev Date Description

Revision Schedule
1 each Dust Proof Strike x Adjustable Face Plate (A156.16) 626
Issue:

2 each Door Sweep x Brush UL Listed/Smoke Certified (Length As Per Door Schedule) (Confirm Finish with ID Design) (A156.22),on pull side 628
Project Name

HARDWARE SET 4
4 1 : 20
BV Sports Club
PRODUCT DESCRIPTIONS
Data Center
QTY UNIT FIN
Designed By: Designer
HARDWARE SET #5
Drawn By: Author

EACH TO HAVE Checked By: Checker

8 each Hinges 5 Knuckle Ball Bearing STD/HW (Qty/Weight/NRP/Confirm Size: All As Per Spec/Door Schedule) (A156.1) 630 Approved By: Approver

1 set AUTOMATIC UL Listed Top Flush Bolt x Auxiliary Fire Bolt (To Suit Metal Door/Wood Door) (A156.3) 630 SHEET SCALE: 1 : 20

Lockset Classroom (F05) Interchangeable Core x Keyed Construction Core x ANSI Grade 1 UL Listed x Free Wheeling x 2 Piece Anti Friction Stainless Steel Latch x 3/4" Throw 630
1 each (Solid ADA Lever to Meet ID Design x Through Bolt) (A156.13)
Drawing Title
1 each Cores under GMK, Small format 7 pins 626

1 each Bar Coordinator (Mtg Brackets if Required) x UL Listed (Width As Per Door Schedule) (A156.3) pt. DOORS SCHEDULES
2 Door Closer Cast Alum Body x ADA x ANSI A117.1 Grade 1 UL Listed x Heavy Duty x Adjustable Spring Size 1-6 x 3 Valves x UL 10C Approved Cover x Double Heat Treated Steel 689
each
Pinion/Forged Steel Piston (Adjust Spring After Install/Max Opening Degree) (A156.4)
2 each Wall Stop Concave or Floor Stop High/Low to be Coordinated with Door Undercut (As Per Floor Plan Req't) (A156.16) 630

1 each Dust Proof Strike x Adjustable Face Plate (A156.16) 626

2 each Door Sweep x Brush UL Listed/Smoke Certified (Length As Per Door Schedule) (Confirm Finish with ID Design) (A156.22),on pull side 628
Exit Device CVR X ANSI grade 1 UL listed x RX x LM x CON \ wire harness x flush end cap x No exposed screws \ rivets ( WDC as required ) ( width & height as per Door schedule)
2 each 630
(fire E\D on fire doors ) (A156.3)
PROJECT ORG. BUILD. DOC. SHEET REV.
HARDWARE SET 5 NUMBER NAME TYPE NUMBER
5 1 : 20 EG2114 EMD S.C AR 602 3