OCEANOGRAPHY 06/29/2024
Aquadopp Profiler 2 MHz - 500 m, Generation 2
Small and compact, short-range current profiling; option for PUV wave
measurements
The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in three profiling
range options, from < 1 m to > 85 m. The 2 MHz version has a current profiling range of up to 10 m. Designed for
simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to
enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.
The upgraded Aquadopp Profiler design offers improved noise immunity as well as 6% broadband measurements
and “hibernation mode” between measurements, enabling precise data collection with lower power consumption.
Increased internal battery storage extends potential deployment time.
Highlights Applications
Up to 10 m current profiling range Near-bed current profiles with fine vertical
resolution
Optional right-angle head for measurements
close to boundaries or in shallow water Mean flow measurements with a focus on
ease of use and simplicity
Pressure-based (PUV) directional wave
measurements Measurements in areas with strong
variations in flow speeds
LED blinks when pinging for peace of mind
during deployment Projects with needs for both high-resolution
and normal-range current measurements
with optional HR
Measurements of waves and currents from a
single instrument
Studies of tidal currents
Technical specifications
Water velocity measurements
Nominal profiling range 10 m
Cell size 0.1-2 m
Maximum number of cells 200
Minimum blanking 0.2 m
Velocity range (along beam) ±1 m/s, ±2.5 m/s, ±5 m/s
Velocity range (horizontal) ±2.3 m/s, ±5.75 m/s, ±11.5 m/s
Accuracy ±1% of measured value ±0.5 cm/s
Horizontal velocity precision (consult Typ. 1 cm/s
instrument SW)
Maximum sampling rate (output) 1 Hz
Wave measurements PUV (optional)
Echo intensity
Sampling Same as velocity
Resolution 0.5 dB
Dynamic range 90 dB
Transducer acoustic frequency 2 MHz
Number of beams 3 (see GA drawings for angles)
Beam width 0.85° (1.7° total)
HR option
Maximum profiling range 4.0 m
Cell size 0.01-0.13 m
Minimum blanking 0.1 m
Maximum number of cells 256
Velocity range 3 cm/s - 0.65 m/s
Range velocity limitations Product of profiling range and velocity should not exceed 0.12
m2/s
Accuracy ±1% of measured value ±0.5 cm/s
Max. sampling rate 8 Hz
Sensors
Temperature:
Temp. range -4 to +40 °C
Temp. accuracy/resolution 0.1 °C/0.01 °C
Temp. time response <1 min
Compass: Solid state magnetometer
Accuracy/resolution <2° for tilt < 30° /0.01°
Tilt: Solid state accelerometer
Accuracy/resolution 0.2° for tilt <30° / 0.01°
Sensors
Maximum tilt Full 3D
Up or Down Automatic detect
Pressure: Piezoresistive
Range 30 m / 100 m / 500 m
Accuracy/precision 0.5% FS / 0.005% of full scale
Data recording
Capacity 16 GB
Real-time clock
Accuracy ±1 min/year
Backup in absence of power 4 weeks
Data communications
I/O RS-422 (inquire for RS-232)
Communication baud rate 9600 Baud - 1.2 Mbaud (default 115200 Baud)
User control Nortek Deployment Software or direct ASCII commands, with
binary or ASCII data output
Software
Operating system Agnostic
Functions Deployment planning, instrument configuration, data retrieval
and conversion. Online data display
Power
DC input 9-24 VDC
Absolute maximum DC input 26 VDC
Maximum peak current 4.5 A
Power consumption Consult Nortek Deployment Software
Sleep current < 10 uA
Transmit power Adjustable
Batteries
Internal battery capacity 1-3 x 50 Wh (Alkaline); 2-3 x 165 Wh (Lithium), 1-3 x 76 Wh
(Li-Ion)
Battery weight 430g per 50 Wh (Alkaline); 380g per 165 Wh (Lithium); 300g
per 76 Wh (Li-ion)
Environmental
Operating temperature -5 to +40 °C
Storage temperature -20 to +60 °C
Shock and vibration Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64
EMC EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019
Depth rating 500 m
Connectors
Bulkhead (Impulse) MCBH-8-FS Brass
Cable PMCIL-8-MP on 5 m (default) polyurethane cable
Materials
Standard model POM, Naval Brass, Titanium Gr. 5, Epoxy
Dimensions (see drawings for details)
Maximum housing diameter 75 mm
Maximum length S2VP: 589 mm; S2SP: 634 mm
Weight
Weight in air (without batteries) S2VP: 2500g; S2SP: 2710g
Weight in water (without batteries) S2VP: -120g; S2SP: -50g
Arrangements
S2VP Shallow water, 2MHz, Vertical orientation, Profiler
S2SP Shallow water, 2MHz, Side-looking orientation, Profiler