0% found this document useful (0 votes)
66 views9 pages

D1VW Ipc Uk

The document details the characteristics and technical specifications of the D1VW series directional control valves with inductive position control, designed for safety-relevant applications. It includes information on ordering codes, electrical characteristics, and performance curves, as well as guidelines for installation and maintenance. The valves are available in single and double solenoid configurations with various spool types and positions, ensuring versatility in hydraulic systems.

Uploaded by

miguel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views9 pages

D1VW Ipc Uk

The document details the characteristics and technical specifications of the D1VW series directional control valves with inductive position control, designed for safety-relevant applications. It includes information on ordering codes, electrical characteristics, and performance curves, as well as guidelines for installation and maintenance. The valves are available in single and double solenoid configurations with various spool types and positions, ensuring versatility in hydraulic systems.

Uploaded by

miguel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Catalogue MSG11-3500/UK Directional Control Valve

Characteristics Series D1VW Inductive Position Control

The direct operated directional valves series D1VW with


inductive position control are typically used in safety
relevant applications. The start or end position can be
monitored. The position control is available for single and
double solenoid valves.
The fail-safe position of the directional valve during power
failure is the spring offset or center position. 2
Please find detailed information on the machine directive
in the position paper in chapter 1.
D1VW*B D1VW*C

Attention:
The adjustment of the position control is factory set
and sealed. Replacement and repairs can only be
G G G
undertaken by the manufacturer. A B A B

P T P T

D1VW*B D1VW*C

D1VW*B

A B

D1VW*C

A B

D1VW-IPC UK.indd 23.06.2023

2-19 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Ordering Code Single Solenoid Valve Series D1VW Inductive Position Control

D 1 V W
Directional Size 3-chamber Wet pin Spool Spool
control DIN NG06 valve solenoid type position
valve CETOP 03

2 NFPA D03

3 position spools
Code Spool type
a 0 b
001

002

0031) 3 position spools


Code Spool position
004
G
0152)
A B
2 positions.
E a 0
Spring offset in position “0“.
076 P T

Operated in position “a“.


078
G
A B
2 positions.
2 position spools F 0 b
Operated in position “0“.
Code Spool type
P T

a b Spring offset in position “b“.


020 G
A B

2 positions.
0263) K 0 b
P T Spring offset in position “0“.
0303) Operated in position “b“.
A B
G

2 positions.
M a 0
P T Operated in position “0“.
Spring offset in position “a“.

2 position spools
Code Spool position

A B
G 2 positions.
B a b Spring offset in position “b“.
P T Operated in position “a“.

G
A B
2 positions.
H Spring offset in position “a“.
P T Operated in position “b“.

1)
Only available for spool position “E“ and “F“.
2)
Only available for spool position “K“ and “M“.
3)
Only available for spool position “B“ and “H“.
4)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
5)
Please order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).
6)
For hydraulic presses according to the safety regulations DIN EN ISO 16092-3, solenoid option “T” (without manual override) and accessory “I4N” or “I5N” (start
position monitored) are required.

D1VW-IPC UK.indd 23.06.2023

2-20 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Ordering Code Single Solenoid Valve Series D1VW Inductive Position Control

W
Seals Solenoid Connector Manual Position Design
voltage as per EN override control 5) series
175301-803, option (not required

2
without plug for ordering)
(please order
plug separately)

Code Position control Spool position


End position
I2N
monitored side B E, F, B
Start position (Solenoid on a-side)
I5N6)
monitored side B
End position
I1N
monitored side A K, M, H
Start position (Solenoid on b-side)
I4N6)
monitored side A

Code Manual override


manual override
omit
(Standard)
without manual
T6)
override

Code Voltage
K 12 V=
J 24 V=
U4) 98 V=
G4) 205 V=

Code Seals
N NBR
V FPM

Further spool types and voltages on request.


D1VW-IPC UK.indd 23.06.2023

2-21 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Ordering Code Double Solenoid Valve Series D1VW Inductive Position Control

D 1 V W W
Directional Size 3-chamber Wet pin Spool Spool Seals Solenoid Connector Manual Position Design
control DIN NG06 valve solenoid type position voltage as per EN override control 5) series
valve CETOP 03 175301-803, option (not required

2
NFPA D03 without plug for ordering)
(please order
plug separately)

3 position spools Code Position control Spool position


Code Spool type
I3N End positions C, D
a 0 b
I6N 4) Start positions C
001

002

003 1)
Code Manual override
004 manual override
omit
(Standard)
015 1)
without manual
T4)
override
2 position spools
Code Spool type
a b
020

Code Voltage
K 12 V=
J 24 V=
3 position spools
U3) 98 V=
Code Spool position
G3) 205 V=
G
A B
G 3 positions.
C a 0 b Spring offset in position “0“.
P T Operated in position “a“ or “b“.

Code Seals
2 position spools
N NBR
Code Spool position
V FPM
G
G
2 positions.
D 2) A B
Operated in position “a“ or “b“.
a b
P T
No center or offset position.

Further spool types and voltages on request.

1)
Only for position control code “I6N“.
2)
Only for position control code “I3N“.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4)
For hydraulic presses according to the safety regulations DIN EN ISO 16092-3, solenoid option “T” (without manual override) and accessory “I6N” (start positions)
is required.
5)
Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.

D1VW-IPC UK.indd 23.06.2023

2-22 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Technical Data Series D1VW Inductive Position Control

General
Design Directional spool valve
Actuation Solenoid
Size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03

2
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -20...+60
MTTFD value [years] 150
Weight [kg] 1.8 (1 solenoid) / 3.8 (2 solenoids)
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13
Flow max. [l/min] 80 (see shift limits)
Leakage at 50 bar [ml/min] Up to 10 per flow path, depending on spool
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Tolerance supply voltage [%] ±10 ±10 ±10 ±10
Current consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461.
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended

With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.

D1VW-IPC UK.indd 23.06.2023

2-23 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Position Control Series D1VW Inductive Position Control

Single solenoid valves


Electrical characteristics of position control as per IEC 61076-2-101 (M12x1)
Supply voltage [VDC] 24
Tolernace supply voltage [%]±20
Ripple supply voltage [%]≤10

2 Polarity protection
Current consumption without load
[V]
[mA]
300
≤20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C]-20 … +60
Protection IP65 acc. EN 60529 (with correctly mounted plug-in connector)
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
CE conform EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6 1) / ENV 50140 / ENV 50204

M12 pin assignment

1
US
DC st
2
1 + US 19.2...28.8 V
DC AC
2 1
Osz.
DC
Out
2 Out B: normally open 4
3 0V Out neg.
3 4 3
4 Out A: normally closed
GND

Outputs: Open collector

Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the spring is reached (above 85 % spool stroke).
offset position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.

The switch can only be located on the opposite side of the solenoid for direct operated valves.
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).

1)
Only guaranted with screened cable and female connector

D1VW-IPC UK.indd 23.06.2023

2-24 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Position Control Series D1VW Inductive Position Control

Double solenoid valves


Electrical characteristics of position control as per IEC 61076-2-101 (M12x1)
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C]-20...+60
Supply voltage Us / ripple [V]10...30 / ±10 %
Current consumption without load
Max. output current per channel, ohmic
[mA]
[mA]
≤ 10
200
2
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V]≤2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1 acc. to IEC 61076-2-101
Wiring min. [mm²] 3 x 0.14 brad shield recommended
Wiring length max. [m] 50 recommended

M12 pin assignment

(1)
4 +US

1 Us 10...30 V Last
1 3 2 not connected (4) Charge
Load
3 0V A
4 Out A: normally open RL
(3)
2 0V

Definitions
Start position monitored: End position monitored:
The valve is de-energized. The inductive switch gives a The inductive switch gives a signal before the end position
signal at the moment when the spool leaves the center is reached (above 85 % spool stroke).
position (below 15 % spool stroke).
At the switching point the spool is located within the closed
position. It is secured that only the flow paths of the offset
position are granted.

US US
Switch Switch
A-side B-side
Solenoid on Solenoid on Solenoid on Solenoid on
A-side B-side A-side B-side
energized energized energized energized

Switch A-side Switch B-side


0V 0V
-100 % Stroke 0 Stroke +100 % -100 % Stroke 0 Stroke +100 %

Please order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.

D1VW-IPC UK.indd 23.06.2023

2-25 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Performance Curves Series D1VW Inductive Position Control

The flow curve diagram shows the flow versus pressure for each spool type, operating position and flow direction
drop curves for all spool types. The relevant curve number is given in the table below.

Position „b“ Position „a“ Position „0“


Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T

2
001 2 2 2 2 – – – – –
002 1 4 1 4 1 1 5 5 2
003 3 4 3 6 – – 7 – –
004 2 3 2 3 – – 7 7 –
015 3 6 3 4 – – – 7 –
020 B 4 4 2 3 – – – – –
026 B 4 – 4 – – – – – –
030 B 2 3 1 2 – – – – –

Flow curve diagram


24
Pressure drop [bar]

7
20 6
5
16 4
3
12 2
1
8

0
0 20 40 60 80
Flow [l/min]
All characteristic curves measured with HLP46 at 50 °C.

Shift limit diagram


The diagram below specifies the shift limits. Valves with be considerably lower at unbalanced flow conditions. To
spool position “F” or “M” can only be operated up to 70 % avoid flow rates beyond the shift limits, a plug-in orifice
of the limits. The specifications apply to a viscosity of 40 can be inserted in the P-port.
mm2/s and balanced flow conditions. The shift limits can
350
Supply pressure [bar]

001,002
300
020, 030
003, 004, 015
250

200
026
150

100

50

0
0 10 20 30 40 50 60 70 80 90
Flow [l/min]
All characteristic curves measured with HLP46 at 50 °C, 90 % Unom and warm solenoids.

D1VW-IPC UK.indd 23.06.2023

2-26 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Directional Control Valve
Dimensions Series D1VW Inductive Position Control

Interface EN 175301-803, DC solenoid, without plug M12x11)


B, E, F -style
No defined position
Ø9.5 for female connector

93
69
Ø42
22
A B
91.5 Ø5.5
242 46
271.5

H, K, M -style
No defined position
for female connector Ø9.5

93
69
Ø42

22
A B
Ø5.5
134.5
242 46
271.5

Interface EN 175301-803, DC solenoid, without plug M12x12)


C, D -style

Ø9.5
86.5
58.5

22

A B
Ø5.5
132.5
308 46

Surface finish

4x M5x30 7.6 Nm NBR: SK-D1VW-N-91


BK375
ISO 4762-12.9 ±15 % FPM: SK-D1VW-V-91

The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
The space necessary to remove the M12x1 female connector is at least 22 mm.

Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be un-
dertaken by the manufacturer.

1)
Please order plug M12x1 separately (see accessories, plug M12x1; order no.: 5004109).
2)
Please order plug M12x1 separately. Straight plug recommended – no defined position possible for angled plug.

D1VW-IPC UK.indd 23.06.2023

2-27 Parker Hannifin Corporation