Phase 01 B - o
Phase 01 B - o
BRICEof YemenUrban Water Supply and Sanitation Project Water Network for Al-NahdeenIUS-AF-UWS-SAN-021
D B.O.Q
- Supply,
Installati
on and
Constru
ction of
a Water
Distribu
#
tion Description Unit Qty Unit Price (USD)
Total Price
Network
Figures Words (USD)
for Al-
Nahdeen
1 Water Distribution Network
Area
Phase1.1 -1 PIPING AND APPURTENANCES
1.1.1 HDPE Pipe - MAIN LINE
Supply, install, test and commission HDPE pipe PN 16 as specified and shown on drawings including excavation,
cutting asphalt, trench backfill including pipe zone backfill (bedding and embedment), fittings and accessories.
A DN 40 No. 2 0
Total Page (1) -
1.2.3 Washouts
A Supply, install and test washout Type C (main line DN 150) including DN 100 gate valve and dismantling piece No. 1 0
1.2.4 complete with surfaceFilling
Fire Hydrants(Fire box, and all fittings and accessories as specified and shown in the drawings that include the
Points)
supply
Supply, and install fire filling pointsType
and installation of manholes C1 for
including washouts
isolation including
valve, excavation,
pipe from concrete
main line work,valve
to isolation reinforcement,
and all fitting
cover,
and frame, GRP
accessories steps and backfilling all in accordance with the drawings and specifications.
A DN 100 mm Diaas specified and shown in the drawings. No. 1 0
1.2.5 Bulk Water Meters
Supply, install and test propeller type bulk water meter fitted with totalizer including all fittings and accessories as
A specified
DN 150 and shown in the drawings.that include the supply and installation of manholesfor Meters including No. 1 0
1.2.6 excavation, concrete
Single Ferrule Outletwork, reinforcement,
on PE Connectionscover, frame, GRP steps and backfilling all in accordance with the
drawings and specifications.
Supply and install Single ferrule on DI mains including all fittings and accessories as specified and shown on
A drawings
DN 63 mm outlet off DN 180 mm HDPE main No. 2 0
B DN 32 mm outlet off DN 180 mm HDPE main No. 10 0
C DN 25 mm outlet off DN 180 mm HDPE main No. 7 0
1.2.7 Single Ferrule Outlet on PE Connections
Supply and install Single ferrule on PE pipes including all fittings and accessories as specified and shown on
A drawings
DN 63 mm outlet off DN 125 mm HDPE main No. 24 0
B DN 32 mm outlet off DN 125 mm HDPE main No. 155 0
C DN 32 mm outlet off DN 90 mm HDPE main No. 15 0
D DN 32 mm outlet off DN 63 mm HDPE main No. 114 0
E DN 25 mm outlet off DN 125 mm HDPE main No. 75 0
F DN 25 mm outlet off DN 90 mm HDPE main No. 7 0
G DN 25 mm outlet off DN 63 mm HDPE main No. 70 0
Total Page (2) -
1.3 SERVICE CONNECTIONS
1.3.1 Service Connection Assembly
New Service Connection Meters
Supply and install new service connection water meter, including, Water Meter, stop valve, non return stop cock,
A polyethylene coated(in
DN 1/2 inch meter galvanized
one meteriron pipe, Upvc Sleeve pipes, compression adaptor and all necessary pipe and
assembly) No. 210 0
B fittings, excluding meter box, as shown
DN 3/4 inch meter (in one meter assembly) on Drawings. No. 150 0
C DN 1 inch meter (in one meter assembly) No. 120 0
1.3.2 Service connection HDPE pipelines
Supply, install, test and commission HDPE pipe as specified and shown on Drawings including excavation, cutting
A asphalt,
DN 32 mmtrench backfill including pipe zone backfill (bedding and embedment), fittings and accessories.
Dia. M 3200 0
B DN 25 mm Dia. M 3800 0
1.4 RESTORATION OF HARD SURFACES
1.4.1 Reinstatement of asphalt and trenches as specified and shown on Drawings and to the satisfaction of the Engineer. M² 9000 0
Reinstatement of trenches in side walks similar to existing in whatever material such as concrete tiles, concrete
1.4.2 M 370 0
slabs, natural stone, etc.
Total Page (3) -
PRICED B.O.Q - Supply, Installation and Construction of a Water Distribution Network for Al-Nahdeen Area
Unit Price (USD) Total Price
# Description Unit Qty
Figures Words (USD)
2.2 Control Room
2.2.1 Construction Works
A Site Preparation
Dismantling, Removing, and Reinstalling Swings and games that exist within the the implementation site: The contractor must carefully dismantle and remove all existing equipments on the
well site, and reinstall the games as directed by the engineer and the park admin. The work must also include all necessary equipment (crane, trucks, tools, etc.) to execute the task. The
2.2.1.1 LS 1 -
contractor will be expected to replace any item destroyed during the construction process with an equal one at no additional expense to the owner or UNOPS. All work should be completed
in close collaboration with the customer (SWSLC) and the engineer.
Leveling works for well site:
Leveling and removing any obstacles present at the implementation site and get rid of all surpluses. All debris materials shall be disposed of at the approved site as directed by the Engineer.
2.2.1.2 The price includes cleaning the site from all dirt or any unwanted upper soil up to 25 cm and carrying out all appropriate tamping and filling works to obtain the appropriate soil bearing m2 300 -
capacity within (20) tons per square meter. Works also include all that is necessary to finish the work according to the plans, specifications, technical confirmation, workmanship, general and
special conditions, and the instructions of the supervising engineer. .
B WELL/ HEAD CHAMBER WORKS
CONCRETE WORKS
2.2.1.3 Re-install the wellhead and properly install the submersible cables through the wellhead cover, and the work is proceeding with the removal of the installation clamp LS 1 -
Plain concrete works: supply and cast plain concrete (10 cm thick) B200 below ground level with all necessary to complete the work according to designs, specifications, technical assertion
and workmanship, general and particular conditions, and supervision engineer's instructions. (The price includes earthwork and supply, as well as painting two coats of hot pure bitumen
2.2.1.4 m2 5 -
(minimum 2mm thick/layer for each subterranean foundation).
Reinforcement concrete:
Supply and construct rectangular RCC well head chamber, B250 kg/cm2, with internal dimension for its cross section ( 2.6 x1.6 ) m and sufficient total height (up to 1.5m) and 0.2m thick
as shown in drawings and described in the Specifications and directed by the Engineer. The item includes anchored flange spools, three painting layers, one primer coat and two oil paints,
2.2.1.5 with all needed to finish the work according to drawings, specifications, the technical assert & workmanship, general & specific conditions and instructions of the supervisor engineer. m3 3.5 -
Reinforcement concrete:
2.2.1.6 Supply and cast reinforced concrete RCC support for discharge pipe system (valves, water meter, pipe and fittings,..etc.) B250 kg/cm2, with all needed to finish the work according to m3 0.3 -
drawings, specifications, the technical assert & workmanship, general & specific conditions and instructions of the supervisor engineer.
2.2.1.7 Supply and install approved checkered galvanized steel cover ( 2.6 x1.6 ) m using Galvanized steel bars 16mm for the valves chamber, including hinges, hidden hands, lock, frame angels No. 1 -
D … etc., and paint
TRENCHES at leastFOR
WORKS one poly
POWERzinc coat and oneOF
CABLES prime coat and at least two coats of oil paint with all accessories for fixation.
PUMPS
General Notes:
1.The price of blocks works should include supply, testing, placing of approved blocks, workmanship, mortar, and all other required materials, equipment and tools to complete the work according to specifications and directions of supervising
engineer.
2. The solid blocks are used as load bearing units and shall have a block density not less than 1800 kg/ M3. These shall be manufactured for minimum average compressive strengths of 4.0 and 5.0 N/ mm2 respectively.
3.The price includes all works and materials to excute trenches (50cm width x30cm depth) for power cables of submersible pump unit from well head chamber to control Room according according to drawings, specifications, the technical assert
& workmanship, general & specific conditions and instructions of the supervisor engineer.
2.2.1.7 execute all associated earthworks (exacavations,compacting with water spray,..etc..) and installing drain points for cable trenches m 17 -
2.2.1.8 Supply and cast plain concrete (10 cm thick and 50 cm width) ,Grade B200 kg/cm2 . m2 8 -
2.2.1.9 Supply and build a solid cement block (15*20*40 cm) m2 8 -
2.2.1.10 Supply ,cast and install approved RCC slab covers ,B250kg/cm2, size 0.1m (thick)×x 0.5m (w)x L (L=as required ) according to specifications, drawings and the engineer's direction. m 17 -
RCC foundation
Supply, cast outside in open area - RCC foundation B300kg/cm2 for genset. Reinforcement shall be 60 degree threaded with a yield strength of 420 MPa and a rebar diameter of 12mm @
2.2.1.11 20cm as specified in the drawings. The height of this foundation should be 300mm above ground level, or as recommended by the generator set manufacturer, whichever is greater. The m³ 5.4 -
foundation's length and breadth must be at least 250mm greater on all sides than the enclosure's dimensions. For vibration within the box, the generator must be positioned on counter mounts.
The price includes all necessary filling and compaction works to prevent settlement and to achieve the required soil bearing capacity (366 tons).
RCC foundation
Supply, cast outside in open area - a RCC B300 foundation and chamber for fuel tank. Reinforcement shall be 60 degree threaded with a yield strength of 420 MPa and a rebar diameter of
2.2.1.12 m³ 7 -
12mm @ 20cm as specified in the drawings. The works include the adjustment of the tank chamber slope in the direction of the drain valve, and painting the fuel tank chamber with minimum
3 coats of approved epoxy paint, all according to the instructions of the Engineer.
Genset Shed
2.2.1.13 Supply, delivery, erection and installation of the generator steel structure shed. The pricing includes painting columns, sunshades, beams, and purlins, as well as applying two coats of exterior m² 30 -
primer/sealer and two coats of weather protection paint following manufacturer instructions, all to the full satisfaction of the supervising engineer.
Total Page( 2) -
2.2.2 CONTROL ROOM
Earthwork Excavation Works
Earthwork excavation for isolated foundations and strip walls in any kind of soil to the dimensions and levels shown in drawings (at least 1m depth for isolated footing). Price to include
2.2.2.1 backfilling with excavated soil if suitable or substituting same with selected approved imported soil, and removal of extra and unsuitable soil. Back filling shall be on layers of 200 mm thick m³ 14.9 -
with watering and compacting to (95%) of MDD. The item includes Disposing surplus excavated soils outside the site.
Supply and cast reinforced concrete class (C25) including formwork, placing, vibrating, shuttering, curing, complete as directed. The price includes Supplying reinforcement of (Grade 40),
size and length as detailed in the drawings, storing on site including cutting, bending and fixing in position and providing all tying wires, spacers. Item include Preliminary installations for
2.2.2.5
electrical pips and floor drainage in concrete beams, and any concrete elements wherever required. The price include surface leveling, making good the harmed surfaces and edges and all
surface finishing as per workmanship recommendations. For the following elements
Isolated foundation and pedestal. item include 10 cm plain concrete under RC footing. The work includes painting two coats of water proofing bituminous for foundation surfaces. The
2.2.2.6 reinforcement concrete surface should be covered using of three coats of bituminous protection (to all external surface of reinforcement concrete), in addition to that all surface of m³ 4.0 -
reinforcement concrete which are above the ground level should be painted with two layer of painting of grey or white color as per in the shop drawings.
Windows Works
2.2.2.19 Aluminum sliding window (1.2 x 1 m) with 6 mm dark glass , complete with two sliding leaves complete , glazing , silicone sealant , Ironmonger and hardware , all and anywhere else , m² 2.4 -
needed , all according to and all necessary related work according to the instructions of the supervising Engineer.
Window Steel Protection ( Anti burglar bars )
Supply and install Steel metal grille for window protection with all required works. 12mm di Steel bars decorative (standard shape), approx. spacing between bars about 12cm in the two
2.2.2.20 directions, the window edges angle (L- section) 4cmx 4cmx3mm. Providing panting with primer paint and approved color, and all to the full satisfaction of Engineer. The price included any m² 2.4 -
work and all accessories to finish work as directed by the engineer.
DOOR WORK
2.2.2.21 Supply, fix and install single external steel door size (2x1.2m) made out steel tubes adjoining vertically without space (tube 50x50x1.25 mm), No 1.0 -
complete with frame (L section 50x50x0.4), item includes all accessories, handles, locks, hinges and all required accessories according to the instructions of supervisor Engineer.
2.2.2.22 ELECTRICAL WORK No 1.0 -
Supply and install, test and commission ,(4 indoor LED light fixture 20 W), (8 Outdoor LED light fixture 30 W), and 4 (13A wall-mount switched single socket for
2.2.2.23 general use) the price includes, the panel, switches, wires, conduits, accessories, fixing materials, and all civil and other works L.S 1.0 -
needed to complete the works.All in accordance with the specifications, drawings and approval of the Engineer
Total Page(4) -
2.2.3 EXTERNAL WALL
Earthwork Excavation Works
Earthwork excavation for isolated foundations and strip walls in any kind of soil to the dimensions and levels shown in drawings (at least 1m depth for isolated footing). Price to include
2.2.3.1 backfilling with excavated soil if suitable or substituting same with selected approved imported soil, and removal of extra and unsuitable soil. Back filling shall be on layers of 200 mm thick m³ 14.5 -
with watering and compacting to (95%) of MDD. The item includes Disposing surplus excavated soils outside the site.
Supply and cast reinforced concrete class (C25) including formwork, placing, vibrating, shuttering, curing, complete as directed. The price includes Supplying reinforcement of (Grade 40),
size and length as detailed in the drawings, storing on site including cutting, bending and fixing in position and providing all tying wires, spacers. Item include Preliminary installations for
2.2.3.5 electrical pips and floor drainage in concrete beams, and any concrete elements wherever required. The price include surface leveling, making good the harmed surfaces and edges and all
surface finishing as per workmanship recommendations. For the following elements
Isolated foundation and pedestal. item include 10 cm plain concrete under RC footing. The work includes painting two coats of water proofing bituminous for foundation surfaces. The
2.2.3.6 reinforcement concrete surface should be covered using of three coats of bituminous protection (to all external surface of reinforcement concrete), in addition to that all surface of m³ 1.4 -
reinforcement concrete which are above the ground level should be painted with two layer of painting of grey or white color as per in the shop drawings.
3
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.7
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.2.9
3.2.10
3.2.11
3.2.11.1
3.2.11.2
3.2.11.3
3.2.11.4
B.O.Q - Supply, Installation and Construction of a Water Distribution Network and Elevated Tank for Al-Nahdeen Area
Description Unit
Supply, Delevary, Iistalling, and Comissioning of Sound-Proof Prime Power ,silence inside container Diesel Generator for Water
Well Station ,(2300 Mtr Altitude)
• 350 KVA, 3 phase,4Wire, 380-415 V, 50 Hz, 1500 RPM,
• Diesel engine complete with its accessories.
• Alternator, self-excited.
• Steel base-plate complete with anti vibrators, bolts and nuts.
• Voltage regulator complete with adjusting rheostat.
• Control, instrument, meters and indicators panel board
• Speed governor. Set
• Water cooling system.
• Inlet air system.
• Exhaust system.
• hand operated oil drain pump 25L, 100 cc/cycle with all accessories.
• Operating and Service Manuals.
Fuel Tank:
Supply and delivery of a complete elevated outdoor daily Steel Fuel tank with a capacity of 5000 L and a thickness not less than 5
mm, including a Sight Glass Level Measurement (Gauge) and all necessary fuel pipes, fittings, valves, filters, flow meter up to 4
ℓ/sec, suitable for diesel service, instruments and all accessories for connection to the genset base fuel tank. The tank must be applied Set
with two layers of epoxy outside and three layers inside.
ATS:
▪Supply, Installing, testing, and Commissioning Complete Motorized and Auto-Transfer Switch (ATS) , Two way ATS type with
all required accessories, according to technical specification and shop drawing. including:
▪ IP 54 for outdoor installation
▪ Ue 400/415 , Ie 630 A.
▪ Isc ; 50KA Set
▪ 4 Pole.
▪ Vertical mounting type.
▪ Product integration in compliance with IEC / EN 61439, Rated operational currents Ie (A) according to IEC 60947.
MDB :
-Supply and install a Threephase, low voltage main control distribution board , 4poles CU. busbars 800A ,50KA, Enclosure material
galvanized steel sheets, complete unit , and all accessories and requirements acc. To specifications, drawings.
It includes:-
- 4poles CU Busbars 800A ,50KA
- MCCB: (630 ,300,100 and 63)A , 4P, Isc 50KA No.
- MCB: ( 40 and 3*10)A & ELCB (10)A
- Enclosure Ingress protection IP-54;
- Warranty: at least 1 year.
Cables:
Supply, laying, glanding, and termination of the following cables including excavation and backfilling of tranches in any kind of soil
including conduits, warning tapes, cable glands, sealing boxes, termination, cable and all accessories. m
- Power Armored copper Cables : CU/XPLE/SAW/PVC 1.0KV Size (4X1cX150) SQ.mm
Total Page(2)
Earthing System:
Supply and delivery of a complete earthing system for the Genset, ATS and Electrical Pump Inverter, including all conductors,
copper bars tap-clamps, fixing, earthing pits, manhole …etc. The design of the system and all items shall be according to BS 7430
and ANSI IEEE Std 80 to obtain required earth resistance less than (3 Ω), all of which shall be according to the specifications, codes
of practice and highest prevailing engineering standards for the following main system component:
a. Extendible copper electrodes, (suggested length 1.6~2.4 m).
b. Main earthling cable: copper bared 70 mm², earthling cables for gensets, hanger frame and any other equipment: insulated cooper Set
35 mm², Copper earthing bar, Earth pit with manhole cast iron cover plate complete as per standard, the cover of the manhole is
preferred to be clearly stamped with grounding sign.
c. Ground Enhancement Material (Bentonite).
d. Earthing busbar shall be protected fixed inside sealed box.
Supply ,install ,test and commissioning 5kg Carbon Dioxide (CO2)Extinguisher No.
Supply ,Install ,test and commissioning 6kg Powder Extinguisher No.
Supply, install and commissioning Smoke and Heat Detector:
Smoke and heat detector, stand-alone battery type including button for false alert. Battery for three years long life, warning sound No.
delivers sounds of >85 dBAs per related RFQ documents.
Supply and delivery of a Repair Tool kit that is manufacturer-recommended and suited for use with any potential service and
maintenance issues.
Note
1 -
1 -
1 -
1350 -
450 -
67 -
69 -
1 -
1 -
1 -
1 -
2 -
2 -
-
1 -
1 -
1 -
1 -
30 -
-
1 -
2 -
2 -
2 -
10 -
20 -
10 -
1000 -
-