DAC basic/classic
Parameter list
969
0791 969901
                    VB02.6
All rights reserved.
Property of Dürkopp Adler GmbH and protected by copyright. Any reuse of
these contents, including extracts, is prohibited without the prior written ap-
proval of Dürkopp Adler GmbH.
Copyright © Dürkopp Adler GmbH 2022
Parameter list
 Table of Contents
 1   Parameter ........................................................................................................... 5
 1.1 Operator level ..................................................................................................... 5
     Bobbin stitch counter/ remaining thread monitor/piece counter .......................... 5
     Needle cooling/fan .............................................................................................. 6
     Light barrier ......................................................................................................... 6
     Stitch loosening device ....................................................................................... 6
 1.2 Technician level .................................................................................................. 7
     Thread clamp (TC) ............................................................................................ 10
     Thread cutter (FA)............................................................................................. 12
     Sewing foot lift (FL) ........................................................................................... 13
     Soft start ........................................................................................................... 14
     Remaining thread monitor/bobbin rotation monitor/skip stitch detector............. 14
     Needle thread monitor up ................................................................................. 14
     Needle thread monitor down ............................................................................. 15
     Seam paths ....................................................................................................... 15
     Motor ................................................................................................................. 15
     Thread tension .................................................................................................. 18
     Stroke adjustment ............................................................................................. 20
     Function module ............................................................................................... 21
     Reversal ............................................................................................................ 24
     Needle cooling/fan ............................................................................................ 24
     Carrier roller/puller/seam middle guide ............................................................. 25
     Edge cutter ....................................................................................................... 27
     Light barrier ....................................................................................................... 27
     Electronic handwheel ........................................................................................ 28
     Stacker.............................................................................................................. 28
     Zigzag ............................................................................................................... 29
     Thread wiper ..................................................................................................... 29
     Step cutting/contour guide ................................................................................ 29
     Outfeed roller .................................................................................................... 29
     Hook lubrication ................................................................................................ 29
     Stitch loosening device ..................................................................................... 30
     Tape Cutter ....................................................................................................... 30
     Stitch length switching ...................................................................................... 31
     Stitch shortening ............................................................................................... 31
     Operation lock ................................................................................................... 31
     Control, other .................................................................................................... 31
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                                                        3
                                                                                                       Parameter list
    OP1000 ............................................................................................................. 38
1.3 Developer level ................................................................................................. 40
    Thread cutter (FA)............................................................................................. 40
    Seam paths ....................................................................................................... 41
    Motor ................................................................................................................. 41
    Thread tension .................................................................................................. 42
    Top puller .......................................................................................................... 42
    Bottom puller ..................................................................................................... 43
    Control, other .................................................................................................... 44
2   Error, warning and information messages ........................................................ 47
4                                  DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
 1      Parameter
 The parameter list helps the user quickly locate and change a parameter.
 Some parameters have been grouped into categories which can be found on sev-
 eral levels and reflect their importance and their resulting minor or major effect on
 the sewing behavior of the machine.
 Class parameters 969
               Class:                        969
               Parameter set:
               For subclasses:               969-190180
 1.1     Operator level
  E C     P      Min      Max       Preset      Unit         Description
                                    value
  Bobbin stitch counter/ remaining thread monitor/piece counter
  o 06    00     0        4         0           -            Bobbin stitch counter / remaining
                                                             thread monitor
                                                             0 = Off;
                                                             1 = Bobbin stitch counter A;
                                                             2 = Bobbin stitch counter B;
                                                             3 = Bobbin stitch counter C;
                                                             4 = Remaining thread monitor
  o 06    01     1        9999      3000        x o0604      Reset value of bobbin stitch
                                                             counter A
  o 06    02     1        9999      2000        x o0604      Reset value of bobbin stitch
                                                             counter B
  o 06    03     1        9999      1000        x o0604      Reset value of bobbin stitch
                                                             counter C
  o 06    04     1        255       10          x stitches   Factor of bobbin stitch counters
                                                             A, B and C
  o 06    05     0        9999      0           Stitches     Number of stitches for the re-
                                                             maining thread monitor
  o 06    06     0        1         1           -            Stop sewing motor when the
                                                             counter reaches 0
                                                             0 = Off;
                                                             1 = On
  o 06    07     0        1         1           -            Sewing foot stays down after
                                                             thread cutting
                                                             0 = Off;
                                                             1 = On
  o 06    08     0        1         0           -            When a counter has elapsed, a
                                                             reset must occur after thread
                                                             cutting
                                                             0 = Off;
                                                             1 = On
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                            5
                                                                            Parameter list
E C    P    Min      Max         Preset       Unit        Description
                                 value
o 06   10   0        1           0            -           Display of the piece counter
                                                          0 = Off;
                                                          1 = On
o 06   20   0        1           0            -           Needle thread monitor up
                                                          0 = Off;
                                                          1 = On
o 06   30   0        1           0            -           Needle thread monitor down
                                                          0 = Off;
                                                          1 = On
Needle cooling/fan
o 13   00   0        1           0            -           Needle cooling
                                                          0 = Off;
                                                          1 = On
Light barrier
o 16   00   0        255         0            Stitches    Equalizing stitches for normal
                                                          stitch length
o 16   01   0        255         0            Stitches    Equalizing stitches for long stitch
                                                          length
o 16   10   1        255         1            Seams       Number of light barrier seams
o 16   20   0        255         0            Stitches    Equalizing stitches for knitted
                                                          garment filter
Stitch loosening device
o 25   00   0        2           0            -           Mode of automatic stitch loosen-
                                                          ing device
                                                          0 = Only stitch loosening;
                                                          1 = Stitch loosening and 2nd
                                                          stitch length;
                                                          2 = Stitch loosening, 2nd stitch
                                                          length, and quick stroke adjust-
                                                          ment;
6                        DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
 1.2       Technician level
  E C       P    Min      Max       Preset      Unit         Description
                                    value
  Bartack
  t   00    00   300      6000      500         rpm          Start bartack speed
  t   00    01   0        254       5           10°          Feed-forward angle when the
                                                             bartack magnet is switched on
                                                             (Switching from forward to back-
                                                             ward during bartacking)
  t   00    02   0        254       17          10°          Forward-feed angle when the
                                                             bartack magnet is switched off
                                                             (Switching from backward to
                                                             forward during bartacking)
  t   00    03   0        1         0           -            Start bartack can be interrupted
                                                             by setting pedal to 0 position
                                                             0 = Off;
                                                             1 = On
  t   00    04   0        2         0           -            Mode for end of start bartack
                                                             0 = Sewing continues after end;
                                                             1 = Machine stops and must be
                                                             restarted using the pedal;
                                                             2 = Thread cutting after start
                                                             bartack
  t   00    05   0        1         1           -            Pedal release only after addition-
                                                             al A path
                                                             0 = Off;
                                                             1 = On
  t   00    06   0        500       0           ms           Delay time to speed release after
                                                             start bartack
  t   00    07   0        255       0           ms           Fall time of bartack magnet
  t   00    09   0        1         0           -            Additional forward path at start
                                                             bartack with the number of back-
                                                             ward stitches
                                                             0 = Off;
                                                             1 = On
  t   00    10   300      6000      500         rpm          End bartack speed
  t   00    11   0        254       9           10°          Feed-forward angle when the
                                                             bartack magnet is switched on
                                                             (Switching from forward to back-
                                                             ward during bartacking)
  t   00    12   0        254       17          10°          Forward-feed angle when the
                                                             bartack magnet is switched off
                                                             (Switching from backward to
                                                             forward during bartacking)
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                             7
                                                                           Parameter list
E C      P    Min   Max         Preset       Unit        Description
                                value
t   00   13   0     1           0            -           Bartack magnet stays switched
                                                         on during the last backward path
                                                         (simple end bartack and multiple
                                                         end bartack) until position 2 has
                                                         been reached
                                                         0 = Off;
                                                         1 = On
t   00   19   0     1           0            -           Additional forward path at end
                                                         bartack with the number of back-
                                                         ward stitches
                                                         0 = Off;
                                                         1 = On
t   00   20   300   6000        500          rpm         Multiple start bartack speed (only
                                                         during darning program)
t   00   21   0     254         16           10°         Feed-forward angle when the
                                                         bartack magnet is switched on
                                                         (Switching from forward to back-
                                                         ward during bartacking) (only
                                                         during darning program)
t   00   22   0     254         22           10°         Forward-feed angle when the
                                                         bartack magnet is switched off
                                                         (Switching from backward to
                                                         forward during bartacking) (only
                                                         for darning program)
t   00   23   0     3           0            -           Multiple start bartack as darning
                                                         program
                                                         0 = Off;
                                                         1 = On
t   00   24   0     1           0            -           Pedal-dependent speed for
                                                         darning program
                                                         0 = Off;
                                                         1 = On
t   00   25   0     1           0            -           First path with different number of
                                                         stitches (C) in multiple start
                                                         bartack
                                                         0 = Off;
                                                         1 = On
t   00   26   0     1           0            -           Last path with different number of
                                                         stitches (B) in multiple end
                                                         bartack
                                                         0 = Off;
                                                         1 = On
t   00   30   0     1           1            -           Ornamental-stitch bartack
                                                         0 = Off;
                                                         1 = On
t   00   31   0     2500        500          rpm         Speed of ornamental-stitch
                                                         bartack
t   00   32   0     1000        100          ms          Ending time during ornamental-
                                                         stitch bartack
8                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   00   35    0        1         1           -            Speed decrease when feed dog
                                                             is repositioned
                                                             0 = Off;
                                                             1 = On
  t   00   36    0        6000      500         rpm          Level to which the speed is
                                                             supposed to be reduced when
                                                             the feed dog is repositioned
  t   00   40    0        2         1           -            Type of start bartack when the
                                                             bartack activation switch is en-
                                                             gaged
                                                             0 = Simple start bartack;
                                                             1 = Double start bartack;
                                                             2 = Multiple start bartack
  t   00   41    0        2         1           -            Type of end bartack when the
                                                             bartack activation switch is en-
                                                             gaged
                                                             0 = Simple end bartack;
                                                             1 = Double end bartack;
                                                             2 = Multiple end bartack
  t   00   44    0        3         0           -            Handling of manual bartack
                                                             0 = Manual bartack engages
                                                                   immediately;
                                                             1 = Manual bartack engages
                                                                   depending on parameters t
                                                                   00 45 and t 00 46;
                                                             2 = During manual bartacking,
                                                                   the drive stops in the posi-
                                                                   tion set under parameters
                                                                   t 00 45 and t 00 46;
                                                             3 = During manual bartack-
                                                                  ing, the drive stops in the
                                                                  position set under pa-
                                                                  rameters t 00 45 and
                                                                    t 00 46
                                                                    (only if parameter t 00 30 =
                                                                    1)
  t   00   45    0        1         0           -            Switch on the manual bartack
                                                             0 = Needle down;
                                                             1 = Needle up
  t   00   46    0        1         0           -            Switch off the manual bartack
                                                             0 = Needle down;
                                                             1 = Needle up
  t   00   47    0        3         0           -            Speed limit for manual bartack
                                                             0 = Off;
                                                             1 = Limit to DB3000 if
                                                             t 00 44 = 0 – 1
                                                             2 = Limit to ornamental-stitch
                                                             bartack speed
                                                             if t 00 44 = 2 – 3
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                              9
                                                                               Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    00   50   0     999         100          ms          Activation time of bartack magnet
                                                          in period t1
t    00   51   5     100         100          %           Duty cycle in period t1
t    00   52   0,0   600,0       0,0          s           Activation time of bartack magnet
                                                          in period t2 (if 0, the bartack
                                                          magnet remains continuously
                                                          switched on)
t    00   53   5     100         100          %           Duty cycle in period t2
t    00   54   0     1           0            -           Increase in Umag when the
                                                          bartack magnet is activated
                                                          0 = No;
                                                          1= Yes
t    00   60   0     359         73           °           Angle at which the feed dog
                                                          repositioner is to supposed
                                                          switch
t    00   61   0     200         14           ms          Switch on inertia
t    00   62   0     200         16           ms          Switch off inertia
t    00   63   0     1           0            -           Switch feed dog repositioner
                                                          depending on angle
                                                          0 = No;
                                                          1= Yes
t    00   70   0     255         0            Stitches    Catch Backtack forward
t    00   71   0     255         0            Stitches    Catch Backtack backward
Thread clamp (TC)
t    01   00   0     10          8            -           Mode of thread clamp
                                                          0 = TC switch-on angle =
                                                              t 01 01,
                                                              TC switch-off angle =
                                                              t 01 02,
                                                              Without FL;
                                                          1 = TC switch-on angle = 108°,
                                                              TC switch-off angle = 268°,
                                                              Without FL;
                                                          2 = TC switch-on angle = 49°,
                                                              TC switch-off angle = 110°,
                                                              Without FL;
                                                          3 = TC switch-on angle = 49°,
                                                              TC switch-off angle = 190°,
                                                              Without FL;
                                                          4 = TC switch-on angle = 108°,
                                                              TC switch-off angle = 268°,
                                                              FL switch-on angle = 108°,
                                                              FL switch-off angle = 154°;
                                                          5 = TC switch-on angle = 108°,
                                                              TC switch-off angle = 268°,
                                                              FL switch-on angle = 44°,
                                                              FL switch-off angle = 154°;
10                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
                                                             6 = TC switch-on angle = 75°,
                                                                  TC switch-off angle = 215°,
                                                                  FL switch-on angle = 60°,
                                                                  FL switch-off angle = 120°,
                                                                  FL switch-off angle, addi-
                                                                  tionally stroke-dependent;
                                                             7 = Without TC,
                                                                  FL switch-on angle =
                                                                  t 01 11,
                                                                  FL switch-off angle =
                                                                  t 01 12,
                                                             8 = TC switch-on angle =
                                                                  t 01 01,
                                                                  TC switch-off angle =
                                                                  t 01 02,
                                                                  FL switch-on angle =
                                                                  t 01 11,
                                                                  FL switch-off angle FL =
                                                                  t 01 12;
                                                             9 = Without TC,
                                                                  FL switch-on angle =
                                                                  t 01 11,
                                                                  FL switch-off angle =
                                                                  t 01 12,
                                                                  FL switch-off angle, addi-
                                                                  tionally stroke-dependent;
                                                             10 = TC switch-on angle =
                                                                  t 01 01,
                                                                  TC switch-off angle =
                                                                  t 01 02,
                                                                  FL switch-on angle =
                                                                  t 01 11,
                                                                  FL switch-off angle =
                                                                  t 01 12,
                                                                  FL switch-off angle, addi-
                                                                  tionally stroke-dependent;
  t   01   01    0        359       75          °            Switch-on angle of thread clamp
  t   01   02    0        359       215         °            Switch-off angle of thread clamp
  t   01   11    0        359       60          °            Switch-on angle of sewing foot lift
  t   01   12    0        359       120         °            Switch-off angle of sewing foot lift
  t   01   13    0        100       100         %            Duty cycle of sewing foot lift in
                                                             mode 4-8
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                            11
                                                                             Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    01   20   0     3           3            -           Thread clamp options
                                                          0 = Thread clamp only at seam
                                                          beginning;
                                                          1 = Thread clamp at seam begin-
                                                          ning and during reverse;
                                                          2 = Thread clamp at seam begin-
                                                          ning and during sewing foot lift;
                                                          3 = Thread clamp at seam begin-
                                                          ning and during reverse and
                                                          sewing foot lift
t    01   30   0     2           0            -           Neat seam beginning (NSB)
                                                          0 = Off;
                                                          1 = On when thread clamp is
                                                          active (old mode);
                                                          2 = On when thread clamp is
                                                          active (new mode)
t    01   31   0     9999        92           ° / ms      Switch-on angle of additional
                                                          thread clamp (o.m.) / Switch-on
                                                          time knife (n.m.)
t    01   32   0     9999        201          °           Switch-off angle of additional
                                                          thread clamp
t    01   33   0     9999        105          °           Switch-on angle of thread ad-
                                                          vancing device
t    01   34   0     9999        203          ° / 10 ms   Switch-off angle of thread ad-
                                                          vancing device (o.m.) / Time
                                                          duration of suction (n.m.)
t    01   35   0     9999        62           °           Switch-on angle of thread tension
                                                          lift
t    01   36   0     9999        94           °           Switch-off angle of thread tension
                                                          lift
t    01   50   0     999         100          ms          Activation time of thread clamp in
                                                          period t1
t    01   51   5     100         100          %           Duty cycle in period t1
t    01   52   0,1   120,0       60,0         s           Activation time of thread clamp in
                                                          period t2 (if 0, the thread clamp
                                                          remains continuously switched
                                                          on)
t    01   53   5     100         30           %           Duty cycle in period t2
t    01   54   0     1           0            -           Increase in Umag when the thread
                                                          clamp is activated
                                                          0 = No;
                                                          1= Yes
Thread cutter (FA)
t    02   00   50    750         75           rpm         Speed when cutting the thread
t    02   01   0     1           0            -           Pedal position for initiating the
                                                          cutting process
                                                          0 = Position -2;
                                                          1 = Position -1
12                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   02   02    0        1         0           -            Initiate seam end at seam begin-
                                                             ning (with single stitch functions
                                                             activated)
                                                             0 = No;
                                                             1= Yes
  t   02   10    0        359       33          °            Switch-on angle t 08 12 <= t 02
                                                             10 < t 02 11
  t   02   11    0        359       170         °            Switch-off angle t 02 10 < t 02 11
                                                             <= t 08 13
  t   02   20    0        255       0           ms           Delay time for repeated switch-on
                                                             of thread cutting magnet
  t   02   21    0        255       0           ms           Delay time for switch-off of thread
                                                             cutting magnet
  t   02   50    0        999       500         ms           Activation time of thread cutter in
                                                             period t1
  t   02   51    5        100       100         %            Duty cycle in period t1
  t   02   52    0,1      120,0     10,0        s            Activation time of thread cutter in
                                                             period t2 (if 0, the thread clamp
                                                             remains continuously switched
                                                             on)
  t   02   53    5        100       100         %            Duty cycle in period t2
  t   02   54    0        1         0           -            Increase in Umag when thread
                                                             cutter is activated
                                                             0 = No;
                                                             1= Yes
  t   02   55    0        359       250         °            Angle at which duty cycle 2 is
                                                             activated (0 = deactivated)
  Sewing foot lift (FL)
  t   03   00    0        1         1           -            Sewing foot lift
                                                             0 = Off;
                                                             1 = On
  t   03   01    0        1         0           -            No sewing start over push-botton
                                                             while the sewing foot is lifted
                                                             0 = Off;
                                                             1 = On
  t   03   10    0        9999      80          ms           Startup delay of machine after
                                                             sewing foot lift is switched off
  t   03   11    0        255       40          ms           Activation delay of sewing foot lift
                                                             during a machine standstill
  t   03   12    0,0      9,999     0,600       s            Activation delay of sewing foot lift
                                                             at seam end
  t   03   50    0        999       200         ms           Activation time of sewing foot lift
                                                             magnet in period t1
  t   03   51    5        100       100         %            Duty cycle in period t1
  t   03   52    0,0      600,0     0,0         s            Activation time of sewing foot lift
                                                             magnet in period t2 (if 0, the
                                                             sewing foot lift magnet remains
                                                             continuously switched on)
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                          13
                                                                             Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    03   53   5     100         100          %           Duty cycle in period t2
t    03   54   0     1           0            -           Increase in Umag when sewing
                                                          foot lift magnet is activated
                                                          0 = No;
                                                          1= Yes
t    03   55   0     1           0            -           Activation sound warning before
                                                          foot is automatically lowered
                                                          0 = No;
                                                          1 = Yes
Soft start
t    05   00   120   1000        200          rpm         Soft start speed
t    05   01   1     99          1            Stitches    Number of soft start stitches
Remaining thread monitor/bobbin rotation monitor/skip stitch detector
t    06   00   0     2           0            -           Activation of the remaining thread
                                                          monitor
                                                          0 = Off;
                                                          1 = Right;
                                                          2 = Left & right;
t    06   01   0     1           0            -           Remaining thread monitor mode
                                                          0 = Dynamic;
                                                          1 = Static;
t    06   02   0,0   3,300       0,0          V           Threshold right
t    06   03   0,0   3,300       0,0          V           Intensity right
t    06   04   0,0   3,300       0,0          V           Threshold left
t    06   05   0,0   3,300       0,0          V           Intensity left
t    06   06   0     1           0            -           Confirmation necessary by mes-
                                                          sages
                                                          0 = no;
                                                          1 = yes
t    06   10   0     1           0            -           Skip stitch detector
                                                          (Not if t 06 00 = 2)
                                                          0 = Off;
                                                          1 = On
t    06   11   0     1           0            -           Bobbin rotation monitor
                                                          (Not if t 06 00 = 2)
                                                          0 = Off;
                                                          1 = On
t    06   12   0     255         0            Stitches    Number of stitches at which the
                                                          bobbin rotation monitor is acti-
                                                          vated
t    06   13   0     5000        0            ms          Cleaning time SSD after FA
Needle thread monitor up
t    06   20   0     1000        180          rpm         Speed at which the monitor is
                                                          activated
14                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   06   21    0        255       2           Stitches     Number of stitches at which the
                                                             monitor is activated
  t   06   22    0        1000      3           ms           Debouncing
  Needle thread monitor down
  t   06   30    0        1000      180         rpm          Speed at which the monitor is
                                                             activated
  t   06   31    0        255       2           Stitches     Number of stitches at which the
                                                             monitor is activated
  t   06   32    0        1000      3           ms           Debouncing
  Seam paths
  t   07   00    0        2         0           -            Handling of position -2 for seam
                                                             paths
                                                             0 = Cancellation of the seam.
                                                                  The next seam path is
                                                                  sewn; the last seam of the
                                                                  program is canceled with
                                                                  thread cutting;
                                                             1 = Termination of the seam
                                                                  with thread cutting (even if
                                                                  not active). The next seam
                                                                  procedure is a free seam;
                                                             2 = Termination of the seam
                                                                  with thread cutting (even if
                                                                  not active). Seam program
                                                                  is canceled
  t   07   01    0        1         0           -            Automatic mode
                                                             0 = Off;
                                                             1 = On
  t   07   02    0        1         0           -            Signal on switch of path
                                                             0 = Off;
                                                             1 = On
  t   07   03    0        1         0           -            Repair mode
                                                             0 = Off;
                                                             1 = On
  t   07   04    0        1         0           -            Mode for cycling the sewing
                                                             program
                                                             0 = Off;
                                                             1 = On
  t   07   05    0        1         0           -            Possibility to start sewing from
                                                             the edited segment
                                                             0 = Off;
                                                             1 = On
  Motor
  t   08   00    500      9999      1000        rpm          Maximum speed
  t   08   01    10       400       75          rpm          Minimum speed
  t   08   02    10       1000      75          rpm          Positioning speed
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                            15
                                                                             Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    08   03   1     100         10           rpm/ms      Acceleration ramp
t    08   04   1     100         10           rpm/ms      Deceleration ramp
t    08   05   0     1           0            -           Direction of rotation of motor
                                                          0 = Left;
                                                          1 = Right
t    08   06   0     2           1            -           Motor brake during normal stop
                                                          0 = Braking for period of t 08 09;
                                                          1 = Brake continuously active
                                                          when stopped;
                                                          2 = Position is continuously
                                                          maintained
t    08   07   0,1   6,0         0,7          A           No-damage current when ma-
                                                          chine down
t    08   08   0     255         30           -           Response time to changes in
                                                          position
t    08   09   0     999         200          ms          Duration of motor brake
t    08   10   -     -           -            -           Reference position
t    08   11   -     -           -            -           Needle positions
t    08   12   0     359         115          °           Needle in the low position (bot-
                                                          tom dead center) (position 1)
t    08   13   0     359         310          °           Thread lever at top dead center
                                                          (position 2)
t    08   14   0     359         163          °           Point position
t    08   15   0     359         213          °           Threading position (needle
                                                          thread)
t    08   16   0     1           0            -           Drive to bearing position via
                                                          pedal
t    08   19   1     9999        359          -           Transmission ratio =
                                                          (motor diameter / machine diam-
                                                          eter) * 1000
t    08   20   -     -           -            -           Calibrate pedal
t    08   21   1     64          24           Levels      Number of speed levels of pedal
t    08   22   0     7           3            -           Speed curve
t    08   23   1     255         90           ms          Debouncing of position -1
t    08   24   1     255         15           ms          Debouncing of position -2
t    08   25   0     1           0            -           Selection of pedal
                                                          0 = Analog;
                                                          1 = Digital
t    08   26   0     1           0            -           Inverting signals of the digital
                                                          pedal
                                                          0 = No;
                                                          1 = Yes (Efka pedal with adapter)
16                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   08   27    0        2         0           -            Handling of position -1 (only with
                                                             digital pedal)
                                                             0 = Not stored;
                                                             1 = Stored;
                                                             2 = Stored after Thread Trim, not
                                                             stored after sewstart
  t   08   28    40       70        60          -            Factor of position -1
                                                             This parameter can be used to
                                                             adjust the response between -1
                                                             and 0
  t   08   29    20       70        49          -            Factor of position -2
                                                             This parameter can be used to
                                                             adjust the response between -2
                                                             and 0
  t   08   30    0        1         0           -            Display of speed
                                                             0 = Off;
                                                             1 = On
  t   08   31    0        1         0           -            Display of current position
                                                             0 = Off;
                                                             1 = On
  t   08   32    0        1         0           -            After power-on and a tap on the
                                                             pedal, the needle is moved to the
                                                             "Needle up" position
                                                             0 = No;
                                                             1= Yes
  t   08   33    0        6         0           -            Output of position signals (signal
                                                             must be assigned to an output,
                                                             e.g. t 51 50)
                                                             0 = No signals are output;
                                                             1 = Pos. 1;
                                                             2 = Pos. 2;
                                                             3 = Pos. 1 & Pos. 2;
                                                             4 = Motor operation signal;
                                                             5 = Motor operation signal &
                                                             Pos. 1;
                                                             6 = Motor operation signal &
                                                             Pos. 2
  t   08   34    0        255       0           °            Angle for the length of the Pos. 1
                                                             signal
  t   08   35    0        255       0           °            Angle for the length of the Pos. 2
                                                             signal
  t   08   36    10       9999      10          rpm          Speed at which the motor opera-
                                                             tion signal is activated
  t   08   37    0        359       0           °            Position 3 (only output position)
  t   08   38    0        255       0           °            Angle for the length of the Pos. 3
                                                             signal ( > 0 output is activated)
  t   08   40    150      9999      800         rpm          Speed limit DB3000
  t   08   41    150      9999      1800        rpm          Speed limit DB2000
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         17
                                                                              Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    08   44   1     255         40           ms          Debouncing of position 0
t    08   50   10    500         180          rpm         Preset speed value for single
                                                          stitch functions (half or full stitch,
                                                          etc.)
t    08   51   1     6000        180          rpm         Speed for manual sewing per
                                                          push button
t    08   52   0     1           0            -           Sewing functions via push button
                                                          also in manual mode
                                                          0 = No;
                                                          1= Yes
t    08   60   0     64          0            Level       Shifting of position 1
                                                          Number of speed levels is re-
                                                          duced
Thread tension
t    09   00   0     3           2            °           Mode of thread tension and
                                                          thread tension reduction when
                                                          sewing foot lift is active
                                                          0 = no thread tension lift;
                                                          1 = Thread tension lift in the
                                                          seam;
                                                          2 = Thread tension lift after
                                                          thread cutting;
                                                          3 = Thread tension lift in the
                                                          seam and after thread cutting
t    09   01   0     1           0            °           Thread tension with threader
                                                          (needle thread) lifted
                                                          0 = No;
                                                          1= Yes
t    09   02   0,0   2,55        1,00         s           Activation delay of thread tension
                                                          lift after thread cutting when
                                                          sewing foot is lifted (only active if
                                                          t 09 00 = 2 or 3)
t    09   03   0     2           0            °           Coupling of additional thread
                                                          tension with quick stroke adjust-
                                                          ment
                                                          0 = no coupling;
                                                          1 = Additional thread tension
                                                          during quick stroke adjustment;
                                                          2 = Additional thread tension
                                                          when quick stroke adjustment
                                                          speed is reached
t    09   10   0     359         175          °           Switch-on angle t 08 12 <= t 09
                                                          10 < t 09 11 during cutting pro-
                                                          cess
t    09   11   0     359         280          °           Switch-off angle t 09 10 < t 09 11
                                                          <= t 08 13 during cutting process
t    09   20   0     255         0            ms          Delay time for repeated switch-on
                                                          of thread tension magnet during
                                                          cutting process
18                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   09   21    0        255       50          ms           Delay time for switch-off of thread
                                                             tension magnet
  t   09   30    0        1         0           -            Open additional thread tension
                                                             during start bartacking
                                                             0 = No;
                                                             1 = Yes;
  t   09   31    0        1         0           -            Open additional thread tension
                                                             during end bartacking
                                                             0 = No;
                                                             1 = Yes;
  t   09   32    0        1         0           -            Open additional thread tension
                                                             during manual bartacking
                                                             0 = No;
                                                             1 = Yes;
  t   09   33    0        1         0           -            Open additional thread tension
                                                             for thread clamp
                                                             0 = No;
                                                             1 = Yes;
  t   09   34    0        1         0           -            Open additional thread tension
                                                             during soft start
                                                             0 = No;
                                                             1 = Yes;
  t   09   35    0        1         0           -            Open additional thread tension
                                                             during stitch shortening
                                                             0 = No;
                                                             1 = Yes;
  t   09   36    0        1         0           -            Open additional thread tension
                                                             during quick stroke adjustment
                                                             0 = No;
                                                             1 = Yes;
  t   09   37    0        1         0           -            Open additional thread tension
                                                             during single stitch functions
                                                             0 = No;
                                                             1 = Yes;
  t   09   50    0        999       100         ms           Activation time of thread tension
                                                             magnet in period t1
  t   09   51    5        100       100         %            Duty cycle in period t1
  t   09   52    0,0      600,0     0,0         s            Activation time of thread tension
                                                             magnet in period t2. (if 0, the
                                                             thread tension magnet remains
                                                             continuously switched on)
  t   09   53    5        100       100         %            Duty cycle in period t2
  t   09   54    0        1         0           -            Increase in Umag when the thread
                                                             tension magnet is activated
                                                             0 = No;
                                                             1= Yes
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         19
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
Stroke adjustment
t    10   00   0     1           0            -           Stroke adjustment
                                                          0 = No;
                                                          1= Yes
t    10   01   0     9999        600          rpm         Stroke adjustment speed
t    10   02   1     21          5            Level       Lower threshold
t    10   03   1     21          14           Level       Upper threshold
t    10   04   -     -           -            -           Display of current level and
                                                          corresponding speed,
                                                          e. g. 3: 2800
                                                          3: = current level
                                                          2800 = corresponding speed
t    10   06   0     1           0            -           Speed limit during quick stroke
                                                          adjustment
                                                          0 = Limitation of speed to stroke
                                                          adjustment speed for 500 ms;
                                                          1 = Continuous limitation of
                                                          speed to stroke adjustment
                                                          speed
t    10   07   0,0   2,55        0,0          s           Stopping time of stroke adjust-
                                                          ment speed
t    10   08   0     255         0            Stitches    Number of stitches for automatic
                                                          switch-off of quick stroke adjust-
                                                          ment (when 0, quick stroke ad-
                                                          justment is deactivated)
t    10   09   0     1           0            -           Type of quick stroke adjustment
                                                          potentiometer
                                                          0 = 9880 867105;
                                                          1 = 9880 867119
t    10   10   0     9999        0            rpm         Automatic of activa-
                                                          tion/deactivation of quick stroke
                                                          adjustment
                                                          Quick stroke adjustment activat-
                                                          ed  n < t 10 10
                                                          Quick stroke adjustment deac-
                                                          tivated  n >= t 10 10
                                                          Stored stroke adjustment is
                                                          deactivated
20                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  Function module
  t   11   00    0        16        2           -            Function of function module 1
                                                             (X1.30)
                                                             0 = No function;
                                                             1 = Additional thread tension;
                                                             2 = Stitch length switching;
                                                             3 = Single stitch with stitch
                                                                   length switching;
                                                             4 = Single backward stitch with
                                                                   stitch length switching;
                                                             5 = Raise/lower carrier roll-
                                                                   er/seam middle guide/puller;
                                                             6 = Raise/lower edge stop;
                                                             7 = Raise/lower edge cutter;
                                                             8 = Stitch length switching
                                                                   (Triflex) with DB2000 speed
                                                                   limit and bartack suppres-
                                                                   sion;
                                                             9 = Fullness with DB3000 speed
                                                                   limit;
                                                             10 = Fullness without DB3000
                                                                   speed limit;
                                                             11 = Step cutting;
                                                             12 = Contour guide;
                                                             13 = Stacker;
                                                             14 = Output function;
                                                             15 = Tape cutter;
                                                             16 = Biphasic edge cutter
  t   11   01    0        1         0           -            Invert output of function module 1
                                                             (X1.30)
                                                             0 = No;
                                                             1= Yes
  t   11   02    1        3         1           -            Condition of function module 1
                                                             (X1.30) after thread cutting
                                                             1 = Unchanged;
                                                             2 = Deactivated;
                                                             3 = Activated
  t   11   03    1        3         1           -            Condition of function module 1
                                                             (X1.30) after power on
                                                             1 = Unchanged;
                                                             2 = Deactivated;
                                                             3 = Activated
  t   11   04    0        1         0           -            Function module stored (only if
                                                             t 11 00 = 14)
                                                             0 = Stored;
                                                             1 = Not Stored
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                        21
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    11   05   0     2           0            -           Type of activation delay of func-
                                                          tion module 1 (X1.30) (only if t 11
                                                          00 = 14)
                                                          0 = Time
                                                          1 = Stitches
                                                          2 = Bracket
t    11   06   0     9999        0            s or        Activation delay
                                              stitches
                                              or °
t    11   07   0     2           0            -           Type of switch-off delay of func-
                                                          tion module 1 (X1.30)
                                                          0 = Time
                                                          1 = Stitches
                                                          2 = Bracket
t    11   08   0     9999        0            s or        Switch-off delay
                                              stitches
                                              or °
t    11   09   1     3           1            -           Condition of function module 1
                                                          (X1.30) before thread cutting
                                                          1 = Unchanged;
                                                          2 = Deactivated;
                                                          3 = Activated
t    11   30   0     16          1            -           Function of function module 2
                                                          (X1.20)
                                                          For function see t 11 00
t    11   31   0     1           0            -           Invert output of function module 2
                                                          (X1.20)
                                                          0 = No;
                                                          1= Yes
t    11   32   1     3           1            -           Condition of function module 2
                                                          (X1.20) after thread cutting
                                                          1 = Unchanged;
                                                          2 = Deactivated;
                                                          3 = Activated
t    11   33   1     3           1            -           Condition of function module 2
                                                          (X1.20) after power on
                                                          1 = Unchanged;
                                                          2 = Deactivated;
                                                          3 = Activated
t    11   34   0     1           0            -           Function module stored (only if
                                                          t 11 30 = 14)
                                                          0 = Stored;
                                                          1 = Not Stored
t    11   35   0     2           0            -           Type of activation delay of func-
                                                          tion module 1 (X1.20) (only if t 11
                                                          30 = 14)
                                                          0 = Time
                                                          1 = Stitches
                                                          2 = Bracket
22                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   11   36    0        9999      0           s or         Activation delay
                                                stitches
                                                or °
  t   11   37    0        2         0           -            Type of switch-off delay of func-
                                                             tion module 1 (X1.20)
                                                             0 = Time
                                                             1 = Stitches
                                                             2 = Bracket
  t   11   38    0        9999      0           s or         Switch-off delay
                                                stitches
                                                or °
  t   11   39    1        3         1           -            Condition of function module 2
                                                             (X1.20) before thread cutting
                                                             1 = Unchanged;
                                                             2 = Deactivated;
                                                             3 = Activated
  t   11   60    0        16        0           -            Function of function module 3
                                                             (X1.15)
                                                             For function see t 11 00
  t   11   61    0        1         0           -            Invert output of function module 3
                                                             (X1.15)
                                                             0 = No;
                                                             1= Yes
  t   11   62    1        3         1           -            Condition of function module 3
                                                             (X1.15) after thread cutting
                                                             1 = Unchanged;
                                                             2 = Deactivated;
                                                             3 = Activated
  t   11   63    1        3         1           -            Condition of function module 3
                                                             (X1.15) after power on
                                                             1 = Unchanged;
                                                             2 = Deactivated;
                                                             3 = Activated
  t   11   64    0        1         0           -            Function module stored (only if
                                                             t 11 60 = 14)
                                                             0 = Stored;
                                                             1 = Not Stored
  t   11   65    0        2         0           -            Type of activation delay of func-
                                                             tion module 1 (X1.15) (only if t 11
                                                             60 = 14)
                                                             0 = Time
                                                             1 = Stitches
  t   11   66    0        9999      0           s or         Activation delay
                                                stitches
                                                or °
  t   11   67    0        2         0           -            Type of switch-off delay of func-
                                                             tion module 1 (X1.15)
                                                             0 = Time
                                                             1 = Stitches
                                                             2 = Bracket
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                            23
                                                                             Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    11   68   0     9999        0            s or        Switch-off delay
                                              stitches
                                              or °
t    11   69   1     3           1            -           Condition of function module 3
                                                          (X1.15) before thread cutting
                                                          1 = Unchanged;
                                                          2 = Deactivated;
                                                          3 = Activated
t    11   90   0     999         100          ms          Activation time of output FF3 in
                                                          period t1
t    11   91   5     100         100          %           Duty cycle in period t1
t    11   92   0,0   600,0       0,0          s           Activation time of output FF3 in
                                                          period t2 (if 0, output FF3 remains
                                                          continuously switched on)
t    11   93   5     100         100          %           Duty cycle in period t2
t    11   94   0     1           0            -           Increase in Umag when output FF3
                                                          is activated
                                                          0 = No;
                                                          1= Yes
Reversal
t    12   00   0     1           1            -           Reversal
                                                          0 = No;
                                                          1= Yes
t    12   01   10    350         45           °           Reversal angle
t    12   02   10    255         40           ms          Waiting time until reversal
t    12   03   0     1           0            -           Reverse before seam beginning
                                                          0 = No;
                                                          1= Yes
t    12   04   10    180         10           °           Reversal angle at seam begin-
                                                          ning
Needle cooling/fan
t    13   00   0     1           1            -           Needle cooling mode
                                                          0 = Normal needle cooling;
                                                          1 = Speed-dependent needle
                                                          cooling
t    13   01   0,0   9,999       0,500        s           Switch-off delay of needle cooling
t    13   02   100   9999        500          rpm         Speed for switching on needle
                                                          cooling
t    13   03   0     1           0            -           Needle cooling during sewing
                                                          foot lift
                                                          0 = No;
                                                          1 = Yes
t    13   04   0     1           0            -           Needle cooling during pedal in
                                                          forward Position ½
                                                          0 = No
                                                          1 = Yes
24                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  Carrier roller/puller/seam middle guide
  t   14   00    0        3         3           -            Mode for automatic raising of the
                                                             carrier roller
                                                             0 = Do not raise;
                                                             1 = With sewing foot lift;
                                                             2 = During bartacking;
                                                             3 = During bartacking and when
                                                             sewing foot is lifted
  t   14   01    0        1         0           -            Raise carrier roller when stroke
                                                             adjustment switched on
                                                             0 = No;
                                                             1= Yes
  t   14   02    0        1         0           -            Stitch count delay after sewing
                                                             foot lift (t 14 03)
                                                             0 = No;
                                                             1= Yes
  t   14   03    0        255       0           Stitches     Number of stitches until carrier
                                                             roller is lowered
  t   14   04    0        1         1           -            Encoder Top
                                                             0 = No;
                                                             1 = Yes
  t   14   05    0        1         1           -            Encoder Bottom
                                                             0 = No;
                                                             1 = Yes
  t   14   10    0        2         0           -            Number of active pullers
                                                             (Output X1.26 is configured for
                                                             pressure switch-off)
                                                             0 = No puller;
                                                             1 = Puller from above;
                                                             2 = Puller from above and below
  t   14   11    0        1         0           -            Puller feeding type
                                                             0 = Continual;
                                                             1 = Intermittent
  t   14   12    0        359       30          °            Start feed angle
  t   14   13    0        359       150         °            End feed angle
  t   14   14    0        2         0           -            Puller without pressure (output
                                                             X1.26 is used for this)
                                                             0 = With pressure;
                                                             1 = During quick stroke adjust-
                                                             ment without pressure;
                                                             2 = Continuously without pres-
                                                             sure
  t   14   15    0        1         0           -            Puller is powered off when sew-
                                                             ing stops
                                                             0 = No;
                                                             1= Yes
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                          25
                                                                              Parameter list
E C       P    Min     Max         Preset       Unit        Description
                                   value
t    14   16   0       1           0            -           Puller active even if no carrier
                                                            roller is active
                                                            0 = No;
                                                            1= Yes
t    14   17   10      150         90           mm          Maximum feed length
t    14   20   0,1     65,00       1,00         -           Transmission ratio, top puller
t    14   21   1       200         50           -           Material correction, top puller,
                                                            when feed length is 5 mm
t    14   22   0,1     5,00        3,50         A           Set current, top puller
t    14   23   0,1     3,00        1,00         A           No-damage current, top puller
t    14   24   1       9999        50           mm          Diameter of top carrier roller
t    14   25   0       1           0            -           Direction of rotation
                                                            0 = Right;
                                                            1 = Left
t    14   26   -10,0   10,0        1,0          mm          Feed length during short stitch,
                                                            top puller
t    14   30   0,1     65,00       1,00         -           Transmission ratio of bottom
                                                            puller
t    14   31   1       200         50           -           Material correction, bottom puller,
                                                            when feed length is 5 mm
t    14   32   0,1     5,00        3,50         A           Set current, bottom puller
t    14   33   0,1     3,00        1,00         A           No-damage current, bottom
                                                            puller
t    14   34   1       9999        49           mm          Diameter of bottom carrier roller
t    14   35   0       1           0            -           Direction of rotation
                                                            0 = Right;
                                                            1 = Left
t    14   36   -10,0   10,0        1,0          mm          Feed length during short stitch,
                                                            bottom puller
26                         DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  Edge cutter
  t   15   00    0        7         0           -            Mode for automatic raising of the
                                                             edge cutter
                                                             0 = Do not raise;
                                                             1 = With sewing foot lift;
                                                             2 = After cutting or after stitch
                                                                  counting
                                                                  (t 15 04);
                                                             3 = After cutting or after stitch
                                                                  counting and when sewing
                                                                  foot is lifted;
                                                             4 = During bartacking;
                                                             5 = During bartacking and when
                                                                  sewing foot is lifted;
                                                             6 = After cutting or after stitch
                                                                  counting and during bartack-
                                                                  ing;
                                                             7 = After cutting or after stitch
                                                                  counting, during bartacking
                                                                  and when sewing foot is lift-
                                                                  ed
  t   15   03    0        255       0           Stitches     Number of stitches until edge
                                                             cutter is lowered
  t   15   04    0        255       0           Stitches     Number of stitches until edge
                                                             cutter is lifted (t 15 00 = 2 or 3)
  t   15   05    0        1         0           -            Deactivate edge cutter when
                                                             sewing foot is lifted
                                                             0 = No;
                                                             1= Yes
  t   15   10    0        1         0           -            Electric edge cutter
                                                             0 = No;
                                                             1= Yes
  t   15   11    0        1         0           -            Electric edge cutter when sewing
                                                             stops
                                                             0 = No;
                                                             1= Yes
  t   15   12    0        100       50          %            Minimum PWM for edge cutter
  t   15   13    0        100       95          %            Maximum PWM for edge cutter
  t   15   14    0        9999      1500        rpm          Maximum speed at which maxi-
                                                             mum PWM is to be reached
  t   15   15    0,0      2,55      0,0         s            Delay for switching off the edge
                                                             cutter motor
  t   15   16    0,0      9,999     0,0         ms           Delay between footlifting and
                                                             lifting/lowering the edge cutter
  Light barrier
  t   16   00    50       9999      1000        rpm          Speed for light barrier equalizing
                                                             stitches
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                           27
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    16   01   1     3           3            -           Light barrier mode
                                                          1 = Seam beginning detection;
                                                          2 = Seam end detection;
                                                          3 = Seam beginning & seam end
                                                          detection
t    16   02   0     1           0            -           Mode for seam beginning
                                                          0 = Release via light barrier;
                                                          1 = Start via front pedal and light
                                                          barrier
t    16   03   0     1           0            -           Knitted garment filter
                                                          0 = Off;
                                                          1 = On
t    16   04   0     1           0            -           Light barrier detection
                                                          0 = Bright;
                                                          1 = Dark
t    16   05   0     1           0            -           Light barrier automatic mode
                                                          (only if t 16 01 = 2 or 3)
                                                          0 = Off;
                                                          1 = On
t    16   06   0     9999        0            ms          Time material needs to be de-
                                                          tected before machine start
t    16   07   0     1           0            -           Foot lowering only when material
                                                          is detected. (only with t 16 01 = 1
                                                          or 3 and manual sewing)
                                                          0 = Off;
                                                          1 = On
t    16   08   0     9999        0            ms          Delay between start and foot
                                                          lowering (only with t 16 07 = 1)
t    16   09   0     9999        0            ms          Delay between foot lowering and
                                                          sew start (only with t 16 07 = 1)
Electronic handwheel
t    17   00   0     1           1            -           Electronic handwheel
                                                          0 = No;
                                                          1 = Yes (t 51 32 and t 51 33 = 0)
t    17   01   1     255         15           -           Step width for electronic hand-
                                                          wheel
t    17   02   0     1           0            -           Direction of rotation of electronic
                                                          handwheel
                                                          0 = Right;
                                                          1 = Left
Stacker
t    18   00   0     1           0            -           Stacker
                                                          0 = Off;
                                                          1 = On
t    18   01   0,0   2,55        0,10         s           Activation delay stacker
t    18   02   0,0   2,55        0,10         s           Time when stacker starts clamp-
                                                          ing
t    18   03   0,0   2,55        0,10         s           Duty cycle of the stacker
28                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  Zigzag
  t   19   00    0        359       112         °            Switch position for zigzag
  t   19   01    4        6         6           Stitches     Number of stitches for zigzag
  Thread wiper
  t   20   00    0        1         0           -            Thread wiper
                                                             0 = Off;
                                                             1 = On
  t   20   01    10       255       100         ms           Switch-on period for thread wiper
  Step cutting/contour guide
  t   21   00    0,0      2,55      0,50        s            Delay after switching off edge
                                                             cutter for step cutting
  t   21   01    0,0      2,55      0,50        s            Delay for extension of stepped
                                                             cylinder
  t   21   02    0,0      2,55      0,50        s            Duration of impulse blowing
                                                             during extension of stepped
                                                             cylinder
  t   21   03    0,0      2,55      0,50        s            Delay for switching off blowing
                                                             when sewing stops
  t   21   04    0,0      2,55      0,50        s            Delay for switching on edge
                                                             cutter after switching step cutting
                                                             on/off
  Outfeed roller
  t   22   00    0        3         0           -            Outfeed roller mode
                                                             0 = Off;
                                                             1 = Seam end;
                                                             2 = Seam beginning;
                                                             3 = Seam beginning & seam end;
  t   22   03    0        255       0           Stitches     Number of stitches until outfeed
                                                             roller is lowered at seam begin-
                                                             ning
  t   22   04    0        255       0           Stitches     Number of stitches until outfeed
                                                             roller is lifted at seam beginning
  t   22   05    0,0      99,99     0,50        s            Activation delay of the outfeed
                                                             roller
  t   22   06    0,0      99,99     0,50        s            Duty cycle of outfeed roller at
                                                             seam end
  t   22   07    0,0      20,0      5,0         kHz          Speed of outfeed roller at seam
                                                             end
  Hook lubrication
  t   23   00    0        9999      0           Stitches     Number of stitches until hook
                                                             lubrication is activated
  t   23   01    0,0      99,99     0,0         s            Duration of hook lubrication
  Chain-sucking
  t   24   00    0        100       30          Stitches     Number of stitches until suction
                                                             at the beginning is deactivated
  t   24   01    0,0      10,0      0,8         s            Duration of the final suction
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                           29
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
Stitch loosening device
t    25   00   0     1           0            -           Automatic sewing material thick-
                                                          ness detection
                                                          0 = Off;
                                                          1 = On
t    25   05   0     1           1            -           Speed reduction during stitch
                                                          loosening
                                                          0 = Off;
                                                          1 = On
t    25   06   0     1200        800          rpm         Level to which speed will be
                                                          reduced
t    25   07   1     3           1            -           Condition of stitch loosening
                                                          function after thread cutting
                                                          process
                                                          1 = Unchanged;
                                                          2 = Deactivated;
                                                          3 = Activated
t    25   10   1     255         1            Stitches    Number of stitches after automat-
                                                          ic switching on, when the stitch
                                                          loosening function is forced
t    25   11   0     255         0            Stitches    Number of stitches with stitch
                                                          forced loosening function, after
                                                          which function is deactivated
t    25   12   0     1           0            -           Additional to t 25 11 it is possible
                                                          to programm/select the number
                                                          of stitches with the seamway 2
                                                          and 3 button
                                                          0 = Off;
                                                          1 = On
t    25   15   0     1           0            -           Possibility to interchange fabric
                                                          thickness threshold for switch
                                                          on/off (only with t 25 00 = 1)
Tape Cutter
t    26   00   0     1           0            -           Tape Cutter
                                                          0 = Off;
                                                          1 = On
t    26   01   0,0   2,55        0,80         s           Power-up delay tape cutter
t    26   02   0,0   2,55        0,40         s           Switch-on duration tape cutter
Fabric thickness sensor
t    27   00   0     1           0            -           Fabric thickness sensor
                                                          0 = Off;
                                                          1 = On
t    27   01   0,0   9,9         0,0          mm          Fabric thickness threshold for
                                                          switch on
t    27   02   0,0   9,9         0,0          mm          Fabric thickness threshold for
                                                          switch off
t    27   03   0,0   9,9         0,0          mm          Fabric thickness second thresh-
                                                          old for switch on
30                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   27   04    0,0      9,9       0,0         mm           Fabric thickness second thresh-
                                                             old for switch off
  Chain cutter
  t   28   00    0        2         0           -            Chain cutter mode
                                                             0 = Off;
                                                             1 = On;
                                                             2 = Clamps after cutting
  t   28   01    0        255       0           Stitches     Power down delay after sew start
                                                             (only with t 28 00 = 2)
  t   28   02    50       999       50          ms           Duty cycle of the chain cutter
                                                             (with t 28 00 = 1)
  Stitch length switching
  t   30   00    0        2         2           -            Speed limit if stitch length is long
                                                             0 = Off;
                                                             1 = Speed limit DB2000;
                                                             2 = Speed limit DB3000
  t   30   01    0        2         0           -            Stitch length during bartacking
                                                             0 = Preset stitch length
                                                             (Long/Normal);
                                                             1 = Normal stitch length;
                                                             2 = Long stitch length
  t   30   02    0        2         0           -            Stitch length after thread cutting
                                                             0 = Selected stitch length is
                                                             retained;
                                                             1 = Normal stitch length;
                                                             2 = Long stitch length
  Stitch shortening
  t   31   00    0        255       0           Stitches     Stitch shortening at seam begin-
                                                             ning
  t   31   01    0        255       0           Stitches     Stitch shortening during thread
                                                             cutting
  Operation lock
  t   50   00    0        1         1           -            Operation lock
                                                             0 = Off;
                                                             1 = On
  t   50   01    0        1         0           -            Method of operation of operation
                                                             lock switch
                                                             0 = Closed contact (NC);
                                                             1 = Open contact (NO)
  t   50   02    0        1         1           -            Behavior of the motor
                                                             0 = Emergency cut-off;
                                                             1 = Positioning
  Control, other
  t   51   00    -        -         -           -            Display software version
  t   51   01    -        -         -           -            Display control serial number
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                           31
                                                                           Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    51   02   0     1           0            -           Display analog values (see t 51
                                                          12) during the sewing process
                                                          0 = No;
                                                          1= Yes
t    51   04   -     -           -            -           Display class and subclass
t    51   05   -     -           -            -           Display operating hours
t    51   06   -     -           -            -           Display operating stitches
t    51   07   -     -           -            -           Display piece counters
t    51   08   0     1           -            -           M2M
                                                          0 = Off;
                                                          1 = On
t    51   09   -     -           -            -           Enter/display M2M Customer ID
t    51   10   0     5           -            -           Import data to control
                                                          0 = None; 1 = Parameter settings
                                                          from DA dongle; 2 = Parameter
                                                          settings from backup area;
                                                          3 = Seam paths from DA dongle;
                                                          4 = Master reset;
                                                          5 = Reset seam paths
t    51   11   0     3           -            -           Saving of parameters
                                                          0 = None;
                                                          1 = Parameter settings onto DA
                                                          dongle;
                                                          2 = Parameter settings into back-
                                                          up area;
                                                          3 = Seam paths to the DA dongle
t    51   12   -     -           -            -           Hardware test
                                                          Inputs and outputs in bold are
                                                          only present in the DAC classic.
                                                          1. Analog
                                                          Um: Mains voltage in V
                                                          U24: power supply outputs in V
                                                          Imo: current of 24 V power sup-
                                                          ply
                                                          PAn: analog value of pedal
                                                          Nre: X1.4 analog input
                                                          Ian: X1.1 analog input
                                                          Pst: digitized pedal position
                                                          I2T: I²T of the motor (caution:
                                                          pedal and motor are active!)
                                                          2. Input
                                                          X1.5: Manual Backtack
                                                          X1.6: Nedle up/down
                                                          X1.7: Additional thread tension
                                                          (module 2)
                                                          X1.8: Switch stitch length (mod-
                                                          ule 1)
32                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
                                                             X1.9: Input function module 3
                                                             (module 3)
                                                             X1.10: Limitation DB3000
                                                             X1.11: Machine run blockage
                                                             X1.12: Bobbin thread monitor
                                                             X1.13: Light barrier
                                                             X1.14: Backtack suppres-
                                                             sion/recall
                                                             X2.1: High lift for walking foot
                                                             (not stored)
                                                             X2.2: High lift for walking foot
                                                             (stored)
                                                             X2.3: No Function
                                                             X2.4: No Function
                                                             X2.6: No Function
                                                             X2.7: No Function
                                                             3. Output
                                                             X1.15: Output function module 3
                                                             (module 3)
                                                             X1.17: No Function
                                                             X1.18: Thread clamp
                                                             X1.20: Additional thread tension
                                                             (module 2)
                                                             X1.21: No Function
                                                             X1.22: LED function module 3
                                                             (module 3)
                                                             X1.23: LED bobbin thread moni-
                                                             tor left
                                                             X1.24: LED Backtack suppres-
                                                             sion/recall
                                                             X1.25: LED bobbin thread moni-
                                                             tor right
                                                             X1.26: No Function
                                                             X1.27: No Function
                                                             X1.28: Needle cooling
                                                             X1.29: LED switch stitch length
                                                             (module 1)
                                                             X1.30: Switch stitch length (mod-
                                                             ule 1)
                                                             X1.31: LED additional thread
                                                             tension (module 2)
                                                             X1.32: High lift for walking foot
                                                             X1.34: Backtacking
                                                             X1.35: Sewing foot lifting
                                                             X1.36: Thread tension
                                                             X1.37: Thread trimmer
                                                             4. Flash
  t   51   13    -        -         -           -            Display last 10 error messages
                                                             1 = most recent error
                                                             10 = first error
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                        33
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    51   14   0     2           -            -           Reset maintenance counter
                                                          0 = No;
                                                          1= Yes
t    51   15   0     1           -            -           Automatic reset of M2M counters
                                                          after power-on
                                                          0 = No;
                                                          1= Yes
t    51   16   0     1           -            -           Reset of M2M counters
                                                          0 = No;
                                                          1= Yes
t    51   17   0     9999        -            -           Password for the technician level.
                                                          Password Value 0 disables the
                                                          password query.
t    51   20   0     60          3            -           Set input function for bartack
                                                          input (machine connector Pin 5)
                                                          0 = No function;
                                                          1 = Threader;
                                                          2 = Bartack suppres-
                                                                sion/activation;
                                                          3 = Manual bartack;
                                                          4 = Half stitch;
                                                          5 = Whole stitch;
                                                          6 = Point position;
                                                          7 = Reversal;
                                                          8 = Function module 1 input
                                                                (see t 11 00);
                                                          9 = Function module 2 input
                                                                (see t 11 30);
                                                          10 = Function module 3 input
                                                                (see t 11 60);
                                                          11 = Needle high;
                                                          12 = Ornamental-stitch bartack;
                                                          13 = Needle cooling;
                                                          14 = Thread wiper;
                                                          15 = Normal stitch length during
                                                                bartacking;
                                                          16 = Operation lock when contact
                                                                open (NO);
                                                          17 = Operation lock when contact
                                                                closed (NC);
                                                          18 = Quick stroke adjustment
                                                                (not stored);
                                                          19 = Quick stroke adjustment
                                                                (stored);
                                                          20 = Speed limit DB2000;
                                                          21 = Speed limit DB3000;
                                                          22 = Light barrier;
                                                          23 = Puller feeding type (continu-
                                                                al/intermittent);
                                                          24 = Sewing foot lift with pedal in
34                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C     P      Min      Max       Preset      Unit         Description
                                    value
                                                                  position 0;
                                                             25 = Release for new seam;
                                                             26 = Manual bartack stored;
                                                             27 = Move to zigzag position;
                                                             28 = Zigzag synchronization;
                                                             29 = Stacker on/off;
                                                             30 = Manual stacking
                                                             31 = Function module 1 input on
                                                                  (see t 11 00);
                                                             32 = Function module 1 input off
                                                                  (see t 11 00);
                                                             33 = Function module 2 input on
                                                                  (see t 11 30);
                                                             34 = Function module 2 input off
                                                                  (see t 11 30);
                                                             35 = Function module 3 input on
                                                                  (see t 11 60);
                                                             36 = Function module 3 input off
                                                                  (see t 11 60);
                                                             37 = Service Call (only with
                                                                  M2M);
                                                             38 = Stitch loosening;
                                                             39 = Fullness top;
                                                             40 = Fullness bottom;
                                                             41 = Reverse at seam beginning;
                                                             42 = Sewing foot lift after thread
                                                                  cutter;
                                                             43 = Manual sewing
                                                             44 = Seam end manu-
                                                                  al/automatic sewing;
                                                             45 = Automatic sewing;
                                                             46 = Tape cutter;
                                                             47 = Manual tape cutter;
                                                             48 = Shoulder seam 3827;
                                                             49 = Reset shoulder seam 3827;
                                                             50 = Fullness 3827;
                                                             51 = No seam end start;
                                                             52 = Stitch loosening automatic;
                                                             53 = Stitch loosening on/off;
                                                             54 = Operation lock on/off;
                                                             55 = Fast scissors (PAFF);
                                                             56 = Electronic handwheel for-
                                                                  ward;
                                                             57 = Electronic handwheel back-
                                                                  wards;
                                                             58 = Chain cut/suction (Pfaff);
                                                             59 = Threadmonitor top;
                                                             60 = Threadmonitor bottom
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                        35
                                                                         Parameter list
E C       P    Min   Max      Preset       Unit        Description
                              value
t    51   21   0     60       2            -           Set input function for bartack
                                                       toggle input (machine connector
                                                       Pin 14)
                                                       For function see t 51 20
t    51   22   0     60       4            -           Set input function for needle
                                                       high/low input (machine connect-
                                                       or Pin 6)
                                                       For function see t 51 20
t    51   23   0     60       8            -           Set input function for input FF1
                                                       (machine connector Pin 8)
                                                       For function see t 51 20
t    51   24   0     60       9            -           Set input function for input FF2
                                                       (machine connector Pin 7)
                                                       For function see t 51 20
t    51   25   0     60       13           -           Set input function for input FF3
                                                       (machine connector Pin 9)
                                                       For function see t 51 20
t    51   26   0     60       21           -           Set input function for input (ma-
                                                       chine connector Pin 10)
                                                       For function see t 51 20
t    51   27   0     60       0            -           Set input function for light barrier
                                                       input (machine connector Pin 13)
                                                       For function see t 51 20
t    51   28   0     60       18           -           Set input function IN_EXT1
                                                       (additional input interface Pin 1)
                                                       For function see t 51 20
t    51   29   0     60       19           -           Set input function IN_EXT2
                                                       (additional input interface Pin 2)
                                                       For function see t 51 20
t    51   30   0     60       0            -           Set input function IN_EXT3
                                                       (additional input interface Pin 3)
                                                       For function see t 51 20
t    51   31   0     60       6            -           Set input function IN_EXT4
                                                       (additional input interface Pin 4)
                                                       For function see t 51 20
t    51   32   0     60       0            -           Set input function IN_EXT5
                                                       (additional input interface Pin 6)
                                                       For function see t 51 20
t    51   33   0     60       0            -           Set input function IN_EXT6
                                                       (additional input interface Pin 7)
                                                       For function see t 51 20
36                    DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C      P     Min      Max       Preset      Unit         Description
                                    value
  t   51   50    0        42        1           -            Set output function for output
                                                             (machine connector Pin 18)
                                                             0 = No function;
                                                             1 = Thread clamp;
                                                             2 = Locking;
                                                             3 = Sewing foot lift;
                                                             4 = Thread tension;
                                                             5 = Auxiliary thread tension;
                                                             6 = Second stitch length;
                                                             7 = Carrier roller;
                                                             8 = Edge stop;
                                                             9 = Edge cutter;
                                                             10 = Fullness with DB3000;
                                                             11 = Fullness without DB3000;
                                                             12 = Step cutting;
                                                             13 = Contour guide;
                                                             14 = Stacker;
                                                             15 = Thread cutter;
                                                             16 = Quick stroke adjustment;
                                                             17 = Needle cooling;
                                                             18 = Stitch shortening;
                                                             19 = Pulse step cutting;
                                                             20 = Open step cutting;
                                                             21 = Thread clamp NSB;
                                                             22 = Thread puller NSB;
                                                             23 = Carrier roller pressure;
                                                             24 = Sewing foot pressure;
                                                             25 = Ready for sewing start;
                                                             26 = Pos. 1;
                                                             27 = Pos. 2;
                                                             28 = Motor operation;
                                                             29 = In the seam;
                                                             30 = Outfeed roller;
                                                             31 = Transport unit;
                                                             32 = Hook lubrication;
                                                             33 = Thread wiper;
                                                             34 = Suction NSB;
                                                             35 = Tape cutter;
                                                             36 = Edge cutter off;
                                                             37 = Stitch loosening;
                                                             38 = Fullness top;
                                                             39 = Fullness bottom;
                                                             40 = Chain cutter;
                                                             41 = Cleaning of SSD sensor;
                                                             42 = Pos. 3
  t   51   51    0        42        27          -            Set output function for output
                                                             (machine connector Pin 21),
                                                             For function see t 51 50
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         37
                                                                            Parameter list
E C       P    Min   Max         Preset       Unit        Description
                                 value
t    51   52   0     42          0            -           Set output function for output
                                                          (machine connector Pin 22),
                                                          For function see t 51 50
t    51   53   0     42          26           -           Set output function for output
                                                          (machine connector Pin 26),
                                                          For function see t 51 50
t    51   54   0     42          18           -           Set output function for output
                                                          (machine connector Pin 27),
                                                          For function see t 51 50
t    51   55   0     42          17           -           Set output function for output
                                                          (machine connector Pin 28),
                                                          For function see t 51 50
t    51   56   0     42          16           -           Set output function for output
                                                          (machine connector Pin 32),
                                                          For function see t 51 50
t    51   70   0     9999        0            x t5171     Reset value of maintenance
                                                          counter II (counter is deactivated
                                                          at 0)
t    51   71   1     255         1            x 1000St    Factor of maintenance counter II
t    51   72   1     255         1            x t5171     Error message repeated
t    51   73   0     99          1            -           Number of error message re-
                                                          peats
OP1000
t    52   00   0     9           4            -           Display contrast of OP1000
t    52   01   0     1           1            -           Button tones
                                                          0 = Off;
                                                          1 = On
t    52   20   0     60          1            -           Set input function for F button of
                                                          OP1000
                                                          0 = No function;
                                                          1 = Threader;
                                                          2 = Bartack suppres-
                                                               sion/activation;
                                                          3 = Manual bartack;
                                                          4 = Half stitch;
                                                          5 = Whole stitch;
                                                          6 = Point position;
                                                          7 = Reversal;
                                                          8 = Function module 1 input
                                                               (see t 11 00);
                                                          9 = Function module 2 input
                                                               (see t 11 30);
                                                          10 = Function module 3 input
                                                               (see t 11 60);
                                                          11 = Needle high;
                                                          12 = Ornamental-stitch bartack;
                                                          13 = Needle cooling;
                                                          14 = Thread wiper;
38                       DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C     P      Min      Max       Preset      Unit         Description
                                    value
                                                             15 = Normal stitch length during
                                                                  bartacking;
                                                             16 = Operation lock when contact
                                                                  open (NO);
                                                             17 = Operation lock when contact
                                                                  closed (NC);
                                                             18 = Quick stroke adjustment
                                                                  (not stored);
                                                             19 = Quick stroke adjustment
                                                                  (stored);
                                                             20 = Speed limit DB2000;
                                                             21 = Speed limit DB3000;
                                                             22 = Light barrier;
                                                             23 = Puller feeding type (continu-
                                                                  al/intermittent);
                                                             24 = Sewing foot lift with pedal in
                                                                  position 0;
                                                             25 = Release for new seam;
                                                             26 = Manual bartack stored;
                                                             27 = Move to zigzag position;
                                                             28 = Zigzag synchronization;
                                                             29 = Stacker on/off;
                                                             30 = Manual stacking
                                                             31 = Function module 1 input on
                                                                  (see t 11 00);
                                                             32 = Function module 1 input off
                                                                  (see t 11 00);
                                                             33 = Function module 2 input on
                                                                  (see t 11 30);
                                                             34 = Function module 2 input off
                                                                  (see t 11 30);
                                                             35 = Function module 3 input on
                                                                  (see t 11 60);
                                                             36 = Function module 3 input off
                                                                  (see t 11 60);
                                                             37 = Service Call (only with
                                                                  M2M);
                                                             38 = Stitch loosening;
                                                             39 = Fullness top;
                                                             40 = Fullness bottom;
                                                             41 = Reverse at seam beginning;
                                                             42 = Sewing foot lift after thread
                                                                  cutter;
                                                             43 = Manual sewing
                                                             44 = Seam end manu-
                                                                  al/automatic sewing;
                                                             45 = Automatic sewing;
                                                             46 = Tape cutter on/off;
                                                             47 = Manual cutting tape cutter;
                                                             48 = Shoulder seam 3827;
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         39
                                                                            Parameter list
E C        P    Min   Max         Preset       Unit        Description
                                  value
                                                           49 = Reset shoulder seam 3827;
                                                           50 = Fullness 3827;
                                                           51 = No seam end start;
                                                           52 = Stitch loosening automatic;
                                                           53 = Stitch loosening on/off;
                                                           54 = Operation lock on/off;
                                                           55 = Fast scissors (PAFF);
                                                           56 = Electronic handwheel for-
                                                                ward;
                                                           57 = Electronic handwheel back-
                                                                wards;
                                                           58 = Chain cut/suction (Pfaff);
                                                           59 = Threadmonitor top;
                                                           60 = Threadmonitor bottom
t    52    40   0     1           0            -           Button lock for start bartack
                                                           buttons
                                                           0 = Off;
                                                           1 = On
t    52    41   0     1           0            -           Button lock for end bartack but-
                                                           tons
                                                           0 = Off;
                                                           1 = On
t    52    42   0     1           0            -           Button lock for thread buttons
                                                           0 = Off;
                                                           1 = On
t    52    43   0     1           0            -           Button lock for button group
                                                           seam program
                                                           0 = Off;
                                                           1 = On
t    52    44   0     1           0            -           Button lock for button group
                                                           programming
                                                           0 = Off;
                                                           1 = On
t    52    45   0     1           0            -           Button lock for thread clamp
                                                           button
                                                           0 = Off;
                                                           1 = On
1.3       Developer level
E C        P    Min   Max         Preset       Unit        Description
                                  value
Bartack
d 00       01   0     359         15           °           Mechanical switch-over angle for
                                                           bartack
Thread cutter (FA)
d 02       00   10    359         100          -           Angle at which thread cutting
                                                           speed is to be reached before
                                                           magnets are switched on
40                        DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C     P      Min      Max       Preset      Unit         Description
                                    value
  d 02    01     0        1         0           -            Chainstitch mode
                                                             0 = No;
                                                             1= Yes
  Seam paths
  d 07    00     150      9999      1500        rpm          Speed limit for seam paths
  d 07    01     1        20        6           Stitches     Number of stitches for seam path
                                                             speed limit
  Motor
  d 08    00     1        9999      1000        rpm          Maximum motor speed
  d 08    01     1        100       20          rpm/ms       Maximum acceleration or decel-
                                                             eration
  d 08    02     0        50        20          Kgcm²        Machine inertia
  d 08    04     0        255       0           Inc          Extension of deceleration ramp
  d 08    05     0        1         0           -            Acceleration and deceleration
                                                             ramp halved when I²t increases
                                                             to over 70 %
                                                             0 = No;
                                                             1= Yes
  d 08    10     0,1      100,0     3,1         Ohm          Stator resistance
  d 08    11     1        200       11          mH           Stator inductance
  d 08    12     0,1      200,0     67,5        V/1000       EMF
                                                rpm
  d 08    13     0,1      15,00     11,00       A            Maximum stator current
  d 08    14     1        10        3           -            Number of pole pairs
  d 08    20     0        255       30          -            Kpn factor of PID speed controller
  d 08    21     0        255       33          -            Kin factor of PID speed controller
  d 08    22     0        255       0           -            Kdn factor of PID speed controller
  d 08    23     0        255       12          -            Feed-forward of speed control in
                                                             deceleration process
  d 08    30     0        255       12          -            Kps factor of PID distance control-
                                                             ler
  d 08    31     0        255       3           -            KIs factor of PID distance control-
                                                             ler
  d 08    32     0        255       0           -            Kds factor of PID distance control-
                                                             ler
  d 08    40     0        255       52          -            Kpx factor of PID position control-
                                                             ler
  d 08    41     0        255       52          -            Kdx factor of PID position control-
                                                             ler
  d 08    42     0        255       16          Inc          Increments for activation of PID
                                                             position controller
  d 08    43     0        1000      0           2.857°       Angle for positioning
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         41
                                                                            Parameter list
E C    P     Min   Max         Preset       Unit        Description
                               value
d 08   44    0     1000        16           Inc         Increments for duration of activa-
                                                        tion of positioning speed
d 08   45    10    100         50           rpm         Increase in speed for position
                                                        controller during thread cutting
d 08   46    0     200         0            Inc         Increase increments for the
                                                        position controller during thread
                                                        cutting
d 08   51    0     1           0            -           Continuous operation
                                                        0 = No;
                                                        1= Yes
d 08   52    0,0   99,99       5,00         s           Motor on duration
d 08   53    0,0   99,99       5,00         s           Motor off duration
d 08   54    1     9999        900          s           Duration of continuous operation
d 08   55    0     2000        180          rpm         Speed for reference run
Thread tension
d 09   01    5     100         100          %           Duty cycle for threader
Top puller
d 14   00    0,1   20,00       6,00         kHz         Maximum frequency
d 14   01    1     500         200          rpm/ms      Acceleration ramp
d 14   02    1     500         200          rpm/ms      Deceleration ramp
d 14   03    1     9000        2000         Hz          Start frequency
d 14   04    1     9000        2000         Hz          Stop frequency
d 14   05    1     1000        500          Lines       Encoder lines
d 14   06    1     9000        2000         Steps       Microsteps per turn
d 14   10    0,1   9,000       1,100        Ohm         Stator resistance
d 14   11    0,1   9,000       2,200        mH          Stator inductance
d 14   12    0     1000        0            -           EMF factor
d 14   13    0,1   10,00       3,50         A           Maximum stator current (regulat-
                                                        ed)
d 14   14    1     100         50           -           Number of pole pairs
d 14   15    0,1   10,00       2,00         A           Maximum no-damage current
                                                        (regulated)
d 14   16    0,1   10,00       3,50         A           Maximum stator current (con-
                                                        trolled)
d 14   17    0,1   10,00       2,00         A           Maximum no-damage current
                                                        (controlled)
d 14   20    0     9999        0            -           Kpn factor of PID speed controller
d 14   21    0     9999        0            -           Kin factor of PID speed controller
d 14   22    0     9999        0            -           Kdn factor of PID speed controller
42                     DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  E C     P      Min      Max       Preset      Unit         Description
                                    value
  d 14    30     0        9999      1500        -            Kps factor of PID distance control-
                                                             ler
  d 14    31     0        9999      50          -            KIs factor of PID distance control-
                                                             ler
  d 14    32     0        9999      0           -            Kds factor of PID distance control-
                                                             ler
  d 14    40     0        9999      1500        -            Kpx factor of PID position control-
                                                             ler
  d 14    41     0        9999      0           -            KIx factor of PID position control-
                                                             ler
  d 14    42     0        9999      100         -            Kdx factor of PID position control-
                                                             ler
  Bottom puller
  d 14    50     0,1      20,00     6,00        kHz          Maximum frequency
  d 14    51     1        500       200         rpm/ms       Acceleration ramp
  d 14    52     1        500       200         rpm/ms       Deceleration ramp
  d 14    53     1        9000      2000        Hz           Start frequency
  d 14    54     1        9000      2000        Hz           Stop frequency
  d 14    55     1        1000      500         Lines        Encoder lines
  d 14    56     1        9000      2000        Steps        Microsteps per turn
  d 14    60     0,1      9,000     1,100       Ohm          Stator resistance
  d 14    61     0,1      9,000     2,200       mH           Stator inductance
  d 14    62     0        1000      0           -            EMF factor
  d 14    63     0,1      10,00     3,50        A            Maximum stator current
  d 14    64     1        100       50          -            Number of pole pairs
  d 14    65     0,1      10,00     2,00        A            Maximum no-damage current
  d 14    66     0,1      10,00     3,50        A            Maximum stator current (con-
                                                             trolled)
  d 14    67     0,1      10,00     2,00        A            Maximum no-damage current
                                                             (controlled)
  d 14    70     0        9999      0           -            Kpn factor of PID speed controller
  d 14    71     0        9999      0           -            Kin factor of PID speed controller
  d 14    72     0        9999      0           -            Kdn factor of PID speed controller
  d 14    80     0        9999      1500        -            Kps factor of PID distance control-
                                                             ler
  d 14    81     0        9999      50          -            KIs factor of PID distance control-
                                                             ler
  d 14    82     0        9999      0           -            Kds factor of PID distance control-
                                                             ler
  d 14    90     0        9999      1500        -            Kpx factor of PID position control-
                                                             ler
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                         43
                                                                         Parameter list
E C    P    Min   Max         Preset       Unit        Description
                              value
d 14   91   0     9999        0            -           KIx factor of PID position control-
                                                       ler
d 14   92   0     9999        100          -           Kdx factor of PID position control-
                                                       ler
Control, other
d 51   00   1     255         40           ms          Time duration for raising Umag to
                                                       33 V
d 51   01   1     255         5            ms          Duration for DeEnergizer process
d 51   02   0,1   16,00       16,00        kHz         Set PWM frequency
d 51   03   -     -           -            -           Display machine serial number
d 51   04   -     -           -            -           Display production date
d 51   10   0     9999        8000         x d5111     Reset value of maintenance
                                                       counter (counter is deactivated at
                                                       0)
d 51   11   1     255         1            x           Factor of maintenance counter
                                           10000St
d 51   12   1     255         200          x d5111     Error message repeated
d 51   13   1     99          1            -           Number of error message re-
                                                       peats
44                    DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
 Parametersätze für die Klasse 969
 Parametersatz
                                               2
 Für Un-
                                               969-100080-2
 terklassen
                     969-190180
                                  969-190382
 E    K       P     Preset        Preset       Preset
 t    08      00    1000          1000         1200
 t    08      03    10            10           15
 t    08      04    10            10           5
 t    08      07    0,7           0,7          1,5
 t    08      08    30            30           20
 t    08      12    115           115          128
 t    08      19    359           442          259
 d    08      00    1000          1250         1200
 d    08      01    20            20           25
 d    08      10    3,1           3,1          2,0
 d    08      11    11            11           5
 d    08      12    67,5          67,5         39,8
 d    08      14    3             3            2
 d    08      20    30            30           24
 d    08      21    33            33           24
 d    08      23    12            12           24
 d    08      30    12            12           0
 d    08      31    3             3            0
 d    08      40    52            52           34
 d    08      41    52            52           34
 d    08      42    16            16           18
 d    08      44    16            16           0
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022   45
                                                       Parameter list
46   DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
 2    Error, warning and information messages
  Code Type            Possible cause                   Remedial action
   1000 Error          Sewing motor encoder plug        - Connect encoder cable to the control,
                       (Sub-D, 9-pin) not connected     use correct connection
   1001 Error          Sewing motor error:              - Check connection and plug in, if nec-
                       Sewing motor plug (AMP) not      essary
                       connected                        - Test sewing motor phases (R= 2.8 ,
                                                        high impedance to PE)
                                                        - Replace the encoder
                                                        - Replace the sewing motor
                                                        - Replace the control
   1002 Error          Sewing motor insulation error    - Check motor phase and PE for low-
                                                        impedance connection
                                                        - Replace the encoder
                                                        - Replace the sewing motor
   1004 Error          Sewing motor error:              - Replace the encoder
                       Incorrect sewing motor direction - Check plug assignment and change, if
                       of rotation                      necessary
                                                        - Check wiring in machine distributor and
                                                        change it, if necessary
                                                        - Test motor phases and check for
                                                        correct value
   1005 Error          Motor blocked                    - Eliminate stiff movement in the ma-
                                                        chine
                                                        - Replace the encoder
                                                        - Replace the motor
   1006 Error          Maximum speed exceeded           - Replace the encoder
                                                        - Perform reset
                                                        - Check class (t 51 04)
   1007 Error          Error in the reference run       - Replace the encoder
                                                        - Eliminate stiff movement in the ma-
                                                        chine
   1008 Error          Encoder error                    - Replace the encoder
   1010 Error          External synchronizer plug       Connect cable of external synchronizer
                       (Sub-D, 9-pin) not connected     to control, use correct connection (Sync)
                                                        - Only required for machines with trans-
                                                        mission!
   1011 Error          Encoder Z pulse missing          - Switch off the control. Turn handwheel
                                                        and switch on the control again
                                                        - If error is not corrected, check encoder
   1012 Error          Synchronizer fault               - Replace the synchronizer
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                           47
                                                                              Parameter list
 Code Type          Possible cause                    Remedial action
 1052 Error         Sewing motor overcurrent,         - Check selection of class
                    internal current increase >25 A   - Replace the control
                                                      - Replace the sewing motor
                                                      - Replace the encoder
 1053 Error         Sewing motor overvoltage          - Check selection of class
                                                      - Replace the control
 1054 Error         Internal short circuit            - Replace the control
 1055 Error         Sewing motor overload             - Eliminate stiff movement in the ma-
                                                      chine
                                                      - Replace the encoder
                                                      - Replace the sewing motor
 1203 Information   Position not reached (during      - Check and, if necessary, change con-
                    thread cutting, reversal, etc.)   troller settings.
                                                      Mechanical changes to the machine.
                                                      (e. g. thread cutting setting, belt tension,
                                                      etc.)
                                                      - Check position (thread lever at top
                                                      dead center)
 2020 Information   DACextension box not respond- - Check connection cables
                    ing                           - Check LEDs of DACextension box
                                                  - Software update
 2021 Information   Sewing motor encoder plug       - Connect encoder cable to DACexten-
                    (Sub-D, 9-pin) not connected to sion box using the correct connection
                    DACextension box
 2101 Information   DA stepper card 1 reference run - Check reference sensor
                    timeout
 2103 Information   DA stepper card 1 step losses     - Check for stiff movement
 2106 Information   DA stepper card 1 speed over-     -
                    run
 2120 Information   DA stepper card 1 not respond- - Check connection cables
                    ing                            - Check LEDs of DACextension box
                                                   - Software update
 2121 Information   DA stepper card 1 encoder plug - Connect encoder cable to the control,
                    (Sub-D, 9-pin) not connected   use correct connection
 2122 Information   DA stepper card 1 flywheel        - Check connection cables
                    position not found                - Check stepper motor 1 for stiff move-
                                                      ment
 2155 Information   DA stepper card 1 overload        - Check for stiff movement
 2201 Information   DA stepper card 2 reference run - Check reference sensor
                    timeout
 2203 Information   DA stepper card 2 step losses     - Check for stiff movement
48                      DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  Code Type            Possible cause                    Remedial action
   2206 Information    DA stepper card 2 speed over-     -
                       run
   2220 Information    DA stepper card 2 not respond- - Check connection cables
                       ing                            - Check LEDs of DACextension box
                                                      - Software update
   2221 Information    DA stepper card 2 encoder plug - Connect encoder cable to the control,
                       (Sub-D, 9-pin) not connected   use correct connection
   2222 Information    DA stepper card 2 flywheel        - Check connection cables
                       position not found                - Check stepper motor 2 for stiff move-
                                                         ment
   2255 Error          DA stepper card 2 overload        - Check for stiff movement
   3100 Error          AC-RDY timeout, intermediate - Check the mains voltage
                       circuit voltage did not reach the - If the mains voltage is OK, replace the
                       defined threshold in the speci- control
                       fied time
   3101 Error          High voltage fault, mains volt-   - Check mains voltage, if nominal volt-
                       age, longer duration >290 V       age is continuously exceeded, stabilize it
                                                         or use a generator
   3102 Error          Low voltage failure              - Check the mains voltage
                       (2nd threshold) (mains voltage < - Stabilize mains voltage
                       150 V AC)                        - Use generator
   3103 Information    Low voltage warning              - Check the mains voltage
                       (1st threshold) (mains voltage < - Stabilize mains voltage
                       180 V AC)                        - Use generator
   3104 Warning        Pedal is not in position 0        When switching the control on, take your
                                                         foot off the pedal
   3105 Error          U24 V short circuit               - Disconnect 37-pin plug; if error per-
                                                         sists, replace control
                                                         - Test inputs/outputs for 24 V short
                                                         circuit
   3106 Error          U24 V (I²T) overload              - One or more magnets defective
   3107 Error          Pedal not connected               - Connect analog pedal
   3108 Information    Speed limited due to insufficient - Check the mains voltage
                       mains voltage
   3109 Warning        Operation lock                    - Check tilt sensor on machine
   3150 Information    Maintenance necessary             - For information on lubricating the
                                                         machine, see the service instructions for
                                                         the machine
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                              49
                                                                             Parameter list
 Code Type          Possible cause                   Remedial action
 3151 Warning       Maintenance necessary (opera- - Service is urgently required, see ser-
                    tion cannot continue unless       vice instructions for the machine
                    parameter
                    t 51 14 is reset, see the operat-
                    ing instructions of the machine)
 3152 Information   Maintenance counter II expired   -
 3153 Warning       Maintenance counter II expired   -
                    (operation cannot continue
                    unless counter is reset with
                    parameter t 51 14 = 2)
 3155 Information   No release for sewing process    - Parameter t 51 20 – t 51 33 = 25
                                                     - Input signal for sewing process release
                                                     required
 3160 Information   Stitch loosening device          - Stitch loosening cannot be performed
 3170 Information   Quality issues of the fabric     - Check the positioning of the fabric
                    thickness signal                 thickness sensor
 3210 Information   Topthread torn                   -
 3211 Information   Bottomthread torn                -
 3215 Information   Bobbin stitch counter (info value - Change bobbin, set counter value -
                    0 reached)                        press counter reset button
 3216 Information   Remaining thread monitor left    - Change left bobbin
 3217 Information   Remaining thread monitor right   - Change right bobbin
 3218 Information   Remaining thread monitor left    - Change left and right bobbin
                    and right
 3219 Information   Mode for Bobbing-Thread-         - Thread cutting
                    Winding is active
 3223 Information   Skip stitch detected             -
 3224 Information   Bobbin failed to rotate          -
 3325 Information   SSD sensor is dirty              -
 6353 Error         Internal EEprom communication - Switch off the control, wait until the
                    error                         LEDs are off and then switch on again
 6354 Error         External EEprom communica-       - Switch off the control, wait until the
                    tion error                       LEDs are off, check connection for
                                                     machine ID, switch on control again
 6357 Error         Short circuit EEprom             - Switch off the control, wait until the
                                                     LEDs are off, check connection for
                                                     machine ID, switch on control again
                                                     - replace control
                                                     - replace Masch-ID
50                      DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
Parameter list
  Code Type            Possible cause                      Remedial action
   6360 Information    No valid data on external        - Software update
                       EEprom (internal data structures
                       are not compatible with the
                       external data storage device)
   6361 Information    No external EEprom connected - Connect machine ID
   6362 Information    No valid data on internal           - Check machine ID connection
                       EEprom (internal data structures    - Switch off the control, wait until the
                       are not compatible with the         LEDs are off and then switch on again
                       external data storage device)       - Software update
   6363 Information    No valid data on internal and       - Check machine ID connection
                       external EEprom                     - Switch off the control, wait until the
                       (Software version is not compat-    LEDs are off and then switch on again
                       ible with the internal data stor-   - Software update
                       age device, emergency operat-
                       ing features only)
   6364 Information    No valid data on internal           - Check machine ID connection
                       EEprom and external EEprom          - Switch off the control, wait until the
                       not connected                       LEDs are off and then switch on again
                       (the internal data structures are   - Software update
                       not compatible with the external
                       data storage device, emergency
                       operating features only)
   6365 Information    Internal EEprom defective           - Replace the control
   6366 Information    Internal EEprom defective and       - Replace the control
                       external data not valid
                       (emergency operating features
                       only)
   7202 Information    DACextension box boot error         - Check connection cables
                                                           - Software update
                                                           - Replace DACextension box
   7203 Information    Checksum error during update        - Check connection cables
                                                           - Software update
                                                           - Replace DACextension box
   7212 Information    DA stepper card 1 boot error        - Check connection cables
                                                           - Software update
                                                           - Replace DACextension box
   7213 Information    Checksum error occurred while - Check connection cables
                       updating DA stepper card 2    - Software update
                                                     - Replace DACextension box
   7222 Information    DA stepper card 2 boot error        - Check connection cables
                                                           - Software update
                                                           - Replace DACextension box
 DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022                            51
                                                                                 Parameter list
 Code Type          Possible cause                    Remedial action
 7223 Information   Checksum error occurred while - Check connection cables
                    updating DA stepper card 2    - Software update
                                                  - Replace DACextension box
 7231 Information   Bobbin control is not connected - Check connection cables
                                                    - Software update
 7232 Information   Bootloader failure bobbin control - Check connection cables
                                                      - Software update
 7233 Information   Checksum error occurred while - Check connection cables
                    updating bobbin control card  - Software update
 7241 Information   Fabric thickness sensor is not    - Check connection cables
                    connected                         - Software update
 7801 Information   Software version error            - Software update
                    (DAC classic only; only the       - Replace the control
                    functions of the DAC basic will
                    remain available)
 7802 Information   Software update error             - Another software update
                    (DAC classic only; only the       - Replace the control
                    functions of the DAC basic will
                    remain available)
 7803 Information   Communication error               - Restart of the control
                    (DAC classic only; only the       - Software update
                    functions of the DAC basic will   - Replace the control
                    remain available)
 8401 Error         Watchdog                          - Software update
                                                      - Machine ID reset
                                                      - Replace the control
 8402 Error         Internal error                    - Software update
                                                      - Machine ID reset
     –
                                                      - Replace the control
 8405
 8406 Error         Checksum error                    - Software update
                                                      - Replace the control
 8501 Error         Software protection               - the DA tool must always be used for
                                                      software updates
52                      DAC basic/classic Parameter list class 969 - version B03.8 - 06-2022
                                    Subject to design changes – Printed in Germany - © Dürkopp Adler GmbH – Parameter List 0791 969901 - Version B03.8 - 06-2022
DÜRKOPP ADLER GmbH
Potsdamer Str. 190
33719 Bielefeld
Germany
Phone: +49 (0) 521 925 00
Email: service@duerkopp-adler.com
www.duerkopp-adler.com