0% found this document useful (0 votes)
4 views3 pages

Kemet Electronics Corporation FSCM 31433 Test Report For Solderability Physical Analysis

The test report for Kemet Electronics Corporation's part number 1A151 indicates that the lot has been accepted after thorough solderability and physical analysis. All pre-test examinations and destructive physical analysis requirements were met with no defects reported. The report was approved by Edwin Barrera and inspected by Ludivina Cortina on November 29, 2023.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views3 pages

Kemet Electronics Corporation FSCM 31433 Test Report For Solderability Physical Analysis

The test report for Kemet Electronics Corporation's part number 1A151 indicates that the lot has been accepted after thorough solderability and physical analysis. All pre-test examinations and destructive physical analysis requirements were met with no defects reported. The report was approved by Edwin Barrera and inspected by Ludivina Cortina on November 29, 2023.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Page 1of 2

KEMET ELECTRONICS CORPORATION


FSCM 31433
TEST REPORT FOR SOLDERABILITY PHYSICAL ANALYSIS

TEST REPORTS FOR SOLDERABILITY,ELECTRICAL SURVIVABILITY

Customer: Northrop Part Number: 1A151


Purchase Order: Date/Lot Code: 2334A1
Work Order or Factory Order: Line:
Sample Size: Number of Defectives Allowed:
Accept /Reject Lot: ACCEPT Approved: EDWIN BARRERA
Inspector: LUDIVINA CORTINA Title: SUPERVISOR QC
Date: 11/29/2023

7.1 PRE-TEST EXAMINATION:

Requirement ACCEPT REJECT


a ) Verification of part number
and Date/Lot code number. 14 0

b) Workmanship examination 14 0

c) Dimensional verification 14 0

7.2 SOLDERABILITY, ELECTRICAL SURVIVABILITY (5 SAMPLES) (GROUP A)

SAMPLE METALIZATION PASS /


INITIAL FINAL
INSPECTION
FAIL
DELTA
Parameter CAP DF DIP 1 DIP 2 DIP 3 CAP DF
CAP
I.R

Units PF % -- -- -- PF % Mohms

1,010.0000 2.00
Limits 990.0000
0.15 -- -- -- -- 0.15
-1.00
1.00E+05

993.9020 0.036 OK OK OK 993.8910 0.136 -0.0011 2.28E+06 PASS


1

1002.4900 0.102 OK OK OK 1002.5300 0.033 0.0040 8.00E+06 PASS


2

1007.1400 0.055 OK OK OK 1006.9600 0.045 -0.0179 8.57E+06 PASS


3

1007.2700 0.048 OK OK OK 1007.2100 0.048 -0.0060 9.57E+06 PASS


4

1006.9600 0.048 OK OK OK 1006.8200 0.079 -0.0139 6.16E+06 PASS


5

1001.0300 0.045 OK OK OK 1001.0400 0.087 0.0010 5.42E+06 PASS


6

994.2800 0.033 OK OK OK 994.0580 0.117 -0.0223 7.64E+06 PASS


994.2800 0.033 OK OK OK 994.0580 0.117 -0.0223 7.64E+06 PASS
7
F-QCM0245 Rev.0

Page 2 of 2
7.3 DESTRUCTIVE PHYSICAL ANALYSIS 14 SAMPLES

Requirement ACCEPT REJECT Serial No


(if Reject )
a) Delamination shall not exceed 10% of active electrode length or
010 inch,whichever is greater, shall not reduce
the dielectric thickness by more than 50% 14 0

b) No more than 3 delaminations of any


length in any sample. 14 0

c) No delamination from an electrode to opposite termination. 14 0

d) Uniform dielectric layer thickness,


variations no more than +50% of average thickness. 14 0

e) No cracks between electrodes or from


an electrode to outer surface. 14 0

f) Voids do not reduce remaining dielectric material to less than


50 % of electrode spacing or more than 10% longer than
active electrode length,or .010 inch, whichever is greater. 14 0

g) End and side margins .003" minimum. 14 0

h) Inactive electrodes terminated, discontinuities within active


electrodes shall not exceed 20% of active electrode length. 14 0

i) All 3 layers of metallization visible and bonded to element. 14 0

j) Discontinuities less than .001 inch, no more than 1 per


corner total discontinuities do not exceed .005" 14 0

k) Intermediate copper or nickel thickness 00005 to .0008 inch.


Minor variations do not exceed .0015 inch thickness
or more than 25% total length. 14 0

l) Cover plate at least equal to dielectric thickness, or


.001 inch per 50 volts of rated voltage, whichever is less. 14 0

n) Any void in the primary end termination metallization shall


not measure greater than .020” inches. 14 0

o) Any void in then primary end termination metallization shall


not exceed 35% of the electrode stack thickness. 14 0

p) Any series of (2) two or more voids in the primary end


termination metallization,where the metallization is obviously
well bonded to the chip element, total length shall not exceed
50% of the chip element thickness 14 0

q) All samples have the same electrode count 14 0

Comments:
F-QCM0245 Rev.0

You might also like