0% found this document useful (0 votes)
41 views1 page

Louie 3

The document contains general architectural notes and details for a proposed two-storey residence, including specifications for various building elements such as doors, windows, and finishes. It emphasizes the importance of verifying field conditions, coordinating work, and adhering to contract documents. Additionally, it outlines requirements for fire ratings and the treatment of penetrations in fire-rated partitions.

Uploaded by

tikboyalnor8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views1 page

Louie 3

The document contains general architectural notes and details for a proposed two-storey residence, including specifications for various building elements such as doors, windows, and finishes. It emphasizes the importance of verifying field conditions, coordinating work, and adhering to contract documents. Additionally, it outlines requirements for fire ratings and the treatment of penetrations in fire-rated partitions.

Uploaded by

tikboyalnor8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1700

C' GENERAL ARCHITECTURAL NOTES


600 580 600 581 400
C D A. REFER SCALE TO ALL DRAWINGS
2586 600 580 600 581 400
3820
B. GENERAL CONTRACTOR TO VERIFY FIELD CONDITIONS
BLOW-UP TOILET & BATH PLAN PRIOR TO COMMENCEMENT OF EACH PORTION OF THE
3100 WORK.

600
2586

2000 1137 C. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY:

2100
WHAT IS REQUIRED BY ONE IS AS BINDING AS IF

1150
1582
REQUIRED BY ALL. THE CONTRACTOR SHALL
COORDINATE ALL PORTIONS OF THE WORK AS

3000
DESCRIBED IN THE CONTRACT DOCUMENTS.

4250
KITCHEN

600
3000

D. UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS

733
400 1 2 3 4 5 6 7 8

2600
ARE TO COLUMN GRID ON CENTERLINES, NOMINAL

2000
850
18 17 16 15 14 13 12 11 10 9 SURFACE OF MASONRY, FACE OF STUDS AND FACE OF
DN CONCRETE WALLS.

1235
750

E. "FLOOR LINE" REFERS TO TOP OF CONCRETE SLABS.


FINISH FLOORING IS INSTALLED ABOVE THE FLOOR
600

BLOW-UP STAIR PLAN LINE. FOR DEPRESSED FLOORS AND CURBS, SEE
STRUCTURAL DRAWINGS.
BLOW-UP KITCHEN PLAN BLOW-UP KITCHEN SECTION
BLOW-UP TOILET & BATH SECTION
C' F. AT SECURITY WALLS, FULL HEIGHT PARTITIONS SHALL
BE SEALED BOTH SIDES WITH ACOUSTIC SEALANT,
TOILET & BATH DETAIL KITCHEN DETAIL TOP, BOTTOM, INTERSECTION, DOOR FRAMES, GLAZED
SCALE:
1500
1:50M.
1200
SCALE: 1:50M. C D OPENING FRAMES, AND ALL OTHER PENETRATIONS.

90 G. LINE OF EXISTING GRADES, AS SHOWN ON THE


750 750 600 600 700 700 3820 BUILDING ELEVATIONS AND SECTIONS ARE
APPROXIMATE.
3100

600
EQ.
H. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT
900

PROVIDED IN THIS CONTRACT, OR BY OTHERS.


1500

1500
2100

2100

2100

2100

2100
EQ.
I. REFER TO ARCHITECTURAL, STRUCTURAL,

1500
MECHANICAL, ELECTRICAL AND OTHER CATEGORIES
1200

OR DRAWINGS FOR ADDITIONAL NOTES.


600

600

600
FINISH FLOOR LINE
DESCRIPTION : ALUM. POWDER COATED DESCRIPTION : ALUM. POWDER COATED DESCRIPTION : ALUM. POWDER COATED DESCRIPTION : ALUM. POWDER COATED DESCRIPTION : ALUM. POWDER COATED J. VERIFY SIZE/LOCATION/FINISH/FIRE-RATING, ETC. AND
W/ 8mm THK. CLEAR GLASS W/ 8mm THK. CLEAR GLASS W/ 8mm THK. CLEAR GLASS W/ 8mm THK. CLEAR GLASS W/ 8mm THK. CLEAR GLASS PROVIDE COMPLETE ALL REQUIRED OPENINGS
SLIDING WINDOW SLIDING WINDOW SLIDING WINDOW AWNING WINDOW W/ FIXED GLASS AWNING WINDOW

3000
THROUGH FLOORS AND WALLS, ACCESS DOORS,

2600
LOCATION : LIVING,GUEST RM. , BR-1&2 LOCATION : FAMILY HALL & BR-1 LOCATION : KITCHEN LOCATION : KITCHEN LOCATION : T&B
QUANTITY : 5 PCS. QUANTITY : 2 PCS. QUANTITY : 1 PC. QUANTITY : 1 PC. QUANTITY : 2 PCS. FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE
ALL BASES AND BLOCKING REQUIRED FOR
W-1 W-2 W-3 W-4 W-5 ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER
EQUIPMENT.
900 800 600 700
18
17 K. ALL PENETRATIONS AND OPENINGS SHALL MEET
16 300
15 WALL ASSEMBLY FIRE RATINGS.
14

1497
13
12 L. ALL LISTED METAL STUD DIMENSIONS, GAUGE &
11
10 THICKNESS ARE MINIMUMS AND ARE PROVIDED AS

167

3000
9
8 BASIS-OF-DESIGN. CONTRACTOR TO VERIFY & SUBMIT
2100

2100

2100

2100

FIXED FIXED 7 FINAL PROPOSED DESIGN.


6
5

1503
900

900

900

900

4 M. REFER TO FINISH SCHEDULES AND COLOR LISTS FOR

1903
3
FINISH FLOOR LINE 2 WALL FINISH DESIGNATIONS.
1
DESCRIPTION : ALUM. POWDER COATED DESCRIPTION : WOOD PANEL DOOR DESCRIPTION : WOOD PANEL DOOR DESCRIPTION : PVC TYPE DOOR DESCRIPTION : FLUSH TYPE DOOR
N. AT ALL PENETRATIONS AND INTERSECTIONS OF

400
W/ 8mm THK. CLEAR GLASS QUANTITY : 1 PC. QUANTITY : 5 PCS. QUANTITY : 3 PCS. QUANTITY : 1 PC. STORAGE
SLIDING GLASS DOOR WITH FIXED GLASS WINDOW LOCATION : MAIN DOOR LOCATION : ALL BEDROOM , KITCHEN LOCATION : TOILET & BATH LOCATION : STORAGE FIRE-RATED PARTITIONS, PROVIDE FIRE SEALANT AND
QUANTITY : 2 SETS / OR FIRE STOPPING TO MAINTAIN CONTINUITY OF
LOCATION : DINING , BALCONY
BLOW-UP STAIR SECTION PARTITION RATING.
D-1 D-2 D-3 D-4 D-5
DOOR & WINDOW ELEVATION DETAIL STAIR DETAIL
SCALE: 1:50M. SCALE: 1:50M.

PROJECT NAME and LOCATION : SHEET CONTENTS : DESIGNED BY : REVISIONS : APPROVED BY : PROJECT NO. :
DRAWN BY :
AS-SHOWN DATE STARTED :
ARCHITECT / ENGINEER
PROPOSED TWO STOREY RESIDENCE
DATE FINISHED : SHEET NO. OF SHEET
DRAWINGS AND COPIES THEREOF, AS INSTRUMENTS OF SERVICE, ARE THE
PROPERTY OF THE ARCHITECT, WHETHER THE WORK FOR WHICH THEY ARE
PTR NO: DATE: CHECKED BY : Engr. MAXIMO ABUKE BARANDINO
T.I.N. PRC. REG. NO. Barangay Narra, Catarman, Northern Samar
MADE MAY BE EXECUTED OR NOT, AND ARE NOT TO BE REPRODUCED OR
USED ON OTHER WORK EXCEPT BY WRITTEN AGREEMENT W/ THE ARCHITECT.
REP. ACT 9266 DATE CHECKED : OWNER